Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹50.9 L+₹1.3 L (2.53%)Rejected-Finance R O Y K PURA QAZIGUND ANANTNAG 192221 J K | ANANTNAG | JAMMU AND KASHMIR | 192221 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹51.1 L+₹1.5 L (2.94%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹51.7 L+₹2.1 L (4.13%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹51.7 L+₹2.1 L (4.26%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹46.2 L
EMD Value
₹92,400
Closing Date
11 Sept 2023, 6:00 pmClosed
GE 860 EWS
GE 860 EWS
SPL REPAIR TO EXTERNAL ELECTRIC SUPPLY, SOLAR LIGHT AND ALLIED WORKS AT U FORCE KIARI, CHUMATHANG AND 2 ASD NYOMA, PROVN OF BATTERY CHARGING ROOM FOR 698 COY ASC TK TPTR TYPE A AT MUDH AND PROVN OF SPECIALIST SHOP FOR SMALL ARMS SEC AT 179 I WKSP UN
2023_MES_614927_1
8168/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kiari, Chumathang, Nyoma and Mudh
Refer NIT
9 documents required · 9 mandatory
₹500
GE 860 EWS
₹92,400
Yes
30 Sept 2023
22 Aug 2023
13 Sept 2023
22 Aug 2023
11 Sept 2023
6 Sept 2023
Amount
Surface dressing n exc 15 cm deep in soft /loose soil
Excavating in post holes (or similar holes)each n. exc 0.5 cum, getting out, returning, fillingin and ramming erth pr broken rubble mixed with eart around, in layers not exc 25 cm all as specified and directed by Engr in charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard /dense soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for Cement concrete type D2 1:4:8 (40 mm graded aggregate) in foundations, filling and mass concrete
M &L Cement Concrete Type-B1 (1:2:4)) in foundations,including rafts, footings complete all as specified and directed.
S & F steel work in roof trusses (framed ) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam,tee,angle,channel or flat sections) including distance pieces cleats etc
M & L for Pre-cast cement concrete block masonry type C-1 1:3:6 (20 mm greded aggregate) with solid blocks, exc. 10 cm in width and setting in mortar 1:6, complete
M & L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface
Plinth protection 75 mm thick in PCC type C1 1:3:6 (using 20 mm graded aggregate crushed stone aggregate) laid in alternate bays (not exc 2 Sqm each) finishing even smooth at top without using extra cement and providing joints throughout the thickness of plinth protectio, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed at site.
M & L for PCC 100 mm thick 1:2:4 type D2 (40 mm graded aggregate) as in floor finishes with smooth surfaces all as specified
S & F for 2nd class soft wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints.
S & F for Factory made shutter 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as specified and directed by Engr-in-charge.
S & F 30mm thick Second class hard wood Glazed and skeleton windows,ventilators open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc.sizes of members of shutters as specified in SSR Part I, Section 8 Clause 8.24(a)
S & F 3.00 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, all as specified.
M & L PCC type B-1 1:2:4 (20 mm graded aggregate) for fixing hold fast
S & F MS flat iron of size 25x3 mm as in hold fast conforimg to Fe 410-0 or Fe-310-0
15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surface etc. on wall finished even smooth without using extra cement, all as specified.
Rendering 15 mm thick on fair faces of brick wall or cement concrete surface in cement mortsr 1 :4 finished even smooth without using extra cement, all as specified.
S & F of 100 mm size extruded alluminium alloy with galvanised mild steel butt hinge pin type C-21
S & F Aluminium anodised, barrel tower bolts of extruded section with 150 mm long bolt and fixed all as specified
S & F Aluminium handles, cast type, anodised 125 mm size complete all as specified
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, 250 mm long
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, 150 mm long
S&F for 0.50 mm thick Pre- painted galvatume aluminum zinc coating GI based corrugated in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as directed by Engr-in-Charge.
M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes etc. with riveted, bolted or welded attachment confirming to Fe 410-W (Gde E-250), complete all as directed by Engieer-in-charge.
Mild steel bolts neck exc 10 mm dia and n exc 15 mm dia, purpose made, with hexagonal or square head one end and screwed the other, or screwed both ends; each scre-wed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10cm long
M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and treating with two coats of synthetic enamel paints over a coat of red oxide primer.
Preparing plastered new surfaces of wall and applying two coats of cement base paint with one coat of primer all as specified.
Preparing of new surface of wall of any description and applying two coats of distemper oil emulion, with one coat of primer all as specified.
Prepration of new wooden or wood based Surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, all as specified.
M&L for point wiring in casing in caping including all fittings with 1.5sqmm size multi stranded FRLS copper conductor cable including clamps , screws gutti/plug etc PVC unsheathed cable into and including PVC box for mounting of switces and PVC insulated FRLS cable of size 1.5sqmm as earth continuity conductor for one light point or one fan point controlled by one, one switch complete all as specified and as directed by the Engineer-in-Charge
All as per srl item no. 32 here-in-before but for one socket outlet 3 pin, 5 Amps on same board.
All as per serial item No 32 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor (Multi-stranded) insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common dolly complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing switch piano flush button single pole one way 5 Amps complete
Supply and fixing socket 2 in 1, 5 Amp, flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing switch socket combination multi purpose 2 in 1, 3 pin 5A/16A, 5 in 1 flush type complete all as specified and as directed by Engr-in-charge.
Supply and fixing ceiling rose, surface bakelite, 65 x 50 mm, three terminals complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement angular lamp holder, PVC/Polycaronate type with back plate suitable for 12 watt LED bulb for batten fittings complete all as specified and directed by the Engineer-in-Charge.
Supplying and fixing in replacement LED 12 Watt with 6500 K complete all as specified and directed by Engr-in-Charge Make: Philips/Crompton/Havells/Wipro Or Equvalent approved make.
S&F DB, Single Door, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof, suitable for incorporation of MCB’s and isolators etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed.
Supply and fixing MCB single pole and neutral 32 to 40 Amps , 240 volt, 10 KA, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing MCB single pole 5 to 30 Amps, 240 volts, 10 KA complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing new energy saving LED Bulk head fitting 10 watt made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK07 as reqd to be mounting bracket in wall/floor to suit the opening of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection complete all as specified and as directed by Eng-In-Charge
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 3 of SSR 1991 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
Returning, filling in excavated soil, including leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed by the Engr-in-Charge.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying, streching & testing of cable in trenches complete all as specified and directed by Engr-in-Charge. Note :- Only punned thickness i.e 18cm shall be measured and paid.
Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
Taking out Old U/S LED street light fitting any size/watt complete all as specified and as directed by Engineer-in-Charge.
Taking out Old U/S LT Pole diconnecting of all light fitting any size removing the brakets and shifting to store as a schedule of credit all as specified and directed by Engineer-in-Charge.
Supply and erection in vertical position steel tubular swaged pole type 410 SP- 31 (9 mtr long ) with Mild Steel base plate of size 30cmx30cmx6 mm thick continuously welded to pole , finial taper plug ,bolts ,nuts and screws all as specified including factory painted with two coats of black bituminious paint internally throughout and externally for embedded position and two coats of aluminium paint over a coat of red oxide primer over the ground and making 30cm wide strip (total 18 Nos ) with black and yellow paint including numbering complete all as specified .
Supply,testing and commissioning weather and vermin proof L.T. feeder pillar box size 0.9 x 0.9 x 0.7 m factory fabricated out door cubicle/kiosk type totally enclosed made out of 3.0 mm thick sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 40x40x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium completeall as specified and directed by Engineer -in -Charge and consisting of following:-
Supply,testing and commissioning weather and vermin proof L.T. feeder pillar box size 0.9 x 0.9 x 0.7 m factory fabricated out door cubicle/kiosk type totally enclosed made out of 3.0 mm thick sheet metal enclosure of suitable size, with angle iron frame of M.S. angle 40x40x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium completeall as specified and directed by Engineer -in -Charge and consisting of following
S&F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire as in OH Conductors including Stringing, Tightening, complete all as specified and as directed by Engr-in-charge . Note : The 3% for sag, joints & jumpers shall be added in measurements.
Dismantiling & Disconnecting of Aluminium Conductor Steel Reinforced (ACSR) (any Size) of Overhead electric poles disconnecting the elec connection removing the brakets,Insulator etc and shifting to store as a schedule of credit all as complete all as specified and as directed by Engineer-in-Charge.
Galvanised steel earth wire of 4mm dia with hooks, , streching kinks and bends completed all as specified & directed.
Dismantiling & Disconnecting of Galvanised steel earth wire of any size removing the brakets , Poles and shifting to store as a schedule of credit all as specified and directed by Engineer-in-Charge.
S&F cross arms, bracing ,supports clamps & back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as directed.
S&F Pin type, porcelain, vitreous white, brown or green insulator incl one galvanized mild steel spildle, two galvanised iron washer and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, testing and commissioning, in replacement, Junction box , cubical type, factory made, outdoor type of Size 14 cm(h)x 14cm(w)x 9.5 cm(d) , Shockproof and rustproof,high heat distortion temp ( 200⁰ C ,cable entery from bottom /side 100 % weatherproof and connecting incomming and outgoing cables with suitable size complete all as specified and as directed by Engineer-in-Charge.(Make:- Sintex or equvilants )
Repair/replacement of 30 Watt solar street light,Integrated with 30 Amp life Po4 Battery,100 Watt solar panel complete as per directed and specified by Engr-in-charge.
Earthing complete with Chemical earthing with copper earth plate 90x60cmx5mm & copper earth strip 32x6 mm complete all as specified and as directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm dia, laying of Underground cable for road crossing. Complete all as specified and as directed by Engineer-in-Charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 80 mm dia laying of Underground cable for road crossing. Complete all as specified and as directed by Engineer-in-Charge.
Supply, laying, testing and commissioning of LT UG cable XLPE insulated PVC sheathed galvanized steel strip armoured electric power cable with stranded aluminium conductor 1100 volts grade 70 sq mm 3.5 core confirming to IS:7098 (Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles & screws etc and making connection, complete all as directed. Make : Havells/Finolex/Polycab/KEI Note : 1. The cost of Al thimbles/lugs and cable gland etc is included in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as srl item no 68 here-in-before but for cable size of 50 sqmm 3.5 core.
All as srl item no 68 here-in-before but for cable size of 35 sqmm 3.5 core.
All as srl item no 68 here-in-before but for cable size of 25 sqmm 4 core.
All as srl item no 68 here-in-before but for cable size of 16 sqmm 4 core.
All as srl item no 68 here-in-before but for cable size of 16 sqmm 2 core.
All as srl item no 68 here-in-before but for cable size of 10 sqmm 2 core.
M&L in replacement for PVC insulated and sheathed multi strandard 2 core 1.5 sqmm flat 1100 volts grade electric copper cable complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 3.0 m depth for foundation of poles and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
M/S BHAT ENGINEERS
Takshos Enterprises
osho traders
THINLES OTZER
M/S MA CONSTRUCTION Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .