Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 CrAccepted-AOC | ₹4.4 Cr Quoted ₹4.6 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹4.7 Cr+₹8.9 L (1.93%)Rejected-AOC | ₹4.7 Cr+₹8.9 L (1.93%) | L2 | Rejected-AOC Rejected |
Tender Value
₹4.4 Cr
EMD Value
₹2.3 L
Closing Date
8 Feb 2024, 3:00 pmClosed
Superintending Engineer PWD
Office of the Superintending Engineer PWD Buildings Construction and Maintenance Circle Chepauk Chennai 5
Construction of Additional Building in Government Hospital at Thirukalukundram in Chengalpattu District.
2024_PWD_418211_1
TNPWD/48 BCM 03/2023-24
Open Tender
Civil Works
Lump-sum
300 days
Chengalpattu
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹2.3 L
24 Mar 2024
5 Feb 2024
8 Feb 2024
5 Feb 2024
8 Feb 2024
5 Feb 2024
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Upto 2m depth
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling M-sand in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Cement Concrete 1:5:10 (One Cement, Five sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Supplying and filling of gravel by lorry in basement filling including conveyance loading and unloading charges and all other incidential charges filling laying watering and consolidation etc., complete as directed by the Dept., Officers with standard specification.
Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
Foundation & Basement
In Ground floor
In First Floor
In Second Floor
In Third floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
For foundation & basement
Brick work in Cement Mortar 1:5 (One cement & Five sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
For foundation & basement
Brick work in Cement Mortar 1:6 (One cement & Six sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
In Ground floor
In First floor
In Second floor
In Third floor
Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
In Ground floor
In First Floor
In Second floor
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
Providing, mixing, laying polymer based water proofing treatment for the Sunken Toilet / Lift well / OHT Rcc wall by applying cement based, flexible, waterproofing compound confirming to IS:2645, to a thickness of 1mm of the prepared surface of the roof slab / floor slab as per specifications mentioned above providing cement mortar 1:3, waterproofing cover plaster to a thickness of 12mm over the membrane coating with admixture of approved make. Rate quoted is inclusive of preparation of surface, which includes cleaning of surface polymer mortar curing, labour, tools and equipment, etc. Rate inclusive of grouting with cement and sand required for the treatment, the cost and labour charges for fixing 25mm dia pressure pipes 15kg/cm2 to a length of 45cm for drip pipes, etc. complete.
Brick jelly Lime Concrete of 1:2:5 (One Lime,Two Sand and Five Brick ielly ) with 40 mm hand broken brick ielly for Sunken portions including dewatering wherever necessary and laid in layers of not more than 15cm thick, well rammed, consolidated and curing etc. complete complying with standard specification.
For First Floor
Paving the floor with best approved quality Flamed Steel Grey Granite Slab 1200mm x 600mm, 16mm to 18mm Thick laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Flooring with Self design Joint free rectified Ceramic Tiles of size 305 x 305 x 8mm laid over 20mm thick cement mortar 1:3 (Onecement and Tree sand) base mortar over the existing slab / floorincluding cutting the tiles to the required size with special cutterwherever necessary, laying in positionand and pointing with whitecement mixed with colouring pigment at the rate of 0.3 kg. / sq.m.etc., complete complying with standard specification. (The makeand brand of the tiles should be Johnson / Kajaria / Somany / Nitco/ RAK or Equivalent which has to be got approved by executiveEngineer before use on works)
Dadooing walls with Joint free rectified Colour designed digital print ceramic tiles, with borders, with size of 300mm x 600mm x 10mm and above setin Cement Mortar 1:2 (One Cement and Two sand) 20mm thick andpointing the joints with white cement mixed with colouring pigmentsat the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by thedepartmental officers. (The make and brand of the tiles should belike Johnson / Kajaria / Somany / Nitco / RAK or Equivalent whichhas to be got approved by Executive Engineer before use on works)
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Providing granolithic floor finish of the 40mm thickness with plain cement concrete 1:2:4 (One Cement, Two sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
Providing and Fixing of PVC Trims (Corner beeding) at the outer corner profiles of the tiles including cost of material, labour and handling etc. as directed by departmental engineers at site of work and as per standard specification.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (waterproof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly,etc.,complete complying with standard specifications and as directed by the Departmental Officers.The rates are inclusive of hire charges for grinding machine with wheel, cost of sand paper (water proof abrasive sheet), cost of putty blade, labour charges for grinding the joints and sand papering, two coats of putty, scrapping the putty area to level the surface smooth, etc.,complete. The putty should be got approved by the Executive Engineer before
Plastering and finishing the exposed surface of all RCC items of work with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc.,complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Supplying and fixing in position of Teak wood door shutter using spl quality teak wood planks of 40 mm thick panelled doors with required raw materials, Brass hinges, Brass tower bolt, ornamental Brass handles, Door stopper, Door closer,Brass aldrops and bush with suitable locking arrangements etc. The rate should be inclusive of cost of materials, labour charges for wrought and put up the doors with kadasal charges and transporting charges etc complete complying with standard specification and as directed by the Departmental officers.
Providing Stainless Steel Salem Stainless Steel Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc., complete complying with standard specification and as directed by the Departmental officers.
Supplying and fixing in position of flush shutter with teak wood vener for doors of 35 mm thick block board core with of applied shade and hot pressed bonded with liquid phenol formaldluide resin with internal lifting with TW as per IS 2201/ part I /1991 The rates inludes the labour charges for fixing the shutter to the frames and for fixing furniture fiitings.The rate include the cost of furniture fittings etc complete
Single leaf
Double leaf
Providing of 35mm thick factory made pre-laminated ABS (Acrolynitrile Butadiene Styrene) Door Shutter moulded in different designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x 32mm, reinforced by 32 x 32mm -2 Nos., for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides. Hardware made out of steel coated butterfly hinges -3 Nos., for each shutter and ISI make SS round lock complete for finished item of work, complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on work
Supplying and fixing of PVC Sliding Door with Roller
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mmx58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work
Supplying and fixing of M.S. grill of approved design for open courtyard, grill, grill work to doors and window openings etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including cutting the members, welding, grinding, one coat of priming coat using best approved quality red oxide primer, dismantling of walls / concrete if necessary, fixing and finishing the dismantled portion to original condition etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc.complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Supplying and fixing fine polished cuddapah slab of 38 / 40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.80mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings,such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the departmental officers. The design pattern, water proof plywood,laminate sheet and other materials should be got approved from the Executive Engineer before use on work.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg/sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3 metre pipe length, etc., complete complying with standard specification.
160 mm dia
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 6313 Part I to IV in stages to suit the progress of work consist as per the detailed specification as below. (Measurements taken for the plinth area for the purpose of payment) including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing, etc,complete and as directed by the departmental officers. (The chemical should be got approved by Executive Engineer before use on work).
Stage-1: Spraying anti-termite chemical solution for the foundation before laying concrete, in bottom and sides of foundation.Stage-2:Spraying anti-termite chemical solution to the grade beam level, spraying has to done for the grade beam, brick masonry contact with the back fill earth. Stage-3: Spraying anti-termite chemical solution on the sand for the flooring before laying the flooring concrete. This treatment has to be carried out on the sand filling by making holes with crow bar to a depth of 60cms and at 60cms intervals on both direction and at junction of wall and flooring thoroughout.Stage-4: Spraying anti-termite chemical solution alround building outside by making holes through bar before laying plinth protection and the holes to be closed after the treatment
Supplying and erecting in position of 500 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Manufacturing, supplying and fixing in positon of RCC Jally of 5cm thick in cement concrete 1:2:4 using 20mm machine crushed stone jelly (excluding cost of reinforcement steel) including cost of mould, finishing, curing, lifting, fixing in position etc., complete complying with standard specification and as directed
Supplying and fixing PPGL Sheet Roof Purlin 40x40x3.6mm Square Tube tied with welding the truss rate including the cost of materials,scafolding charges,one coat of primer and two coat synthetic enamel anticorrosive paint etc.,complete and complying with standard specification.
Supplying and fixing PPGL sheet roofing with 1.60mm thick PPGL sheets of fully corrugated of approved quality by drilling holes (and not by punching) with necessary ‘J’ / ‘U’ bolts and nuts of 8mm dia of suitable length and providing one set of bitumen washers of 25mm dia and 1.60mm thick for each bolt including protruding portion of bolts in roof shall be covered with bitumen compound etc., complete complying with standard specification and as directed.
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
25 mm dia G.M. Gate Valve
32mm dia G.M. Gate Valve
40 mm dia G.M. Gate Valve
50 mm dia G.M. Gate Valve
Supplying and fixing 7.5 HP / 3 Phase, 9 Stage sub mergible pump of approved make and quality with Starter ISI mark with necessary accssories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accssories
Supplying and fixing in position 15mm dia following taps (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works)
Long body tap
Stop Cock
Swan Neck Tap
Supplying and fixing in position 15mm dia twoway bibcock (heavy duty) with Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600x450x5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting
Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works)
Nahani Trap of size 100 x 75mm
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
75mm dia
110mm dia
160mm dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
PVC Elbow
110mm dia
75mm dia
PVC Elbow with Door
110mm dia
75mm dia
PVC Tee
110mm dia
75mm dia
PVC Tee with Single Door
110mm dia
75mm dia
110mm dia
75mm dia
PVC "Y" with Single Door
110mm dia
75mm dia
PVC bend
110mm dia
75mm dia
PVC Reducer
110 mm x 75 mm
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works)
110 mm dia
75 mm dia
50 mm dia
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, SS clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. Internal Water Supply - Above Ground Level
20 mm dia
25 mm dia
32 mm dia
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, SS clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. External Water Supply - Above Ground Level
40 mm dia
50 mm dia
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, SS clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. External Water Supply - Below Ground Level
50 mm dia
32 mm dia
Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements
UPVC Elbow
50 mm dia
40 mm dia
32mm dia
25 mm dia
20 mm dia
UPVC Tee
50 mm dia
40 mm dia
32mm dia
25 mm dia
20 mm dia
UPVC Reducer
50x40mm dia
40x32mm dia
32x25mm dia
25 x 20 mm dia
UPVC Reducer Elbow
50x40mm dia
40x32mm dia
32x25mm dia
25 x 20 mm dia
20 x 15 mm dia
UPVC Reducer Tee
50x40mm dia
40x32mm dia
32x25mm dia
25 x 20 mm dia
UPVC Hex Nipple
50 mm dia
40 mm dia
32mm dia
25 mm dia
UPVC Union
50 mm dia
40 mm dia
32mm dia
25 mm dia
UPVC Coupler
50 mm dia
40 mm dia
32mm dia
25 mm dia
Construction of Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9" thick brick work in cement mortar 1:5 using II class chamber burnt bricks of size 9" x 43/8" x 23/4" filling the size of foundation with excavated earth, plastering with cm 1:3 20mm thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and fifnishing neatly etc., complete.
Supplying and fixing in position of Steel fibre reinforced cement concrete (SFRC)manhole / inspection chamber cover slab with following frame sizes including necessary labour charges for fixing the frame in position over the cement mortar base and finishing the joints etc. complete as directed.
600x600mm cover slab
750x750mm cover slab
Supplying and fixing of PVC mould CI Steps of approved quality including dismantling masonry wherever necessary and redoing the da maged portion to original condition
DIN / BS Standard Outlet Points with from loading, inner connecting and brass body. Single press inlet with two stage process first stage for patient usage and second stage in parking mode, covered by plastic cover duly colour indicated with specific gas name and non inter-changeable for other gases. The cost of materials inclduing transport, etc., complete, as per standard specification and as directed by the Departmental Officers
Medical Gas Copper Pipeline arrangement to hang on the wall of socket type connection installation of seamless cleaned and degreased non arsenical phosphorous gas copper pipe line with saddles complete with brazing work including all copper fitting (tee, elbow, reducer, coupling). The copper pipelines should be tested suitable for a steam of working pressure of 17.34 kg. / cm2 (17 bar) and confirm to BS 864 Standard with specially made for brazed socket type connection. The medical gas copper pipeline should be tested as per standard and commissioning after painting as per International Code No. IS 2379/1963 Table-V. The pipelines installed at the various wings and floors etc., complete as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
10mm OD 0.90mm thick copper pipe
15mm OD 0.90mm Thick Copper Pipe
22mm OD 0.90mm Thick Copper Pipe
Brass Isolation Valve suitable for the copper pipe and should be of non lubricated 90 degree turn lever ball valve of reputed make, conneced in line with medical gas pipe line system by using suitable size brass valve adopter union, ferrule, nipple, rubber "O' ring, tapion lap and etc. All pipe line regulators shall be capable of controlling pipe line pressure and must compatible with the requirements specified in IS 12827-1989. All valves should be pneumatically tested for twice the working pressure for the gas line as per IS Code 12827 / 1989 & ISO 7396 / 1987 Sepecification.
15mm Isolation Valve
22mm Isolation Valve
Oxygen manifold arrangements of 2 banks x 5 cylinder Nos wing with semi automatic control panel which includes contact gauge 2 Nos., outlet pressure gauge, brass heavy duty IO x regulator 2 Nos. with suitable adopter, flexible SS Hose. Mainfold shall be of a construction and of a designs and material suitable for the service pressure in accordance with IS 1282- 1989. Emergency alarms with illuminating display for low / high pipeline pressure and malfunctioning of system.1) Mainfold top frame with provision for connecting 5 cylinders on right bank and 5 cylinders on left bank with high pressure interconnecting copper tubing, silver brazing, non return valve, fasteners and cylinder spport middle angle frame for claping 2 x 5 cylinders and related fasteners. The O2 manifold should with stand a pressure of 140 kg. / CM2. The installation is commissioned after testing as per standards and painted as per International Code and as directed by the Departmental Officers as per IS Code 12827 / 1989 & ISO 7396 / 1987 Specification.
Flow Meter made up of Brass with Humidifier Bottle Flow Meter should be back pressure compressed and should be accurate gas flow measurement with control range 0-13 litres per minute. It should meet strict permission and dumbling standard. The meter body should be made of brass materials. The humidifier bottle should be made of unbreakable polycorbonate material and auto cleavable at 134 degree centigrate. The rate includes flow meter and its accessories (silicon tube with mask). The cost of materials including transport, etc., complete as per standard specification and as directed by the Departmental Officer and as per IS 12827 / 1989 and ISO 7396 / 1987 Specification.
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
75mm thick
Supplying and fixing in position best quality approved make Stainless Steel Sink of size of 600 x 600 x 200mm including cost of 32mm dia CP waste coupling, 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakages etc., complete complying with standard specifications excluding CI brackets. [The sink and specials should be got approved by the Executive Engineer before use on works]
Plain Cement Concrete 1:2:4 (one cement, two M-sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
Supplying, fixing of cylindrical vertical notational polythene water storage tank of 2000 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the dept., Officers.
Drilling of bore well in sedimentary or Alluival Soil strated by first taking a pilot bore of 150mm ( 6") dia nd then enlarged to the required dia by direct or Rotar mud circulation method using contractor power rotory ( VI z ) Tools labour for drilling and water transportations of machince from one place to another place of half to drilling site and piont ot point in various palces as directed by the engineer in charge.150mm dia bore well
Up to 60m Depth
From 60m to 90m Depth
Reaming from 140/150mm pilot bore to 300mm dia bore as directed by the TWAD size bore as directed by the TWAD Board officers upto 60m Depth ending from ground level..
Up to 60m Depth
From 60m to 90m Depth
'Supplying and delivery of unplasticised palin PVC casing pipe of the following diameter in 3m leght with screened and socket ends and lengthing guides for every 15m length of pipes as per IS 7818/1992 and assended from time to time to suit bore well upto 80m depth (CS) for delivery at site of work with ISI making including loading unloading ant transportation insurance etc complete.
150 mm PVC plain casing pipe
150mm PVC plain casing ribbed screen pipe
Labour charges for inserting the 150mm dia PVC casing pipe assembly ( With slots or without slotted ) with drilled holes including jointing the pipe etc complete and supplying the pebbles and packing the annular spaces with pebbles of size and quality as approved by the Engineer in charge
150mm PVC plain and ribbed screen pipe
Charges for developing the bore well with air compressor of capacity 300cfm / 150 PSI for a minimum 8 hous until clear water is obtained including transportation charges for air compressor and as directed by the Engineer in charges and conduting yeild test with bore well by ari ligting pump measured by V Notch method using 300 cfm /150 PSI air compressor as approved by the Engineer in charge.
Supplying and fixing 2HP/3Phase sub mersible pump of approved make and quality with ISI mark with necessary accessories and fixed with delivery pipe errected in the borewell with necessary clamp etc., with following additional accessories. 1No of 3 phase star delta starter 63AMPS of approved quality and make with ISI mark , 1No of 3 phase 63AMPS main switch of approved quality and make with ISI mark , 1 No of priventor of approved quality and make with ISI mark , 1 No of panel board of required size with indicator fuse unit voltmeter with necessary provisions to accomodate the starter and mini starter etc. 1 No of capacitor with board as per standards of TNEB.
Supplying and fixing the HDPE pipe for the following size approved quality including connecting copper wire @ equal distance etc., complete complying as directed by the departmental officers
HDPE pipe of 32mm dia.
Supplying and fixing the PVC end cap of 160mm dia. At the end of PVC casing pipe etc., complete complying with standard specification. The bore cap should be got approved by the Executive Engineer before use on works.
Supplying and fixing of 4.00 sq.mm PVC insulated copper 3 core flate type copper wire etc., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing Nylon Rope for Bore -well etc., complete.
GST at 18%
KEERTHINATHAN
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .