IMPROVEMENT OF E M INSTALLATION AND DISTRIBUTION OF ELECTRIC LOAD AT AF STN UNDER GE AIR FORCE STATION JAMMU
2024_MES_658634_1
CWEAFJ-21/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Jammu
All as per Tender Documents
9 documents required · 9 mandatory
₹1,000
GE (AF) Jammu
₹2.2 L
Yes
17 Jan 2025
8 Jun 2024
19 Sept 2024
8 Jun 2024
17 Sept 2024
25 Jul 2024
Amount
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminum conductor,11000 volts earthed, grade cross sectional area of size 3 core 120 sq mm , complete all specifiad and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 mtr in depth for laying cable etc and getting out in average of soft soil and hard dense soil, complete all specifiad and directed.
M & L sand cushioning with river washed and screened dry fine sand to under ground cable 23 cm thick, 8 cm below the cable and 15 cm after laying the cable, duly punned complete.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete with hard dense soil complete all specifiad and directed.
Removing excavated surplus soft/hard dense material n exc 50 m and deposited where directed at a level n exc 1.5 M above the starting point all as directed.
Un-reinforced precast concrete cable cover ,class HV,type-1 size 300X180X40mm complete all as specified & direction.
M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in road, pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm. to 185 Sqmm, complete all specifiad and directed.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, complete all specifiad and directed.
Supply and fix cable duct with MS chequered plate 08 mm thick with impression on one face cut two and size 900 mm X 600 mm including two handles that should be flush to level of duct cover complete all as per direction by Engr-in-charge.with good finishing including red oxide paint after black paint.The drawing of the iron duct cover plate to be approved by Engr-in-Charge.
S & F RCC M-25 cable duct cover 780X540X65 mm having 10 mm dia TMT bar @ 100mm spacing in longitudinal and transverse direction with angle iron frame of 65X65X6 mm cover protection from outer support including two handles that should be flush to level of duct cover complete all as per direction by Egrn-in-charge.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending colt or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint. The drawing of the structure to be approved by Engr-in-Charge.
S & F cable route indicator made out of 25 x 25 x 3 mm angle iron, 0.45 mtr long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 6 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 20 mm graded aggrregate) block of suitable size and neccessary earth work and excavation all as specified and directed.
Supply and fixing panel of Power battery bank with SMPS battery charger- 02 Nos with 24 volt DC 02 battery 200 AH maintence free with MCB DP 4 Nos 16 Amp, Single phase DP for AC supply 20 Amp for back supply of VCB and connected to VCB Panel all as specified & Directed.
Supply, installation , testing and commisioning of Diesel Engine CPCB4 approved 160 KVA TP inbillet with AMP panel generating 199 HP @ 1500 RPM , dirrectcoupled with 160 KVA three phase 415 Volts CG/LS Alternator and all accessories in housed in a acoustic enclosuresound proof canopy including necessary connection complete all as specified and directed by Engr-in-Charge. Make Mahindra/ Kirlosker/Cummins
DIESEL ENGINE Liquid cooled, electric start four stroke, six cylinder totally inclosed diesel engine developing199 HP at 1500 RPMat NTP. The engine is suitable for generating set application and fitted with the following standard accessories Flywheel to suit coupling, suitable coupling, water cooling arragment,Radiator, Lub Oil Filter, Lube Oil Pump,Fuel Pump, Hose to fuel pump, Air cleaning assembly,Residential Heavy duty silencer, Engine fitted with low lube oil presure gauges.
Engine monitoring, protection and diagnostics. (i) Lube oil pressure. (ii) Coolant Temperature. (iii) Engine Speed. (iv) Hours Run. (v) Battery voltage. (vi) Common Warning. (vii) Common shut down. (viii) High coolant temperature warining and shutdown. (ix) Low lube oil pressure warning and shut down (x) Low coolant level shutdown. (xi) Over speed shutdown. (xii) Charging failure indication. (xiii) AC metering and alternator protection. (xiv) 3-Phase AC Amps. (xv) KW (xvi) KVA (xvii) Power factor. (xviii) Frequency. (xix) Over voltage. (xx) Under voltage.
ALTERNATOR 160 KVA TP CG/LS alternator at 1500 RPM, 0.8 lagging power factor, providing three phase 415 volts suitable for 50 HZ, H class insulation winding, close direct coupled, self excited and self regulated type,screen protected mounted on regid MS sheet chenel base frame. The alternator shall confirm IS 13364, IS 4722, BS 5000 suitable for tropical condition. CONTROL PANEL Fitted inside canopy,fabricated out of 1.6 mm CRCA sheet cubical type totally inclosed power coated control panel incorporating the following. Low oil pressure metering and safety , Fuel level gauge in % metering and safety,High water temp metering and safety, Voltage & Amp metering and safety, Power factor metering , Engine RPM , Frequency meetering and safety.Note - All accessories should be provided by company.
TROLLEY Fabrication of iron trolley for mounting of DG set of capacity 160 KVA , having trolley structure-ground clearance should be approximate 320 mm (32 CM) unladen -turning circule should be equal to 13.3 meters . Trolley should be compatible with twin line air beak system . floor shall be 6 mm thick steel sheet welded to frame . Wheels -Rim size shall be 6.5 Hx16 SDC for fitment of tyre size 9.00x16-10 ply rating cross country non directional tread. miscellaneous fittings -one number plate of size 460 mm x 110 mm ,one hook at the rear for tandem towing, triangular reflex reflector - total four numbers , two in front and two in rear ,reflector type T sign plate at the rear end of the right side , lubrication chart indicating lubricating points, periodicity and lubricants, Suspension-trolley shall be mounted on an axle by two elliptic lead spring on each axle,spring shall be made of silica manganese steel , AXLE front axle shall have Ackerman type steering wheel and rear axle shall be made out of rigid type.Cable roller should be attached with trolley for rolling the cable.
Supply and Fixing GI tubing light grade 80mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Supply instalation testing and commissioning of Surge voltage arrester consisting of base element with remote indicator contact and ground connectors, for mounting on NS 35/7.5, nominal voltage: 230 V AC, 3 + 1 circuit protection With floating remote indication contact Multi-channel type 2 arresters Optical, mechanical status indication for the individual arresters Type 2 consistent plug-in surge arresters Mechanical coding of all slots Disconnect device on each individual plug , Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) Vibration (operation) 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) General IEC test classification II T2 EN type T2 IEC power supply system TN-S TT Mode of protection L-N L-PE N-PE Mounting type DIN rail: 35 mm Color jet black RAL 9005 Housing material PA 6.6 PBT Degree of pollution 2 Flammability rating according to UL 94 V-0 Type DIN rail module, two-section, divisible Number of positions 4 Surge protection fault message Optical, remote indicator contact Protective circuit Nominal voltage UN 240/415 V AC (TN-S) 240/415 V AC (TT) Nominal frequency fN 50 Hz (60 Hz) Maximum continuous operating voltage UC (L-N) 275 V AC Maximum continuous operating voltage UC (L-PE) 275 V AC Maximum continuous voltage UC (N-PE) 260 V AC Rated load current IL 80 A Residual current IPE ≤ 5 µA Standby power consumption PC ≤ 360 mVA Nominal discharge current In (8/20) µs 20 kA Maximum discharge current Imax (8/20) µs 40 kA current interrupt rating Ifi (N-PE) 100 A Short-circuit current rating ISCCR 25 kA Voltage protection level Up (L-N) ≤ 1.35 kV data Protective circuit Voltage protection level Up (L-PE) ≤ 1.6 kV Voltage protection level Up (N-PE) ≤ 1.5 kV Residual voltage Ures (L-N) ≤ 1.35 kV (at In) ≤ 1.1 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (L-PE) ≤ 1.6 kV (at In) ≤ 1.2 kV (at 10 kA) ≤ 1 kV (at 5 kA) ≤ 0.9 kV (at 3 kA) Residual voltage Ures (N-PE) ≤ 0.4 kV (at In) ≤ 0.25 kV (at 10 kA) ≤ 0.15 kV (at 5 kA) ≤ 0.1 kV (at 3 kA) TOV behavior at UT (L-N) 335 V AC (5 s / withstand mode) 440 V AC (120 min / safe failure mode) TOV behavior at UT (N-PE) 1200 V AC (200 ms / withstand mode) Response time tA (L-N) ≤ 25 ns Response time tA (L-PE) ≤ 100 ns Response time tA (N-PE) ≤ 100 ns Max. backup fuse with V-type through wiring 80 A (gG) Max. backup fuse with branch wiring 125 A (gG) Indicator/remote signaling Switching function PDT contact Operating voltage 5 V AC ... 250 V AC 30 V DC Operating current 5 mA AC ... 750 mA AC 1 A DC Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section flexible 0.14 mm² . 1.5 mm² Conductor cross section solid 0.14 mm² ... 1.5 mm² Conductor cross section AWG 28 ... 16 Connection data Connection method Screw connection. Make:-CITEL/ABB/SCHNEIDER/PHONIX The entire work is to be executed by OEM only approved by GE. The Contractor has to submit Original Purchase Vouchers, Test Certificates & Guarantee Certificate from OEM before installation at site
Taking out UNSV manual analog cum numerical relay replace with S/I/T/C of new microprocessor type inverse definite minimum time fault recorder along with protection system with Plug Setting Multiplier of Relay, Time Setting Multiplier of Relay, Time vs. PSM Curve settings,Calculation of Relay Operation Time,1. Current setting. 2. Fault current level. 3. Ratio of current transformer. 4. Time / PSM curve. 5. Time setting. Output impedance shall be 3.0 to 5.0 percent,The card shall be manufactured such that it will maintain electrical properties, even under severe overload, under/over voltage and under/over frequency conditions. Input correction range shall be -30% to +20% of nominal input voltage. The system design shall be capable of operating at an input frequency range of -15% to +10% of nominal, without clearing protective devices or causing component failure within the Microprocessor Card. Upon turn on or restart, the output of the Microprocessor Card shall not exceed the specified output regulation limits. if the input voltage or frequency exceeds programmable minimum or maximum set points for a programmable time period (factory set for 10 seconds), the Microprocessor Card shall electronically shut off. When electrical parameters are back within acceptable limits for a programmable time period (factory set for 60 seconds), the Microprocessor Card shall automatically restart to provide conditioned power to the load. If the input parameters are within acceptable limits, but the output voltage is outside of acceptable programmed limits, the Microprocessor Card shall electronically shut off and require a manual restart. The Microprocessor Card shall be capable of operating at 100% rated load capacity continuously, 200% rated load for 10 seconds, 500% rated load for 1 second and 1000% rated load for 1 cycle. Operating efficiency shall be a minimum of 96%, typical at full load. Transverse-mode noise attenuation shall be 3dB down at 1000Hz and 40dB down per decade to below 50dB with a resistive load. Common-mode noise attenuation shall be 140dB or greater. The Microprocessor Card shall respond to any line voltage variation in 1/2 cycle while operating linear or non-linear loads, with a load power factor of 0.60 of unity. Peak detection of the voltage sine wave shall not be permitted to avoid inaccurate tap switching due to input voltage distortion. Line Voltage Regulation and Correction Time: Output regulation shall be +5%, -6%, given an input voltage variation of -30% to +30% for nominal, when within +/-5% of the nominal frequency. The Microprocessor Card output voltage shall be corrected to within +5%, -6% or less within 1 cycle per tap for an under voltage condition. For an over voltage condition, the output shall correct within 1 cycle directly to the appropriate tap without stair-casing intermediate taps. Typical correction time shall be 1 to 2 cycles. Load Regulation: No load to full load regulation shall be 3% typical under linear loading. Note: The Microprocessor Card shall be adjusted so that the combination of line voltage regulation and linear load regulation results in a maximum output voltage variation of +7% to -8% from nominal, when within +/-5% of the nominal frequency. Operating Frequency: The Microprocessor Card shall be capable of operating at +10% to -15% of the nominal frequency, 50Hz or 60Hz, with programmable high and low limits to alarm and electronically shut down the Microprocessor Card. Limits shall be set to +/-2Hz from nominal and electronic shutdown shall occur if limits are exceeded for 10 seconds. Once back within limits for a programmable time period of 60 seconds, the Microprocessor Card shall automatically restart. 2.5 Site Specific Data: Input Over Current Protection:
The Microprocessor Card shall be provided with an integral, three pole, molded case, manually operated, thermal magnetic input circuit breaker rated at 125% of the full load input current. In addition, the system input current, Phase R, Y and B, shall be monitored and digitally displayed. A programmable over current alarm shall be provided. Bypass Switch: The Microprocessor Card shall be provided with an integral break before make rotary bypass switch. The Microprocessor Card shall be either on line or bypassed with one turn of the switch. On models where the input and output nominal voltages are different, a regulator bypass shall be provided in which the shielded isolation transformer will remain on line to provide voltage transformation and isolation. On models where the input and output nominal voltages are the same, an integral break before make rotary maintenance bypass switch shall be provided to wrap around and isolate the Microprocessor Card. In this case, an input neutral conductor(s) shall be provided and the bypass switch shall bypass the output neutral, as well as, the phase conductors. The bypass switch circuitry shall be wired such that it cannot switch the unregulated power directly to the active load. Bypass switch actuation shall trip the Microprocessor Card input breaker, so that the facility load must then be reconnected using the input breaker.Alarms: The Microprocessor Card shall be provided with an input over/under voltage, input over current, over/under frequency, voltage phase reversal, voltage phase imbalance, output over/under voltage, and output over current alarms. The alarms shall automatically reset upon return to nominal operating conditions. Remote communication of alarms via a contact closure shall be provided. Optional digital communication via RS232 and RS485 shall be made available. The Microprocessor Card shall be provided with individual “Fuse Failure” indicator lights, phase R, Y and B, on the front panel for diagnostic purpose. The Microprocessor Card shall be equipped with True RMS Measurement, Stores last 15 faults, Detection of fault with display of parameter value, USB configuration with PRKAB, CBCT open detection circuit Earth Leakage Re to Detect and protect instruments from leakage current, Dual Color LED for fault indication, : A digital input meter shall be provided to display line voltages, line currents, frequency, kVA, kW, and power factor. A separate digital output meter shall be provided to display line to line voltages, line to neutral voltages, phase currents and neutral current. Both meters shall have programmable minimum and maximum value set points, recorded in EEPROM. Both meters shall be capable of optional remote communications via RS232 and RS485. Input/Output Cable Connections: The Microprocessor Card shall have provisions for the installation of cable lugs directly to the input/output bus bars or conductors to the input/output terminals provided. Grounding Cable Lugs: The Microprocessor Card shall have provisions for the installation of cable lugs directly to the ground bus bar or conductor to the terminal provided. MAKE / ABB/ CG/ MIN ISO 9001:2015 CERTFIED APPROVED BY GE ONLY Original OEM is entitled for work . Contractor has to ensure it.Necessary test certificates & Latest Purchase Vouchers to be scrutnised / approved by Engg-in-Charge & GE first before execution at site . Any Defect occuring during this period due to bad workmanship of material, manufacturing defect shall be rectified or replaced free of cost. The contractor shall furnish written gaurantee on letter head for above mentioned to the GE immidiately after completion of work. Contractor has to ensure Post Audit of work, without that completion will not be issued.
Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA suitable for 33000 Volts grade and entire satisfaction of Engnr-in-Charge complete all as specified and directed
Supply and installation of advance maintenance free Earthing System by boring the required threenos of holes in semi hard soil or hard soil consisting of 01 Nos UL-467 listed and CPRI tested copper high tensile low carbon steel coreelectrode rod of 17.2 mm dia with a minimum coating thickness of 250 microns and length of 3 mtrs tested according IEC 62561-2 with min 10 years life span(the rod should be marked as per the UL certification) incl min 25 kgs/electrode of earth enhancing compound (PROCEM) NABL certified CPRI tested ecofriendly tested as per the IEC 62561-Z and needs to be considered to fill the 100 mm bored hole surrouning to the electrode. The earth enhancing compound should have resitivity less than 50 ohms -meter with chemically inert to sub soil that should not pollute the enviroument and non corosive to the earth electrode itself Provison of the connectors for connecting electrode with earthing conductor/strip including fastener made of brass /copper with brazing overlap portion of strip and electrode all sides having suitable size according to the electrode and earthing conductor dimensons.All the three earthing electrode would be seperated by appropriate distance and connected to each other by and incl 25mm x 3mm copper strips to make ring earth and further connected to the test point terminal and to be burried in appropriate depth not less than 40 cm below normal ground level and earthing pit chamber of suitable size not less than250x250x250mm internal dimension made of FRP material completed with flush mounted,removable and lockable cover able to with stand 15kN for eachrode all as directed by Engr-in-Charge.The chamber should have facility for marking earth resistance and latest testing date by paint at the cover and previous recorded value inside the cover all as per the descrition of Engr-in-Charge Note- Earthing test result shall be less than 1 Ohm.
Earth continuity conductor 20x3.15 mm copper strip or main earthing lead fixed to wall on battan or recess or chasses or burried in ground or drawn in conduit /pipe or fixed to pole or any other indicated situation for loop earthing etc and joining of earth lead shall be carried out with proper size of copper nuts,bolts and washers including drilling holes at least 2 nos per joint including necessary brazing of copper strips of four sides of lapping of copper strip all as specified and directed by Engr-in-Charge.
Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) 6 mtrs Ohot dip Galvanized Octagonal pole, silver color complete with Top dia 70mm, Bottom dia 130 mm, 3mm thick, MS base plate 200X200X12mm and foundation bolt M20X600mm and street light bracket single arm suitable of LED street light including PCC and drilling of holes of required size etc complete all as specified and directed.
Supply and fixing of ALL-IN-ONE smart integrated Solar street light, fully intelligent designed luminiare with built in Mono CrystallinePanel (48 Watt), Lithium Ferro Phospate(LifeP0 4) battery, 12.8 V, 30 Ah (BIS certified) , MPPT charge controller and PIR Sensor with colour temperature 6000-6500K, 2 days autonomy with dimming, mordern portable design, dust proof, waterproof with luminaire efficacy of 120 lumen/watt, LED lamp lifebof 50000 hrs and system wattage of 30 watt complete all as specified and directed by Engr-in-charge. Note :- 32 Nos of solar street light to be installed on existing pole of various location and old 32 Nos street light removed from existing pole contractor shell be deposite to department for reuse.
Supply, testing and laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor 33000 volts (Earthed) grade of size 300 sqmm single core complete all as per Engr- in-charge. Note : Four runs of 300 Sqmm single core HT armoured cable shall be considered as one, complete all as specified and directed by Engr-in-charge.
Cable end termination jointing kit for 33 KV (Earthed) grade cable outdoor type,heat shrink type joint complete with jointing material and accessories suitable for single core XLPE Sqmm and entire satisfaction of Engnr-in-Charge complete all as specifiedand directed
Continental Enterprises (BID ID -3094356)
Bidder Name
MAMTA ENTERPRISES
Continental Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .