| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC | L1 | Accepted-AOC FOUND 1ST LOWEST | |
| 2 | L2₹13.2 L+₹4,543 (0.35%)Rejected-AOC | L2 | Rejected-AOC FOUND 2ND HIGHER | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹13.2 L
EMD Value
₹13,500
Closing Date
5 Oct 2023, 1:00 pmClosed
SUPERINTENDING ENGINEER, EDC, BANDA
CHILLA ROAD, INDIRA NAGAR, BANDA
The Erection work of 11 KV Lines due to bifercation of various 11 KV Feeders and Increasing Capacity of Power Transformer from 8 MVA to 10 MVA under Business Plan 2023-24 under EUDD, Banda
2023_DVVNL_834236_2
EDCBNDA-28/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BANDA
As per annexured
2 documents required · 2 mandatory
₹3,540
DVVNL
₹13,500
O/O SE, EDC, BANDA
29 May 2024
29 Sept 2023
5 Oct 2023
29 Sept 2023
5 Oct 2023
29 Sept 2023
30 Sept 2023
The following works under various places/Sub-Stations under BUSINESS PLAN SCHEME 2023-24 under EUDD, BANDA, including carriage of all required material from ESC Banda to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old line material/scraped from site to store centre, if any. Some petty Material like all types clamps, cable boxes, Aluminium tape, Lugs, hoisting clamp/cable hanging U clamps, Danger Board, Number Plate, Angle, HDPE/GI Pipes, nut-bolts & washers etc. of appropriate size & all plinth/fencing materials will be arranged by contractor on his own cost. The bidder shall be responsible for complete execution of the work under the scope of tender specification. Any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. Details of the work as given below ;-
Erecton work of 11 KV Lines due to bifercation of 11 KV Kanwara Payjal/Banda/Kalu Kuwan/Gayatri Nagar/Paprenda Feeders from Kanwara Payjal to Sukul Kuwan, Tulsi Nagar to Sukul Kuwan, Mandi Samiti to Hyundai agency, Tulsi Nagar to Mandi Samiti Left side & right side -
Safe cartage of 13 Mtr. long ST poles from store centre or from any other place to the respective site of work.
Safe cartage of line material viz. conductor, cable, G.I. earth wire, cross arm, angle, channel, insulator, clamps and other line material from store centre or from any other place to the respective site of work.
Erection of SP structure on 13 Mtr. long ST poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge.
Grouting of SP structure on 13 Mtr. long ST poles, including complete H.T./L.T. fittings as per RESSPO manual and as per direction of Engineer incharge. The support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 Cu. Mtr. each).
Erection and grouting of stay set with nozelling & binding as per norms.
Fixing of earthing rod as per RESSPO manual.
Laying, sagging, stringing, binding and jumpering etc. of ACSR Dog Conductor on the newly erected pole as per direction of supervising engineer/RESSPO manual.
Supply & fixing of M.S. T-Off Channel with clamp & N&B alongwith fitting of all accessories as per RESSPO manual (arranged by contractor at his own cost).
Supply & fixing of 11 KV Guarding Angle with clamp & N&B alongwith fitting of all accessories for guarding of lines as per RESSPO manual (arranged by contractor at his own cost).
Supply & fixing of Danger board with clamp alongwith fitting of all accessories as per RESSPO manual (arranged by contractor at his own cost).
Increasing Capacity of Power Transformer from 8 MVA to 10 MVA - 33/11 KV Sub-Station, TULSI NAGAR
Safe removal of following capacity old transformer from existing plinth as new transformer will be replaced by store and after installation reconnecting transformer to circuit -
8 MVA Transformer
Fixing of 11 KV Indoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost).
Fixing of 11 KV Outdoor type cable jointing kit of size 3x300 sq.mm. with fitting of all accessories as per RESSPO manual (arranged by tenderer at his own cost).
Repairing of plinth for 10 MVA Power Transformer as per site condition, if required. The contractor shall be responsible to complete the work as per direction of Supervising Engineer.
Making two body earthing and one neutral earthing for transformers as per standard RESSPO norms.
Delta Earthing.
Boring type earthing upto water level (90 Mtr.).
Repairing cable trench from switchgear to transformer and upto 33 KV breacker and laying of 11 KV XLPE Cable 3x300 Sq.mm. (50 Mtr.)
Replacement of OTI, WTI relay cable connections, if required.
4 Core 2.5 Sq.mm.
2 Core 2.5 Sq.mm.
Installation of 33 KV breacker
Installation of 33 KV CT
Installation of 33 KV Control panel
Interconnection with Control panel for proper tripping.
MAA ELECTRICAL ENERGY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .