Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹85.7 LAccepted-AOC PALTAN BAZAR PWD COLONY KAMRUP M ASSAM | GUWAHATI | KAMRUP M | ASSAM | ₹85.7 L | L1 | Accepted-AOC Successful bidder being L1 |
| 2 | L2₹85.8 L+₹8,713 (0.10%)Rejected-AOC H NO 10 BYE LANE NO 5 F ALI AHMED NAGAR P O KHANAPARA P S DISPUR DIST KAMRUP M ASSAM | ₹85.8 L+₹8,713 (0.10%) | L2 | Rejected-AOC Unsuccessful bidder |
Tender Value
₹85.7 L
EMD Value
₹1.7 L
Closing Date
23 Jun 2025, 2:00 pmClosed
SE PWD Ghy. Bldg Circle-II Chandmari Ghy-3
O/o the SE PWD Ghy Bldg. Circle-II Chandmari Ghy-3
Construction of Main Entrance Gate, Security Room and Adjacent Drainage System at Assam Science and Technology University Campus-1, Guwahati-781013 during the year 2025-26
2025_PWBNH_44656_1
SE/BII/Tech/ASTU_CAMPUS-1
Open Tender
Civil Works - Building
Item Wise
180 days
Assam Science and Technology University, Campus-1
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹1.7 L
Yes
O/o the SE PWD Ghy Bldg. Circle-II Chandmari Ghy-3
30 Jul 2025
31 May 2025
24 Jun 2025
31 May 2025
23 Jun 2025
2 Jun 2025
2 Jun 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level: Cement mortar 1:4 (1 cement :4 coarse sand)
Providing and laying in position cement concrete of specified grad excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete: 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum
All works above plinth level upto floor V level: Concrete of M25 grade with minimum cement content of 330 kg /cum
Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap): 500 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge: Single pile above 50 tonne and upto 100 tonne Safe capacity: Initial test (Test Load 2.5 times the Safe capacity)
Routine test (Test Load 1.5 times the Safe capacity)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing & fixing in position Phenol bonded Bamboowood wall cladding at all height with planks of sizes 10mm thick, minimum 1800mm length and minimum 100 mm wide, in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building Materials & Technology Promotion Council (BMTPC), with necesasary profiled edges fixed with 40mm SS screws 5 nos in each tile to frame work made of second class teak wood of size 20x15 mm in centre of each tile and bottom and top of work height, 40x15mm placed at ends of each tile. The cladding shall be laid over backlayment of 1.00 mm thick expanded polyethylene foam of density 40kg/cum in two layers, first layer on wall surface before fixing wooden frame and second layer on frame under cladding. The bamboowood planks shall have minimum density of 1000 Kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of the Engineer in-charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
3 pin 5/6 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fitting fixing of Philips 18W HL Yes 5 Star 1250 for 18W HL with 6500 K G-13 including necessary connection etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of Philips Base B22 9-Watt Led Bulb complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 8.0 metre and upto 10.0 metre
Supplying and Installation of Octagonal Pole Type BOP or equivalent-10000 Height 10 mtr. The materials of the pole as follows:Conforming to grade S355JO, Base Plate:-Fe 410 Conforming to IS 226/IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization: The poles shall be hot dip galvanized as per IS 2629 /IS2633/IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening: The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia.70 Bottom Dia 130 Sheet Thickness 3mm Rase Plate as specified by the deptt.
Supplying, installation, testing and commissioning of PHILIPS make 120W LED Luminaire Street Light complete with all accessories etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of Nezone Single Arm bracket complete with all accessories etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of POLYCAB INDIA LIMITED make 2 Core 10 Sq mm Aluminium Armoured cable complete with all accessories etc. as required complete and as directed by the Department
Supplying, installation, testing and commissioning of Polycab 1.5 sq. mm. 3 core Copper armoured cable complete with all accessories etc. as required complete and as directed by the Department.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)
12 Module (200mm X 150mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way/6 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying, installation, testing and commissioning of 3MP IP DOME CAMERA complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of 4MP IP BULLET CAMERA complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of TISHA 4000 GB SATA HD Hard disk drive complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of Q-100 Port Fast Ethernet PoE Switch with 2 Gigabit Uplink, 8 10/100Mbps PoE RJ45 port (port 1- port 8) complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying, Installation, testing and commissioning of NUMAX Online UPS of Rating 1.0 KVA With Battery Of Backup Time 30 Minutes complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department
Supplying, installation, testing and commissioning of finolex Control cable for CCTV complete with all accessories Including necessary connection and earthing etc. as required complete and as directed by the Department
Supplying, installation, testing and commissioning of CP PLUS OR EQUIVALENT MAKE 32 Channels NVR with 12 MP (4000 X 3000) complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department
Supplying, installation, testing and commissioning of LG Smart Television Tv 43 Inch LED Backlit LCD complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
Supplying, installation, testing and commissioning of Round PVC Passive Networking Flexible Pipe (DURABLE FELXIBLE PVC PIPE ROLL 1") complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department
Supplying, installation, testing and commissioning of WQ India 19U Rack Enclosures Networking/Server Rack complete with all accessories including necessary connection and earthing etc. as required complete and as directed by the Department.
M/S L.A. ENTERPRISE (BID ID -270529)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .