Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹22.9 L Quoted ₹23.9 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹24.2 LRejected-Finance | ₹24.2 L | L2 | Rejected-Finance Not Found in order |
| 3 | L3₹26.4 LRejected-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | ₹26.4 L | L3 | Rejected-Finance Not Found in order |
| 4 | L4₹29.8 LRejected-Finance B 11 SCHOOL ROAD UTTAM NAGAR NEW DELHI DELHI 110059 UDYAM DL 11 0049695 | WEST DELHI | DELHI | 110059 | ₹29.8 L | L4 | Rejected-Finance Not Found in order |
| 5 | L5₹30.2 LRejected-Finance E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | ₹30.2 L | L5 | Rejected-Finance Not Found in order |
| Sl No | Description | Qty | Unit | Surjit and Sons L9 | B.R. Enterprises L6 | Microsys Automation India L2 | RS GREEN INDIA CONSTRUCTION L8 | RND ENGINEERS & CONTRACTORS L10 | sumit associates L11 | PRASAD ELECTRICALS L5 | M/s Naresh Kumar Gupta & Co. L4 | MISHRA ELECTRICAL L7 | AMIT ENTERPRISES L3 | M P TYAGI ENGINEERS AND CONTRACTORS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00M/L maintenance and servicing of DG Set of any capacity complete by replacing the fuel filter, lubricating oil filter, replacement of air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour minimum at connected load and record shall be made in respect of RPM , oil pressure, oil temprature, coolant temprature, voltage, frequancy, load current, battery charging, fuel consumption & noise level etc complete all as specidied and directed. Note :- 1. Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item. 2. Major spare parts/Oil/Coolant etc will be measured and paid Seprately under respective of schedule 'A'. 3. DHPP will be issued by dept for testing only. | ||||||||||||||
| 1.01 | 160 to 320 KVA Capacity | 5 | EACH JOB | 8,000 ₹40,000 | 8,500 ₹42,500 | 6,000 ₹30,000 | 15,000 ₹75,000 | 1,500 ₹7,500 | 1,500 ₹7,500 | 2,500 ₹12,500 | 2,400 ₹12,000 | 2,200 ₹11,000 | 2,222 ₹11,110 | 4,999 ₹24,995 |
| 1.02 | 100 to 125 KVA Capacity | 8 | EACH JOB | 7,000 ₹56,000 | 5,500 ₹44,000 | 4,000 ₹32,000 | 14,500 ₹1.2 L | 1,200 ₹9,600 | 1,000 ₹8,000 | 2,200 ₹17,600 | 1,800 ₹14,400 | 2,000 ₹16,000 | 2,222 ₹17,776 | 6,999 ₹55,992 |
| 1.03 | 50 to 75 KVA Capacity
(Note : For serial item no 1.01 to 1.03 Spares parts required shall be measured and paid separately under respective itms of Schedule as supply only.) | 10 | EACH JOB | 6,000 ₹60,000 | 4,500 ₹45,000 | 3,000 ₹30,000 | 11,000 ₹1.1 L | 1,000 ₹10,000 | 700 ₹7,000 | 1,500 ₹15,000 | 1,400 ₹14,000 | 2,000 ₹20,000 | 2,222 ₹22,220 | 4,999 ₹49,990 |
| 2.00Supply only of following items for DG Sets Capacity of 160 KVA to 320 KVA (Required under Sl item No. 1.02 above) :- | ||||||||||||||
| 2.01 | Air Filter | 5 | EACH | 7,000 ₹35,000 | 5,500 ₹27,500 | 2,200 ₹11,000 | 800 ₹4,000 | 1,200 ₹6,000 | 625 ₹3,125 | 400 ₹2,000 | 2,200 ₹11,000 | 3,200 ₹16,000 | 888 ₹4,440 | 999 ₹4,995 |
| 2.02 | Fuel Filter | 5 | EACH | 2,000 ₹10,000 | 850 ₹4,250 | 890 ₹4,450 | 1,100 ₹5,500 | 251 ₹1,255 | 750 ₹3,750 | 345 ₹1,725 | 1,800 ₹9,000 | 3,000 ₹15,000 | 888 ₹4,440 | 999 ₹4,995 |
| 2.03 | Lubricating oil filter | 5 | EACH | 1,600 ₹8,000 | 900 ₹4,500 | 290 ₹1,450 | 1,100 ₹5,500 | 600 ₹3,000 | 400 ₹2,000 | 655 ₹3,275 | 1,600 ₹8,000 | 1,900 ₹9,500 | 888 ₹4,440 | 999 ₹4,995 |
| 3.00Supply only of following items for DG Sets Capacity of 100 ot 125 KVA (Required under Sl item No. 1.03 above) :- | ||||||||||||||
| 3.01 | Air Filter | 8 | EACH | 6,000 ₹48,000 | 3,200 ₹25,600 | 2,800 ₹22,400 | 800 ₹6,400 | 1,000 ₹8,000 | 625 ₹5,000 | 433 ₹3,464 | 1,800 ₹14,400 | 2,200 ₹17,600 | 888 ₹7,104 | 999 ₹7,992 |
Updated dates
Tender Value
₹47.9 L
EMD Value
₹95,820
Closing Date
5 Mar 2026, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR REPLACEMENT IMPROVEMENT OF LT ELECTRICAL PANELS INCLUDING STARTERS AND OTHER ACCESSORIES AND STANDBY DG SET AT VARIOUS WATER SUPPLY INSTALLATIONS AND CONNECTED WORKS IN THE AREA OF AGEU WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 1
2026_MES_751415_1
GE/WS/Token No-73 OF 2025-26
Open Tender
Civil Works
180 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹95,820
Yes
22 Jun 2026
5 Feb 2026
7 Mar 2026
5 Feb 2026
5 Mar 2026
20 Feb 2026
M/L maintenance and servicing of DG Set of any capacity complete by replacing the fuel filter, lubricating oil filter, replacement of air cleaner, change air cleaner elements, check coolant level & make up the same, drain the fuel filter & water separator, filling the starting batteries with electrolyte/distilled water to maintain the required specific gravity, replace the u/s brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, checking of exhaust leakage, governor, breathers etc, adjust/set the same for proper functioning of DG Set, checking of fuel, oil and water/ coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG Set with accessories as prescribed by the manufacturer and test for satisfactory running of DG set for two hour minimum at connected load and record shall be made in respect of RPM , oil pressure, oil temprature, coolant temprature, voltage, frequancy, load current, battery charging, fuel consumption & noise level etc complete all as specidied and directed. Note :- 1. Minor spare parts i.e. nut bolt, washer, petroleum jelly deemed to be included in the quoted unit rate of this item. 2. Major spare parts/Oil/Coolant etc will be measured and paid Seprately under respective of schedule 'A'. 3. DHPP will be issued by dept for testing only.
160 to 320 KVA Capacity
100 to 125 KVA Capacity
50 to 75 KVA Capacity (Note : For serial item no 1.01 to 1.03 Spares parts required shall be measured and paid separately under respective itms of Schedule as supply only.)
Supply only of following items for DG Sets Capacity of 160 KVA to 320 KVA (Required under Sl item No. 1.02 above) :-
Air Filter
Fuel Filter
Lubricating oil filter
Supply only of following items for DG Sets Capacity of 100 ot 125 KVA (Required under Sl item No. 1.03 above) :-
Air Filter
Fuel Filter
Lubricating oil filter
Supply only of following items for DG Sets Capacity of 50 to 75 KVA (Required under Sl item No. 1.04 above) :-
Air Filter
Fuel Filter
Lubricating oil filter
Supply & fixed in repair of Hose pipe set & Clips of water / coolent cooled radiator system for following capacities of DG set :-
50 KVA to 75 KVA DG set
100 KVA to 125 KVA to DG set
160 KVA to 320 KVA DG set
Supply and fixingof following items for DG Sets Capacity of 160 KVA to 320 KVA
Diesel return pipe
Ignition switch for starting DG set with key.
Diesel Fuel Hose pipe from diesel tank to fuel filter
Fuel injector pipe from fuel pump to Injector
Supply and fixingof following items for DG Sets Capacity of 100 KVA to 125 KVA
Diesel return pipe
Ignition switch for starting DG set with key.
Diesel Fuel Hose pipe from diesel tank to fuel filter
Fuel injector pipe from fuel pump to Injector
Supply and fixingof following items for DG Sets Capacity of 50 KVA to 75 KVA
Diesel return pipe
Ignition switch for starting DG set with key.
Diesel Fuel Hose pipe from diesel tank to fuel filter
Fuel injector pipe from fuel pump to Injector
Disconnection and dismantling the fuel injector pump assembly from its original position, repairing & servicing by cleaning / oiling / servicing of fuel injector pump assembly , removing and replacement fuel injector pump repair kit & fuel pipe including calibration complete & refixing the same complete all as specified and directed for following capacities of DG set :-
160 KVA to 320 KVA DG Set
100 to 125 KVA KVA Capacity
50 to 75 KVA Capacity
Dismantling and taking down radiator assy from engine of any capacity of repairs etc transporting of the radiator of capacity upto 320 KVA for repair/maintenance of rediator fins with the help of cleaning coil solution and cleaning to the radiator complete and removing the sediments and scales, corrosion etc by means of acid cleaning and high pressure water washing and air cleaning, repair to the leakage places by means of gas welding and including initial filling up coolant and re fixing after repairs including replacement of worn out nut bolts washers etc and testing complete all as specified and directed
Dismantling the water pump for the DG Set taking out the worn out parts, refixing the water pump after replacing water pump kit set for following capacities of DG set:-
50 KVA to 75 KVA DG set.
100 KVA to 125 KVA DG set.
160 KVA to 320 KVA DG set.
S&F in repair of RPM meter of upto 320 KVA DG set complete all as specified and directed.
S&F in repair of oil pressure Gauge of upto 320 KVA DG set complete all as specified and directed.
S&F in repair of oil temperature Gauge of upto 320 KVA DG set complete all as specified and directed.
S&F in repair of water temperature Gauge of upto 320 KVA DG set complete all as specified and directed.
Taking out following defective parts from Alternator of DG sets and supply and fixing new parts including testing of DG set complete all as directed :-
AVR unit complete suitable for 50 KVA to 75 KVA DG Set
AVR unit complete suitable for 100 KVA to 125 KVA DG Set
AVR unit complete suitable for 160 KVA to 320 KVA DG Set
Disconnection and taking out the turbo charger assembly complete from the Engine of any make of 100 KVA to125 KVA DG Set and taking to workshop, strip opening of turbo charger and replacement of turbo charger repair Kit , assembling the complete part of the turbo charger and fixing back to the engine the testing and commissioning for satisfactory working complete all as specified and directed.
M&L for replacement of fiexible coupling including coupling nuts, bolts & washers etc and proper alignment complete all as specified and directed at site suitable for DG sets of capacity :-
160 to 320 KVA Capacity
100 to 125 KVA Capacity
50 to 75 KVA Capacity
M&L repair/overhauling of self starter 12/24 Volt of any make/Capacity including replacement of minor items such as carbon brushes, nuts blts etc, complete all as specified directed for fully functional of self starter complete. (Note: All additional spares parts as required will be measured and paid separately as supply only)
Supply only spares parts suitable for self starter 12/24 V as mentioned below:-
Field coil
Armature
Clutch assembly
Supply & fix in repair of self starter assembly 24 volt complete for 100 KVA to 125 KVA DG set complete
Supply & fix in repair of self starter assembly 12 volt complete for 50 KVA to 75 KVA DG set complete
M&L cleaning oil fuel tank of DG sets of any make and capacity including replacement of fuel level indicating tube and markings of suitable quantity of OEM recommendation complete all as specified and directed.
S&F in replacement of Battery 12V 140AH complete all as specified and directed.
S&F in replacement of Battery 12V 120AH complete all as specified and directed.
S&F in replacement of Battery 12V 60AH complete all as specified and directed.
M&L battery lead copper conductor 25 Sqmm multi stranded PVC insulated with suitable terminals at both ends as per site requirement complete all as specified and directed.
Supply and replaced 'V belt' as per sample for DG sets of capacity complete all as specified and directed
50 to 75 KVA Capacity
100 to 125 KVA Capacity
160 to 320 KVA Capacity
Dismantling of alternator assembly of DG Set of capacity upto 125 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.
Dismantling of alternator assembly of DG Set of capacity exc 125 KVA but upto 320 KVA and taking out U/S Exitation winding and rewinding of exitation coil with supper enamelled copper winding complete all as per specified and directed.
Draining out the old u/s oil from the engine of DG set of any capacity cleaning the oil chamber and supply and filling new lubricant GENSET OIL complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container)
Supply and replacement coolant of approved make suitable for DG sets complete all as directed and specified. (Note: Lubricant oil shall be procured from approved make and in sealed container)
M & L for for repair of DG Control Panel of any description and in any position of capacity DG Set upto 200 KVA including checking AC/DC circuits, tightning of all power / control wiring connection and replacement of unserviceable control wiring with suitable size, single core, copper conductor, flexible, PVC insulated, unsheathed cable suitable upto 1100 volts confirming to IS-694, taking out, removing and replacement of unserviceable parts / spares / items to makefunctional including testing complete all as specified .
Material and labour for plate earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth lead 32mm x 6mm strip by means of bolts, nuts, check nuts and washers of galvanised iron or steel all surrounded by adequete quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, earth strip encased in 40 mm bore GI medium grade pipe, including providing watering pipe 20 mm bore GI pipe medium grade from bottom of the earth pit to the top of the electrode complete with earth pit in PCC 1:2:4 type B - O using 12 mm graded crushed stone aggregate, earth work and RCC cover Complete all as specified and shown in electrical plate number 3 of SSR part -1, incl dismantlimg of existing earth pit complete all as specified and directed. (Note: GI earth strip upto 7.5 RM from the test point shall be deemed included in quoted unit rate.)
M&L maintenance/repair at LT Control panel including cleaning in side the panel, tightening of all connection complete installed at pump house for centrifugal pump set/ borewell at different places in the area and replacement of spare parts as required during maintenance. (Note: Spare part will be measured and paid seperately under relevent item as supply only) complete upto 75 HP motor pump set (once in a month) with FASD starter and MCCB.
Material and labour for removing old paint by paint removers or burning off by blow lamps and cleaning with scrapers, any number of coats, any width or girth from the existing suction/ delivery pipe line including headers of any size and applying of painting to existing surcface by using spray gun with one coat of red oxide and two coat of synthetic enamel paints on existing suction/ delivery pipe lines, including Headers of any size using Blue/Red/Black colour as per site requirement complete all as specified and as directed.
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 350 Amp with breaking capacity 36 KA complete all as specified and directed
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 250 Amp with breaking capacity 36 KA. complete all as specified and directed
S&F in replacement moulded case circuit breakers 3 Pole 415 Volt adjustable type 200 Amp with breaking capacity 36 KA. complete all as specified and directed
S&F in replacement moulded case circuit breakers 4 Pole 415 Volt adjustable type 160 Amp with breaking capacity 36 KA. complete all as specified and directed
S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity 16 KA at 415 volts. complete all as specified and directed
Supply & Fixing in replacement MCCB 100 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.
Supply & Fixing in replacement MCCB 63 Amp 415 Volts, 16 KA, 4 pole, 50 Hz, with fixed thermal & fixed magnetic setting complete all as specified and as directed.
S&F in replacement offload changeover switch 4 pole 100 Amps in sheet enclosure compete all as specified and directed
S&F in replacement offload changeover switch 4 pole 250 Amps in sheet enclosure compete all as specified and directed
S&F in replacement offload changeover switch 4 pole 320 Amps sheet enclosure compete all as specified and directed
S&F in replacement offload changeover switch 4 pole 400 Amps sheet enclosure compete all as specified and directed
S&F in replacement 3 pole power contactor ML-3, 28-42 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed
S&F in replacement 3 pole power contactor ML-02, 20-32 Amps 415 volts, 50 HZ suitable for fixing in existing panel complete all as specified and directed
S&F in replacement 3 pole power contactor ML-1.5, 25 Amps suitable for fixing in existing panel complete all as specified and directed
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-1.5 FASD complete all as specified and directed
S&F in replacement of fully automatic star - delta straters in sheet enclosure type ML-2 FASD complete all as specified and directed
Supply and fixing in replacement of fully automatic star delta starter type ML-3 complete all as specified and directed
M&L in replacement of single phase preventor type VSP-II complete all as specified and directed
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Analog Type complete all as specified and directed
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Analog Type complete all as specified and directed
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and directed
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and directed
S & F in replacement of single phase indicator lamp LED type assembly as per site requirement complete.
M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 1.5 Sq mm complete all as specified and directed
M&L PVC insulated multistranded copper conductor wire, 1100 Volts in replacement, single core of size 2.5 Sq mm complete all as specified and directed
S&F in replacement of thermal over load relay type ML-1.5 relay range 10-16 Amps complete all as specified and directed
S&F in replacement of thermal over load relay type ML-2 relay range 20-32 Amps complete all as specified and directed
Material and labour for painting to existing surcface of NRV,sluice valves/Strainers valves of capacity 80 mm to 150 mm by using spray gun with one coat of red oxide and two coat of synthetic enamel paints as per colour code as mentioned below complete all as specified and directed. (Note: color shades are as under:- NRV colour - Black, Sluice Valve colour - Black)
Supply, Installation, commissioning and testing of Retrofitting of emission contro device/Equipements omn DG Set of 200 KVA of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 75% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5 & 10. Notes :- (i) System to be robust enough for cold start and startup oil emission such that there is no impect on overall maintenance cycle timelines. (ii) Operating back pressure limit to be < 3.3 KPa at Rated Load. (iii) Maintenace cycle to be 5-6 months or 500 Hrs whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25% load. (vi) Overall power consumption to be lower than 1% of DG Rated Power. (vii) The Emission control device /Equipement must be tested over an ISO -8178 5 mode D2 Cycle for equivelent KVA rating at any of the CPCB coliance Govt approved laboratories .
Supply, Installation, commissioning and testing of Retrofitting of emission contro device/Equipements omn DG Set of 380 KVA of any make alternator having a minimum specified particulate matter capturing efficiency of at least of 75% in 5 mode D2 cycle, reduction efficiency of CO, HC and PM 2.5 & 10. Notes :- (i) System to be robust enough for cold start and startup oil emission such that there is no impect on overall maintenance cycle timelines. (ii) Operating back pressure limit to be < 3.3 KPa at Rated Load. (iii) Maintenace cycle to be 5-6 months or 500 Hrs whichever is earlier. (iv) Noise levels to be within CPCB guidelines without silencer. (v) Passive regeneration to be achieved with max 10% duty cycle above 25% load. (vi) Overall power consumption to be lower than 1% of DG Rated Power. (vii) The Emission control device /Equipement must be tested over an ISO -8178 5 mode D2 Cycle for equivelent KVA rating at any of the CPCB coliance Govt approved laboratories .
Design, fabricate, supply, install, test and commissioning of factory made wall mountedsheet metal enclosure alongwith MCCB 400 Amps 4 pole 415 Volts Indoor type made out of 2.00 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front opening and locking arrangement on front .
An amount of Rs 1,01,517.00 shall be deducted from BOQ on account of schedule of credit
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_841583.xls
BOQ • 0.44 MB
tender.pdf
Tender Documents • 0.78 MB
Download all tender documents and submit your bid