Loading…
Loading…
Tender Value
₹1.7 Cr
EMD Value
₹3.5 L
Closing Date
16 Oct 2026, 4:00 pm
Project Director
Office of the Project Director, FRFCF-NRB, Kalpakkam
SITC of VRF System at FRFCF.
2026_BARC_927052_1
BARC/FRFCF/MECH/ACV/2026/T-071
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
FRFCF, Kalpakkam
Please refer tender document
8 documents required · 8 mandatory
₹0
₹3.5 L
23 Sept 2026
23 Sept 2026
28 Oct 2026
23 Sept 2026
16 Oct 2026
24 Sept 2026
24 Sept 2026 - 30 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of 12 HP Capacity Inverter Variable Refrigerant Flow System of Air-Cooled type comprising of inverter-controlled scroll compressor, condenser fan motor with variable speed controllers, fan, heat exchanger, accumulator, electronic expansion valve. The outdoor unit fan shall have an external static pressure of 80 Pa or more, with top discharge. The ODU should deliver COP of minimum 6.9 at 50% load at AHRI Condition and suitable for up to 75 m refrigerant piping between outdoor unit & the farthest indoor units. Allowable level difference between outdoor units & Indoor Units shall be minimum 20m, irrespective of the relative position of outdoor or indoor unit. The outdoor units shall be suitable to operate in an ambient temperature range of 53 Deg C DB in cooling mode only. The unit should be sized to deliver minimum rated capacity (including de-rated capacity) at ambient temperature of 39 Deg C DB. Complete refrigerant circuit, oil balancing / equalizing circuit shall be factory assembled & tested. The VRF Outdoor unit shall have an oil level sensor in the compressor to provide direct oil level sensing data to the main controller for efficient operation. The Outdoor Unit fan control shall include a function setting to remove excess dust automatically by rotating the Fan reversely to blow off the dust. The Outdoor Unit Heat Exchanger aluminum fins shall have Hydrophilic coating and additional factory applied corrosion resistant complex Epoxy Coating designed to perform in corrosive environments. The ODU shall be suitable for operation on 415 ±10% volts, 50Hz, 3 phase AC power supply | 9 | Nos | - | - |
| 2 | Supply, installation, testing and commissioning of 4TR cooling capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with inbuilt microprocessor, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cardless remote controller, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. | 21 | Nos | - | - |
| 3 | Supply, installation, testing and commissioning of 3TR cooling capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with inbuilt microprocessor, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cardless remote controller, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. | 2 | Nos | - | - |
| 4 | Supply, installation, testing and commissioning of 2.5TR cooling capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with inbuilt microprocessor, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation,cardless remote controller, etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. | 7 | Nos | - | - |
| 5 | Supply, installation, testing and commissioning of 2TR cooling capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with inbuilt microprocessor, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cardless remote controller etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. | 6 | Nos | - | - |
| 6 | Supply, installation, testing and commissioning of 1.5TR cooling capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with inbuilt microprocessor, synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cardless remote controller,etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. | 2 | Nos | - | - |
| 7 | Supply of Complete PCB board set up with all sensors, power terminal box with all connectors set and condensor motor suitable to the item No:1 (12 Hp outdoor unit) | 2 | Set | - | - |
| 8 | Supply of Complete PCB board set up with all sensors, evaporator motor with fan, electronic valve set up and drain pump with all connectors set suitable to the item No: 2 to 6 | 5 | Set | - | - |
| 9 | Supply & installation of Central Controller for each building (without desktop computer) with all necessary accessories like cables, connectors etc to and as per technical specification | 3 | Nos | - | - |
| 10 | Supply & installation of PC monitoring System (Central controller and Desktop computer) with all necessary accessories like cables, connectors etc to and as per technical specification | 1 | Set | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.24 MB
BOQ_974222.xls
BOQ • 0.26 MB
tenderdocument.pdf
Tender Documents • 0.86 MB
tender drawings_A0-FRFCF-73330-DD-1100-R1.pdf
Additional Documents • 1.03 MB
tender drawings_A0-FRFCF-73330-DD-1106-R0.pdf
Additional Documents • 0.50 MB
tender drawings_A0-FRFCF-73330-GA-1109-R0.pdf
Additional Documents • 0.47 MB
tender drawings_A0-FRFCF-73330-GA-1110-R0.pdf
Additional Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .