Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-AOC LOWEST TENDERER | |
| 2 | L2₹26.5 L+₹4.0 L (18.0%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
2 Nov 2022, 6:00 pmClosed
P Bangar Raju,IDSE
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDITION / ALTERNATION AND SPECIAL REPAIRS TO BLDG. NO P-474 AT SMQ AND PROVN OF STAFF WASHROOM AT NKG SCHOOL AND PROVN OF THREE PHASE ELECTRIC POWER SUPPLY FOR 20 KVA UPS OF KASTURI AT INS SHIVAJI LONAVLA
2022_MES_557541_1
GE/LONAVLA/8101/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
6 documents required · 6 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹55,000
Yes
13 Dec 2022
13 Oct 2022
4 Nov 2022
13 Oct 2022
2 Nov 2022
20 Oct 2022
13 Oct 2022 - 19 Oct 2022
Amount
Taking down cement or cement lime plaster, any description on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water etc.
M&L for rendering 10 mm thick cement plaster in CM 1:6 on brick work/concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified.
M&L for rendering 20mm thick cement plaster in CM 1:4 (12mm as 1st coat and 8mm in finishing coat using water proofing compound on brick/ stone surfaces finished fair and even without using extra cement etc complete all as specified and directed.Note : Water proofing compound and will be measured and paid separately.
M&L for rendering 5 mm thick cement plaster in CM 1:3 on ceiling or concrete surfaces finished even and smooth (without using extra lime or cement) complete all as specified.
M&L for doubbing out with 1:1.5:3 cement concrete slurry for ceiling and chajjas any similar work including scaffolding and avg depth of doub out 25mm complete all as specified and directed.
M&L for preparation of new plastered surface of ceiling and applying three coat of white wash over 3mm thick wall care putty complete all as specified and as directed.
M&L for preparation of new plastered surface of wall and applying Two coat of oil bound distemper over the alkali resistance priming paint primer over 3mm thick wall care putty complete all as specified and as directed.
Preparing new plastered external surface of wall and applying 2 Coats of Acrylic elastomeric exterior waterproof coating (Dr. Fixit Raincoat or of equivalent make mentioned in list of manufacturers herein after) with extra coat on rain lashed walls, dead walls, projections & Parapet wall top on primed surface with Efflorescence resistant penetrating primer (Dr. Fixit Primeseal or of equivalent make mentioned in list of manufacturers herein after) diluted with 50% water, over 3mm wall care putty, Work shall be executed by engaging the approved applicator of the manufacturer and as approved by GE.
M&L for complete removal of existing treatment of old painted wall surfaces and praparing and applying two coat of oil bound distemper over alkali resistance primimg paint primer over 3.00 mm thick white cement based wall care putty smooth finish etc of approved make & shade on walls and other places complete all as specified and as directed.
Complete removal of existing treatment of external surface of wall including removing fungus /algae dirt, oil, grease and loose particles by wire brush,cleaning, washing and removing dust, . Cracks less than 2 mm, should be cleaned free of dust with a vaccum cleaner and apply Dr. Fixit Primeseal (Efflorescence resistant penetrating primer.) let it dry. Then pour Dr. Fixit Raincoat into these cracks and wait for it to dry Apply the first coat of Dr. Fixit Raincoat without any dilution at the rate of 2 sqm per litre and allow it to dry before taking up the second and third coats, the rate of application being the same, Drying time between coats will be 6 to 8 hrs, A total thickness of 1 to 1.2 mm must be achieved when Dr. Fixit Raincoat is dry and including necessary scaffoldings etc , complete all as specified and directed Note:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
M&L for complete removal of existing treatment of old painted ceiling surfaces and praparing and applying three coat ofwhite wash over 3.00 mm thick white cement based wall care putty smooth finish etc of approved make & shade on walls and other places complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
Dismantling stone slabs and tiles of any descritpion or thickness in floors/skirting laid bedded in any mortar complete all as specified and directed.
M&L machine cut granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade
M&L Non Skid ceramic coloured tiles 7 to 8 mm thick (desined pattren) (square/ rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L Glazed ceramic coloured tiles in vertical surfaces (desined pattern)350 x 250x 7 to 8 mm/ 450 x 350 x 7 to 8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L glazed ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) size 600x600mm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
Glazed ceramic coloured tiles in vertical surfaces/skirting 8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match
Screed bed or bedding layer of mortar 15mm thick in CM (1:4) for laying floor tiles
M&L for rendering 10mm thick in CM 1:3 as in backing coat of as in skirting and glazed tiles/ facial tiles in walls complete all as specified and directed.
Taking down steel/aluminium windows/ventilator of any type any size complete with all fittings
S&F machine cut and machine polished, green marble, 18-20mm thick in single piece as in cooking platform bedded, window cill etc jointed and pointed with neat grey cement slurry and pointed with coloured or white cement with pigment to match over and including backing coat of rendering 10 mm thick in CM 1:4 all as specified and directed.
Machine cut cudappa stone slab 18-20mm thick over cement screed/backing coat15 mm thick in CM (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in single piece for cill, soffit and jambs of windows & ventilators including rubbing and polishing complete all as specified and directed
S&F Powder coated aluminium three track, three shutter (equal width) type window miniumum 15 micron anodised with frame made of aluminium sections of size 91.80 x 31.75 x 1.2mm and shutters made out of aluminium sections 39.4 x17.7 x 1.2mm without sash bars including necessary jointing cleats, glazing clips, rubber packing, anodised snap beadings, screws aluminium fittings lockings arragngements etc including 4.00mm thick sheet glass for glazed shutters and stainless steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40mm for wire gauge shutter all as specified and as directed, before.
S&F powder coated aluminium ventilator partly fixed and partly louvered type without sash bar section as per minimum 15 micross anodised including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete.
Dismantiling and removing sunken slab filling of brick bats/cinder/light weight concrete including plastering on sunken floor/sides of floor slab/tiles of toilets in all the floors including all the water and sanitary fixtures and removing all rubbish/debris outside MoD land as per instruction complete all as specified and directed.
The suken floor RCC slab including sides to the full extent of sunken portion in upper floor shall be prepared and plastered with 15 mm thick cement plaster in CM 1:3 with water proofing compound as per manufacturer's instructions and finished even and smooth without using extra cement. When the plaster is cured and dried up, apply a uniform coat of blown grade bitumen 85/25 @ 1.2 kg/Sqm confirming to IS 702 over a coat of primer @ 0.70 Kg.Sqm over plastered surface complete all as specified and as directed. Note :- Integral water proofing compound shall be measured and paid separately as "Supply only".
Water proofing treatment to Sunken floor slabe complete as specified bellow and as directed. (a) Provide and lay 3mm thick APP modified torch applied prefabricated five layer water proofing membrane weight not less than 3.60 Kg/Sqm. (b) Apply a uniform coat of blown grade bitumen 85/25 @ 1.2 Kg/Sqm confirming to IS 702 of the surface area.
PCC lean concrete 1:5:10 type E2 laid in layers of not more than 100 mm thick tamping etc complete all as specified and directed by Engineer-in-Charge.
50mm thick PCC 1:2:4 type B0 as padding concrete over lean concrete.
Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris to a distance exc. 1500m but n.exc. 2000m etc complete all as specified and directed.
M/L for rendering 15mm thick in cm 1:4 on concrete roof and chajja surface to get a uniform level surface for laying of membrane treatment
M/L for PCC 1: 2 : 4 type B-1 (using 20mm graded agg) for PCC padding on RCC roof surface finished even and smoother using extra cement all as specified and directed by Engr-in-Charge.
M/L for applying oil based bituminous primer @ 0.10 Kg/Sqm providing and laying 4mm thick. APP modified water proofing membrane weighing not less than 4kg/sqm re-inforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 140 degree centigrade longitudinal tensile strength not less than 650 N/Sqm, tearing strength of 180N and with thermal insulation with the mineral / graved finish on upper side and laying with torches application and with 10 cm minimum lap in both direction length wise and width wise all as specified and directed by Engr-in-charge.
M&L for making the grooves 25mm wide and 50mm deep to 'V' section in existing walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves, inserting chajja of PPGI sheet and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius, built in cm 1:6 including demolition.
Dismantling of water tanks exc 250& n exc 500 ltr capacity and removing to store complete all as specified and directed.
Dismantling of water tanks exc 500 & n exc 1000 ltr capacity and removing to store complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 ltrs capacity hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 2000 ltrs capacity hoisted and fixed in position including 25mm dia float ball brass valve and flynut complete, screwed for iron pipe or brass ferrule and fixed all as specified
Taking down 15mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified.
Taking down 20mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified.
Taking down 25mm dia bore GI steel tubing and connection including cleaning and making good dismantaled surface complete all as specified.
Dismantling /taking down PVC/Cast iron soil/waste pipes 100mm/75mm bore including all fitting like bends etc.
S&F CPVC pipes, SDR 11, 25mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified.
S&F CPVC pipes, SDR 11, 20mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified.
25 mm dia gate /sluce valave fixed to pipe complete all as specified and directed.
20 mm dia gate /sluce valave fixed to pipe complete all as specified and directed.
S&F Vitreous china wash down water closet (Padestal pattern) pan white including bolts and flush pipe, pedestal pan and trap including connections to drain (or outgoing pipe) and flushing pipe etc including seat cover closed type complete fixed in repairs.
S&F Vitreous china white flat back of size 580x450mm wash basins, vitreous china (flat back or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe fixed in repairs.
S&F 10 litre PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets.
S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed.
S&F Flush pipe of polyethylene of low or high density or PVC, 32mm dia for low level cistern.
S&F PVC connection low density polythene pipe 15mm dia, 450mm long, heavy duty with PTMT nuts.
S&F waste fittings 32mm dia, brass, chromium plated for glazedware sinks, basins, etc, with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed.,
S&F in repairs Bib taps, fancy type, chromium plated with crutch sc-rewed down, screwed for iron pipe or for brass ferrule and fixed 15 mm bore complete all as specified and as directed.
S&F in repairs Pillar taps, fancy type, chromium plated, screwed down, high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed 15 mm bore complete all as specified and as directed.
S&F in repairs Stop valves cast copper alloy, chromium plated fancy type long shank and cup screwed down, screwed for iron/CPVC pipes high pressure, with crutch or butterfly handle, screwed both ends suitable for 15mm pipes.
S&F in repairs Angle cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch or but-terfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs toilet paper holder of stainless steel of size 10.5cm X 9cm fixed to walls with chromium plated (CP) brass screws complete all as specified and as directed.
S&F in repair soap dish Cat No BA -25 of Prayag polymers Pvt Ltd or equivalent complete all as specified and directed.
S&F in repairs hand shower (Health Faucet), chromium plated with 8mm dia, 1.00m long flexible tube with wall hook all as specified and as directed. Cat No:- ALD - 573 of Jaquar or equivalent model Manufactured by Esess/ Marc.
S&F in repairs acrylic cabinet mirror of size 450mm X600mm fixed with wooden plugs with cromium plated screw and cup washers, complete all as specified and directed, Make shall be of M/s Commander , M/s Jasmine or equivalent.
S&F 20mm dia towel rail chromium plated 60cm long including bracket fixed with stainless screws complete all as specified.
S&F in repairs brass chromium plated shower rose with or without swivel joints 75mm size, including fixing to steel pipe or union complete all as specified and as directed.
S&F PVC (SWR) pipes of dia 110mm bore double socketed in any length with rubber ring joints fixed to walls.
S&F PVC (SWR) pipe of 75mm bore in double socketed in any length with rubber ring joints fixed to walls.
S&F PVC (SWR) Nahani /Floor trap, 75 mm dia of out let, plain with grating including jointing to waste pipe with solvent and cement concrete type B1 (1:2:4) & including removing old trap complete all as specified and as directed.
S&F PVC (SWR) bends of 75mm bore in radius.
S&F PVC (SWR) bends of 110mm bore in radius.
M&L for PVC Bottle trap having miniumum water seal of 25mm. (Miniumum weight 32mm-260gms/40mm-270gms) of 32mm dia.
S&F PVC (SWR) branch piece double Y equal or unequal of 75mm bore in radius.
S&F PVC (SWR) branch piece double Y equal or unequal of 110mm bore in radius.
S&F PVC (SWR) cowl of 75mm bore in radius.
S&F PVC (SWR) cowl of 100mm bore in radius.
S&F Harrison curtain rails, anodised aluminium with fixing brackets, stops, rollers etc fixed in repair incl brakets complete all as specified and directed.
S&F stainles steel sink with drainage board , 1 mm thick sheet of steel grade AISI 304 for kitchen or laboratory, with plug, waste pipe, washers and wastes including bedding in cement morter to dwarf wall or including fixing CI cantilever bracket, connecting union to pipe etc., overall size 915 x 460 mm with bowl size 410 mm x 330 mm x 160 mm etc complete all as specified and directed. Make : Nirali, Bule star ISI marked.
S&F in repairs stainless steel kitchen plate rack of size 90cm X120cm X 1mm thick (18 gauge)conforming to the sample kept in the office of the AGE B/R , complete all as specified and directed.
Demolition of RCC in any description and any position complete all as specified and directed.
Removal of demolished material/ debries from site exc 5km & n.exc 10km as per direction of Engr -in charge complete all as specified and directed.
M&L for chajja repairs with 1:2:4 concrete for dubbing and 15 mm thick plaster with water proofing compound including dismantling loose plaster/ rcc and scaffolding and necessary formwork etc compete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description having width/girth exceeding 10cm and apply two coat of synthetic enamel paint complete all as specified and as directed.
Surface excavation in Hard/dense soil n. exc. 30cm deep and averaging 15cm deep and getting out complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil
M&L for Cement concrete in foundations, filling and mass-concrete Type D2 1:4:8 (40 mm graded aggre-gate)
M&L For Brick work with Sub class "B" bricks,straight or curved on plan not excceding 6m mean raidus built in CM 1:4.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in hard/dense soil.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point
Hardcore of broken stone or boulders of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface
M&L for 75 mm thick cement concrete type B-1, 1:3:6 (20mm graded stone aggregate) as in sub base flooring of pathway complete all as specifed and directed
M&L for 25mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) in subbase for floor tiles complete all as specified and directed.
Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate mixed with water proofing compound @ 3% by weight of cement and applying evenly a coat of blown type bitumen at the rate of 1.5 kg/sqm and blinding with clean dry sand @ 0.05 cum /sqm
M&L for RCC (Nominal Mix) type B0 1:2:4 (12.5 mm graded aggregate ) for lintel band ,floor/roof beam supported on walls, beams and lintel above 1.5 m clear span complete all as specified
Formwork to sides and soffits of lintel band, floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
M&L for RCC (Nominal Mix) type B1 1:2:4 (20 mm graded aggregate ) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in the shelves and the like
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping)
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips on slab, MH cover etc. complete all as specified and directed by Engineer-in-charge.
All as per item above but bars of 98 mm dia
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- (a) Apply one coat of bituminous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reniforcement weighing not less than 4.00 Kg/Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
Supply only integral water proofing compound.
M&L for Rendering 5 mm thick in CM1:3 faces of brick work or concrete surfaces and to be finished even and smooth(without using extra lime or cement) for ceilings,
M&L for Preparing newely plastered surface and applying 3 coats of ww on ceiling
Preparing newly plastered surfaces of walls & applying two coats of 100% premium antifugal acrylic base exterior weather proof paint having VOC less than 50gm /lit and UV resistance , dirt resistance paint of required shade with silicon additives @1.43 lit/10sqm over a coat of exterior primer applied @.90 ltr/10 sqm on external surfaces of wall all as specified and directed .
S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
S&F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F 100 mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified.
S&F Aluminium bow handles, cast type, anodised 125mm long.
S&F 200mm long Aluminium, anodised, barrel tower bolts of extruded section and fixed.
S&F powder coated aluminium ventilator partly fixed and partly louvered type without sash bar section as per minimum 15 micross anodised including necessary jointing, clip, rubber packing, anodised snap beading crews and 4mm thick pin headed glass etc complete.
S&F framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 Gde E-165.
S&F Angle cock, cast copper alloy, fancy type chromium plated, screwed down, high pre-ssure, with crutch screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F brass chromium plated toilet paper holder
S&F CPVC pipes, SDR 11, 20 mm outer dia conforming to IS-15778 with all fittings such as Tee, bends, elbows, unions sockets and end oieces etc to receive the fittings and fixed with solvent on walls/ceiling or laying in floors complete all as specified.
M&L for health fosset with 1mtr flexible stainless steel pipe complete all as specified and directed.
Steel water tubing medium grade 25mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion complete all as specified and directed.
S&F Steel work in tubular roof trusses as in main post, vertical member etc including special shaped washer etc, complete using ERW or induction butt welded tubes conforming to I.S 1161-1998 grade St-240 & steel painted one shop workshop before fabrication complete all as specified.
S&F Roof trusses (framed), sunshade frames, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe-410-W(Gde-E-250) all as specified and directed
Plates (plain or chequered ) channels , square cut or notched (ordinary and counter sunk) forming holes, without any attachement.
S&F wind ties for roof including securing bolts including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 etc complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
S&F for Pre- Painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L For concrete bed to 150mm dia. Pipe,PCC 1:4:8, type D2( using 40mm graded aggregate. ) Including packing under , and hancuching against the sides of pipes after they are laid and tested.
M& L for 150 mm dia. Reinforced concrete pipe, class NP -2,laid and jointed compete with collars.
Demolition of brick work/stone masonry built in cement mortar including all quoins arches, pillars all as directed.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
Dismanting of existing any type of fencing with post complete all as specified
S&F stainless steel soap tray fancy type fixed .
S&F 20mm dia towel rail brass chromium plated D type 60cm long between flanges including bracket fixed with stainless screws complete all as specified.
M&L for 75 mm thick cement concrete type B-2, 1:2:4 (20mm graded stone aggregate) as in plinth protection complete all as specifed and directed
M&L for applying two coats of oil bound distemper over the primer and 3mm thick wall care putty surface of approved make & shade on walls etc, complete all as specified and as directed.
S&F 500 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position and with float valve all as specified in ssr part-I complete all as specified and directed.
S&F gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 25 mm bore complete all as specified and directed.
S&F Vitreous china urinal , full stall type , white including flushing cistern , flush pipe and waste pipe and push tap etc complete all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) including unserviceable light fittings, switch board complete, switch sockets, ceiling roses, pendants, regulators, sockets, etc and removing materials from site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M & L for Point wiring with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. One light point or one fan point or bell point controlled by one switch
One 3 pin socket outlet, 5 Amp independent
One 3 pin socket outlet, 5 Amp on the same board with other switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size.
All as per item No.140 here in before but wiring with cables of size 2.5 sqmm for wiring & cables of size 2.5 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed. (Note : cutting chases & making good of disturbed surfaces shall be measured and paid separately).
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F socket out let, 2 in 1, 3 pin, 5 Amps, 240 volts complete all as specified and directed.
S & F Switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts complete all as specified and directed.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type with fuse & neon incator complete all as specified and directed.
S & F Ceiling rose, 3 way PVC insulated body complete all as specified and directed by engineer in charge.
Supply and fixing LED lights fitting Rod and Batten for 1x 18W, 220V,AC decorative type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete.Make: Bajaj(BLRB-DB 118 for Batten and BLRB 18W LED Rod,18W LED) or equivlent Philips/Havells
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. Make: Crompton or equivlent Bajaj/Philips/Havells
S/F switch bell push, flush type 5 Amp.
S&F in repairs bell, electronic type AC, 230 Volts single pole.
M&L lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings.
Supply and fix new adore LED lamp 9 Watt confirming to Cat No LHLDBWH4L8R009 of Havell's or euivalent in Philips / Bajaj
Supply and fix Inverter Bulb LED lamp 9 Watt confirming to Cat No LHLDEGEDML8009 of Havell's or euivalent in Philips / Bajaj
Labour only for taking down and fixing repairs to Ceiling Fan with Fan regulator/Exhaust Fan, any Make & any Sweep Oiling, Greasing , removing all dust with painting and Rewinding of fan by super ennameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing for serviceable condition complete all as directed by Engineer-in-Charge.
S&F in repairs fan regulator electronic step type complete all as directed by EIC at site
Supply and fixing LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.Make: Crompton or equivlent Bajaj/Philips/Havells
Taking down electric meter of any type and any make single/three phase by dismantling of all electrical connection checked the meter ,and Refixed same Nos of meter on wooden board in metal box of suitable size in same Nos of qtr after repair works completed
S&F in replacemen MCB DB SPN 8 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
S&F in repairs MCB SPN 40 to 63 AMP, 240 Volts 10KA 'C' curve , Complete all as specified and directed.
S&F in repairs MCB SP 5 To 32 AMP, single pole 240 Volts 10KA 'C' curve, Complete all as specified and directed.
Taking down sub main wiring of any size from the ceiling, walls etc and incl making good to disturb surface of wall and match with the existing surface.
M&L for sub main wiring drawing through PVC casing and capping with four runs of single core 6 sq mm and two runs of 6.0 sq mm as earth wire of stranded copper conductor PVC insulated and unsheathed cable of 1100 volts grade all as directed.Note:- Two run of 6 sqmm wire and One run of 6 sqmm wire and One run of PVC casing caping will be measured as one running meter.
S&F in replacement Triple pole and neutral (8 Way) Double door, (VTPN) suitable for and including MCCB 4 pole, 160 amps, 16 KA as incoming (compact) Earth and neutral bus bar of capacity upto 200 amp 8 ways,IP 43 protection , shrouded neutral bar & pan assembly with flexible connecting link in the wall with suitable nut and bolt including matching the existing surface all as specified and directed , Make Havells (DHDLVDOBGSFE08)HSN CODE 8537 or equivalent indoasian/Standered.
M&L for earthling complete with galvanized GI earth plate electrode of size 600x600x6.00 mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of volts, nuts, check nut and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate as shown in electrical plate No 3 of SSR part1991,20 mm dia watering pipe medium grade 1.50 mtr long GI protection pipe light grade 15 mm dia from earth pit to main board (NOTE:- maximum length of GI protection pipe with each earth shall not be less than 7.5 mtrs) including necessary pit with cover , including testing on complition.
M & L for cutting/making hole for fixing of ser item No 15 and making good disturbed surface with existing surface all as specified and directed by Engr-in-charge.
S&F in replacemen MCB DB SPN 4 ways double door with 240 Volt, 200 amps rated bus bar with all accessories flush in the wall including matching the existing surface all as specified and directed
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x1.5 sq. mm + 1x1.5 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 1.5 sqmm wire and One run of 1 sqmm wire and One run of PVC casing caping will be measured as one running meter.
S & F Switch socket combination, 5 in 1, 5/15 Amps, 240 volts, flush type complete all as specified and directed.
M&L for sub main wiring drawing through PVC casing and capping with Wiring alongwith earth wire size 2x16 sq. mm + 1x16 sq. mm earth wire of FRLS is PVC insulated copper conductor, single core cable in surface/recessed as required .Note:- Two run of 16 sqmm wire and One run of 16 sqmm wire and One run of PVC casing caping will be measured as one running meter.
VIJAYA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .