Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹18.4 CrAccepted-AOC 42 4 1 DESHMUKH NAGAR JUNI MIDC ROAD GODOLI SATARA | ₹18.4 Cr | l1 | Accepted-AOC AOV |
| 2 | Not Admitted-Finance 13 UTKARSH HOUSING SOCIETY SHARADA NAGAR CHOWK AMBAJOGAI ROAD LATUR 413512 | LATUR | MAHARASHTRA | 413512 | - | - | Not Admitted-Finance Not qualified for AOC |
| 3 | Not Admitted-Finance | - | - | Not Admitted-Finance Not qualified for AOC |
Tender Value
₹18.4 Cr
EMD Value
₹18.4 L
Closing Date
4 Mar 2024, 5:00 pmClosed
Additional Chief Executive Officer Z P Satara
Additional Chief Executive Officer Z P Satara
CONSTRUCTION OF NEW ADMINISTRATIVE BUILDING, PANCHAYAT SAMITI KOREGAON, TAL-KOREGAON, DIST-SATARA
2024_SATAR_1016674_1
work/north/L-6/building/01/24
Open Tender
Civil Works
730 days
CONSTRUCTION OF NEW ADMINISTRATIVE BUILDING, PANCH
OPEN
4 documents required · 4 mandatory
₹25,000
₹18.4 L
Additional Chief Executive Officer Z P Satara
26 Mar 2024
26 Feb 2024
5 Mar 2024
26 Feb 2024
4 Mar 2024
26 Feb 2024
29 Feb 2024
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means..
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 metre) by Mechanical Means.
Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/ murum watering, ramming etc. complete, (Lift from 1.5 To 3.0 metre) by Mechanical Means.
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing for basement or underground floor on a base of Cement concrete 1:3:6, including sub base of 2.50 centimetre thick Cement mortar 1:3 with conceal, setcrete (RMW), Algaeproof or other alike water proofing liquids, raking of joints upto 35 milimetre depth,filling the joints with 6 milimetre size crushed metal, hand grouting with cement slurry, curing and cleaning, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete).
Providing and laying in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist Slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/ pumping, compaction, finishing uneven and honeycombed surface with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade). (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin ).
First Floor
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-40 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
First Floor
Second Floor
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Pardi of required thickness including centering, formwork, cover blocks, laying/ pumping, compacting, curing, finishing and rougheningthem if special finish is to be provided and curing complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Second Floor
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
First Floor
Second Floor
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per square metre of vertical surface area covering 10 years guarantee on bond paper.
Providing and fixing 20 to 25 milimetre thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 milimetre between rough shahabad and Reinforced Cement concrete walls with cement grout mixed with water proofing liquid Algaeproof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 milimetre and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs. 100/- with ponding test etc complete. (excluding Cement concrtete 1:3:6 base concrete).
Providing fly ash brick masonary with conventional /Indian Standardtype fly ash bricks in cement mortar 1:6 in foundation and plinth including bailing out water manually, striking joints, racking out joints, watering and scaffolding complete.
First Floor
Second Floor
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete.
Providing Second class fly ash brick masonry with conventional /Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 milimetre diameter/ two hoop iron strips 25 milimetre x 1.60 milimetre at every third course, properly bent and bounded at ends scaffolding raking joints and watering complete.
First Floor
Second Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Reinforce Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete/ Burnt Brick Masonry and or tying by binding wire etc. complete.
First Floor
Second Floor
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
First Floor
Second Floor
Providing internal cement plaster 20 mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
First Floor
Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
First Floor
Second Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
First Floor
Second Floor
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen etc. complete.
Providing waterproofing in Water Closet and bath including brick bat coba in all position including providing and laying 12 milimetre bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound at the rate of 1kg/ per bag of cement laying brick bat coba of required thickness in cm 1:5 with waterproofing compound 1 kilogram per bag of cement grouting and finishing the top layer with 20 milimetre thick brick bedding in cement mortor 1:3 with waterproofing compound 1 kilogram per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.
First Floor
Second Floor
Providing water proofing treatment as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at the rate of 14.50 kg per 10 Sqm. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
First Floor
Construction of precast Reinforced Cement Concrete railing of M30 Grade, aggregate size not exceeding 12 milimetre, true to line and grade, tolerance of vertical Reinforced Cement Concrete post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 milimetre, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications etc. complete.
First Floor
Second Floor
Providing, laying & fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for Flooring of approved colour and design 22 +/ -2 milimetre thick bayer colour pigmented as per Indian Standard 1237 -1980 having compressive strength more than 500 kilogram per square centimetre reaffirmed in 2006, having wert transvrse strenghth of 3.5/milimetre 2, water absorption less than 10 percent abrasion/ wear resistance less than 2 milimetre , skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN-51094 like ultra tiles 300 x 300 milimetre or equivalent, in plan/ designed pattern on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and laying in position flooring of telephone black/ Amba White/ Cat bary brown/ Ruby red/ Ocean Brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortar 1:3 curing and cleaning etc. complete.
First Floor
Second Floor
Providing and laying telephone black/ Amba White/ Cadbury Brown/ Ruby red/ Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. on Cement Mortar 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete.
First Floor
Second Floor
Providing leather finished polishing to Granite Stone slab by continuous grinding in 4 coats of different bits to receive rough and matt finish including buffing process before laying and fixing of stone as per drawing and design, including cleaning, washing and finishing etc. complete.
Providing and fixing machine cut machine polished 18 milimetre to 20 milimetre thick telephone black/ Amba White/ Cat bary brown/ Ruby Red/ Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.
Second Floor
Providing and laying polished Kotah stone flooring 25 millimeter to 30 millimeter thick and of reqd. width in plain/ diamond pattern on a bed of 1:6 cement mortar including cement float,filling joints with neat cement slurry,curing,polishing and cleaning complete.
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 milimetre to 30 milimetre thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete.
Providing, laying & fixing exterior grade fibrilling fibre reinforcement heavy duty designer cement concrete tiles for For steps and dado of approved colour and design 22 +/ -2 mm thick bayer colour pigmented as per Indian Standard 1237 -1980 having compressive strength more than 500 kilogram per square centimetre reaffirmed in 2006, having wert transvrse strenghth of 3.5 per square milimetre, water absorption less than 10 percent abrasion/ wear resistance less than 2 milimetre, skid resistance more than 25.0 (ASTM:E303) and no fading as per DIN-51094 like ultra tiles 300 x 300 milimetre or equivalent, in plan/ designed pattern on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete.
Providing and laying vitrified stone effect finish tiles for Flooring having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and conforming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
First Floor
Second Floor
Providing and laying vitrified stone effect finish tiles for Skirting having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and conforming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
First Floor
Second Floor
Providing and laying vitrified matt fininsh tiles for flooring having size 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete.
First Floor
Second Floor
Providing and laying vitrified mirror / glossy finish tiles for Skirting having size 590 milimetre to 605 milimetre x 590 milimetre to 605 milimetre of 8 to 10 milimetre thickness and confirming to IS. 15622-2006 (group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.
First Floor
Second Floor
Providing and fixing Manglore tiled roofing with class "AA" tiles including securing the last course of tiles near the eaves with steel flat 40 milimetre x 3 milimetre and 1.22 milimetre wire fixing country teak wood sloping battens of 25 x 12 milimetre teak wood horizontal battens of 50milimetre x 25 milimetre over the sloping battens, all iron work and coal tarring the battens complete (excluding ridge and hip tiles)
Second Floor
Providing and fixing Manglore tile ridge and hip tiles of class "AA" including scaffolding if necessary, pointing with coloured cement mortar and curing complete.
Second Floor
Providing and fixing valley gutter of 22 B.W.G. (0.8 milimetre) plain galvanised iron sheets 120 centimetre wide with teak wood planking 20 milimetre thick including two coats of coal-taring the upper surface of plank (excluding painting to under side of plank)
Providing and fixing in position (as per I.S.1868:1982) Aluminium sliding window of two tracks with rectangular pipe having overall dimension 63.50 x 38.10 x 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 x 31.75 x 1.20 milimetre at weight 0.695 kilogram per running metre, Top and side track section 61.85 x 31.75 x 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre . As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts etc, complete with colour Anodising with box.
Providing and fixing in position (as per 1868:1982) aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre . Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete with colour Anodising with box.
First Floor
Second Floor
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter compr Indian Standard Institute ng of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre, 2.90 milimetre thick top rails 47.62 x 44.45 milimetre, 3.18 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels, Indian Standard Institute mark, heavy duty, Hydraulic floor spring of 150 kilogram capacity, having heavy duty concealed lock, necessary beeding, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipments etc. complete.
First Floor
Second Floor
Providing & fixing factory-made Single leaf 2 hour fire rated door as per IS 3614 Part 2 & BS 476 Part 20 & 22, tested to UL 10 C and conforming to NFPA 80 , tested at NTL /CBRI/ARAI of Plain Steel finish type with a.) Frame of size 143x58 mm and thickness of 1.6 mm thick skin pass galvanized iron sheet (Conform to IS 277 ) formed to single or double rebate profile b.) Shutter of 46 mm thickness and constructed from 1.2 mm thick skin pas galvanized iron sheet (Conform to IS 277) infill Rockwool / Mineral wool/ Honey comb craft paper c.) Vision glass of 5mm thick clear/wired glass Circular or Rectangular d.) Finish : Primed with zinc phosphate stoving primer and finished with Polyurethane aliphatic grade or epoxy paint as required of thickness 60 micron e.) Accessories : Min 8 Anchor fastener of HILTI make, min 3 SS Ball Bearing Butt Hinges, Mortise sash lock with lever handle, Mortise dead bolt , Mortise latch , Door closer , Panic bar and external trim lock and Flush bolts complete.
First Floor
Second Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing and fixing in position Colour Anodized aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineer in Charge with all necessary aluminium sections including necessary fixtures and fastening with 5 milimetre thick clear float glass etc. complete.
Providing and fixing in position Gypsum board false ceiling with 12.5 milimetre thick Gypsum boards, screwed/ fixed to the under structure of suspended galvanised iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 milimetre maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete.
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with cement mortar1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layers of same mortar added with jute fiber at 1 kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 milimetre x 300 milimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete.
Providing and fixing 37 mm thick factory made PVC Door shutter, styles and rails made of PVC hollow extruded printed and laminated section having overall dimension 115 mm x 37 mm with wall thickness 2 mm (± 0.2 mm) with inbuilt beading on one side, the styles and rails mitred cut and joint at corners by inserting 2 nos PVC profile reinforcement of size 75 mm x 200 mm long with cross section size of 29 mm x 31 mm having wall thickness 2 mm (± 0.2 mm). Styles, rails and reinforcements to be fusion welded together. Only hinge side vertical style to be reinforced with PVC profile reinforcement in full length. Printed and laminated PVC lock rail of size 110 mm x 37 mm having wall thickness 2 mm (± 0.2 mm) to be welded horizontally with the vertical styles after inserting PVC profile reinforcement as in styles and rails, providing with PVC snap fit beading, panels of 100 x 20 mm printed & laminated and inserting 2 nos 6 mm dia bright steel rod horizontally with both side threaded and tightened with check nuts and washers complete, all as per manufacturer's specification and direction of engineer-in-charge.
First Floor
Second Floor
Providing and fixing frame with / without ventilator of size as specified with teak wood for doors and windows including chamferring, rounding, rebating, iron holdfast size 300 milimetre x 40 milimetre x 5 milimetre with oil painting complete.
First Floor
Second Floor
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats.
Providing and fixing the country cut teak wood double or single leaf second class fully pannelled door shutter with 35 milimetre thick style and rail with 25 milimetre thick pannels with openable fan light as per detailed drawings. Excluding the door frame 60 milimetre x 100 milimetre, including stainless steel fixtures and fastening and finishing the wood work with oil panting 3 coats.
Providing and fixing solid core flush door shutter in single leaf 32 milimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 milimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete.
First Floor
Second Floor
Providing and fixing country cut teak wood window with double leaf half glazed and half panelled shutter with style 70 x 20 milimetre thick rails 95 x 20 milimetre thick and pannels 15 milimetre thick with ventilator including wrought iron hold fast, stainless steel fixtures and fastenings and finishing the wood work with oil painting 3 coats etc. complete.
Providing and fixing mild steel grill work for windows, ventilators 20 kilogram per square metre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete.
First Floor
Second Floor
Polishing applying malamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying french polish, scaffolding if required etc. complete.
Providing and applying interior wall finish luster of Asian/ Berger/ Nerolac/ Dulux Paints or equivalent make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean. Applying Asian/ Berger/ Nerolac/ Duuex Paints or equivalent wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. Applying Asian/ Berger/ Nerolac/ Dulex Paints or equivalent Acrylic wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent wall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, Applying Asian/ Berger/ Nerolac/ Dulux Paints or equivalent interior wall finish luster 1st coat with brush/ rubber/ spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat of Asian / Berger / Nerolac / Dulux Paints or equivalent interior wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity (With prior approval of S.E.).
First Floor
Second Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete.
First Floor
Second Floor
Providing and applying two coats of textured synthetic paint approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing the surface by thoroughly cleaning oil, grease, dirt and other materials as required complete.
First Floor
Second Floor
Providing and Fixing Processed Stone Cladding on wall surface/ plywood surface. RCC pardi/ Wall and all type of Interior, Exterior Compound wall and Gate etc. of cladding processed stone with material of Processed clay, Wooden chips, Silica sand, Cement, GFRC admixtures, Colour pigments, Fiber up to thick of 230 mm/ 25 mm including scaffolding, fixing of screw, etc. (As directed by Engineer in Charge)
Providing and applying white-wash in one coat on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down complete.
First Floor
Second Floor
Providing and applying priming coat over concrete/Masonry/Asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, greese, dirt and other foreign matter and sand papering as required complete.
First Floor
Second Floor
Providing expansion joints in reinforced cement concrete framed structure (exterior columns) with plain premoulded filler 25 milimetre thick with 40 milimetre wide and 1 mm thick stainless steel plate, hold fast, fixing Teak wood battens on internal face finishing etc. complete as directed.
First Floor
Second Floor
Providing and laying ceramic tiles having size 30 centimetre x 30 centimetre conforming I.S.15622/2006 (group D II-A) and 7 to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/ colour cement slurry cleaning curing etc. complete.
Providing and laying ceramic tiles having size 30 centimetre x 30 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing and laying ceramic tiles having size 30 centimetre x 30 centimetre conforming I.S.15622/2006 (group D II-A) and 7 to 8 milimetre thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/ colour cement slurry cleaning curing etc. complete.
Providing and laying ceramic tiles having size 30 centimetre x 30 centimetre for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete.
Providing expansion joints in Reinforced cement concrete framed structure (at floor level) with plain premoulded filler 25 milimetre thick with 40 milimetre wide and 1 milimetre thick stainless steel plate, holdfast, fixing teak wood battens on internal face finishing complete as directed.
First Floor
Second Floor
Design and execution of post tensioning works, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands PVC sheathing jointing with couplers and inserting the strands, profiling, fixing live end anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, making dead end anchorages, including, fixing tendon support bars, supervising the fixing of bursting reinforcement, stressing the cables, end trimming, with required tools, plants, and machineries, and consumables etc. at all heights including all leads, lifts, coordination,
Providing detailed report of Inspection logging of drilled hole by observing visual description of data as per depth, thickness of layer, type of sample, wash sample, core recovery type of drill complete.
Design, supply, fabrication and fixing of SS, non glare multilingual Braille (raised dots) entrance signage (size 1 ft x 1 ft) as per the approved design and make,indicating the name of the building. Having 1.2mm thick SS non glare blue coloured base plate with the 'Universal Accessibility Symbol' and Upper case Sans Serif words of height 15mm engraved on it along with the equivalent word/ s written in Hindi using Devnagri script of height 15mm in white colour. Grade 2/ Grade 1 Braille to be etched/ engraved and be raised 0.5mm above base plate.The signage to be installed at the specified location on the compound wall near the site entrance gate installed at a height of 1200 mm from the finished ground/ floor level, using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge.
Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the engineer in charge.
Providing soak pit of size 120 centimetre x 120 centimetre x 120 centimetre including excavating and filling with brick-bats.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300 milimetre thick sidefilling around outside of RCC rings (annular space) with 40 milimetre size boulders including filling of recharge pit up to 0.5m depth with 25-75 milimetre clean washed gravels from bottom up followed by 0.5m depth of 10-25 milimetre of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including necessary (excluding excavation and laying)
Providing and fixing white european type wall-hung, of size 360 milimetre x 360 milimetre x 575 milimetre with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100 milimetre dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.
Providing and fixing 1st class white glazed earthenware 'Orisa Type' Water Closet Pan 580 milimetre diameter including 'P' or 'S' trap cast iron soil and vent pipe upto the outside face of the wall (1:5:10) cement concrfete bedding 15 milimetre thick 10 litre Poly Venyl Chloride flushing cistern with all necessary pipe connection complete.
Providing and fixing Oval Type Under Counter Wash Hand Basin of 420 x 590 x 195 milimetre size with pillar cock, C.P.Angular stop cock, long thread of approved make continental including SS bottle trap of necessary pipe connection up to the outside face of the wall, having Telephonic Black / Colour Granite of 180 milimetre thick fixed on Black Kadappa Framework, etc. Complete as directed by Engineer in charge.
Providing and fixing white glazed urinal of series with Pressmatic auto closing valve of having 32 milimetre diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge.
Providing & fixing 15 milimetre diameter Poly Vinyl Chloride Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc. complete.
Providng and fixing stainless steel sink of size 600 x 510 x 200 millimeter of Nirali or equivalent make including coupling, outlet pipe, elbow and other necessary fitting, finishing complete.
Providing and fixing Crome Plated sink cock with raised J shaped swinging casted spout of approved make including necessary sockets/union nut etc. complete.
Providing and preparing kitchen otta up to 75 cm width, made up from 30 milimetre thick and 75 centimetre high vertical support for kadppa at 1 metre center to center of 25 milimetre thick both side polished kadappa middle shelf and bottom of 20 milimetre thick one side polished kadappa with facia patti of 20 x 50 milimetre kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete.
Providing and fixing Crome Plated BIB cock with wall flange of approved make including necessary sockets/union nut etc. complete.
Providing and fixing Crome Plated Two way BIB cock of approved make including necessary sockets/ union nut etc. complete.
Providing and fixing 10centimetre cast iron Nahani Trap includingcast iron grating ,bend and piece of cast iron pipe upto the outside face of the wall complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 225 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 150 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and laying concrete pipe of Indian Standard Non Pressure class of 300 milimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre and 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and air tight cast iron C. I. cover of 75 Kg with lid and frame fixed in cement concrete etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre and 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and air tight cast iron lid 75 kilogram with frame fixed in cement concrete complete.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre x 45 centimetre x 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stone Ware pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete cover medium duty 140 kilogram with frame etc. complete.
Providing and fixing on walls / ceiling / floor 25 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed complete.
Providing and laying in trenches 32 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary excavation, fittings, refilling trenches. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls / ceiling / floor 50 milimetre diameter Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion complete.
Providing and fixing 100 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Providing and fixing 75 milimetre diameter stabiliser pipe /Poly Venyl Chloride soil vent /waste pipe and with necessary fixtuers and fiting such as bends, tees, single junctions slotted vent, clamps complete.
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
Providing and fixing Poly Venyl Chloride Rain water pipes of 160 milimetre outer diameter and having wall thickness of 2.2 to 2.7 milimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Venyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 milimetre to 40milimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on Cement Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 years for any leakages or dislocations of pipes. All the Poly Venyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge complete. (The contractor shall give 3 years guarantee bond for payment).
Providing and making Indian Standard Institute Mark ferrule connection of 25 milimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing and making Indian Standard Institute Mark ferrule connection of 50 milimetre diameter to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing and fixing 15 centimetre x 10 centimetre salt glazed stoneware gully trap in cement concrete 1:4:8 out side the building including cast iron grating in the sink, connecting glazed stonewre pipe brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and fixing during laying in Reinforced Cement Concrete Slab rectangular 2 milimetre thick Mild Steel sheet fan hook box of size 180 x 100 milimetre with required depth with holes or notches as required, bottom and top sides of 1.6 milimetre Mild Steel sheet fixed with 3.5 milimetre diameter round headed screws together with 12 milimetre diameter Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface
Providing and fixing 450 milimetre x 550 milimetre size superior type Belgium mirror with 16 milimetre diameter nickel plated towel rod complete.
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts complete.
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts, complete.
Removing other type truss below 5 metre span from roof and stacking the materials as directed with all leads and lifts complete.
Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts, complete.
Dismantling stone masonry in lime or cement mortar including stacking the materials as directed with all leads, lifts complete.
Removing G.I or A.C.sheet roofing including purlines, principal rafters including sorting serviceable and unserviceable materials, stacking the same as and where directed in the compound including scaffolding complete.
Providing and applying Two coats of wall care Putty of 2 milimetre thickness for plastered surface and 5-6 milimetre thickness finished concrete surface to Ceiling and Walls to prepare surface even and smooth of Brands BIRLA WHITE, BERGER, BISION, J.K., make, etc complete for plastered walls/ceiling 2 mm.
First Floor
Second Floor
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Semi Barrier type Kerb with gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
Excavation for roadway in earth soil of all sorts, sand, gravel or soft murum including dressing section to the required grade camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Providing and casting in situ or precast tapering Reinforced Cement Concrete Mix-20 Barrier type Kerb without gutter (as per IRC:86-1983) embedded 125 milimetre below ground level over Mix-10 Plain Cement Concrete finished neatly with Cement Mortar 1:2, setting the same in Cement Mortar 1:2, including the required excavation in any strata and removing the excavated stuff anywhere in city and redoing the surface as specified and directed by Engineering In-charge. Using Concrete Batching and Mixing Plant.
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing trap rubble stone paving 15 centimetre thick in cement mortor 1:3 over a bedding of 15 centimetre thick cement concrete 1:4:8 proportion with trap metal including striking joints and watering etc. complete.
Providing and laying in situ cement concrete M-20 with tremix treatment for 100 milimetre thickness for flooring with groove cutting of 4 milimetre wide and 20 milimetre deep with necessary refilling with bitumen etc. complete.
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting, dewatering etc. complete. (Lift upto 1.5 metre) by Mechanical Means..
Filling in plinth and floors with contractors material/ brought from outside and approved by Engineer incharge in layers of 15 centimetre to 20 centimetre including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-15 of trap/ granite/ quartzite/ gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/ steel formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying/ pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided, (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/quartzite/ gneiss metal for Reinforced Cement Concrete Beams and Lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks, laying/ pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and laying Cast in situ/ Ready Mix cement concrete in Mix-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying/ pumping, compacting , curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Superwisery Control and Data Acquisitionenabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand V.S.I. Grade).
Providing and fixing in position Thermo Mechanically Treated (TMT) FE -500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.
Providing fly ash brick masonary with conventional /Indian Standard type fly ash brick in cement mortar 1:6 for superstructure including striking joints, racking out joints, watering and scaffolding complete.
Providing internal cement plaster 12 milimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc. complete.
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
Providing water proofing treatment as per IS : 1346-1966 to generally inaccessible sloping Reinforced Cement Concrete Terrace slab with bitumen felts in all positions in five course, consisting of applying cold bitumen primer coat at the rate of 2.5 litre per 10 Sqm., hot bitumen layer at the rate of 14.50 kg per 10 Sqm. and over the same layer of bitumen felt of type III grade (I) as per IS: 1332-1965 across the slope with 10 cm overlap commencing at lowest level and again applying hot bitumen course at the rate of 14.50 kg per 10 Sqm. and finally spreading over it grit at the rate of 14.50 kg per 10 Sqm. including all lifts, leads and scaffolding whenever necessary complete as directed with four years' guarantee on requisite stamp paper etc. complete.
Providing and laying vitrified stone effect finish tiles for Flooring having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and conforming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and laying vitrified stone effect finish tiles for Skirting having size 590 to 605 milimetre x 590 to 605 milimetre of 8 to 10 milimetre thickness and conforming to Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete.
Providing and fixing Manglore tiled roofing with class "AA" tiles including securing the last course of tiles near the eaves with steel flat 40 milimetre x 3 milimetre and 1.22 milimetre wire fixing country teak wood sloping battens of 25 x 12 milimetre teak wood horizontal battens of 50milimetre x 25 milimetre over the sloping battens, all iron work and coal tarring the battens complete (excluding ridge and hip tiles)
Providing and fixing Manglore tile ridge and hip tiles of class "AA" including scaffolding if necessary, pointing with coloured cement mortar and curing complete.
Providing and fixing in position (as per 1868:1982) aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 milimetre at weight 0.637 kilogram per running metre with window frame bottom track section 92 x 31.75 x 1.30 milimetre at weight 1.070 kilogram per running metre . Top and side track section 92 x 31.75 x 1.30 milimetre at weight 0.933 kilogram per running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 milimetre at weight 0.417 kilogram per running metre. Inter locking section 40 x 18 x 1.10 milimetre at weight 0.469 kilogram per running metre and handle and top section 40 x 18 x 1.25 milimetre at weight o.417 kilogram per running metre. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete with colour Anodising with box.
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 metre x 2.40 metre with aluminium door frame of powder coated section 101.60 x 44.75 milimetre, 3.18 milimetre thick and shutter comprising of powder coated section having bottom and lock rail of size 150 milimetre x 44.5 milimetre x 3.00 milimetre thick top rails 47.62 x 44.45 milimetre x 3.00 milimetre thick, vertical style 47.62 x 44.45 milimetre, 3.00 milimetre thick and for shutter plain glass panes 5 milimetre thick for top panels and 12 milimetre thick both side laminated phenol bonded particle board panels for bottom panels etc., Indian Standard Institute mark, with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, Poly Venyl Chloride gaskets, 250 milimetre length tower bolts, 150 milimetre diameter pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials, labours and equipment etc. complete.
Providing and fixing mild steel grill door 24 kilogram per squaremetre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etc
Providing and applying plastic emulsion paint of approved quality, colour and shade to old/ new surfaces in two coats including scaffolding, preparing the surface. (excluding the primer coat) complete.
Providing and applying two coats of textured synthetic paint approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing the surface by thoroughly cleaning oil, grease, dirt and other materials as required complete.
Providing and fixing mild steel grill gate with angle iron frame 65 milimetre x 65 milimetre x 10 milimetre with iron bars at 150 milimetre centre to center and diagonal flats as per the detailed drawing including hinges, pivot blocks locking arrangement welding, revetting with oil painting in three coats of approved colour shade. Weight of gate 35 kilogram per square metre.
Laboratory testing charges for various material required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune SOIL / MURUM Compaction Test (Proctor Density).
SOIL / MURUM Liquid limit & plastic Limit test.
SOIL / MURUM Field Density test by Sand Replacement Method.
SOIL / MURUM Field Density test by Sand Replacement Method.
SOIL / MURUM Liquid limit & plastic Limit test.
SOIL / MURUM Field Density test by Sand Replacement Method.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BASIC TEST OF AGGREGATE. Water Absorption, Specific Gravity,Impact Value Crushing Value test.
BASIC TEST OF CEMENT.Standard Consistancy Fineness, Specific Gravity, Setting Time ( Initial & Final ), Compressive Strength and Soundness test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
Concrete Mix Design (With all Tests on basic materials).
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
Concrete Mix Design (With all Tests on basic materials).
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
Concrete Mix Design (With all Tests on basic materials).
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
STEEL BAR TESTING Upto 16 mm (Set of 3 Bars)
STEEL BAR TESTING Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress).
STEEL BAR TESTING Upto 16 mm (Set of 3 Bars)
STEEL BAR TESTING Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress).
STEEL BAR TESTING Upto 16 mm (Set of 3 Bars)
STEEL BAR TESTING Above 16 mm (Set of 3 Bars) (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress).
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CONCRETE Compressive Strength OF Cement Concrete Cube (Set of 3 cubes) test.
BASIC TEST OF AGGREGATE. Sieve Analysis test.
BASIC TEST OF AGGREGATE. Flakiness Index/ Elongation Index test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
BRICKS Water Absorption (Set of 5 Bricks), Compressive Strength ( Set of 5 Bricks), Efflorescence (Set of 5 Bricks) test.
MORTOR Compressive Strength ( Set of 3 Cubes) test.
FINE AGGREGATES. Fineness Modulus (Sieve Analysis),Silt & Clay Content test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
FLOORING of Natural stone (Kota/Marble/Granite/Tandur etc.) Water Absorption, Specific Gravity test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
MANGLORE TILES Water Absorption (Set of 6 Tiles), Flexural test (Set of 6 Tiles) test.
MANGLORE TILES Water Absorption (Set of 6 Tiles), Flexural test (Set of 6 Tiles) test.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test on Powder Coating.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test on Powder Coating.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
ALUMINIUM SECTION Test on Powder Coating.
ALUMINIUM SECTION Test for Thickness, Mass Per Running meter.
WOOD Density, Moisture Content test.
WOOD Density, Moisture Content test.
WOOD Density, Moisture Content test.
WOOD Density, Moisture Content test.
WOOD Density, Moisture Content test.
FLUSH DOOR Knife Test, Adhesion Test, End Immersion Test.
FLUSH DOOR Knife Test, Adhesion Test, End Immersion Test.
FLUSH DOOR Knife Test, Adhesion Test, End Immersion Test.
WOOD Density, Moisture Content test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
PAINT / THERMO-PLASTIC PAINT Reflectance & yellowness index Test.
PAINT / THERMO-PLASTIC PAINT Flowability (Percentage residue) Test.
PAINT / THERMO-PLASTIC PAINT Softening Point (Ring & ball method) Test.
PAINT / THERMO-PLASTIC PAINT Drying Time Test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
CERAMIC TILES / VITRIFIED TILES Water Absorption, Moduls of Rapture (Set of 6 Tiles) test.
Supplying and erecting PVC trunking (PVC casing- n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
Supplying and erecting PVC trunking (PVC casing- n-capping) of size 32 mm with accessories on wall/ceiling as per specification No WG-MA/CON [1-2-8]
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with PVC accessories on wall /ceiling as per specification No WG-MA/CON. [1-2- 4]
Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessories on wall / ceiling as per specification No WG-MA/CON. [1-2- 5]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG- MA/BW [1-3-1]
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-2]
Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG- MA/BW [1-3-2]
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG- MA/BW [1-3-3]
Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-4]
Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG- MA/BW [1-3-4]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type switch 16 / 20 A with indicator duly erected on provided plate and box with wiring connections complete. [1-6-6]
Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-11]
Supplying and erecting modular type telephone socket one gang with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-15]
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO [1-12-2]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. [1-6-26]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected. [1-6-27]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected. [1-6-28]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 12 module duly erected. [1-6-32]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-19]
Point wiring for ceiling fan in PVC trunking (casing- capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG- PW/SW [1-7-20]
Wiring for plug on board with Switch socket surface/concealed type copper wiring and earthing and with modular accessories as per specification No WG-PW/CW [1-7-26]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. [2-11-2]
Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire. [2-11-6]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-19]
Supplying and erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-1]
Supplying and erecting 10 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-5]
Supplying and erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation polyester taped Nylon Rip Cord & grey colour sheathed with FR PVC conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-6]
Supplying and erecting 20 pair 0.5mm dia jelly filled unarmoured telephone copper cable with poly-al laminate moisture barrier laid in provided PVC casing capping/conduit as per specification No. WG-TW [1-8-10]
Supplying, Erecting and Commissioning of MDF Box 150x150 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW [1-9-3]
Supplying, Erecting and Commissioning of 10 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-11]
Supplying, Erecting and Commissioning of 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW [1-9-12]
Supplying, Erecting and Commissioning of 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW [1- 9-18]
Supplying and erecting 0.5 mm dia copper jumper wire as per specification No. WG-TW [1-8-17]
Supplying, Erecting and Commissioning of digital (hybrid) type EPABX of 14 x 228 extensions suitable upto 96 extensions complete. Basic Rate = 60679/- Additional 8 Trunk line Card 1 Nos = 22025/- 16 Extension Card 6 Nos = 38159/- x 6 Nos = 228954/- Total rate = 311658/- + 5% = 327240.90/-
Supplying and installing expansion cabinet for extension of digital hybrid EPABX to expand system by 32 ports with programming and configuration of extensions and Direct lines with required accessories complete. [1-9-33]
Supplying, Erecting and Commissioning of push button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete. [1-9-29]
Supplying, Erecting and Commissioning of push button telephone instrument desk top unit as per specification complete [1-9-28]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1- 10-1]
Supplying, fixing, and configuring 24 ports with 4 (SFP+) port ethernet managed switch with web view/CLI 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS [1-11-4]
Supplying and fixing 24 port patch panel with tool- less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP [1-12-4]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
Supplying, installing & testing UTP connector (RJ- 45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing 1 m length UTP patch cord of enhanced Cat 6 type with 4-connector channel performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC [1- 10-17]
Supplying and installing armoured single mode optical fibre cable with 6 fiber core dia 50/125µm (OS1/OS2) 10/40 GBPS speed in provided underground HDPE pipe complete. [1-10-9]
Supplying and fixing SC/LC type multimode pigtails (OM3) for LIU to terminate OFC in LIU as per specification No. WG-NAS/LIU2 [1-12-13]
Supplying and fixing 12 ports light guide unloaded interconnect unit rack mounted type with adapter panel for termination of optical fibre cables in provided U rack complete as per specification no. WG-NAS/LIU [1-12-5]
Supplying, fixing, and configuring 1-port mini-GBIC SX MM fibre transceiver (up to 550m support 3.3V power) erected in provided rack complete. [1-11- 16]
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die- cast aluminium housing polystyrene diffuser having system lumens output of Min. 2000 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-5]
Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die- cast aluminium housing polystyrene diffuser having system lumens output of Min. 2750 Lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-6]
Supplying and erecting LED Panel Light(600mm X 600mm) Max. 30 W having CRCA powder coated housing polystyrene diffuser having system lumens output of Min. 3600 Lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. max. ripple of 5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. [2-1-7]
Making suitable size of recess in any type of false ceiling for erection of flush type LED panel light 600mm x 600mm/1200x300mm and finishing the background to match the original ceiling surface. [2- 1-14]
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-16]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing heat sink integrated HF electronic driver Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt CRI>80 CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty. [2-1-22]
Supplying and erecting gong with double coil suitable for 230V complete erected on polished wooden block. [2-3-12]
Supplying and erecting ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size. [2-3-13]
Supplying and erecting 3W 230V integral type LED Lamp suitable for B-22 / E-27 base. [2-8-9]
Supplying and erecting 10-12W 230V integral type LED Lamp suitable for B-22 / E-27 base. [2-8-11]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying, installing, testing and commissioning of split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor. room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 5.0 suitable to operate on 250V 50 Hz A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser minimum 2.5PM filter self diagnosis feature stabilizer free operation & temperature display on indoor unit noise level maximum 50dBA at position in provided recess with wooden frame complete specification no. AP-AC/WAC [3-2-13]
Supplying, installing, testing and commissioning of split type room air conditioning unit 2.8TR to 3.2TR capacity with refrigerant R32 415V 50 Hz A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit noise level maximum 50dBA at position as per specification no. APAC/ WAC [3-2- 16]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. [3-2- 26]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 16mm complete. [3-2- 27]
Supplying and erecting seamless outside & inside smooth dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. [3-2- 28]
Supplying, erecting, testing and commissioning of self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC22 [3-3-9]
Supplying and erecting ultra violet water purifier with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire two indicator lamps dual function cartridge with output of purified water 1 litre/min with activated carbon filter and softener operating on 230V single phase A.C. supply with UV fail & filter change indication system. [3-5-2]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. [4-2-9]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC system. [4-2-10]
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater/AC system. [4-2-12]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. AC outdoor Units = 120 Kg Meter Panel = 35 Kg [6-1-19]
Supplying, erecting and marking SPMCB 6A to 32A C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking TPMCB 40A to 63A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-11]
Supplying, Erecting and Commissioning of 2 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-2]
Supplying, Erecting and Commissioning of 4 pole RCCB 40A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB [5-6-5]
Providing and erecting 4 Pole MCCB 415 V 100A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides insulation withstand capacity 800V no line- load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-1]
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-9]
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW- SWR/MCBDB1 [5-4-16]
Supplying and erecting triple pole and neutral distribution board (TPNDB) 3 pole/ 4 pole MCCB as incomer & outgoing SP MCB (12 poles) or TP MCB of 4 ways (12 poles) with door 1.2mm thickness surface/flush mounted on iron/GI frame (vertical busbar type) as per specification no. SW- SWR/MCBDB1 [5-4-15]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 4 ways/phase (12 poles) with door 1.2mm thickness surface/flush mounted IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-1]
Supplying and erecting triple pole and neutral distribution board (TPNDB) SPMCB of 8 ways / phase (24 poles) with door 1.2mm thickness surface/ flush mounted IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB [5-4-2]
Supplying and erecting terminal spreaders suitable for 3 pole up to 250A MCCB (set of 6) [5-11-2]
Supplying and erecting extended rotary handle for MCCB with adjustable telescopic rod suitable for up to 250A MCCB. [5-11-14]
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB. [5-11-18]
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010 [6-1- 14]
Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green 230 / 250V on provided box / panel with necessary material wiring & connections etc. [6-5-5]
Supplying and erecting LED type indicating pilot lamp with LED colour blue 230 / 250 V on provided box / panel with necessary material wiring & connections etc. [6-5-6]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL [7-1-15]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL [7-1-20]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-10]
Providing and erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. ( for all floors to lay LV Electrical Cables) [7-11-11]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials testing & recording the results as per specification no. EA-EP [9-1-3]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. 30mtr x 0.596 Kg/m = 17.88 Kg [9-2-3]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA- EP [9-1-2]
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. ( 0.1155 Kg/m x 30mtr x 2 Run = 6.93 Kg) [9-2-4]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in - 10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13- 11-2]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]
Supplying, erecting, testing and commissioning of rust free microphone table stand of chrome plating/powder coating or S.S. material up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete. [13-11- 5]
Supplying and erecting PVC trunking (PVC casing- n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV [1-3-14]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting modular type (two module) electronic step regulator for fan duly erected on provided plate and box with wiring connections complete. [1-6-23]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG-PW/SW [1-7-19]
Point wiring for ceiling fan in PVC trunking (casing- capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire modular type switch earthing and required accessories as per specification No WG- PW/SW [1-7-20]
Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17W with high transitivity diffuser with system lumens output of Min. 2000 lumens min. efficacy of 120 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 120-270V surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-17]
Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing having system lumens output of Min. 4400 Lumens min. efficacy of 110 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.95 operating range of 140-270V inbuilt surge protection of 10 kV Life class of 50 000 Hrs. at L70B50 including driver complete with 3 Years warranty as per specification No FG- ODF/FLS2. [2-4-4]
Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min. 3000 Lumens min. efficacy of 100 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. ( Name board illumination purpose) [2-4-12]
Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing having system lumens output of Min. 12000 Lumens min. efficacy of 120 lumen/W CRI>70 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-270V inbuilt surge protection of 4 kV Life class of 50 000 Hrs. at L70B50 including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. ( Building illumination purpose on concrete box) [2-4-15]
Supplying and erecting integrated LED Bollard Cylindrical/Cubical shaped 500mm 8W IP65 & IK10 class having extrusion aluminium housing with polycarbonate diffuser having system lumens output of Min. 800 Lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6500K THD<10% p.f. >0.90 operating range of 140-240V inbuilt surge protection of 2 kV Life class of 25 000 Hrs. at L50B50 including driver complete with 2 Year warranty as per specification No FG-ODF/FLS2. [2- 4-19]
Supplying and erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL [2-5-5]
Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG- BKT/WB [2-7-4]
Supplying and erecting 10-12W 230V integral type LED Lamp suitable for B-22 / E-27 base. [2-8-11]
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF [2-10-21]
Supplying and fixing anchor type fastener fan hook with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. [2-11-2]
Supplying, erecting and marking SPMCB 6A to 32A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-3]
Supplying, erecting and marking DPMCB 6 A to 32 A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-7]
Supplying and erecting single pole and neutral distribution board (SPNDB) with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs with door 1.2mm thickness surface / flush mounted IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB [5-4-8]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying, Erecting and Commissioning of 2 pole RCCB 16/25A electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW- RCCB/RCCB ( single pole DB incomer) [5-6-1]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. ( fixing of name board flood light brackrts and stands) [6-1-19]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL (Street Light Cable Bollard Light cable LED flood cable etc.) [7-1-4]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL ( from Main DB to Security Cabin) [7-1-5]
Supplying and erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE [7-6-2]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. DWC for Street light cable = 315 mtr Cable from main DB to Security Cabin = 98mtr [7-6- 9]
Supplying and erecting FRP box of size 150mm x 125mm x 100 mm 2.7 mm thick complete on pole/wall as per specification No. CB-SB Gate Light = 8 Nos Flood Light = 10 Nos Name Board Flood and st lt on porch = 4 Nos [7-8-8]
Providing and erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F top 70 mm A/F on provided foundation as per specification no. OH- PL/OPL [8-2-12]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Excavating hard murum / stone metal road by chiselling for preparing pit for poles stay or earth plates or for laying cables pipes & clearing the site by removing debris & making the site as required complete. for erection of bollards & flood foundation boxes ( 0.3 x 0.3 x 0.3 ) = 0.027 Cum x 20 Nos = 0.54 Cum [16-1-6]
Making cement concrete foundation in 1 3 6 cement concrete (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). (0.3 x 0.3 x 0.3 ) = 0.027 Cum x 20 Nos (10 Nos for LED flood Light + 10 Nos for Bollards)= 0.54 Cum [16-3-7]
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel concrete excavation and fixing provided nut bolts with the help of template duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). [16-3-9]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 module duly erected. [1-6-27]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. [1-6-29]
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens min. efficacy of 110 lumen/W CRI>80 CCT upto 6500K Beam Angle of 120 deg. THD<10% p.f. >0.95 operating range of 140-260V in built surge protection of 2.5 kV Life class of 50 000 Hrs. at L70B50 including driver IP66 IK09 rated on provided PVC Block / wooden board with 3 years warranty. [2-1-15]
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens min. efficacy of 100 lumen/W CRI>80 CCT upto 6000K Beam Angle of 110 deg. Ripple<5% THD<10% p.f. >0.95 operating range of 200-270V surge protection of 2 kV Life class of 50 000 Hrs. at L70B50 including driver with end caps on provided PVC Block / wooden board with 3 years warranty. [2-1-18]
Supplying and erecting 20 SWG G.I sheet metal cawl rectangular / round shaped with 25 x 25x 3 (mm) angle iron frame metal mesh to avoid birds entry with necessary material suitable for exhaust fan of 300 mm as per specification no FG-FAS/MSC ( for SMOKE window to cover ) [2-11-17]
Supplying, installing, testing and commissioning of ADD ON B For Full Collective control system add as below. For Lift travelling above First floor & up to Sixth floor [3-6-1]
Supplying, erecting and marking DPMCB 6 A to 32 A B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-7]
Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. [5-4-13]
Supplying, fixing, and commissioning 2 pole RCBO 6/10/16/20/25A with overcurrent rated short- circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO [5-6-9]
Supplying, fixing, and commissioning 4 pole RCBO 6/10/16/20/25A with overcurrent rated short- circuit breaking capacity (10 kA) and earth leakage protection with 30/100/300 mA sensitivity and short circuit and earth leakage trip indications per specification no SW-RCCB/RCBO [5-6-12]
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes panel boards etc. including cutting bending drilling welding riveting treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. ( Lift Supply Box- as per design shown on plan) [6-1-1]
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010 [6-1- 14]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. [6-1-19]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 2.5 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( Control Box to Lift Shaft wiring & Lift cabin light supply) [7- 2-14]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 6 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( Lift Supply box to Lift Drive / Control Panel) [7-2-32]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 10 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU ( from main DB to lift Supply fabricated box) [7-2-33]
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials testing & recording the results as per specification no. EA- EP [9-1-2]
Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. [9-2-4]
SITC of Electric Traction Passenger Lift with · Rated capacity - 13 Passenger/884Kg · Floors - Parking + G+2 floor (4 Stops/4 Landings) · Travel - 13.2 mtrs. · Location of Lift Machine - MR/MRL · Rated speed - 1.0mps VS · Car/Landing door clear opening of 900/1000 mm wide x 2000 mm high · Clear Car size of 1100 mm wide x 2000 mm deep x 2250mm high · Lift shaft available having clear size of 1800 mm wide x 2700 mm deep 2000 mm Pit depth 6000 mm Overhead. · Doors type - COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick with hairline finish with frame made from MS girders bracing of adequate size with minimum safety factor of 5 with Toe Guard Apron with necessary false ceiling with adequate LED lights blower/fan
ADD ON A- 3 For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel] this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators extension of guide rails shaft wiring with trunking travelling cables main hoisting ropes/belts & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. [3-6-1]
Supplying, erecting and marking FPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-12]
Supplying, erecting and marking TPMCB 6A to 32A with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB [5-3-10]
Supplying and erecting four pole ON LOAD change over switch 415V 32A IN ENCLOSURE having staggered termination phase barrier shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit rotary handle operational current category AC23A complying to IS/IEC 60947-3 Part-1/3 [5-1-1]
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP [12-3-1]
Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. [12-4-8]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-9]
Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No WG-MA/BW [1-3-3]
Supplying and erecting Water level controller 230/415 V A.C. Four way under ground & Over head tank operation only. [12-4-15]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG- MA/BW [1-3-1]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 4 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-31]
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws wall fasteners supports nut bolts etc. complete with compliance to IS 720 2010 [6-1- 14]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. For Pump panel Frame to install all accesories 40 X 40 X 5 mm angle 1.2mtr x 2 nos = 2.4mtr 1.0mtr x 2 nos = 2.0mtr 0.3mtr x 4 nos = 1.2mtr .................................................................................. 5.6mtr x 3 kg/m = 16.80 kg [6-1-19]
Supplying and erecting automatic control panel for 3 Phase 415 volt A.C Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP S.P.P. Combined ammeter/ voltmeter phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing phase reversal phase imbalance etc . [12-4-17]
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP. [16-5-6]
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete. [16-6-21]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. For earthing water pump panel frame 17mtr x 0.596 kg/m = 10.13 kg [9-2-3]
Supplying and erecting PVC trunking (PVC casing- n-capping) of size 25 mm with accessories on wall/ceiling as per specification No WG-MA/CON. [1-2-7]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG- MA/BW [1-3-1]
Supplying, installing, testing and commissioning of heat detector with combination ROR and Fixed Temp. complete as per specification no. FF- FAS/HD [13-9-1]
Supplying, installing, testing and commissioning of optical type smoke detector on suitable back box with necessary connections complete as per specification no. FF-FAS/SD [13-9-3]
Supplying, installing, testing and commissioning of manual call point (Pill box) with break glass push button (resettable type) in metal enclosure complete as per specification no. FF-FAAS/MCP [13-9-6]
Supplying, installing, testing and commissioning of hooters having high (100dB 1m) and low (94dB 1m) volume setting group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete as per specification no. FF-FAAS/HTR [13-9-8]
Supplying, installing, testing and commissioning of remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI [13- 9-9]
Supplying, installing, testing and commissioning of FRLS XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU ( NOTE- 2% Rise in FRLS Cable) [13-9-10]
Supplying, installing, testing and commissioning of 6 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories 16x2 Character LCD Display provision for zone wise contact and beep sound alarm suitable to operate on 120-220 V AC 0 - 49 Deg C 93 ± 2 Percentage RH (non- condensing) at 32 ± 2 Deg C complete as per specification no. FF- FAAS/FACP Basic Cost 17839/- + ((25% per zone (4459.75) x 4 Additional zones)) =17839+ 17839 = 35678 + 5% (1783.90) = 37461.90 for 6 zone FACP Panel [13-9-14]
Supplying and erecting iron work sheet metal work consisting of CRCA sheets various sections of iron plates chequered plates rods bars MS pipes etc. for panel board or any other purpose with bending cutting drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. Bracket for supporting stand of Pipes 40 x 40 x 5 mm angle (3 Kg/m) 0.15mtr x 2 Nos 0.17mtr x 1nos Total = 0.47 Kg/ bracket x 34 Stands = 15.98 Kg [6-1-19]
Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. Note Reduce Rate 10% Basic Rate 7519/- New Rate = 7519/- - 10%(751.90)= 6767.10/- + 5%(other than Dist HQ- 338.36/-) = 7105.46 [3-11-77]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3 core 4 sq. mm. copper conductor complete erected with glands & lugs on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU [7-2-15]
Supplying and erecting G.I. pipe ‘C’ class ERW 75/80 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-5]
Supplying and erecting G.I. pipe ‘C’ class ERW 100 mm dia with necessary fittings complete as per specification no. FF-PP [13-6-6]
Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-19]
Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating as per specification no. FF- VL/BFV [13-7-20]
Supplying and erecting 100 mm dia cast iron double flange NRV complete with PN16 pressure rating as per specification no. FF-VL/NRV [13-7-24]
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV [13-7- 35]
Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV [13-8-2]
Supplying and erecting 63mm dia reinforced rubber lined (R.R.L.) hose pipe 15m in length fitted with necessary accessories complete as per specification no. FF-FFA/RRL [13-8-4]
Supplying and erecting gun metal branch pipe of 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specification no. FF-FFA/NZ [13-8-7]
Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC [13-8- 10]
Supplying and erecting 20/25mm dia gun metal air release cock with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV [13-8-13]
Supplying and erecting 100 mm dia. pressure gauge 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve erected with provided G.I. pipe elbow etc. complete as per specification no. FF-FFA/PG [13-8-14]
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve hose pipe hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8 x6 ) and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5) [13-8-20]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). Foundation for Booster Pump 1 mtr x 0.5 mtr x 0.3 mtr = 0.15 Cum [16-3-5]
Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. [13-15-1]
Supplying, erecting, testing and commissioning of stand mounted/handheld type wired microphone having 2 mV/Pa sensitivity impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in - 10 deg C to +55 deg C with min. 7 metre shielded cable and 3 Pin Professional XLR Connector stereo jack complete as per specification no. FF-PA/MIC [13-11-3]
Supplying, erecting, testing and commissioning of 1.5 sq. mm speaker wire complete. [13-11-10]
Supplying, erecting, testing and commissioning of 15 to 30 Watts sound column or ceiling mounted complete as per specification no. FF-PA/SOC [13- 11-2]
Supplying, erecting, testing and commissioning of 120 W amplifier suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR [13-11-1]
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with PVC accessories on wall / ceiling as per specification No WG-MA/CON [1-2-3]
Supplying, erecting, testing and commissioning of rust free microphone floor stand of chrome plating/powder coating or S.S. material 500 mm to 1500 mm height and sturdy mechanism ensuring trouble free movement complete. [13-11- 4]
Supplying, installing, testing and commissioning of booster fire pump [BP] suitable for water discharge of 450 LPM at 35 m head driven by electric motor 415 volts 3 phase 50 Hz AC supply of 5.5 kW or of suitable kW capacity for manual/automatic operation and consisting of following (a) Horizontal/vertical type single/multi stage centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade) mechanical seal conforming to IS 1520. (b) Squirrel cage induction motor TEFC synchronous speed 3000 RPM suitable for operation with IP 55 protection for enclosure horizontal foot mounted type with Class-'F' insulation conforming to IS-325. (c) M.S. fabricated common base plate coupling coupling guard foundation bolts etc. as required. (d) Erected on provided suitable size cement concrete foundation duly plastered with anti vibration pads with perfect aligning proper levelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-MFP/BP [13-3-1]
Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 70 sq. mm. copper conductor complete erected with provided lugs laid in provided control panel/distribution boards / pipe as per specification no. CB-LT/CU [7- 2-4]
Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete and recording the results Specification no. EA-MOBI [9-1-5]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. 2 (L + W) = 2 (74.61 + 23.85) = 2 (98.46) = 196.92 mtr 25 X 3 mm G.I. Patti = 0.596 kg/m 196.92 mtr x 0.596 Kg/m = 117.36 Kg [9-2-3]
Supplying and erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete. [9- 3-1]
diesel generating set with alternator of 100 kVA output continuous rating 3 Phase 415 V 50c/s 0.8 p. f. A.C supply a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours along with standard accessories self-excited self-regulated screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 % with performance class G2 and maximum fuel consumption 17.4 Ltr/hr 75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters switchgears indicators connected with suitable wires/cables the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet sound absorbing material to restrict sound level up to 75 dB at 1.0 m provided with first filling of oil diesel not less than 230 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG [11- 1-12]
microprocessor based AMF panel suitable for diesel generating set of above 82.5 kVA up to 100 kVA capacity Three phase 415 Volts 50Hz A.C. with all standard features safeties etc as per specification no. GEN-AMF. NOTE Basic Rate = 127053/- - 10% (12705.30)=114347.70 for other than Dist. Headqtr 114347.70 + 5% (5717.39) =120065.09 [11-2-10]
Providing and erecting 4 Pole MCCB 415V 200A rated short-circuit breaking capacity 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides with insulation withstand capacity 800V no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB [5-5-2]
Supplying and erecting SS enclosure for MCCB suitable for 125A to 200A MCCB. [5-11-18]
Supplying and erecting terminal spreaders suitable for 4 pole above 100A up to 250A MCCB (Set of 8) [5-11-7]
Supplying, erecting & terminating FR XLPE insulated galvanised steel formed wire armoured (strip) cable 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB- LT/AL [7-1-18]
Supplying and laying (including excavation) of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface to required depth complete. [7-6-10]
Supplying, installing, testing and commissioning of FR XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU ( FOR SENSOR CABLE) [13-9-10]
Making cement concrete foundation in 1 2 4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps). 4 mtr x 1.5 mtr x 1 mtr = 6 Cum [16-3-5]
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. [16-1-5]
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials testing & recording the results as per specification no. EA-EP [9-1-1]
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP [9-1-4]
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. [9-2-3]
Supplying and erecting HMS PVC conduit FRLS grade 20 mm dia. with PVC accessories on wall / ceiling as per specification No WG-MA/CON [1-2-3]
Supplying and erecting PVC trunking (PVC casing- n-capping) of size 32 mm with accessories on wall/ceiling as per specification No WG-MA/CON [1-2-8]
Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG- MA/BW [1-3-1]
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No WG-MA/BW [1-3-1]
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. [1-6-1]
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter duly erected on provided plate and box with wiring connections complete. [1-6-10]
Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 module duly erected. [1-6-30]
Supplying and erecting 10m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. [1-8-23]
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC [1- 10-1]
Supplying, fixing, and configuring 24 ports POE switch in provided rack as per specification No. WG-NWC/ENS [1-11-3]
Supplying, installing & testing UTP connector (RJ- 45) as per specification No. WG-NAS/UTPC. [1-12-1]
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK [1-12-17]
Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following features Image Sensor minimum 1/2.8 Progressive Scan CMOS Video Resolution minimum 2592 x 1520 Video Compression H.264 H.265 or higher at least Three individually configurable stream Frame rate minimum 25 fps at all resolutions WDR minimum 120 dB Wide Dynamic Range ONVIF profile conformant minimum IR distance 50m Lens Type 2.8/4/6 mm Lens fixed focal Field of View 2.8 mm horizontal FOV 107° vertical FOV 57° diagonal FOV 129° 4 mm horizontal FOV 86° vertical FOV 47° diagonal FOV 102° 6 mm horizontal FOV 55° vertical FOV 29° diagonal FOV 65° Lux sensitivity - minimum 0.2 Lux at color minimum 0.05 Lux at Black & White 0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan 350° Tilt 72° Rotate 350°. Power Supply Support 12VDC & PoE IP67 IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum
Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR interface transfer rate 6 GB/S maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+ Cameras supported up to 64 Cache (MB) 256 Load/Unload Cycle -3000000 Work Load Rating per Year 180TB MTBF 1000000 Hrs. HTTPS. RoHS UL CE certified duly erected in position in provided NVR12 Month Fully Compressive Warranty) (NON CSR) [30-1-30]
Supplying installing testing & commissioning of 32/40 Ch. Network Video Recorder (NVR) suitable connect Min. 32 IP Cameras up to 5 Megapixel Resolution with HDMI/VGA outputs provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080. Support H.265 or higher H.264 MJPEG Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks ANR Technology 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB minimum 02 USB port Alarm I/O 16/4 RJ-45 10/100/ 1000 Mbps self-adaptive Ethernet interface ONVIF conformance Multiple network monitoring Web viewer . support protocol TCP/IP DHCP DNS DDNS NTP SADP SMTP NFS iSCSI UPnP™ HTTPS. RoHS UL CE FCC certified. duly erected in provided U Rack with wiring connections tagging and programming etc. complete. ( NON CSR) [30-1-30]
Supplying & erecting 43 professional LED display with 1920*1080 (Full HD) Display suitable for 16/32 channel NVR and following features Brightness minimum 500 Cd/m2 Contrast Ratio minimum 1000 1 Viewing angle 178/178 deg. Response time maximum 8 ms Inputs HDMI VGA BNC USB Audio In Built-in speakers maximum 10 W Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete (NON CSR) [30-1-31]
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid