REPAIRS TO INTERNAL WIRING, SUBMAIN WIRING, LED FITTINGS, FANS, GEYSERS, SUMMER COOLING APPLIANCES, DG SETS AND CERTAIN ALLIED E/M WORKS AT MIL STATION BHUSAWAL UNDER GE (S) AHILYANAGAR
2026_MES_790002_1
8390/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Bhusawal
Class D and category b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahilyanagar
₹56,000
Yes
18 Sept 2026
18 Sept 2026
10 Oct 2026
18 Sept 2026
8 Oct 2026
2 Oct 2026
18 Sept 2026 - 25 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. | 824 | Point | - | - |
| 2 | M & L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC boards for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch.
NOTE : 1. Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)
2. Wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg.
3. All points shall be earthed upto lights fittings, fans,bldg security lights etc. | 430 | Point | - | - |
| 3 | All as per serial item No. 2 here in before but for one 6 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified. | 80 | Point | - | - |
| 4 | All as per serial item No. 2 here in before but for one 6 Amp 5 pin socket outlet point on independent board. | 70 | Point | - | - |
| 5 | All as per serial item No. 2 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. | 10 | Point | - | - |
| 6 | All as per serial item No. 2 here in before but for one light point controlled by two 2-way switches | 1 | Point | - | - |
| 7 | All as per serial item No. 2 herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase,Neutral and earth for one 16 Amp, 6 pin socket on independent board. | 60 | Point | - | - |
| 8 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade, conforming to IS-694 1990, PVC insulated and unsheathed , FRLS cable laid / fixed and including concealed PVC rigid conduit on walls/ceiling alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including including Sunken box, including PVC boards/bakelite sheets / and including factory made terminal boxes with modular cover plates and frames suitable for mounting switches, sockets, fan Regulators, accessories etc as specified and as directed for one light point or one fan point controlled by one, one way switch
NOTE :-
1.Proper colour coding shall be adopted for wiring (for phase-RED, YELLOW, BLUE for Earth-Green and Neutral-Black)
2.wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg.
3. All points shall be earthed up to fixtures i.e holdrs,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.
4. Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall ,floors etc. | 100 | Point | - | - |
| 9 | All as per serial item No. 8 here-in-before but for one 6 Amp, 3 pin socket outlet point on same board with other switches including earth wire as specified. | 26 | Point | - | - |
| 10 | All as per serial item No. 8 here-in-before but for one 6 Amp, 3 pin socket outlet point on independent board with other switches including earth wire as specified. | 23 | Point | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
BOQ_885589.xls
BOQ • 0.74 MB
8290Tenderdocuments.pdf
Tender Documents • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .