Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹32.8 L+₹90,733 (2.84%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹33.0 L+₹1.0 L (3.28%)Rejected-AOC 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | L3 | Rejected-AOC L3 |
Tender Value
₹32.0 L
EMD Value
₹32,000
Closing Date
9 Oct 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
36/EDCB/2023-24
2023_MVVNL_845852_1
36/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹3,540
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹32,000
17 May 2024
4 Oct 2023
10 Oct 2023
4 Oct 2023
9 Oct 2023
4 Oct 2023
4 Oct 2023 - 9 Oct 2023
Amount
The work of safe carriage of the following material from store center Nawada to work site under the jurisdiction of EDD-IV (Ujhani), Budaun Approx. distance upto 0-60 Km. Including safe loading and unloading.
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
11/0.4 KV 400 KVA T/F
PCC Pole 8.5 Mtr. Long
11 KV MS T-Off Channel
Top Channel (125x65x2240 mm)
S/S Base Angle (75x75x6x2028mm) with Bolt & Nut
11 KV Disc Insulator Composite 45 KN (T&C Type)
11 KV Pin Insulator Composite
11 KV TPMO
L.T. Cable 1x240 Sqmm
L.T. Cable 1x400 Sqmm
L.T. XLPE Cable 3.5x150 Sqmm
ABC Cable (3x95+1x35+1x16) sqmm
Stay Complete
Earthing Complete
ACSR Weasal Conductor
Construction of 250/400 KVA T/F plinth 1.5x1.5x2 Mtr. for mounting T/F including foundation work (below ground 0.5 M), Brick work, RCC slab of 4” thickness and plastering in 1:6 ratio with 02 Nos channel pieces of 1.5 mtr long of size 100x50x6 mm compete in all respect as per RESSPO Norms.
Fencing work suitable for 250/400 KVA T/Fs plinth of size 15’x12’x8’ and angles of suitable size should be grouted on all 04 corners and 01 side for gate. Gate will also be constructed and Jali of fencing of size 1” of Burfi Shape. Including cost of all material compete in all respect as per RESSPO Norms.
Earthing of Neutral/Body of each T/F separately of T/Fs. All the material for earthing work shall be provided by the contractor as per Norms.
Boring process (approx. depth 60 ft.) and lowering GI Pipe 1.5” dia with connecting and welding of GI Strip to 250 KVA T/F (Neutral).
Lowering of 20 mm dia Earth Rod 60 ft. and connecting, welding of G.I. Strip to 250 KVA T/F Body.
Dismentaling of following Transformer as per norms complete in all respect
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
Construction/Erection of Double Pole (except pole) Suitable for following T/Fs including fitting of all accessories (All necessary clamps, Nut & Bolts etc. shall be provided by the contractor for execution of work as per details given in S.No. 14 as per RESSPO Norms).
11/0.4 KV 100 KVA T/F
11/0.4 KV 63 KVA T/F
Mounting of following T/F,s as per norms complete in all respect -
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
11/0.4 KV 400 KVA T/F
Laying, Stringing, Sagging & Jumpring of Following Conductor complete in all respect as per RESSPO Norms.
L.T. Cable 1x240 Sqmm
L.T. Cable 1x400 Sqmm
L.T. XLPE Cable 3.5x150 Sqmm
ABC Cable (3x95+1x35+1x16) sqmm
ACSR Weasal Conductor
Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms. (All the grouting material shall be provided by the contract for execution of work).
The work of driving the earthing electrode and making connections with GI wire.
Installation, Fixing & Fabrication of 11 KV fuse set (Including Cost of Fuse set) Installed on midway of 11 KV double pole structure with mention material specification (MS Channel 100x50x2028mm), Iron Strip (50x5x305 mm) & Fuse wire of required capacity etc. shall be provided by the contractor for execution of work as per RESSPO Norms.
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms. (Danger Board shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms).
Erraction/Fixing of Tailess Unit (400 A) (Tailess Unit shall be provided by the contractor as per details given in S.No. 14 as per RESSPO Norms). complete in all respect as per
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Holding Clamps for S/s with Bolt & Nuts
Holding Clamps for LT T-OFF
Holding Clamps for Cost of MS Channel (100x50x2028mm) for fuse set
Stone Pad
Danger Board
Al. Lugs for 150 KV Sqmm Cable
Al. Lugs for 240 KV Sqmm Cable
Al. Lugs for 400 KV Sqmm Cable
LT Tailess Unit (400A)
Safe back carriage of Following item (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-60 Km including loading & unloading.
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
M/S HINA ELECTRICALS
M/s Shubham Traders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .