Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹3.6 Cr
Closing Date
31 Jan 2022, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sonudeep
POWERGRID, Eastern Region-I Regional Headquarter, Shastrinagar, Patna-800023
Construction of Residential Quarters at 400kV GIS Chandwa substation.
5002002028/OTHERS/DOM/D01 - ER1 RHQ -2
Open
Civil Works - Buildings
Works
400kV GIS Chandwa substation
₹12,500
29 Dec 2021
29 Dec 2021
31 Jan 2022
29 Dec 2021
31 Jan 2022
29 Dec 2021
Name of Package : Construction of Residential Quarters at 400kV GIS Chandwa substation
Package No : NIT-403
Specification No. : 5002002028/OTHERS/DOM/D01 - ER1 RHQ -2
Contract Period 12 Months
: Attachments : General guidelines for filling up the Attachments : CT Analyser -NIT-403 :
Construction of Residential Quarters at 400kV GIS Chandwa substation
Specification No.: 5002002028/OTHERS/DOM/D01 - ER1 RHQ -2
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(QR), 4, 5, 6, 7, 9, 10, 11, 12, 13,14, 15, 16, 17 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as per proforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. This attachment is not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of Residential Quarters at 400kV GIS Chandwa substation
5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Individual Firm 1
Licensee of a Manufacturer 2
Enter following details of the bidder Representative of a Manufacturer
Specify type of Bidder [Select from drop down menu] #REF!
Name of Lead Partner …….. …… ………. ……….
Address of Registered Office …….. …… ………. ……….
Name of Other Partner …….. …… ………. ……….
Printed Name …….. …… ………. ………. 01/Dec/25
Designation …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-3(JV) NIT-403 #REF! NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials #REF!
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
Name(s) and Addresse(s) of other partner(s)
Name : #REF! #REF!
Address : #REF! #REF!
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : …….. …… ………. ………. 0
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-3(QR) NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name : …….. …… ………. ……….
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4(A) NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
S.No. For Equipment Item Description Unit Quantity
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-4(B) NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. "Saudamini", Plot No. 2, Sector 29
…….. …… ………. ………. Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-5 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-5 NIT-403
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-6 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-6 NIT-403
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-7 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Details of Alternative Bid)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
No Alternative Bid
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-8 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Manufacturer's Authorization Form)
Contracts and Materials
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001 Name of Manufecture Name/Description of Goods Factory Address Name & Address of Bidder package name alongwith project name
…(insert name of the Manufacturer) .. …(insert name and/or description of the goods) … ..(insert address of factory) .. …….. …… ………. ………. Construction of Residential Quarters at 400kV GIS Chandwa substation
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at ..(insert address of factory) .., , , do hereby authorize …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ……….(hereinafter, the “Bidder”) to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Construction of Residential Quarters at 400kV GIS Chandwa substation including the above plant & equipment or other goods produced by us. 0
WE …(insert name of the Manufacturer) .. who are established and reputable manufacturers of …(insert name and/or description of the goods) …. having production facilities at We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations.
We hereby extend our full guarantee and warranty for the above specified goods offered supporting the supply by the Bidder against these Bidding Documents, and duly authorize said Bidder to act on our behalf in fulfilling these guarantee and warranty obligations. We also hereby declare that we and …….. …… ………. ………. have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability). We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract. ..(insert address of factory) .., , , do hereby authorize …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ………., …….. …… ………. ……….(hereinafter, the “Bidder”) We also hereby declare that we and …….. …… ………. ………. have entered into a formal relationship in which, during the duration of the Contract (including warranty/defects liability).
For and on behalf of the …(insert name of the Manufacturer) .. to submit a bid, and subsequently negotiate and sign the Contract with you against IFB for Construction of Residential Quarters at 400kV GIS Chandwa substation including the above plant & equipment or other goods produced by us. We, the Manufacturer or Producer, will make our technical and engineering staff fully available to the technical and engineering staff of the successful Bidder to assist that Bidder, on a reasonable and best effort basis, in the performance of all its obligations to the Purchaser under the Contract.
In the capacity of
Date : Printed Name : …….. …… ………. ……….
Note :1 The letter of Undertaking should be on the letterhead of the Manufacturer and should be signed by a person competent and having Power of Attorney to legally bind the Manufacturer. It shall be included by the bidder in its bid.
2 Above undertaking shall be registered or notarized so as to be legally enforceable.
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-9 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Work Completion Schedule)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby declare that the following Delivery Schedule shall be followed by us for the subject Package i.e., Construction of Residential Quarters at 400kV GIS Chandwa substation for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
1 Submission of drawings for Approval
2 Production of samples for type testing
3 Completion of type tests
4 Commencement of Commercial Production
5 Offer of material for pre-despatch testing and inspection
6 Commencement of shipment
1 Completion of shipment (Receipt at final destination Site)
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-10 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Guarantee Declaration)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-11 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-11 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name of Other Partner To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-12 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Price Adjustment Data)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Construction of Residential Quarters at 400kV GIS Chandwa substation The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index * Value of index as 30 days prior to date set for opening of bids as on **
1 EC grade aluminium ingots, co-eifciant a = 0.65 CACMAI
High Tensile Galvanised Steel wires , co-efficient b = 0.15 CACMAI FALSE FALSE
High Carbon Steel Rods , co-efficient b = High Tensile Galvanised Steel wires , co-efficient b =
High Grade Electrolytic Zinc , co-efficient c =
3 Labour, Co-efficient l= 0.05 Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
Note: * Indicate the publisher of the index.
** Indicate the date of indices for which the values are being furnished.
^ For bidders who intend to quote their prices based on High Tensile Galvanised Steel wire, the coefficient for the same (i.e. coefficient ’b’ for High Tensile Galvanised Steel wire) shall be 0.15 and coefficient ‘c’ shall not be applicable.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-13 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-14 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
Bidders are required to submit 02 copy of Integrity Pact as per format enclosed at vol-I
Date : Printed Name : …….. …… ………. ……….
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact (if required)is attached in Vol-I of Bid Documents.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (n).
Specification No. : 5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-15 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Information for E-payment, PF details and declaration for Micro/Small and Medium Enterprise)
Bidder's Name and Address (Sole Bidder [Individual Firm]): To:
Contracts and Materials
Name: …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address: …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidyut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
We are furishing the following details of Statutory Registration Numbers and details of Bank for electronic payment
1 Name of the Supplier/ Contractor in whose favour payment is to be made
2 Address with PIN Code and State
Registered Office:
Correspondence Address:
3 Status- Company/others [Declaration of Micro/ Small/Medium Enterprtise ]
4 Permanent Account [PAN] No.
5 Goods & Services Tax [GST] No.
6 PF Registration No. Of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Telephone No(s)
10 Bank Details for Electronic Payment
Name ofthe Bank:
Address of the Branch:
Type of Account: Savings/Current
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that thepayment onaccount of this Contract, in the event of Award, be made in the above account maintained in theabove mentioned Bank.
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-16 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
(Additional Information)
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the (Lead Partner) : …….. …… ………. ……….
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Description of the plant for carrying out the work
Bidders should provide information of the plant(s) for carrying out the work including the proposal of manufacturing methods in sufficient detail to demonstrate the adequacy of the bidder’s proposals to meet the technical specification.
4.0 OTHER INFORMATION
4.1 Current Contract Commitments of works in progress
Bidders should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Type of Conductor Ordered Quantity as per Contract Balance Quantity to be supplied as on Completion Period for balance quantity
Commencement Completion
4.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Attachment-17 NIT-403
Construction of Residential Quarters at 400kV GIS Chandwa substation
Bidder’s Name and Address (Lead Partner) : To:
Contracts and Materials
Name : …….. …… ………. ………. Power Grid Corporation of India Ltd.,
Address : …….. …… ………. ………. Eastern Region Transmission System-I
…….. …… ………. ………. Vidut Board Colony,
…….. …… ………. ………. Shastri Nagar Patna 800023
Date : Printed Name : …….. …… ………. ……….
Specification No. :5002002028/OTHERS/DOM/D01 - ER1 RHQ -2 Bid Form 1st Envelope NIT-403 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contracts and Materials 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
Eastern Region Transmission System-I 11 eleven 11 th 11 November
Vidut Board Colony, 12 twelve 12 th 12 December
Shastri Nagar Patna 800023 13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Construction of Residential Quarters at 400kV GIS Chandwa substation 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. dated 00/01/1900 the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
(b) Attachment 2(NIT-403) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 07 (seven) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3(NIT-403) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3(c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 22 th
#REF! Applicable 23 th
#REF! Not Applicable 24 th
(d) Attachment 4(NIT-403) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. 25 th
(e) Attachment 5(NIT-403) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 6(NIT-403) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(g) Attachment 7(NIT-403) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. [NOT APPLICABLE] 28 th
(h) Attachment 8(NIT-403) : Manufacturer’s Authorisation Forms. 29 th
(i) Attachment 9(NIT-403) : Work Completion Schedule. 30 th
(j) Attachment 10(NIT-403): Guarantee Declaration. 31 st
(k) Attachment 11(NIT-403): Information regarding ex-employees of Purchaser in our firm.
(l) Attachment 12(NIT-403): Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.[NOT APPLICABLE]
(m) Attachment 13(NIT-403): Declaration regarding Social Accountability.
(n) Attachment 14(NIT-403): Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.[NOT APPLICABLE]
(o) Attachment 15(NIT-403): Information for E-payment, PF Details & declaration regarding Micro/Small & Medium Enterprises.
(p) Attachment 16(NIT-403): Additional Information.
(q) Attachment 17(NIT-403): Declaration.
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Goods, in and outside of India.
4.1 100% of applicable Taxes and Duties, which are payable by the Purchaser under the Contract, shall be reimbursed by the Purchaser after despatch of goods on production of satisfactory documentary evidence by the Supplier in accordance with the provisions of the Bidding Documents.
4.3 We also understand that, in case of award on us, you shall reimburse to us octroi/entry tax as applicable for destination site/state on all items of supply. Further, Service Tax, if applicable, for the services to be rendered by us, the same is included in our bid price in Second Envelope.
4.4 We confirm that we shall also get registered with the concerned Sales Tax Authorities, in all the states where the project is located.
5.0 Construction of the Contract
5.1 We declare that we have studied clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us the Contracts covering all goods and related services.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
[a] Bid document Fee Clause 3.0 of SCC.
[b] Bid Security/ Bid Guarantee Clause No 13.0, ITB, Section -II, and cl. 4.0 of SCC, Section-IV, Volume-I.
[c] Terms of Payment Clause No.64.0, Conditions of Contract (GCC) & Clause 12.0, SCC
[d] Contract Performance Guarantee/Performance Security Clause No.14, Section GCC, Vol.-I, Conditions of Contract & Clause 13.0 of SCC, Section-IV, Vol-I.
[e] Liquidated Damages Clause No 11.0 of SCC, Volume-I
[f] Price & Price Basis Clause No 11.0 of ITB,
[g] Guarantee & Defect Liability Period Cl.No.45.0 & 46.0 Section. GCC, Vol. I, Conditions of Contract & Clause 9.0 of SCC, Volume- I
[h] Work schedule Clause No. 10.0 of SCC, Volume -I
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide an Advance Payment Security and Performance Security(ies) in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …… ………. ……….
Date : Printed Name : …….. …… ………. ……….
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 (NIT-403) : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
ElectronicForms™
View - Template of ElectronicForm™
To close this Screen, click on the [Close] button located on the bar above, or at the bottom of the Screen
Template of ElectronicForm™
Relevant Bid-Part Techical
ElectronicForm™ Template ID 7PG-2010-FT000010
Template Reference TECHNO-COMMERICIAL (First Envelope)
Template Description Tower Package NIT-403 Specification No. : 5002002028/OTHERS/DOM/D01 - ER1 RHQ -2
Construction of Residential Quarters at 400kV GIS Chandwa substation
Bidders's Name #REF!
Section-2 (Outline of Requirements)
* 1 Integrity Pact Details
Submitted (Doc. Code No. DC-9008-April-2009-Rev-0) Yes
* 2 BID SECURITY DETAILS
2 (a) Submitted Yes
* 2 (b) Bid Security No.
* 2 (c) Issued by (Name of Bank)
* 2 (d) Bid Security Amount 0 0.00
* 2 (e) Valid upto
* 1. AUTHORIZED SIGNATORY (Sole Bidder / Lead Partner of JV)
1 (b) Designation …….. …… ………. ……….
2. AUTHORIZED SIGNATORY (Other Partner of JV)
(If Bidder is JV)
2 (a) Name #REF!
2 (b) Designation #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of the Package Construction of Residential Quarters at 400kV GIS Chandwa substation
Construction of Residential Quarters at 400kV GIS Chandwa substation
1 Fill only Green shaded cells in Details and Schedule-I.
2 All the cells in Summary will be auto filled, therefore no cell is required to be filled in that sheet.
3 Instructions ,if any will be displayed automatically after selecting the cell.
Click here to proceed.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
Construction of Residential Quarters at 400kV GIS Chandwa substation
Enter the following details of the bidder
Name of the bidder
Alternative E-mail
Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - Ground Floor ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
2 (a) 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door
Beam size 250 x 600
Roof Beam Size 250 x 450
Along Grid F (SB1) 1 3.05 0.25 0.32 0.24
Beam size 125 x 450
Total Length of 250 x 600 beam 124.65
Total Length of 250 x 450 beam 104.63
Total Length of 125 x 450 beam 3.00
2(b) 5.3 Providing RCC (1:1.5:3) in Roof slab, Landing excluding the cost of centring, shuttering and reinforcement
Slab Beam Bottom 1 36.10 0.60 0.10 2.17
Slab beam top 1 36.10 0.60 0.15 3.25
Balcony projection 2 2.20 0.93 0.15 0.61
Deductions for openings (stair) -1 3.33 2.55 0.13 -1.10
Behind Stair -1 5.15 2.55 0.13 -1.71
2© 5.3 Providing RCC (1:1.5:3) in Staircase excluding the cost of centring, shuttering and reinforcement
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 90.33
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for:
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Slab Beam Bottom 1 36.10 0.60 21.7
Slab beam top 1 36.10 0.60 21.7
Balcony projection 2 2.20 0.93 4.1
box window 1 1.15 0.70 0.8
Deductions for openings (stair) -1 3.33 2.55 -8.5
Lift anf duct -2 1.95 1.98 -7.7
Behind Stair -1 5.15 2.55 -13.13
b 5.9.5 Lintel, Beam
c 5.9.19 Chajja
d 5.9.6 Column and Stiffener
Waist slab 2 3.00 1.20 7.2
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
Inner wall (125 mm thk.) 1 10.55 2.55 26.9
Deduction for openings
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:3) Ceiling plaster
Slab Beam Bottom 1 36.10 0.60 21.66
Slab beam top 1 36.10 0.60 21.66
Balcony projection 2 2.20 0.93 4.07
box window 1 1.15 0.70 0.81
Deductions for openings (stair) -1 3.33 2.55 -8.48
Lift anf duct -2 1.95 1.98 -7.70
Behind Stair -1 5.15 2.55 -13.13
8 13.4.2 12 mm (1:6) cement Plaster
internal plaster
Guard room 1 15.25 2.87 43.77
Lift and duct 1 15.70 3.00 47.10
lift and duct outer 1 14.55 2.87 41.76
Col. 20 mm plaster -22.44
Total 12 mm plaster 460.93 Sq m 263.55 235.31 108,463
9 13.5.2 15 mm Cement plaster of rough side of single or half brick wall of mix 1:6 ( 1 cement:6 coarse sand)
Length of 125 the. Wall ( one side) 1 5.05 2.55 12.9
10 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 1 11.60 3.00 34.80
11 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 60.00 60.0 meter 57.75 51.56 3,094
12 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Stair Tread ) Flooring 18 1.20 0.25 5.4
( Stair Landing) 1 2.55 1.20 3.1
Stair room 1 2.55 3.70 9.4
13 11.20 Chequerred precast cement concrete tiles 22 mm thick in footpath& courtyard, jointed with neatcement slurry mixed with pifment to match the shade of tiles, including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4( 1 cement : 4 coarse sand)
11.20.2 Medium shade pigment using 50 % white cement 50 % Grey cement
Q = Total plot area - other flooring 810.5
14 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Providing and laying 60x60 cm Vitrified floor tiles over 20 mm thick cement mortar (1:4) all complete
15 11.37 Providing and laying Ceramic Glazed Floor tiles 300x300 in skirting of approved shade over 20 mm thick (1:4) cement mortar
16 11.23 Marble stone flooring with 18 mm thick marble stone as per sample of marble approved by engineer in charge, over 20 mm ( average) thick base of cement mortar1:4(1 cement:4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completewith:
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.1 Rajnagar Plain white marble
Lobby Skirting 1 9.00 0.15 1.4
Two side col. 5 1.00 0.15 0.8
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade
Lift wall 1 1.15 2.10 2.4
18 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Stair riser 20 1.20 0.15 3.6
landing 1 2.55 0.15 0.4
landing 2 1.20 0.15 0.4
Stair room 1 9.95 0.10 1.0
19 11.46.2 Providing and laying Vitrified tiles in Skirting, Riser of steps over 12 mm cement mortar (1:3) all complete
Guard room 1 12.65 0.10 1.3
20 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
21 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
22 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmiumplated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beadingand hinges will be paid for separately).
9.131.1 25 mm thick
23 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.50 Kg Per Meter )
Duct door 1 4.95 4.95
24 9.21 Providing and fixing ISI marked flush door shutters confirming to IS:2202(PartI) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneer on both faces of shutters.
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
25 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required)extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size accordingto uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
26 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
27 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 9 9.0 No 187.75 167.63 1,509
28 2407 5.5mm Glass pane in door / window shutter
29 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
30 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
31 9.98 Providing and fixing aluminium pull bolt lock,ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS; 1868) transparent or dyed to rewuired colour and shade with necessary screws bolts, nut and washers etc. complete 3 3.0 each 85.95 76.74 230
32 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
33 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper 1 1.0 no 62.05 55.40 55
34 10.28 Providing & Fixing Stainless steel (grade 304) railing made of hollow tubes all complete
@ 5 Kg per metre ( stair railing) 2 3.76 7.5
35 13.26 Providing and applying POP Putty of average thickness 2 mm of approved brand and manufacture
As per 12 mm inner plaster 12.9
As per 15 mm plaster 74.8
As per 6 mm plaster 353.8
Deduction ( wall tiles area ) -13.9
36 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as wall putty area 427.6 Sq m 113.90 101.70 43,486
37 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as 20mm plaster area 132.0 Sq m 161.15 143.88 18,997
38 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work
39 10.18 Providing and fixing circular cast iron box for ceiling fan all complete 16 16 No 172.25 153.79 2,461
40 9.47 Providing and fixing nickel plated M.S pipe curtain rods with nickel plated brackets
9.47.1 20 mm dia( Heavy type) 3.60 3.6 meter 155.65 138.97 500
41 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with flats, square or round bars etc. including priming cost with approved steel primer all complete.
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc. ( @ 24 kg Per sqm) 4.66 111.8 kg 183.50 163.84 18,314
42 10.3 providing and fixing in position collapsible steel shutters with vertical chanels 20 x 10 x 2 mm and braced with flat iron diagonals 20 x 5 mm size, with top and bottom rail of T iron 40x40x6 mm, with 40 mm dia stee pulleys, complete with bolts, nuts, locking arrangement, stoppers,handles,including applying a priming cost of approved steel primer 7.80 2.40 19 Sqm 8,670.50 7,741.52 144,921
Total excl. taxes 3676093.73
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - First Floor ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
2 (a) 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door
Beam size 250 x 600
Roof Beam Size 250 x 450
Along Grid F (SB1) 1 3.05 0.25 0.32 0.24
Beam14 ( Lift & cut out) 4 1.95 0.25 0.32 0.62
Beam size 125 x 450
Total Length of 250 x 600 beam 129.40
Total Length of 250 x 450 beam 80.13
Total Length of 125 x 450 beam 9.80
2(b) 5.3 Providing RCC (1:1.5:3) in Roof slab, Landing excluding the cost of centring, shuttering and reinforcement
Slab Beam Bottom 1 15.15 0.60 0.10 0.91
Slab beam top 1 3.78 0.60 0.15 0.34
Balcony projection 3 2.28 0.93 0.15 0.95
Deductions for openings (stair) -1 3.33 2.55 0.13 -1.10
Behind Stair -1 5.15 2.55 0.13 -1.71
2© 5.3 Providing RCC (1:1.5:3) in Staircase excluding the cost of centring, shuttering and reinforcement
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 88.46
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for: 0
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform 0
Slab Beam Bottom 1 15.15 0.60 9.1
Slab beam top 1 3.78 0.60 2.3
Balcony projection 3 2.28 0.93 6.3
Deductions for openings (stair) -1 3.33 2.55 -8.5
Lift anf duct -2 1.95 1.98 -7.7
Behind Stair -1 5.15 2.55 -13.13
b 5.9.5 Lintel, Beam
c 5.9.19 Chajja
d 5.9.6 Column and Stiffener
Waist slab 2 3.00 1.20 7.2
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Outer wall 250mm thk.
Along Grid-A 1 9.50 0.25 2.40 5.7
Along grid B 1 4.85 0.25 2.40 2.9
Along grid E 1 2.45 0.25 2.40 1.5
Along grid H 1 8.65 0.25 2.40 5.2
Total length of 250 the. Outer wall 67.58
Inner wall 250 mm thk.
Lift and cut out 1 7.80 0.25 2.55 5.0
Total length of 250 the. Inner wall 22.05
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
Inner wall (125 mm thk.)
Along grid B 1 1.98 2.40 4.7
Along grid C 1 13.95 2.40 33.5
Along grid E 1 3.10 2.40 7.4
Along grid G 1 5.90 2.55 15.0
Along grid 4 1 3.40 2.55 8.7
Along grid 6 1 2.87 2.55 7.3
Along Grid 10 1 6.55 2.55 16.7
Total length of 125 the.inner. wall 68.90
Outer wall 125 mm thk.
Along grid F 1 2.55 2.55 6.5
Along grid H 1 8.00 2.40 19.2
Along grid 11 1 2.88 2.40 6.9
Total length of 125 the.outer . wall 18.93
Deduction for openings
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:3) Ceiling plaster
Slab Beam Bottom 1 15.15 0.60 9.09
Slab beam top 1 3.78 0.60 2.27
Balcony projection 3 2.28 0.93 6.31
Deductions for openings (stair) -1 3.33 2.55 -8.48
Lift anf duct -2 1.95 1.98 -7.70
Behind Stair -1 5.15 2.55 -13.13
8 13.4.2 12 mm (1:6) cement Plaster
Length of 250 the outer wall ( inner face ) as per 250 the. Brick work 1 67.58 2.87 194.0
Length of 250 the. Inner wall ( both face ) as per 250 the. Brick work 2 22.05 2.87 126.6
Deduction for openings
Length of 125 the. Wall ( one side plaster ) as per 125 the. Brick work 1 68.90 2.87 197.7
Deduction D0 -1 1.50 2.10 -3.2
Total 12 mm plaster 446.1 Sq m 263.55 235.31 104,966
9 13.5.2 15 mm Cement plaster of rough side of single or half brick wall of mix 1:6 ( 1 cement:6 coarse sand)
Length of 125 the. Wall ( one side) as per 125 the. Brick work 1 68.90 2.87 197.7
10 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 250 mm thk 1 67.58 3.00 202.8
Outer Wall 125mm thk 1 18.93 3.00 56.8
11 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 200.00 200.0 meter 57.75 51.56 10,313
12 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Stair Tread ) Flooring 18 1.20 0.25 5.4
( Stair Landing) 1 2.55 1.20 3.1
13 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Providing and laying 60x60 cm Vitrified floor tiles over 20 mm thick cement mortar (1:4) all complete
between bed room 2 1.50 1.75 5.25
Office cum store 1 4.97 3.30 16.42
common hall / recreation 1 7.93 3.30 26.15
14 11.37 Providing and laying Ceramic Glazed Floor tiles 300x300 in skirting of approved shade over 20 mm thick (1:4) cement mortar
15 11.23 Marble stone flooring with 18 mm thick marble stone as per sample of marble approved by engineer in charge, over 20 mm ( average) thick base of cement mortar1:4(1 cement:4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completewith:
11.23.2 Rajnagar Plain
16 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.1 Rajnagar Plain white marble
Kit Skirting 2 9.90 0.10 2.0
Lobby Skirting 1 9.63 0.10 1.0
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade
Lift wall 1 1.15 2.10 2.4
18 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Stair riser 20 1.20 0.15 3.6
landing 1 2.55 0.15 0.4
landing 2 1.20 0.15 0.4
19 11.46.2 Providing and laying Vitrified tiles in Skirting, Riser of steps over 12 mm cement mortar (1:3) all complete
Drawing & Din 2 20.25 0.10 4.1
Office cum store 1 15.61 0.10 1.6
Common Hall / Recreation 1 53.86 0.10 5.4
20 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
21 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
22 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmiumplated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beadingand hinges will be paid for separately).
9.131.1 25 mm thick
23 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.50 Kg Per Meter )
24 9.21 Providing and fixing ISI marked flush door shutters confirming to IS:2202(PartI) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneer on both faces of shutters.
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
25 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required)extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size accordingto uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
26 9.147A.6 Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm)
27 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
28 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 48 48.0 No 187.75 167.63 8,046
29 2407 5.5mm Glass pane in door / window shutter
30 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
31 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
32 9.98 Providing and fixing aluminium pull bolt lock,ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS; 1868) transparent or dyed to rewuired colour and shade with necessary screws bolts, nut and washers etc. complete 10 10.0 each 85.95 76.74 767
33 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
34 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper 13 13.0 no 62.05 55.40 720
35 10.28 Providing & Fixing Stainless steel (grade 304) railing made of hollow tubes all complete
@ 5 Kg per metre ( stair railing) 2 3.76 7.5
Balcony railing 2 9.43 18.9
36 13.26 Providing and applying POP Putty of average thickness 2 mm of approved brand and manufacture
As per 12 mm inner plaster 446.1
As per 15 mm plaster 197.7
As per 6 mm plaster 334.8
Deduction ( wall tiles area ) -97.3
37 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as wall putty area 881.3 Sq m 113.90 101.70 89,626
38 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as outer plaster area 259.5 Sq m 161.15 143.88 37,342
39 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work
40 10.18 Providing and fixing circular cast iron box for ceiling fan all complete 22 22 No 172.25 153.79 3,383
41 9.47 Providing and fixing nickel plated M.S pipe curtain rods with nickel plated brackets
42 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with flats, square or round bars etc. including priming cost with approved steel primer all complete.
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc. ( @ 24 kg Per sqm) 34.22 821.3 kg 183.50 163.84 134,568
43 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Face area 2 7.30 0.45 6.6
Face area 2 7.36 0.45 6.6
Face area 1 9.46 0.45 4.3
Face area 1 9.82 0.45 4.4
TOTAL excl. taxes 4,166,385
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - 2ND Floor ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate *100/112 Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
2 (a) 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door
Beam size 250 x 600
Roof Beam Size 250 x 450
Along Grid F (SB1) 1 3.05 0.25 0.32 0.24
Beam14 ( Lift & cut out) 4 1.95 0.25 0.32 0.62
Beam size 125 x 450
Total Length of 250 x 600 beam 129.40
Total Length of 250 x 450 beam 80.13
Total Length of 125 x 450 beam 9.80
2(b) 5.3 Providing RCC (1:1.5:3) in Roof slab, Landing excluding the cost of centring, shuttering and reinforcement
Slab Beam Bottom 1 3.78 0.60 0.10 0.23
Slab beam top 1 3.78 0.60 0.15 0.34
Balcony projection 3 2.28 0.93 0.15 0.95
Deductions for openings (stair) -1 3.33 2.55 0.13 -1.10
Behind Stair -1 5.15 2.55 0.13 -1.71
2© 5.3 Providing RCC (1:1.5:3) in Staircase excluding the cost of centring, shuttering and reinforcement
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 87.94
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for:
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Slab Beam Bottom 1 3.78 0.60 2.3
Slab beam top 1 3.78 0.60 2.3
Balcony projection 3 2.28 0.93 6.3
Deductions for openings (stair) -1 3.33 2.55 -8.5
Lift anf duct -2 1.95 1.98 -7.7
Behind Stair -1 5.15 2.55 -13.13
b 5.9.5 Lintel, Beam
c 5.9.19 Chajja
d 5.9.6 Column and Stiffener
Waist slab 2 3.00 1.20 7.2
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Outer wall 250mm thk.
Along Grid-A 1 6.38 0.25 2.40 3.8
Along grid B 1 2.13 0.25 2.40 1.3
Along grid E 1 2.45 0.25 2.40 1.5
Along grid H 1 8.65 0.25 2.40 5.2
Total length of 250 the. Outer wall 52.55
Inner wall 250 mm thk.
Lift and cut out 1 7.80 0.25 2.55 5.0
Total length of 250 the. Inner wall 22.05
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
Inner wall (125 mm thk.)
Along grid B 1 6.68 2.40 16.0
Between Grid A & B 1 10.65 2.55 27.2
Along grid C 1 13.95 2.40 33.5
Along grid E 1 3.10 2.40 7.4
Along grid G 1 5.90 2.55 15.0
Along grid 4 1 3.40 2.55 8.7
Along grid 6 1 7.18 2.55 18.3
along grid 8 1 3.85 2.55 9.8
Along Grid 10 1 3.40 2.55 8.7
Total length of 125 the.inner. wall 89.50
Outer wall 125 mm thk.
Along grid H 1 8.00 2.40 19.2
Along grid F 1 2.55 2.55 6.5
Along grid 10 1 5.80 2.40 13.9
Total length of 125 the.outer . wall 29.18
Deduction for openings
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:3) Ceiling plaster
Slab Beam Bottom 1 3.78 0.60 2.27
Slab beam top 1 3.78 0.60 2.27
Balcony projection 3 2.28 0.93 6.31
Deductions for openings (stair) -1 3.33 2.55 -8.48
Lift anf duct -2 1.95 1.98 -7.70
Behind Stair -1 5.15 2.55 -13.13
8 13.4.2 12 mm (1:6) cement Plaster
Length of 250 the outer wall ( inner face ) as per 250 the. Brick work 1 52.55 2.87 150.8
Length of 250 the. Inner wall ( both face ) as per 250 the. Brick work 2 22.05 2.87 126.6
Deduction for openings
Length of 125 the. Wall ( one side plaster ) as per 125 the. Brick work 1 89.50 2.87 256.9
Total 12 mm plaster 455.3 Sq m 263.55 235.31 107,130
9 13.5.2 15 mm Cement plaster of rough side of single or half brick wall of mix 1:6 ( 1 cement:6 coarse sand)
Length of 125 the. Wall ( one side) as per 125 the. Brick work 1 89.50 2.87 256.9
10 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 250 mm thk 1 52.55 3.00 157.7
Outer Wall 125mm thk 1 29.18 3.00 87.5
11 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 200.00 200.0 meter 57.75 51.56 10,313
12 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Stair Tread ) Flooring 18 1.20 0.25 5.4
( Stair Landing) 1 2.55 1.20 3.1
13 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Providing and laying 60x60 cm Vitrified floor tiles over 20 mm thick cement mortar (1:4) all complete
between bed room 2 1.50 1.75 5.25
14 11.37 Providing and laying Ceramic Glazed Floor tiles 300x300 in skirting of approved shade over 20 mm thick (1:4) cement mortar
15 11.23 Marble stone flooring with 18 mm thick marble stone as per sample of marble approved by engineer in charge, over 20 mm ( average) thick base of cement mortar1:4(1 cement:4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completewith:
11.23.2 Rajnagar Plain
16 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.1 Rajnagar Plain white marble
Kit Skirting 2 9.90 0.10 2.0
Kit Skirting 1 10.90 0.10 1.1
Lobby Skirting 1 9.63 0.10 1.0
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade
Lift wall 1 1.15 2.10 2.4
18 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Stair riser 20 1.20 0.15 3.6
landing 1 2.55 0.15 0.4
landing 2 1.20 0.15 0.4
19 11.46.2 Providing and laying Vitrified tiles in Skirting, Riser of steps over 12 mm cement mortar (1:3) all complete
Drawing & Din 2 20.25 0.10 4.1
20 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
Above kit platform 2 4.80 0.60 5.8
21 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
22 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmiumplated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beadingand hinges will be paid for separately).
9.131.1 25 mm thick
23 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.50 Kg Per Meter )
24 9.21 Providing and fixing ISI marked flush door shutters confirming to IS:2202(PartI) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneer on both faces of shutters.
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
25 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required)extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size accordingto uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
26 9.147A.6 Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm) 0.00
27 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
28 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 52 52.0 No 187.75 167.63 8,717
29 2407 5.5mm Glass pane in door / window shutter
30 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
31 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
32 9.98 Providing and fixing aluminium pull bolt lock,ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS; 1868) transparent or dyed to rewuired colour and shade with necessary screws bolts, nut and washers etc. complete 13 13.0 each 85.95 76.74 998
33 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
34 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper 22 22.0 no 62.05 55.40 1,219
35 10.28 Providing & Fixing Stainless steel (grade 304) railing made of hollow tubes all complete
@ 5 Kg per metre ( stair railing) 2 3.76 7.5
Balcony railing 2 9.43 18.9
36 13.26 Providing and applying POP Putty of average thickness 2 mm of approved brand and manufacture
As per 12 mm inner plaster 455.3
As per 15 mm plaster 256.9
As per 6 mm plaster 328.6
Deduction ( wall tiles area ) -126.5
37 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as wall putty area 914.2 Sq m 113.90 101.70 92,974
38 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as outer plaster area 245.2 Sq m 161.15 143.88 35,277
39 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work
40 10.18 Providing and fixing circular cast iron box for ceiling fan all complete
41 9.47 Providing and fixing nickel plated M.S pipe curtain rods with nickel plated brackets
42 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with flats, square or round bars etc. including priming cost with approved steel primer all complete.
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc. ( @ 24 kg Per sqm) 32.74 785.7 kg 183.50 163.84 128,729
43 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Face area 3 7.30 0.45 9.9
Face area 2 7.36 0.45 6.6
Face area 1 7.50 0.45 3.4
Face area 1 8.20 0.45 3.7
TOTAL excl. taxes 4,339,074
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - 3rd Floor ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
2 (a) 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door
Beam size 250 x 600
Roof Beam Size 250 x 450
Along Grid F (SB1) 1 3.05 0.25 0.32 0.24
Beam13 ( Lift & cut out) 4 1.95 0.25 0.32 0.62
Beam size 125 x 450
Total Length of 250 x 600 beam 142.90
Total Length of 250 x 450 beam 83.30
Total Length of 125 x 450 beam 3.00
2(b) 5.3 Providing RCC (1:1.5:3) in Roof slab, Landing excluding the cost of centring, shuttering and reinforcement
Slab Beam Bottom 1 23.65 0.60 0.10 1.42
Slab beam top 1 23.65 0.60 0.15 2.13
Balcony projection 3 2.28 0.93 0.15 0.95
Deductions for openings (stair) -1 3.33 2.55 0.13 -1.10
Behind Stair -1 5.15 2.55 0.13 -1.71
2© 5.3 Providing RCC (1:1.5:3) in Staircase excluding the cost of centring, shuttering and reinforcement
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 90.57
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for:
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Slab Beam Bottom 1 23.65 0.60 14.2
Slab beam top 1 23.65 0.60 14.2
Balcony projection 3 2.28 0.93 6.3
Deductions for openings (stair) -1 3.33 2.55 -8.5
Lift anf duct -2 1.95 1.98 -7.7
Behind Stair -1 5.15 2.55 -13.13
b 5.9.5 Lintel, Beam
c 5.9.19 Chajja
d 5.9.6 Column and Stiffener
Waist slab 2 3.00 1.20 7.2
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Outer wall 250mm thk.
Along Grid-A 1 6.38 0.25 2.40 3.8
Along grid B 1 2.13 0.25 2.40 1.3
Along grid E 1 2.45 0.25 2.40 1.5
Along grid H 1 8.65 0.25 2.40 5.2
Total length of 250 the. Outer wall 52.55
Inner wall 250 mm thk.
Lift and cut out 1 7.80 0.25 2.55 5.0
Total length of 250 the. Inner wall 22.05
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
Inner wall (125 mm thk.)
Along grid B 1 6.68 2.40 16.0
Between Grid A & B 1 10.65 2.55 27.2
Along grid C 1 13.95 2.40 33.5
Along grid E 1 3.10 2.40 7.4
Along grid G 1 5.90 2.55 15.0
Along grid 4 1 3.40 2.55 8.7
Along grid 6 1 7.18 2.55 18.3
along grid 8 1 3.85 2.55 9.8
Along Grid 10 1 3.40 2.55 8.7
Total length of 125 the.inner. wall 89.50
Outer wall 125 mm thk.
Along grid H 1 8.00 2.40 19.2
Along grid F 1 2.55 2.55 6.5
Along grid 10 1 5.80 2.40 13.9
Total length of 125 the.outer . wall 24.30
Deduction for openings
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:3) Ceiling plaster
Slab Beam Bottom 1 23.65 0.60 14.19
Slab beam top 1 23.65 0.60 14.19
Balcony projection 3 2.28 0.93 6.31
Deductions for openings (stair) -1 3.33 2.55 -8.48
Lift anf duct -2 1.95 1.98 -7.70
Behind Stair -1 5.15 2.55 -13.13
8 13.4.2 12 mm (1:6) cement Plaster
Length of 250 the outer wall ( inner face ) as per 250 the. Brick work 1 52.55 2.87 150.8
Length of 250 the. Inner wall ( both face ) as per 250 the. Brick work 2 22.05 2.87 126.6
Deduction for openings
Length of 125 the. Wall ( one side plaster ) as per 125 the. Brick work 1 113.80 2.87 326.6
Total 12 mm plaster 525.0 Sq m 263.55 235.31 123,541
9 13.5.2 15 mm Cement plaster of rough side of single or half brick wall of mix 1:6 ( 1 cement:6 coarse sand)
Length of 125 the. Wall ( one side) as per 125 the. Brick work 1 113.80 2.87 326.6
10 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 250 mm thk 1 52.55 3.00 157.7
Outer Wall 125mm thk 1 24.30 3.00 72.9
11 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 200.00 200.0 meter 57.75 51.56 10,313
12 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Stair Tread ) Flooring 18 1.20 0.25 5.4
( Stair Landing) 1 2.55 1.20 3.1
13 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Providing and laying 60x60 cm Vitrified floor tiles over 20 mm thick cement mortar (1:4) all complete
between bed room 2 1.50 1.75 5.25
14 11.37 Providing and laying Ceramic Glazed Floor tiles 300x300 in skirting of approved shade over 20 mm thick (1:4) cement mortar
15 11.23 Marble stone flooring with 18 mm thick marble stone as per sample of marble approved by engineer in charge, over 20 mm ( average) thick base of cement mortar1:4(1 cement:4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completewith:
11.23.2 Rajnagar Plain
16 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.1 Rajnagar Plain white marble
Kit Skirting 2 9.90 0.10 2.0
Kit Skirting 1 10.90 0.10 1.1
Lobby Skirting 1 9.63 0.10 1.0
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade
Lift wall 1 1.15 2.10 2.4
18 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Stair riser 20 1.20 0.15 3.6
landing 1 2.55 0.15 0.4
landing 2 1.20 0.15 0.4
19 11.46.2 Providing and laying Vitrified tiles in Skirting, Riser of steps over 12 mm cement mortar (1:3) all complete
Drawing & Din 2 20.25 0.10 4.1
20 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
21 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
22 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmiumplated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beadingand hinges will be paid for separately).
9.131.1 25 mm thick
23 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.50 Kg Per Meter )
24 9.21 Providing and fixing ISI marked flush door shutters confirming to IS:2202(PartI) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneer on both faces of shutters.
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
25 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required)extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size accordingto uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
26 9.147A.6 Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm)
27 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
28 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 52 52.0 No 187.75 167.63 8,717
29 2407 5.5mm Glass pane in door / window shutter
30 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
31 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
32 9.98 Providing and fixing aluminium pull bolt lock,ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS; 1868) transparent or dyed to rewuired colour and shade with necessary screws bolts, nut and washers etc. complete 13 13.0 each 85.95 76.74 998
33 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
34 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper 22 22.0 no 62.05 55.40 1,219
35 10.28 Providing & Fixing Stainless steel (grade 304) railing made of hollow tubes all complete
@ 5 Kg per metre ( stair railing) 2 3.76 7.5
Balcony railing 2 9.43 18.9
36 13.26 Providing and applying POP Putty of average thickness 2 mm of approved brand and manufacture
As per 12 mm inner plaster 525.0
As per 15 mm plaster 326.6
As per 6 mm plaster 350.7
Deduction ( wall tiles area ) -117.5
37 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as wall putty area 1,084.8 Sq m 113.90 101.70 110,318
38 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as outer plaster area 230.6 Sq m 161.15 143.88 33,172
39 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work
40 9.47 Providing and fixing nickel plated M.S pipe curtain rods with nickel plated brackets
41 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with flats, square or round bars etc. including priming cost with approved steel primer all complete.
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc. ( @ 24 kg Per sqm) 32.74 785.7 kg 183.50 163.84 128,729
42 10.18 Providing and fixing circular cast iron box for ceiling fan all complete
43 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Face area 3 7.30 0.45 9.9
Face area 2 7.36 0.45 6.6
Face area 1 7.50 0.45 3.4
Face area 1 8.20 0.45 3.7
TOTAL excl. taxes 4,478,532
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - 4th Floor ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
Stiffener at Parapet 4 0.25 0.25 1.20 0.3
2 (a) 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door
Beam size 250 x 600
Roof Beam Size 250 x 450
Along Grid F (SB1) 1 3.05 0.25 0.32 0.24
Beam12 ( Lift & cut out) 4 1.95 0.25 0.32 0.62
Beam size 125 x 600
R.C.C. band at paraper
Total Length of 250 x 600 beam 117.43
Total Length of 250 x 450 beam 66.55
Total Length of 125 x 450 beam 0.75
2(b) 5.3 Providing RCC (1:1.5:3) in Roof slab, Landing excluding the cost of centring, shuttering and reinforcement
Slab Beam Bottom 1 10.10 0.60 0.10 0.61
Slab beam top 1 23.65 0.60 0.15 2.13
Balcony projection 1 4.55 0.93 0.15 0.63
2(c ) 5.3 RCC Chajja
2(d) 5.3 Providing RCC (1:1.5:3) in Staircase excluding the cost of centring, shuttering and reinforcement
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 74.53
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for:
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Roof slab 1 5.30 1.93 10.2
Slab Beam Bottom 1 10.10 0.60 6.1
Slab beam top 1 23.65 0.60 14.2
Balcony projection 1 4.55 0.93 4.2
b 5.9.5 Lintel, Beam
Total 204.5 Sq m 552.05 492.90 100,775 TOTAL IS 208 To be rectified
c 5.9.19 Chajja
d 5.9.6 Column and Stiffener
Stiffener at Parapet 4 1.00 1.20 4.8
Total 128.2 Sq m 733.70 655.09 83,956 TOTAL QTY IS 133 To be rectified
Waist slab 2 3.00 1.20 7.2
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Outer wall 250mm thk.
Along Grid-A 1 7.18 0.25 2.40 4.3
Along grid B 1 4.95 0.25 2.40 3.0
Along grid H 1 4.33 0.25 2.40 2.6
Total length of 250 the. Outer wall 55.95
Inner wall 250 mm thk.
Along grid C 1 7.85 0.25 2.55 5.0
Lift and cut out 1 7.80 0.25 2.55 5.0
Total length of 250 th. Inner wall 25.13
Parapet wall 250 th. 1 27.44 0.25 1.13 7.7
Total length of Parapet wall 27.44
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
Inner wall (125 mm thk.)
Along grid B 1 7.43 2.40 17.8
Between Grid A & B 1 4.68 2.55 11.9
Along grid G 1 5.03 2.55 12.8
Cupboard 1 3.13 2.87 9.0
Between grid 10-11 1 4.48 2.55 11.4
Along grid 9 1 1.60 2.55 4.1
Near Along grid 6 1 4.22 2.55 10.8
Along Grid 10 1 6.43 2.55 16.4
Total length of 125 the.inner. wall 39.98
Outer wall 125 mm thk.
Along grid H 1 4.00 2.40 9.6
Near Along grid H 1 3.30 2.40 7.9
Along grid F 1 2.55 2.55 6.5
Between grid A & B 1 4.72 2.55 12.0
Total length of 125 the.outer . wall 17.58
Deduction for openings
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:3) Ceiling plaster
Slab Beam Bottom 1 10.10 0.60 6.06
Slab beam top 1 23.65 0.60
Balcony projection 1 4.55 0.93 4.21
8 13.4.2 12 mm (1:6) cement Plaster
Length of 250 the outer wall ( inner face ) as per 250 the. Brick work 1 55.95 2.87 160.6
Length of 250 the. Inner wall ( both face ) as per 250 the. Brick work 2 25.13 2.87 144.2
Deduction for openings
Length of 125 th. Wall ( one side plaster ) as per 125 the. Brick work 1 57.56 2.87 165.2
Total 12 mm plaster 416.9 Sq m 263.55 235.31 98,095
9 13.5.2 15 mm Cement plaster of rough side of single or half brick wall of mix 1:6 ( 1 cement:6 coarse sand)
Length of 125 the. Wall ( one side) as per 125 the. Brick work 1 39.98 2.87 114.7
10 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 250 mm thk 1 55.95 3.00 167.9
Outer Wall 125mm thk 1 17.58 3.00 52.7
Parapet wall 1 27.44 2.80 76.8
11 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 200.00 200.0 meter 57.75 51.56 10,313
12 11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Stair Tread ) Flooring 18 1.20 0.25 5.4
( Stair Landing) 1 2.55 1.20 3.1
13 11.41 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
11.41.2 Providing and laying 60x60 cm Vitrified floor tiles over 20 mm thick cement mortar (1:4) all complete
Family Lounge/Din. 1 8.15 3.18 25.88
between bed room 1 1.50 1.25 1.88
cup board area 1 9.10 0.60 5.46
14 11.37 Providing and laying Ceramic Glazed Floor tiles 300x300 in skirting of approved shade over 20 mm thick (1:4) cement mortar
15 11.38 Providing and laying ceramic glazed floor tiles of size 300x300 mm( thickness to be specified by the manufacturer )of 1st quality conforming to IS:15622 of approved make in colours, shades, except , ivory, grey, fume red brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement:4 Coarse sand ) jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc. complete.
16 11.23 Marble stone flooring with 18 mm thick marble stone as per sample of marble approved by engineer in charge, over 20 mm ( average) thick base of cement mortar1:4(1 cement:4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing completewith:
11.23.2 Rajnagar Plain
Kitchen 1 2.98 3.18 9.4
17 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.1 Rajnagar Plain white marble
Kit Skirting 1 11.40 0.10 1.1
Lobby Skirting 1 8.28 0.10 0.8
18 8.9 Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar1:3 ( 1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/ sqm including pointing in white cement.
8.9.1 8 mm thick
8.9.1.2 Granite of any colour and shade
Lift wall 1 1.15 2.10 2.4
19 11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Stair riser 20 1.20 0.15 3.6
landing 1 2.55 0.15 0.4
landing 2 1.20 0.15 0.4
20 11.46.2 Providing and laying Vitrified tiles in Skirting, Riser of steps over 12 mm cement mortar (1:3) all complete
Lounge/ Din 1 17.19 0.10 1.7
Ent. Lobby 1 5.03 0.10 0.5
Between bed room 1 1.00 0.10 0.1
21 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
22 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
23 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmiumplated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beadingand hinges will be paid for separately).
9.131.1 25 mm thick
24 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.50 Kg Per Meter )
25 9.21 Providing and fixing ISI marked flush door shutters confirming to IS:2202(PartI) non decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneer on both faces of shutters.
9.21.1 35 mm thick including ISI marked stainless steel butt hinges with necessary screws.
26 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required)extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size accordingto uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.)
27 9.147A.6 Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqm upto 5.00 sqm)
28 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
29 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 38 38.0 No 187.75 167.63 6,370
30 2407 5.5mm Glass pane in door / window shutter
31 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
32 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
33 9.98 Providing and fixing aluminium pull bolt lock,ISI marked, anodised ( anodic coating not less than grade AC 10 as per IS; 1868) transparent or dyed to rewuired colour and shade with necessary screws bolts, nut and washers etc. complete 8 8.0 each 85.95 76.74 614
34 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
35 9.101 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper 8 8.0 no 62.05 55.40 443
36 10.28 Providing & Fixing Stainless steel (grade 304) railing made of hollow tubes all complete
@ 5 Kg per metre ( stair railing) 2 3.76 7.5
Balcony railing 1 6.25 6.3
37 13.26 Providing and applying POP Putty of average thickness 2 mm of approved brand and manufacture
As per 12 mm inner plaster 416.9
As per 15 mm plaster 114.7
As per 6 mm plaster 116.9
Deduction ( wall tiles area ) -93.5
38 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as wall putty area 555.0 Sq m 113.90 101.70 56,445
39 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as outer plaster area 297.4 Sq m 161.15 143.88 42,794
40 13.61 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.61.1 Two or more coats on new work
41 10.18 Providing and fixing circular cast iron box for ceiling fan all complete
42 9.47 Providing and fixing nickel plated M.S pipe curtain rods with nickel plated brackets
43 9.48 Providing and fixing M.S. grills of required pattern in frames of windows etc. with flats, square or round bars etc. including priming cost with approved steel primer all complete.
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc. ( @ 24 kg Per sqm) 24.05 577.3 kg 183.50 163.84 94,578
44 22.5 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Face area 1 7.30 0.45 3.3
Face area 2 7.36 0.45 6.6
Face area 1 7.50 0.45 3.4
Face area 1 8.20 0.45 3.7
45 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 2.0 each 244.05 217.90 436
TOTAL excl. taxes 3,710,449
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - Parapet and Mumty ( DSR 2019 )
SN DSR-2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 5.2.2 providing RCC (1:1.5:3) with graded stone chips of 20 mm nominal size in Column, Stiffener, Plinth band excluding the cost of centring, shuttering and reinforcement all complete
Stiffener ( parapet wall ) 15 0.25 0.25 1.20 1.1
2 5.3 Providing RCC (1:1.5:3) in Band at Lintel, Beam at Lintel, Roof Beam excluding the cost of centring, shuttering and reinforcement
Lintel over Door & Window
Band at parapet 1 70.10 0.38 0.08 2.0
3 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D of more
Total RCC 26.12
4 5.9 Centring and shuttering including strutting, propping etc. and Removal of form for:
a 5.9.3 Suspended floors, roofs, landings, balconies and access platform
Roof slab 1 3.05 3.83 11.7
b 5.9.5 Lintel, Beam
c 5.9.19 Chajja
d 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Band at parapet 1 70.10 0.23 15.77
e 5.9.6 Column and Stiffener
Water tank 1 27.50 0.70 19.3
Stiffener ( parapet wall ) 15 0.50 1.20 9.0
5 6.4 Brick work with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to V level in all shapes and size in
6.4.2 F.P.S Brick work with Cement Mortar (1:6) in superstructure
Outer wall 250mm thk.
Machine room 1 8.75 0.25 3.25 7.1
Total length of 250 outer wall 21.63
250 the. Inner wall
Total Length of 250 the. Wall 7.05
Parapat wall 250mm thk
Total length of parapet wall 70.10
Deduction for openings
6 6.13 Half Brick Masonry with common burnt clay F.P.S (Non modular) brick of class designation 7.5 in superstructure above plinth level up to floor V level
6.13.2 F.P.S Brick work with Cement Mortar (1:4) in superstructure
outer wall (125 mm thk.)
Stair wall 1 2.55 2.10 5.4
Deduction for openings
Length of 125 the. Outer wall 2.55
7 13.16 6 MM CEMENT PLASTER
13.16.1 6 mm (1:4) Ceiling plaster
13.4.2 12 mm (1:6) Cement Plaster Over Inner plaster
8 250 outer wall one face 1 21.63 3.40 73.5
250 the. Inner wall both face 2 7.05 3.40
125 wall one face 1 2.55 2.10 5.4
Deduction for openings
9 13.6.2 20 mm Cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
Outer wall 250 mm thk 1 21.63 3.70 80.03
125 th. Outer wall 1 2.55 3.70 9.44
Parapet wall Plaster Both Side 2 70.10 1.20 168.24
Parapet top 1 70.10 0.40 28.04
10 13.73 Forming groove of uniform size in plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the ecges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
13.73.2 20 mm wide and 15 mm deep grove 20.00 200.0 meter 57.75 51.56 10,313
11.26.1 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
Machine room 1 1.95 4.85 7.8
Top Landing 1 2.55 2.08 5.6
11.27 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Machine room 12.60 0.10 1.3
Landing 5.70 0.10 0.6
11 8.31 Providing and fixing 1st quality Ceramic glazed wall tiles all complete
Water tank 1 3.30 1.50 5.0
12 9.1 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or
dash fastener shall be paid for separately).
9.1.2 Providing Sal wood work in Frames of Door, Windows etc. and fixed in position all complete
13 9.131 Providing and fixing factory made shutters of Pre-laminated particle board flat pressed three layer or graded wood particle board with one side decorative finish and other side balancing lamination conforming to IS: 12823 Grade l Type ll, of approved design, and edges sealed with water resistant paint and lipped with aluminium 'U' type edge beading all- round the shutter, including fixing with angle cleat, grip strip, cadmium plated steel screws, including fixing of aluminium hinges 100x63x4 mm etc. complete as per architectural drawing and direction of Engineer-in-Charge (Cost of 'U' beading and hinges will be paid for separately).
9.131.1 25 mm thick
14 9.132 Providing and fixing aluminum U beading of required size to Pre-laminated/flush door shutter, including fixing etc. complete as per direction of Engineer-in-charge (@ 0.5 Kg Per Meter )
15 9.147A.3 Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm).
16 9.149 Providing and fixing casement handle made of zinc alloyed (white powder coated) for uPVC casement window with necessary screws etc. complete 2 2.0 No 187.75 167.63 335
17 2407 Float glass panes of nominal thickness 5.5 mm ( weight not less than 12.50 kg/sqm)
18 9.96 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
19 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
20 9.100 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete.
21 13.26 Providing and applying White cement based Putty of average thickness 2 mm of approved brand and manufacture
Quantity same as plaster area ( 6mm and 12 mm inner) 137.3 Sq m 196.70 175.63 24,122
22 13.83.2 Prium Acrylic emulsion paint of approved brand and manufacture
Quantity same as putty area 137.3 Sq m 113.90 101.70 13,968
23 13.47 Finishing walls with premium Acrylic smooth exterior paint with silicone additives of required shade
13.47.1 New work (Two or more coats applied @ 1.43kg/10sqm) over and including base coat of water proffing cement paint Snowcem Plus or equivalent applied @ 2.20 kg/10 sqm
Quantity same as outer plaster area 285.7 Sq m 161.15 143.88 41,114
24 13.62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved band and manufacure
25 22.7 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces / sunken slabs etc consisting of following operations.
(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS:2645 and approved by engineer -in-charge over the RCC slab including adjoining walls up to 300 mm height including cleaning the surface before treatment.
(b) Laying brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1cement: 5 coarse sand) admixed with proprietary water profing compound conforming to IS: 2645 over 20mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand) admixed with prorietary water proofing compound conforming to IS: 2645 and appeoved by engineer-in-charge to requiredslope and treating similary the adjoining walls upto 300mm height including rounding of junctions to walls and slabs.
(c )After twodays of proper curing applying a second coat of cement slurry using 2.75 kg / sqm of cement admixed with proprietary water proofing compound conforming to IS: 2645.and approved by engineer-in charge.
(d)Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 (1 cement:4 coarse sand) admixed with proprietary water proofingcompound conforming to IS: 2645 and laying approved by engineer - in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowelwith neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep.
(e)The whole terraceso finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Enigneer-in-charge.
22.7.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm
Terrace area 1 5.10 12.35 63.0
26 10.5 Providing and fixing 1 mm thick M.S. sheet door with frame of 40 x 40x 6 mm angle iron and 3 mm MS gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer
10.5.2 Using flats 30 x 6 mm for diagonal braces and central cross piece. 1 1.00 2.00 2.0 Sq m 4,278.15 3,819.78 7,640
27 10.25 Steel work welded in built-up sections/framed work,including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required
10.25.2 In gratings, frames,guard bar, ladder, railing, brackets, gates and similar works.
28 12.22 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 5.0 each 244.05 217.90 1,090
TOTAL excl. taxes 1,335,810
Proposed Construction of Residential Dwelling unit at 400 KV GIS Chandwa
Calculation of Quantity of Materials - Upto Plinth Level
SN DSR 2018 Particulars No. Length Width Height Quantity Unit Rate Rate*(100/112) Amount
1 2.8 Earth work in excavation by mechanical means ( Hydraulic excavator)/ manual means in foundation trenches or drains (not exceding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, with all lead & lifts.
2.8.1 All Kinds of soil
2 2.25 Filling available excavated earth(excluding rock) in trenches , plinth, sides of foundations etc. in layers not exceeding 20cm in depth: consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Total Excavation = 552.96 , Refilling @ 60 % of total excavation = 552.96 x 0.60 =331.78 or say = 335 m3
3 2.27 Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
Under plinth ( Total site should be raised yp to 0.30 m ) Total site area = 835 m2 and av. Depth of filling = 0.30 m 1 835.00 0.30 250.50
Deduction ( available excavated earth form foundation = total excavation - filling available earth = 552.96 - 331.78= 221.18 or say = 221 cum) -221.00
Brick work up to plinth 0.83
4 DAR 11.2 Providing brick of class designation 75 in one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per specification and direction of Engineer-in-charge.
5 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-all work upto plinth level.
4.1.3 1:2:4 ( 1 Cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size)
6 5.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-all work upto plinth level.
5.1.2 1:1:5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Column below FGL
Along grid A (TB2) 1 8.57 0.25 0.50 1.07
Along Grid A (TB1) 1 2.58 0.25 0.40 0.26
Along Grid B ( TB3+TB5) 1 7.83 0.25 0.40 0.78
Along Grid D(TB10) 1 3.05 0.25 0.40 0.31
Along Grid F(TB13) 1 2.55 0.25 0.40 0.26
Total length of 250 x 500 tie beam 41.95
Total length of 250 x 400 tie beam 155.90
Total Length of 125 x 400 tie beam 0.45
R.C.C. band at plinth
7 5.22 Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Total RCC 151.75
Steel in kg/ cum 120 18209.96
5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more 18209.96 Kg 83.50 74.55 1,357,617
8 5.9 Centring and shuttering including strutting, propping etc. and removal of form
Pedestal 2 2.60 0.15 0.78
Pedestal 9 2.60 0.15 3.51
Pedestal 4 2.60 0.15 1.56
Pedestal 11 2.60 0.15 4.29
Pedestal 4 2.90 0.15 1.74
9 6.1 Brick work with common burnt clay F.P.S. ( Non modular) bricks of class designation 7.5 in foundation and plinth
6.1.2 Cement mortar 1:6( 1 cement:6 coarse sans) 44.28 0.25 0.08 0.83
TOTAL excl. taxes 3,748,306
PROJECT:- PROPOSED RESIDENTIAL DWELLING UNIT
AT 400 KV GIS, CHANDWA
CLINT-POWER GRID CORPORATION OF INDIA LIMITED
RATE REFERANCE- D.S.R. (2019)/MR
ESTIMATE OF COST (P. H. E. WORKS )
S.N. Ref. Description Unit Quantity Rate Rate*(100/112) Amount
1 DSR 18.7 Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,including fixing the pipe with clamp at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.
(A) DSR 18.7.2 20 mm dia. Nominal outer dia pipes Metre 60.00 306.95 274.06 16443.75
(B) DSR 18.7.3 25 mm dia. Nominal outer dia pipes Metre 35.00 369.20 329.64 11537.50
(C) DSR 18.7.4 32 mm dia. Nominal outer dia pipes Metre 43.00 480.55 429.06 18449.69
(D) DSR 18.7.5 40 mm dia. Nominal outer dia pipes Metre 69.00 648.60 579.11 39958.39
(E) DSR 18.7.6 50 mm dia. Nominal outer dia pipes Metre 88.00 903.50 806.70 70989.29
2 DSR 18.8 Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings,i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.
Concealed work, including cutting chases and making good the walls etc.
(A) DSR 18.8.1 15 mm dia. Nominal outer dia pipes Metre 213.00 409.65 365.76 77906.65
(B) DSR 18.8.2 20 mm dia. Nominal outer dia pipes Metre 115.00 478.15 426.92 49095.76
3 DSR 18.9 Providing and fixing Chlorinated polyvinyl Chloride(CPVC) pipes,having thermal stability for hot & cold water supply,including all CPVC plain & brass threaded fittings, This includes jointing of pipes & fittings with one step CPVC solvent cement trenching,refilling and testing of joints complete as per direction of engineer in charge.
(A) DSR 18.9.4 32 mm dia. Nominal outer dia pipes Metre 103.00 413.70 369.38 38045.63
(B) DSR 18.9.5 40 mm dia. Nominal outer dia pipes Metre 15.00 536.75 479.24 7188.62
4 DSR 18.13 Making connection of G.I. distribution branch with G.I. Main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.
(A) DSR 18.13.1 25 to 40 mm Nominal bore each 1.00 673.45 601.29 601.29
5 SOR 18.17 Providing and fixing brass gate valve with C.I. wheel of approved quality. 0.00
(A) DSR 18.17.1A 20 mm Nominal bore Each. 55.00 460.20 410.89 22599.11
(B) DSR 18.17.1 25 mm Nominal bore Each. 1.00 497.15 443.88 443.88
(C) DSR 18.17.2 32 mm Nominal bore Each. 7.00 581.25 518.97 3632.81
(C) DSR 18.17.3 40 mm Nominal bore Each. 2.00 678.40 605.71 1211.43
(E) DSR 18.17.4 50 mm Nominal bore Each. 3.00 869.20 776.07 2328.21
6 DSR 18.19 Providing and fixing metal non-return valve of approved quality.
DSR 18.19.2 32 mm nominal bore
DSR 18.19.3 40 mm nominal bore
DSR 18.19.3.1 Horizontal Each. 1.00 792.40 707.50 707.50
7 DSR 18.46 Providing and fixing G.I. union in G.I.pipe including cutting and threading the pipe and making long screws etc.complete
(A) DSR 18.46.2 20 mm dia. Nominal bore each 55.00 261.15 233.17 12824.33
(B) DSR 18.46.3 25mm dia. Nominal bore each 13.00 340.10 303.66 3947.59
(C) DSR 18.46.4 32mm dia. Nominal bore each 15.00 384.25 343.08 5146.21
(D) DSR 18.46.5 40mm dia. Nominal bore each 11.00 452.50 404.02 4444.20
(E) DSR 18.46.6 50mm dia. Nominal bore each 13.00 598.10 534.02 6942.23
C.P. BRASS FITTINGS
8 DSR 18.49 Providing and fixing C.P brass bib cock of approved quality confirming to IS:8931
DSR 18.49.1 15mm nominal bore Each 45.00 418.95 374.06 16832.81
9 DSR 18.50 Providing and fixing C.P. brass long bib cock of approved quality conforming to IS standards and weighing not less than810 gms.
DSR 18.50.1 15 mm Nominal bore Each 23.00 618.80 552.50 12707.50
10 DSR 18.52 Providing and fixing C.P. brass stop cock(concealed) of standard design and of approved make confirming to8931
DSR 18.52.1 15 mm Nominal bore Each 67.00 606.25 541.29 36266.74
11 DSR 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser pointsof approved quality confirming to8931
DSR 18.53.1 15 mm Nominal bore Each 96.00 532.00 475.00 45600.00
12 DSR 18.22 Providing and fixing CP brass shower rose with 15 or 20 mm inlet
13 DSR 18.58 Providing and fixing P.T.M.T. grating of approved quality & colour
DSR 18.58.1 circular type
B SANITARY INSTALLATION
1 DSR 17.1 Providing and fixing water closet squatting pan(indian type WC pan)with 100mm sand cast iron P or S trap, 10 litre low fixture complete , including ctting and making good the walls and level white PVC flushing cistern,including flush pipe with manuall controlled device(handle leer) cofirming to IS 7231, with all fittings and floors wherever required
DSR 17.1.1 white vitreous china Orissa pattern WC pan of size 580X440mm with integral type foot rests Each 12.00 5421.50 4840.63 58087.50
2 DSR 17.78 Providing and fixing White vitreous china extended wall mounting water closet of size 780 x 370 x 690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fittings of flushing capacity 3 liters/6 liters(adjustable to 4 lit./8 litres),including seat cover,and cistern fittings,nuts,bolts,and gasket etc. complete Each 13.00 13852.45 12368.26 160787.37
3 DSR 17.4 Providing and fixing .white vitreous china flat back or wall corner type lipped front urinal basin of size 450 x 260 x 350mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreaders with brass unions and GI clamps complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required.
DSR 17.4.1 One urinal basin with 5 litres white P.V.C. automatic flushing cistern. Each 1.00 4982.25 4448.44 4448.44
4 DSR 17.7 Provding and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, , 32 mm C.P. brass waste of standard pattern, including paintings of fittings and brackets, cutting and making good the .wall wherever required.
DSR 17.7.4 White vitreous china flat back wash basin size 550X400mm with a single15mm CP brass pillar tap Each 24.00 2510.45 2241.47 53795.36
5 DSR 17.10 Provding and fixing Stainless Steel A ISI 304 (18/8) Kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40mm inculding painting of fitting and brackets, cutting and making good the walls wherever required.
DSR 17.10.1 Kitchen sink with drain board.
6 DSR 17.28 Provding and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete
DSR 17.28.2 Flexiable pipe
7 DSR 17.31 Provding and fixing 600X450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with CP brass screws & washers complete. Each 24.00 1283.05 1145.58 27493.93
8 DSR 17.33 Provding and fixing 600X120X5 mm glass shelf with edges rounded off supported on anodised aluminium angle frame with CP brass brackets and guard rail complete fixed with 40 mm long screws ,rawl plug etc, complete. Each 24.00 841.80 751.61 18038.57
9 DSR 17.34 Provding and fixing toilet paper holder
10 DSR 17.70 Provding and fixing PTMT bottle traps for wash basin & sink
DSR 17.70.2 Bottle trap 38 mm single piece moulded with height of 270mm , effective length of tail pipe 260mm from the centre of waste coupling 77mm breadth with 25mm minimum water seal ,weighing not less than 263 gms. Each 24.00 348.60 311.25 7470.00
11 DSR 17.71 Provding and fixing PTMT liquid soap container 109 mm wide,125mm high and 112mm distance from wall of standard shape with bracket of same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. Each 24.00 158.55 141.56 3397.50
12 DSR 17.73 Provding and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
DSR 17.73.2 600 mm long towel rail with total length of 645mm width78mm and effective height of 88mm,weighing not less than 190 gms. Each 24.00 595.50 531.70 12760.71
RAIN WATER PIPE & BALCONY DRAINAGE
13 DSR 12.41 Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS:13592 Type-A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion
14 DSR 12.42 Providing and fixing on wall face unplasticised -PVC moulded fittings/ accessories for unplasticised Rigid PVC rainwater pipes conforming to IS: 13592 Type-A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
DSR 12.42.1 Coupler
DSR 12.42.4 single tee without door
DSR 12.42.5 Bend 87.50
DSR 12.42.6 Shoe (Plain)
15 DSR 12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S screws of required length including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
16 DSR 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 6.00 47.25 42.19 253.13
1 DSR 2.10 Excavating trenches of required width for pipes, cables etc including excavation for sockets and dressing of sides, ramming of bottoms depth upto 1.5m ,including getting out the excavated soil , and then returning the soil as required,in the layers not exceeding 20 cm in depth including consolidating each deposited layers by ramming watering and desposing of surplus excavated soil as dirceted within a lead of 50m
(A) DSR 2.10.1.2 pipes cables etc exceeding 80mm dia but not exceeding 300 mm dia Metr. 377.00 364.20 325.18 122592.32
2 DSR 19.6 Providing and laying non -pressure NP2 class(light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc. complete
3 DSR 19.7 Constructing brick masonary manhole in cement mortar 1:4 (1 cement, 4 coarse sand.) with R.C.C. top slab with1:1.5:3 mix(1 cement, 1.5 coarse sand, 3 graded stone aggregate 20 mm nominal size) foundation concrete 1:4:8 mix (1cement, 4 coarse sand, 8 graded stone aggregate 40 mm nominal size.) inside plastering 12 mm thick with cement mortar 1:3 (1 cement, 3 coarse sand.) finished with floating coat of neat cement and making channels in cement concrete 1:2:4. finished with floating coat of neat cement complete as per standard design.
(a) DSR 19.7.1 Inside size 90x80cm and 45 cm deep including C.I. cover with frame ( light duty) 455x610 mm internal diamension tatal weight of cover and fram to be not less than 38 kg (weight of cover23 kg and weight of frame 15 kg )
DSR 19.7.1.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 28.00 10905.05 9736.65 272626.25
(b) SOR 19.7.2 Inside size 120x90cm and 90 cm deep including C.I. cover with frame (medium duty) 500mm internal diameter total weight of cover and fram to be not less than 116 kg (weight of cover 58kg and weight of frame 58 kg )
SOR 19.7.2.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 6.00 22939.69 20481.87 122891.20
4 DSR 19.28 Constructing brick masonry road gully chamber 45x45x77.5cms with bricks in cement mortar 1:4(1cement: 4 c coarse sand)with pre-cast R.C.C. vertical grating complete as per standard design:
DSR 19.28.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 26.00 5794.85 5173.97 134523.30
5 DSR 19.32 Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with brick and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
DSR 19.32.1 With cmmon burnt clay F.P.S. (non modular)bricks with class designation 7.5 Each 2.00 25278.75 22570.31 45140.63
Liquid Dimension 4500X1500X1500 cu-m
1 DSR 2.8 Earthwork in excavation by mechanical means (Hydraulic excavtor)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sq m on plan ) including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated as directed within a lead of 50m
DSR 2.8.1 All kind of soil Cum 48.88 252.30 225.27 11011.09
2 DSR 2.27 Supplying and filling in plinth with sand and under floors including watering,ramming consolidating and dressing complete Cum 2.03 1953.05 1743.79 3539.90
3 DSR 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level
DSR 4.1.3 1:2:4(1cement:2 corse sand:4 graded stone aggregate 20mm nominal size Cum 2.03 6788.60 6061.25 12304.34
4 DSR 6.1 Brick work with common burnt clay FPS bricks of class designation 7.5 in foundations and plinth in
DSR 6.1.2 Cement morter 1:6(1 cement : 6 corse sand) Cum 11.47 6157.45 5497.72 63058.89
5 DSR 13.7 12 mm cement plaster finished with a floting coat of neat cement of mix
6 DAR 11.2 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, Sqm. 14.19 408.12 364.39 5170.73
7 DSR 5.3. Reinforced cement concrete work in beams,suspended floors roofs,having slope upto 15, landing,balconies, shelves,chajjas,lintal,bends,plain window sills stair case,and spiral staircases up to floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3 Cum 3.02 9763.80 8717.68 26327.39
8 DSR 5.9 Centring and shuttering including strutting propping etc. and removal of form for
DSR 5.9.3 Suspended floors ,roofs,landings,balconies and access platform Sqm. 10.72 693.05 618.79 6633.48
DSR 5.9.5 Lintels,beams, plinth beams, griders, bressumers and cantilivers Sqm. 0.38 552.05 492.90 187.30
DSR 5.9.6 Columns,pillars,piers,abutments,posts and struts Sqm. 6.00 733.70 655.09 3930.54
9 DSR 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
DSR 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 190.00 83.50 74.55 14165.18
10 DSR 19.18 Supplying and fixing C.I cover without frame for manholes:
DSR 19.18.2 500 mm diameter C.I cover (medium duty) the weiht of he cover to be not less than 58 kg. Each 2.00 3202.90 2859.73 5719.46
11 DSR 19.15 Providing M.S foot rests including fixing in septic tank with 20 x 20 x 10 cm cement concrete blocks 1:3:6 ( 1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size) as per standard design:
DSR 19.15.1 With 20 x 20 mm square bar Each 18.00 422.20 376.96 6785.36
150 DIAX100DIAX120 METRE DEPTH TUBEWELL
1 DSR 23.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
DSR 23.1.1 All types of soil
2 DSR 23.2 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
DSR 23.2.1 All types of soil 0.00
3 DSR 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
DSR 23.3.1 100 mm nominal size dia Mtrs. 45 600.35 536.03 24121.21
DSR 23.3.2 150 mm nominal size dia Mtrs. 30 690.75 616.74 18502.23
4 DSR 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
DSR 23.4.1 100 mm nominal size dia Metre 30 651.45 581.65 17449.55
5 DSR 23.8 Gravels packing in tubewell construction in accordance with IS 4097 including providing graval fine/medium/coarse,in required grading & sizes as per actual requirement,all complete as per direction of Engineer-in charge. cu_m 7.08 1497.70 1337.23 9467.60
6 DSR 23.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hrs 48 857.60 765.71 36754.29
7 DSR 23.13 Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of borewell housing/ casing pipe ,removable as per requirement,all complete for borewell of,
8 DSR 23.14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete 0.00
9 DSR 23.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
F. RAIN WATER HARVESTING
FILTER PIT & RECHARGE WELL(2 NOS.)
1 DSR 2.8 Earthwork in excavation by mechanical means (Hydraulic excavtor)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sq m on plan ) including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated as directed within a lead of 50m
DSR 2.8.1 All kind of soil Cum 111.50 252.30 225.27 25117.37
2 DSR 2.27 Supplying and filling in plinth with sand and under floors including watering,ramming consolidating and dressing complete Cum 1.78 1953.05 1743.79 3103.95
3 11.2 DAR Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l, Sqm 14.30 408.12 364.39 5210.82
4 DSR 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level
DSR 4.1.3 1:2:4(1cement:2 corse sand:4 graded stone aggregate 20mm nominal size Cum 1.90 6788.60 6061.25 11516.38
5 DSR 6.1 Brick work with common burnt clay FPS bricks of class designation 7.5 in foundations and plinth in
DSR 6.1.2 Cement morter 1:6(1 cement : 6 corse sand) Cum 17.88 6157.45 5497.72 98299.29
6 DSR 13.7 12 mm cement plaster finished with a floting coat of neat cement of mix
7 DSR 5.3. Reinforced cement concrete work in beams,suspended floors roofs,having slope upto 15, landing,balconies, shelves,chajjas,lintal,bends,plain window sills stair case,and spiral staircases up to floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:1.5:3 Cum 2.32 9763.80 8717.68 20225.01
8 DSR 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
DSR 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 56.00 83.50 74.55 4175.00
9 DSR 19.18 Supplying and fixing C.I cover without frame for manholes:
DSR 19.18.2 500 mm diameter C.I cover (medium duty) the weiht of he cover to be not less than 58 kg. Each 2.00 3202.90 2859.73 5719.46
10 DSR 23.1 Boring/drilling bore well of required dia for casing/strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
DSR 23.1.1 All types of soil
11 DSR 23.3 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.
DSR 23.3.1 100 mm nominal size dia metre 74.00 600.35 536.03 39665.98
12 DSR 23.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
DSR 23.4.1 100 mm nominal size dia metre 6.00 651.45 581.65 3489.91
13 DSR 23.5 Supplying , filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in Recharge Pit,in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 6.36 1326.55 1184.42 7532.91
14 DSR 23.6 Supplying , filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the Recharge Pit,over the existing layer boulders in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 6.00 1326.55 1184.42 7106.52
15 DSR 23.7 Supplying , filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm, in the Recharge Pit, in the required thickness over gravel layer ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 6.00 1326.55 1184.42 7106.52
16 DSR 23.13 Providing & fixing suitable size threaded mild steel cap or spot welded plate to top of borewell housing/casing pipe,removable as per requirement all complete for borewell of
17 SOR 23.14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete
18 DSR 23.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
UNDER GROUND WATER TANK
ANALYSIS Constructing Under Ground Water Tank of capacity 2.5 X 1.5X 1.5 m3 Liquid dimension all complete as per direction of engineer in charge (detail attchhed) each 2.00 151238.93 135034.76 270069.52
G NON SCHEDULED ITEMS(MARKET RATE)
MR Establishment of 2.0 HP of submersible pump set (detail attchhed) each 1 35856.00 32014.29 32014.29
MR Establishment of 1.0 HP of submersible pump set (detail attchhed) each 2 28468.00 25417.86 50835.71
ANALYSIS Provding and fixing soil,waste and vent pipes
ANALYSIS 1(a) 110 mm dia metre 427.00 464.00 464.00 198128.00
P.V.C. FITTINGS
ANALYSIS 110 mm dia each 66.00 358.00 358.00 23628.00
ANALYSIS 110 mm dia each 7.00 277.00 277.00 1939.00
ANALYSIS 110 mm dia each 34.00 182.00 182.00 6188.00
(iv) VENT COWEL
ANALYSIS 110 mm dia each 23.00 64.00 64.00 1472.00
ANALYSIS 110 mm dia each 284.00 52.00 52.00 14768.00
(vi) FLOOR TRAP
ANALYSIS 110X110 mm dia each 38.00 428.00 428.00 16264.00
TOTAL excl. taxes 3176239.45
PROJECT : RESIDENTIAL DWELLING UNIT AT 400 kV GIS CHANDWA , POWER GRID CORPORATION LTD.
NAME OF WORK : BOQ & ESTIMATE FOR ELECTRICAL & TELEPHONE WIRING
Sl No Item of work Unit Qty Rate ₹ Rate*(100/112) ₹ Amount ₹ Remarks
WIRING DSR 2018
1 Wiring for Light plug & circuit wiring with 2x2.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit along with 1 No.2.5 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required Meter 1550 167.00 149.11 231116.07 1.14.2
2 Wiring for power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 No.4 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required Meter 1692 200.00 178.57 302142.86 1.12
3 Wiring for submain with 2x10 sq.mm +1X6 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit etc. as required.(Main to DB) Meter 320 328.00 292.86 93714.29 1.14.5
4 Wiring for submain with 4x6 sq.mm +2X6 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit etc. as required.(Main to Common centre DB & Lift Room) Meter 100 394.00 351.79 35178.57 1.14.9
5 Wiring for submain with 4x10sq.mm +2X6 sq mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit etc. as required.(Main to D type ) Meter 45 543.00 484.82 21816.96 1.14.10
6 Supplying and fixing metal box of following size (nominal size) in surface/ recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required. 0.00 0.00
7 Supplying & fixing of following size medium class PVC conduit along with accessories in surface/ recess including cutting of wall and making good the same in case of recessed conduit as required. 0.00 0.00
8 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches/ socket/TV / Telephone outlet in surface/ recess etc. as required. 0.00 0.00
9 Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc as required. (Group B) Point 371 783.00 699.11 259368.75 1.10.2
10 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps moduler socket outlet & 6A modular type switch connection etc. as required. Point 130 401.00 358.04 46544.64 1.31
11 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/ 16 amps moduler socket outlet & 15/16A modular type switch connection etc. as required. Point 68 495.00 441.96 30053.57 1.32
12 Supplying and fixing 20 amps 240 volt, SPN industrial type, socket outlet, with 2 pole and earth metal enclosed plug top along ,with 20 amp 'C' series, SP, MCB in sheet steel enclosure on surface or in recess,with chained metal cover for socket out let and complete with connections testing and commissioning etc. as required. Each 26 1232.00 1100.00 28600.00 2.18
13 Supplying and fixing 30 amps 415 volt, TPN industrial type, socket outlet, with 4 pole and earth metal enclosed plug top along ,with 30 amp 'C' series, TP, MCB in sheet steel enclosure on surface or in recess,with chained metal cover for socket out let and complete with connections testing and commissioning etc. as required. ( Lift Room) Each 1 3048.00 2721.43 2721.43 2.20
14 Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated copper conductor telephone cable through existing PVC concuit/ raceway including connection, testing etc. as required. Meter 240 20.00 17.86 4285.71 1.18.2
15 Supplying and fixing moduler type 2 pin telephone socket on the existing box including making connection etc. as required. Each 12 119.00 106.25 1275.00 1.24.6
16 Supplying Installing Testing and commissioning of 20 Pair distribution tag box all complete as per specification and direction of E/I Each 1 1461.00 1304.46 1304.46 M/R
17 Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required. Meter 50 62.00 55.36 2767.86 M/R
18 Supplying and drawing low resistance co-axial T.V cable RJ-6 grade 0.7mm solid copper conductor PE insulated shielded with fine tinned copper braid and protected with PVC sheath in the existing PVC concuit etc. as required. Meter 460 33.00 29.46 13553.57 1.19
19 Supplying and fixing modular type TV antenna socket outlet on the existing box including making connection etc. as required. Each 23 119.00 106.25 2443.75 1.24.7
20 Supplying and fixing modular blanking plate on the existing modular plate & box excluding moduler plate etc. as required. Each 20 32.00 28.57 571.43 1.26
21 Supplying and fixing stepped type electronic fan regulator on the existing switch box including connections excluding modular plate etc. as required. Each 60 342.00 305.36 18321.43 1.25
22 Supplying and fixing call bell/ buzzer suitable for DC/AC single phase 230 volt complete etc. as required. Each 9 92.00 82.14 739.29 1.38
23 Supplying and fixing 8 way, Double Door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Each 1 1760.00 1571.43 1571.43 2.3.2
24 Supplying and fixing 16 way, Double Door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Each 8 2453.00 2190.18 17521.43 2.3.4
25 Supplying and fixing 3x4 way double door horizontal type three pole and Neutral sheet steel M.C.B. D.B, 415 Volts on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar , detachable gland plate, interconnection including painting, earthing etc. as required Each 1 3060.00 2732.14 2732.14 2.4.1
26 Supplying and fixing 3x6 way double door horizontal type three pole and Neutral sheet steel M.C.B. D.B, 415 Volts on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar , detachable gland plate, interconnection including painting, earthing etc. as required Each 1 3693.00 3297.32 3297.32 2.4.2
27 Supplying and fixing cable end box ( Loose wire box , IP 43) suitable for following three pole and Neutral sheet steel M.C.B. Distribution board, 415 volt on surface/ recess, complete with testing commissioning etc. as required 0.00 0.00
(i) For 4 way Double door TPN MCB DB Each 1 904.00 807.14 807.14 2.24.1
(ii) For 6 way Double door TPN MCB DB Each 1 1062.00 948.21 948.21 2.24.2
28 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required 0.00 0.00
(i) For 8 way, Double door SPN MCBDB Each 1 629.00 561.61 561.61 2.23.1
(ii) For 16 way, Double door SPN MCBDB Each 8 864.00 771.43 6171.43 2.23.4
29 Supplying and fixing of following rating C series MCB/ Isolator suitable for lighting and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required . 0.00 0.00
30 Supplying and fixing of following rating four pole 415V Isolator in the existing MCB DB & MCB VTPN DB complete witth connections ,testing and commissioning etc. as required . 0.00 0.00
40 Amp DP 240 volts Isolator Each 8 339.00 302.68 2421.43 2.12.1
40 Amp FP 415 volts Isolator Each 1 832.00 742.86 742.86 2.13.1
31 Providing and fixing MV danger notice plate of 200mmX150mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required. Each 1 226.00 201.79 201.79 2.21
EARTHING 0.00 0.00
32 Earthing with G.I earth pipe 4.5 mt. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with Charcoal/coke and salt as required. Set 2 5308.00 4739.29 9478.57 5.2
33 Earthing with GI earth plate 600mm X600 mm X6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal/ coke and salt as required. Set 2 6216.00 5550.00 11100.00 5.4
34 Providing and laying earth connections from earth electode with 6 SWG dia G.I. wire in 15 mm. Dia G.I.pipe from earth electrode including connection with G.I. thimble excavation and refilling etc. as required. Meter 80 188.00 167.86 13428.57 5.12
35 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc as required. Meter 100 57.00 50.89 5089.29 5.16
LAYING OF UNDER GROUND CABLE 0.00 0.00
36 Laying of one number PVC insulated and PVC sheathed/ XLE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushionig, protective covering and refilling the trench etc. as required. 0.00 0.00
(a) Above 95 sq. mm. and upto 185 sq.mm Meter 60 352.00 314.29 18857.14 7.1.3
37 Laying and fixing of one number PVC insulated and PVC sheathed aluminium conductor cable of1.1 KV grade of following size on surface etc. as required. 0.00 0.00
(a)Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) Meter 15 122.00 108.93 1633.93 7.7.3
38 Excavating for cable trenches of depth upto 1.2M in soft soil including getting out the excavated soil and disposal of surplus excavated soil directed within lead of 50 metres. Cum 6 333.00 297.32 1783.93 14.2
39 Filling available excavated earth (excluding rock) in tenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 metres. Cum 3 212.00 189.29 567.86 14.3
40 Providing and laying following size NP2 (Non pressure) RCC pipe complete with RCC collar etc. as required . 0.00 0.00
41 Laying of one number PVC insulated and PVC sheathed aluminium conductor cable of1.1 KV grade of following size in the existing RCC/ HUME/METAL pipe etc. as required. 0.00 0.00
(a) Above 95 sq. mm and upto 185 sq. mm M 5 64.00 57.14 285.71 7.5.3
42 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as reguired. 0.00 0.00
MAIN PANEL 0.00 0.00
43 Supplying and fixing of wall/floor mounted cubicle panel board fabricated with 16 guage iron sheet suitable for panel mounted switch disconnector, including busbar chamber, insulator, nut-bolt painting etc as required. (But without busbar copper strip) Sft 16 1382.00 1233.93 19742.86 BSR 2018 8.10.2
44 Supplying and fixing of following rating electrical items in the existing cubical panel board including drilling holes in cubicle panel making connections etc. as required . 0.00 0.00
Incomings:- 0.00 0.00
(ii) 200 Amp, 4 pole changeover switch . Each 1 9463.00 8449.11 8449.11 2.7.6
(b) Out going 0.00 0.00
(iii) 6/32 Amp SPN MCB 240 Volt Each 1 511.00 456.25 456.25 2.12.2
(vii) Copper strip of all sizes. Kg 8 776.00 692.86 5542.86 1830+Ana
(viii) Digital ammeter three phase Each 1 1643.00 1466.96 1466.96 8.10.6
(ix)Digital Voltmeter three phase Each 1 1337.00 1193.75 1193.75 8.10.4
(x)Pilot lamp for indicator Each 3 121.00 108.04 324.11 2318+Ana
SUPPLY & INSTALLATION OF FIXTURES 0.00 0.00
45 Supply and Installation of regular / standard model A.C. ceiling fan of 1200 mm sweep including wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated copper conductor, single core cable etc. as required. Each 60 1618.00 1444.64 86678.57 8.11.2
46 Supply and Installation of 300mm sweep 230 A.C. exhaust fan in the existing opening including making good the damage connection testing commissioning etc. as required. Each 34 1483.00 1324.11 45019.64 8.11.4
47 Supplying and fixing single wall mounted 20/22watt LED type batten fitting complete with electronic driver and LED tube etc. directly on ceiling / wall including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable and earthing the body etc. as required. Each 74 684.00 610.71 45192.86 5.9.3
48 Supplying and fixing surface mounted 10/12 watt LED type bulkhead fitting comprising of pressure die cast housing with acrylic diffuser (IP65) and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable and earting the body etc. as required. Each 8 1293.00 1154.46 9235.71 5.15
49 Supplying and fixing 4'*40 watt suspended type LED luminaire provides soft-light and glare free symmetrical illumination complete with all accessories etc including complete with all accessories etc. including ball and socket arrangement, 2 no. down rods of 20mm dia*1.6mm thick GI pipe upto 30 cm length, painting and wiring the down rods and connection with 1.5 sqmm FR PVC insulated copper conductor, single core cable and earthing etc. as required. Each 16 4949.00 4418.75 70700.00 5.14
50 Supplying and fixing surface mounted 15/18 watt LED downlighter with integrated electronic driver directly on ceiling including all accessories and connection with 1.5 sq mm FR PVC insulated copper conductor single core cable and earthing the body etc as required. Each 44 1380.00 1232.14 54214.29 5.11.7
51 Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required. Each 108 42.00 37.50 4050.00 1.33
52 Supplying and fixing batten / angle holder including connections with 1.5 sq.mm FR PVC insulated, copper conductor single core cable etc. as required. Each 126 46.00 41.07 5175.00 1.34
53 Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required. 0.00 0.00
SUPPLY OF UNDER GROUND CABLE 0.00 0.00
54 Supply of PVC insulated PVC sheathed aluminium conductor armoured under ground cable of graded 1.1 KV for working voltage upto 1100 volts conforming to ISI 1554 (Part-I) of 1964 with upto date amendment as detailed below. 0.00 0.00
TOTALexcl. Taxes 1739473.21
Construction of Residential Quarters at 400kV GIS Chandwa substation
Schedule-I of Price Bid
Name of the bidder 0 To,
Address 0 Contracts and Materials Department
0 POWER GRID CORPORATION OF INDIA LIMITED
0 VIDYUT BOARD COLONY, SHASTRINAGAR, PATNA-23
Sl. No. Name of Work Description Total Cost Estimate
A Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "Ground" 3,676,093.73
B Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "First floor" 4,166,385.38
C Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "2nd floor" 4,339,073.79
D Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "3rd floor" 4,478,531.72
E Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "4th floor" 3,710,449.35
F Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "Terrace" 1,335,809.59
G Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "Plinth" 3,748,305.56
H Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "PHE Works" 3,176,239.45
I Construction of Residential Quarters at 400kV GIS Chandwa substation As given in sheet "Electrical Works" 1,739,473.21
Total amount for the work "Construction of Residential Quarters at 400kV GIS Chandwa substation " 30,370,361.79
Above (+)and below (-)(in %): To be quoted by bidder
Quoted Price 30,370,361.79
GST (in percentage )@ on Quoted Price 0.00
Total amount including taxes 30,370,361.79
Note: If any part of price which required to be filled by bidder kept blank, the bid price shall be considered as inclusive and evaluation shall be done accordingly
Date 0 Printed name 0
Place 0 Designation 0
Construction of Residential Quarters at 400kV GIS Chandwa substation
Name of the bidder 0 To,
Address 0 Contracts and Materials Department
0 POWER GRID CORPORATION OF INDIA LIMITED
0 VIDYUT BOARD COLONY, SHASTRINAGAR, PATNA-23
We declare that following are our Total Bid Prices in Rupees for the expenditure incurred for the entire scope of work as specified in the specifications and documents. We have indicated Total Estimated Cost as indicated in the "Bill of Quantity(BOQ) & Prices" covering entire scope of works enclosed herewith as Schedule-I.
I Total for Installation/Services as per Schedule-I 30,370,362
II Total GST on services/Installation as per Schedule-I 0.00
III Toal BID Price including all taxes 30370361.79
Date 0 Printed Name 0
Place 0 Designation 0
RFX. No. 5002002028 NIT-403 Bid Form 2nd Envelope
BID FORM (Second Envelope)
Bid Proposal Ref. No.
Contract Services
Power Grid Corporation of India Ltd.,
Eastern Region Transmission System-I
Vidyut Board Colony Shastri Nagar
Name of Contract : Construction of Residential Quarters at 400kV GIS Chandwa substation
Dear Ladies and/or Gentlemen,
Schedule-I Service/Installation charges
2.4 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 We confirm that we shall also get registered with the concerned Goods and Service Tax Authorities, in all the states where the project is located.
4.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Annexures and attachments.xlsx
xlsx • 0.75 MB
Attachment-26 Declaration regarding events encountered pursuant to ITB Clause 2-1.docx
docx • 0.03 MB
Attachment-27.doc
doc • 0.04 MB
Attachment-28 (Bid Securing Declaration).doc
doc • 0.04 MB
Civil Works TS.pdf
pdf • 1.99 MB
Standard Field Quality Plan Civil Works for Site Packages Revision 04.pdf
pdf • 2.22 MB
01 Invitation for Bids (IFB)-Section-I.doc
doc • 0.16 MB
02 Sec-II ITB SSTE S&I R4-DCB-SRM-signed.pdf
pdf • 0.46 MB
03 Section - III BDS.doc
doc • 0.13 MB
03A Annexure A (BDS) QR.doc
doc • 0.05 MB
03B ANNEX-B (BDS) eRA.docx
docx • 0.02 MB
03D ANNEX-C (BDS) Sample E-stamp paper.pdf
pdf • 0.08 MB
03E ANNEX-E(BDS)-Undertaking for Authenticity.DOC
doc • 0.05 MB
04 Conditions of Contract Civil Works.pdf
pdf • 0.39 MB
04A GCC Civil Amendments I - X.pdf
pdf • 3.64 MB
05 SCC-Section-V.docx
docx • 0.07 MB
Annexure-D to BDS; e-reverse.pdf
pdf • 0.61 MB
Saftey Pact Latest.doc
doc • 0.06 MB
~$ SCC-Section-V.docx
docx • 0.00 MB
Integrity Pact.pdf
pdf • 0.51 MB
Sample Stamp Paper for Integrity Pact.pdf
pdf • 0.28 MB
Thumbs.db
db • 0.03 MB
Price_Schedule.xlsx
xlsx • 0.37 MB
revised_Annexure-D_-BDS-.pdf
pdf • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .