Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr Quoted ₹1.5 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.5 Cr+₹3.2 L (2.10%)Rejected-Finance | ₹1.5 Cr+₹3.2 L (2.10%) | L2 | Rejected-Finance REJECTED BEING NOT LOWEST |
| 3 | L3₹1.6 Cr+₹11.5 L (7.70%)Rejected-Finance SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | ₹1.6 Cr+₹11.5 L (7.70%) | L3 | Rejected-Finance REJECTED BEING NOT LOWEST |
| 4 | L4₹1.7 Cr+₹18.4 L (12.3%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹1.7 Cr+₹18.4 L (12.3%) | L4 | Rejected-Finance REJECTED BEING NOT LOWEST |
| 5 | L5₹1.7 Cr+₹22.7 L (15.1%)Rejected-Finance NOT SPECIFIED | ₹1.7 Cr+₹22.7 L (15.1%) | L5 | Rejected-Finance REJECTED BEING NOT LOWEST |
| Sl No | Description | Qty | Unit | United Sales Corporation L5 | NATIONAL ENGINEERING CORPORATION L7 | Star Electrical L2 | AGRAWAL ASSOCIATES L6 | Maruti Abhiyantriki L1 | UNITED ENGINEERING CORPORATION L4 | Rama Electricals L3 | SHAILENDRA B TULSANI L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F Steel tubular swaged poles complete with cast iron plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-55 (11 mtr long) including one coat of red oxide primer and two coats of aluminium paint and making 30 cm wide strips (total -05 Nos) with yellow and black paint alternately on external surface above column/PCC benching including numbering with black paint and painting with bitumenou paint internally and externally for portion embedded in PCC complete all as specified and directed. | 2 | Each | 20,000 ₹40,000 | 30,000 ₹60,000 | 24,000 ₹48,000 | 25,000 ₹50,000 | 19,500 ₹39,000 Lowest | 27,500 ₹55,000 | 26,500 ₹53,000 | 29,970 ₹59,940 |
| 2.00 | S & F Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement consisting of MS chanel HT post type insulator copper alloy, high pressure assembly drop out fuses operating rod of 20 mm dia GI pipe (medium grade) for operating from 1.2 m above GL complete including drop out fuses conforming to IS-9921 Part-I to V (1982 to 1985) of 1972 rated voltage 11 KV and for current rating 200 Amp all as specified | 1 | Each | 30,000 ₹30,000 | 22,000 ₹22,000 | 15,000 ₹15,000 | 18,750 ₹18,750 | 16,000 ₹16,000 | 17,500 ₹17,500 | 14,000 ₹14,000 Lowest | 24,300 ₹24,300 |
| 3.00 | S&F in repairs cable end joint kit 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed by Engr-in-Charge. | 2 | Each | 3,500 ₹7,000 Lowest | 4,900 ₹9,800 | 4,500 ₹9,000 | 6,000 ₹12,000 | 3,500 ₹7,000 Lowest | 9,000 ₹18,000 | 4,000 ₹8,000 | 14,004 ₹28,008 |
| 4.00 | S & F Lighting arrestor (set of three) HT metal oxide surge arrestor polymetic type complete with all fittings rated voltage 12 KV continuous operating voltage. 11 KV, normal discharge current 10 KA max residual voltage at 8/20 impalse 75 KV etc complete all specified confirming to IEC-600994-2001. | 1 | Set of 3 | 5,500 ₹5,500 | 15,000 ₹15,000 | 3,600 ₹3,600 Lowest | 12,750 ₹12,750 | 4,000 ₹4,000 | 4,500 ₹4,500 | 4,000 ₹4,000 | 6,300 ₹6,300 |
| 5.00 | Supply, installing, commissioning and testing of in-door type, HT 11 KV, 3 phase 50 cycles, oil immersed, naturally air cooled, core type. LT, 433 volts, step down, copper wound 400 KVA capacity transformer in accordance with vector group Dyn ll with neutral brought out on LV side as per IS 1180, Part - I, 2014 including all fittings and consisting of the following acessories complete all as specified and directed including tak9ing down of old panel:-
a) Rating plate and terminal marking plate.
b) Two earthing terminlas for body earthing and two additional for neutral brought out on a bushing.
c) Lifting lugs.
d) Drain valve with plug or cover plate.
e) Dehydrating breather.
f) Oil level indicator with minimum and maximum Marking.
g) Cooling Radiator.
h) Thermometer pocket.
j) Conservator
k) Oil filling hole with cover.
l) Air release device with conservators.
m) Filter valves
n) Rollers as per manufacturer's design.
o) Thermometer 100mm dial type with metal guard having maximum temperature indication with resetting device.
p) Winding temperature indicator. | 1 | Each | 13,75,000 ₹13,75,000 | 18,00,000 ₹18,00,000 | 8,50,000 ₹8,50,000 | 21,00,000 ₹21,00,000 | 1,05,000 ₹1,05,000 Lowest | 23,62,877 ₹23,62,877 | 16,41,380 ₹16,41,380 | 18,00,000 ₹18,00,000 |
| 5.01q) First fill of transformer oil r) Explosion vent. s) HV & LV Cable terminating box. t) LV neutral bushing brought outside for direct earthing. (u) Tapping switch handle with indicator and locking arrangement. (v) Jacking lugs/pads. (w) Cover lifters. (x) Inspection cover. y) Any other fittings as recommended by the manufacturer and as directed by the GE Note: (i) Modification in existing PCC paltform including along with plastering is deemed to be inclusive of the quoted rate. (ii) The Transformer shall be got inspected and tested at site by the SEI/rep nominated by the Accepting Officer and the records of the testing shall be signed by the rep of A.O., GE, Engr-in-Charge and the contractor. (iii) All the arrangements and testing equipments etc, for testing as per note above shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor's quoted rates. | |||||||||||
| 6.00 | M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e M.S. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of aluminium paint (1st quality ) as reqd complete as specified. | 5 | Per Qtl | 9,500 ₹47,500 | 10,000 ₹50,000 | 8,100 ₹40,500 | 11,000 ₹55,000 | 10,000 ₹50,000 | 10,000 ₹50,000 | 8,000 ₹40,000 Lowest | 11,700 ₹58,500 |
| 7.00 | Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor type, free floor standing / wall mounting factory fabricated made out of 3.0 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom frame with stand made out of MS Angle 50mm X 50mm X 6 mm thick and of height 600 mm. A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof, | 1 | Each | 5,25,000 ₹5,25,000 | 4,60,000 ₹4,60,000 | 4,50,000 ₹4,50,000 Lowest | 4,50,000 ₹4,50,000 Lowest | 6,21,000 ₹6,21,000 | 5,40,000 ₹5,40,000 | 4,83,210 ₹4,83,210 | 4,94,136 ₹4,94,136 |
| 7.01complete as specified and consisting the following switchgears and accessories, inluding CT, internal wiring, connectots, cable terminal etc all as directed including taking down of old panel (Main Panel Board at New Sub Stn): INCOMING Manually Draw out type ACB 800 Amps 4 pole, 415 Volt With and including Micro processor Based Release protection, Over load protection, earth fault protection, short circuit protection & Metering Display - 1 No OUTGOING MCCB TP 415 Volt 400 Amps 36 kA - 01 Nos MCCB TP 415 Volt 200 Amps 36 kA - 02 Nos MCCB TP 415 Volt 125 Amps 36 kA - 02 Nos MCCB TP 415 Volt 160 Amps 36 kA - 03 Nos MCCB TP 415 Volt 100 Amps 25 kA - 01 Nos MCCB TPN 415 Volt 40 Amps 16 kA -01 Nos STREET LIGHT TIMER CIRCUIT Digital Street light timer switch - 1 No Contactor M L 2 - 1 No Auto Manual Selector Sitch - 1 No INDICATION RYB Phase Indicator -01 Set Digital VAFPF Meter -01 Nos | |||||||||||
| 7.02Note: 1. All CTs, shall be as per the rating of the switchgear and of Cast resin type. 2. PCC foundation of depth 0.45 Mtr below GL and 0.60 mtr above GL for mounting of Panel is deemed to be included in the quoted rate for the job. 3. Danger Notice plate shall be provided on either facia of the panel. 4. Layout diagram of panel shall be got approved by GE and shall be manufactured from make mentioned in Particular Specification. | |||||||||||
Tender Value
₹1.4 Cr
EMD Value
₹2.1 L
Closing Date
26 May 2025, 6:00 pmClosed
COL SP SINGH
CWE AF LOHEGAON, PUNE-411032
UPGRADATION OF E/M NETWORK IN DOMESTIC AREA AT AF STN PUNE
2025_MES_705871_1
81931/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF LOHEGAON
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE AF LOHEGAON
₹2.1 L
Yes
21 Aug 2025
29 Apr 2025
2 Jun 2025
29 Apr 2025
26 May 2025
21 May 2025
Amount
S & F Steel tubular swaged poles complete with cast iron plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-55 (11 mtr long) including one coat of red oxide primer and two coats of aluminium paint and making 30 cm wide strips (total -05 Nos) with yellow and black paint alternately on external surface above column/PCC benching including numbering with black paint and painting with bitumenou paint internally and externally for portion embedded in PCC complete all as specified and directed.
S & F Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement consisting of MS chanel HT post type insulator copper alloy, high pressure assembly drop out fuses operating rod of 20 mm dia GI pipe (medium grade) for operating from 1.2 m above GL complete including drop out fuses conforming to IS-9921 Part-I to V (1982 to 1985) of 1972 rated voltage 11 KV and for current rating 200 Amp all as specified
S&F in repairs cable end joint kit 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed by Engr-in-Charge.
S & F Lighting arrestor (set of three) HT metal oxide surge arrestor polymetic type complete with all fittings rated voltage 12 KV continuous operating voltage. 11 KV, normal discharge current 10 KA max residual voltage at 8/20 impalse 75 KV etc complete all specified confirming to IEC-600994-2001.
Supply, installing, commissioning and testing of in-door type, HT 11 KV, 3 phase 50 cycles, oil immersed, naturally air cooled, core type. LT, 433 volts, step down, copper wound 400 KVA capacity transformer in accordance with vector group Dyn ll with neutral brought out on LV side as per IS 1180, Part - I, 2014 including all fittings and consisting of the following acessories complete all as specified and directed including tak9ing down of old panel:- a) Rating plate and terminal marking plate. b) Two earthing terminlas for body earthing and two additional for neutral brought out on a bushing. c) Lifting lugs. d) Drain valve with plug or cover plate. e) Dehydrating breather. f) Oil level indicator with minimum and maximum Marking. g) Cooling Radiator. h) Thermometer pocket. j) Conservator k) Oil filling hole with cover. l) Air release device with conservators. m) Filter valves n) Rollers as per manufacturer's design. o) Thermometer 100mm dial type with metal guard having maximum temperature indication with resetting device. p) Winding temperature indicator.
q) First fill of transformer oil r) Explosion vent. s) HV & LV Cable terminating box. t) LV neutral bushing brought outside for direct earthing. (u) Tapping switch handle with indicator and locking arrangement. (v) Jacking lugs/pads. (w) Cover lifters. (x) Inspection cover. y) Any other fittings as recommended by the manufacturer and as directed by the GE Note: (i) Modification in existing PCC paltform including along with plastering is deemed to be inclusive of the quoted rate. (ii) The Transformer shall be got inspected and tested at site by the SEI/rep nominated by the Accepting Officer and the records of the testing shall be signed by the rep of A.O., GE, Engr-in-Charge and the contractor. (iii) All the arrangements and testing equipments etc, for testing as per note above shall be provided by the contractor and cost of the same shall be deemed to be included in the contractor's quoted rates.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections i.e M.S. channel or angle sections etc. including new nuts, bolts, washers as reqd dia/length in size, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive one primer coat of red oxide, one under coat and one finishing coat of aluminium paint (1st quality ) as reqd complete as specified.
Supply install, test and commissioning LT Feeder Pillar / Panel board cubical type outdoor type, free floor standing / wall mounting factory fabricated made out of 3.0 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing ACB, MCCB, MCB and TPN Aluminum bus bars of rating not less 1.5 times the rated cap of incomer MCCB / ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC / Epoxy insulators having provision for termination of incoming and out going cables. All extension links /interconnection shall be insulated with heat shrinkable colour coaded sleeves. The cubicle shall have a bottom frame with stand made out of MS Angle 50mm X 50mm X 6 mm thick and of height 600 mm. A detachable predrilled gland plateof thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front and back openable lockable /openable by key from both side and shall have louvers and air vent gasket for natural flow of air.3 mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof,
Note: 1. All CTs, shall be as per the rating of the switchgear and of Cast resin type. 2. PCC foundation of depth 0.45 Mtr below GL and 0.60 mtr above GL for mounting of Panel is deemed to be included in the quoted rate for the job. 3. Danger Notice plate shall be provided on either facia of the panel. 4. Layout diagram of panel shall be got approved by GE and shall be manufactured from make mentioned in Particular Specification.
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 100 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 40 Amps 16 kA - 05 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 125 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 40 Amps 16 kA - 05 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 125 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 40 Amps 16 kA - 06 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories : Incoming MCCB FP 415 Volt 200 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 125 Amps 16 kA - 01 Nos MCCB TP 415 Volt 40 Amps 16 kA - 03 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 125 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 40 Amps 16 kA - 05 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 160 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 40 Amps 16 kA - 06 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 400 Amps 36 kA - 01 Nos Outgoing MCCB TP 415 Volt 200 Amps 25 kA - 01 Nos MCCB TP 415 Volt 63 Amps 16 kA - 05 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 200 Amps 25 kA - 01 Nos Out Going MCCB TP 415 Volt 32 Amps 16 kA - 04 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 160 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 32 Amps 16 kA - 03 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 100 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 63 Amps 16 kA MCCB TP 415 Volt 40 Amps 16 kA - 06 Nos LED Type RYB Phase Indicator -01 Set
All as per Sl Item No 7 herein before but with consisting following switchgears and accessories Incoming MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos Outgoing MCCB TP 415 Volt 25 Amps 16 kA - 05 Nos LED Type RYB Phase Indicator -01 Set
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip armoured, electric power cables under ground cable(heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 sq mm complete all as specified and directed by Engr-in-Charge.
Supply and laying in trenches or fixing to wall/pole or passing through pipe XLPE insulated heavy duty underground armoured electric cable with aluminium conductor 1100 volts grade cross sectional area 300 Sqmm 3.5 core, including cable glands, lungs al as required and directed at Site.
All as per Sl Item No 21 but of size 240 Sqmm 3.5 Core.
All as per Sl Item No 21 but of size 185 Sqmm 3.5 Core.
All as per Sl Item No 21 but 120 Sqmm 3.5 Core.
All as per Sl Item No 21 but 70 Sqmm 3.5 Core.
All as per Sl Item No 21 but of size 50 Sqmm 3.5 Core.
All as per Sl Item No 21 but of size 35 Sqmm 3.5 Core.
All as per Sl Item No 21 but of size 25 Sqmm 3.5 Core.
All as per Sl Item No 21 but of size 16 Sqmm 4 Core.
All as per Sl Item No 21 but of size 10 Sqmm 4 Core.
All as per Sl Item No 21 but of size 10 Sqmm 2 Core.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for crushed stone dust sand cushioning to UG cable, provide with the layer 8 cm below cable and 15 cm above cable after laying and punning down to 10 CM thickness and testing the cable complete all as specified and directed by Engr-in-Charge. Note :- Thickness of sand after punning will be measured and paid.
M&L for Sub class ‘B’ bricks old size laid dry flat over the cable abutting each other along, length of cable equal to width of brick all as required.
M&L earthing complete with galvanised steel earth plate eletrode 60 cm x 60 cm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32 mm x 6 mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32 mm x 6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate eletrode 60 cm x 60 cm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top prjgc, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth wire 4.0 mm, by means of bolts, nuts, check buts and washers of galvanised iron and 4.00 mm earth lead protected by provision of GI medium grade pipe 25 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to DB & Poles all as specified including testing on completion complete all as specified and directed.
Supply & Fix HDGI Octagonal pole 7 Meter height having top dia 70 mm and bottom dia 135 mm and thickness 3 mm, including door opening with in built TPN connector, din rail, MCB etc Note - RCC foundation will be measured seperately under respective items
Supply only 1 mtr single arm heavy duty GI pipe bracket made of 40 NB GI Pipe with nuts & bolts, bracket all as directed suitable for item No 41 for mounting street light fitting
Supply only of suitable foundation bolt set 4 Nos 'J' type foundation bolts of dia 16 mm and 450 mm long with base plate, all for item No 41 as per manufacturer recommendation.
Supply and fixing LED street light fitting 70/72 Watt 230 V AC outdoor type with high pressure die cast aluminum housing, with toughned glass and heat resistant complete with driver, lamp bracket with impact and corrosion resistant complete with IP 65/66 protection complete. including clamp & nut bolts etc complete
Supply and fixing copper cable multistrand PVC insulated PVC seathead 1.5 Sqmm 2 core all as directed by Engr-in-charge
S & F cable route indicator of size 100 mm x 100 mm x 5 mm thick GI plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and grounting the same in ground with PCC as required for LT/HT calbe incl necessery earth work all as specified and directed.
Dismantling from insulators and taking down ACSR/Copper conductor any size from LT over head lines all as specified and directed by Engr-In-Charge
Dismantling earth wire any size from eye hooks/insulators etc from HT/LT over head lines all as specified and directed by Engr-In-Charge
Dismantling insulator any type and any size from LT over head lines all as specified and directed by Engr-In-Charge.
Dismantling, cross arms, clamps, supports made of channels or angle section etc including nuts and bolts and setting aside all as required at site or directed by Engr-in-charge.
Dismantling stay assy complete including excavation for taking out PCC block breaking of PCC block for taking out MS plate specified and directed by Engr-In-Charge
Dismantling steel tubler poles any type and any size including excavation for taking out pole, breaking of PCC block with due care all as specified and directed by Engr-In-Charge.
Supply install, test and commissioning in repairs LT wall mounted indoor Panel board factory fabricated made out of 2 mm thick CRCA sheet & suitable size to accomodate all accessories/fittings, compartmentalized in construction to accommodate incoming and outgoing MCCB, MCB and TPN copper bus bars of rating not less 1.5 times the rated cap of incomer MCCB. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The incoming as well as outgoing MCCBs shall have copper extension links of current carrying cap not less than 1.5 times the rated capacity of individual feeders. A detachable predrilled gland plateof thickness not less than 2 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front openable lockable /openable by key, The Panel shall be manucatured from CPRI approved manufacturerof makes stipulated. The cost is inclusive of disconnecting existing cables, reconnecting the cables with lugs & glands, making good of distribued PCC all as directed, including following acessories (a) Incoming MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos (b) Outgoing MCB TP 40 Amps, 230 Volts , 10 kA - 02Nos (c) Space for Fixing 02 no Thre Phase energy Meter (d) Taking down and refixing of Energ Meter from old Panel & Refixing the same in New Panel. Note : (a) All CTs PTs shall be as per the rating the switchgear and of Cast resin type. (b) PCC foundation of depth 0.45 Mtr below Gl and 0.60 mtr above GL for mounting of Panel is deemed to be included in the qouted rate for the job. (c) Danger notice plate shall be provided on either facia of the panel. (d) Layout diagram of panel shall be got approved by GE and shall be manufactured from make mentioned in Particular Specification
All as per Sl Item No 53 herein before but with consisting following switchgears and accessories (a) Incoming MCCB FP 415 Volt 63 Amps 25 kA - 01 Nos (b) Outgoing MCB TPN 40 Amps, 230 Volts , 10 kA - 04 (c) Space for Fixing 04 no Three Phase energy Meter (d) Taking down and refixing of Energ Meter from old Panel & Refixing the same in New Panel. Nos Note : (a) All CTs PTs shall be as per the rating the switchgear and of Cast resin type. (b) PCC foundation of depth 0.45 Mtr below Gl and 0.60 mtr above GL for mounting of Panel is deemed to be included in the qouted rate for the job. (c) Danger notice plate shall be provided on either facia of the panel. (d) Layout diagram of panel shall be got approved by GE and shall be manufactured from make mentioned in Particular Specification
Supply and fix GI Pipe Light grade with all connected accessories of sizes 50 mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 80 mm dia complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm dia complete all as specified and directed by Engr-in-Charge.
S & F Rigid non-metallic PVC conduit of bore 20 mm with not less than 1.8 mm wall thickness, ISI marked and fixing accessories such as saddles, pipe hooks etc. complete all as specified and as directed.
M & L for Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide including black top, sub base and WBM, well ramming in layers with watering after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
Supply and fix Hot press mounded SMC pole junction box with hinged single door (Door fixed with hinge on left side and colour Off white) size 195 x 135 x 90mm including including 2 Nos alluminium bus bar ,50 Amps ,single phase duly insulated and fixed for terminating single phase 10 sqmm alluminium UG cable etc with 01 No ,MCB SP 10 Amps,10 KA , clamps and nut bolts complete all as per manufacturer’s instructions.
M & L painting of steel tubular electric poles up to 11m with preparation old steel surface of any discription over 10 cm in width or girth with applying two coat of alluminium paint incl cross arms complete all as specified.
Supply and labour for brick work with sub class 'B' bricks, straight or curved on plan exc or curved on plan exc 6 m radius built in cement mortar 1:4 in two pole /4 pole electrical substation area complete all as specified and directed by engr-In-Charge
Materail and labour for cement plaster 15 mm thick in cemment morter 1:4 on brick work or concrete surfaces finished even and smooth.
Fixing only chain link fencing including line wires any mesh size and type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed by Engr-in-Charge
Supply only chain link MS galvanised fencing any size of type 2.10 meter high complete all as specified and directd by Engr-in - charge
Supply and fix angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, painting by applying two coat of red oxide primer, two coat of enamel paint etc., and similar work conforming to Fe-290 Gde E-165
Supply and fix Coarse aggregates (Granite, Trap or Basalt), grading l, grading 3, 50 to 20 mm size around Transformer/2 Pole structure) all as specified and directed
Material and labour for Pre-cast cement concrete block masonry with solid blocks,Type B1 1:2:4 20 mm graded aggregrate exc. 10 cm in width and setting in mortar 1:6 complete
Material and labour for broken stone of boulders hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete
M&L for cement concrete (1:4:8) type D2 in foundation filling and mass concrete using 40mm graded stone aggregate for pole/stay foundation etc
M&L for cement concrete (1:2:4) type B2 in foundation filling and mass concrete using 40mm graded stone agg for pole/stay foundation etc
M & L for shifting of transformer of capacity 250 KVA from New Sub Stn at OMQ to Proposed Switch Yard near OMQ gate inluding disconnecting of all cable connctions at New Sub Stn and connectioning the cables, testing and commissioning at Switch yard near OMQ gate and including the following itms of works: Note: (i) PCC for foundation and paltform including excavation, PCC block Mansonary , mooram filling, plastering, compaction of mooram/earth is deemed to be inclusive of the quoted rate. Foundation shall be of Size not Less than L - 2.00 Meter, W - 2.00 Meter, Height 1.5 Meter from GL and Depth 0.5 meter below GL
S&F VTPN 4 way IP 43 IK-09 with double door suitable for Provision of MCCB 63 Amps, 25 KA, 4 POLE and for housing of MCB's complete including taking down old DB's/MCB's all as directed by Engineer-in-Charge.
S&F MCB SPN 6 to 32 Amp 10 KA 240 V C Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge
S&F MCB SP 6 to 32 Amps 240 Volts, 10 KA B Curve MCB Complete all as specified and directed by Engr-in-Charge
M &L for RCC foundation for HDGI octagnal poles including excavation in post holes of depth up to 1400 mm in any kind of soil such as soft, loose, hard rock, for erection of poles, removing the excevated materials to distance not exceeding 50 meter and providing PCC 1:3:6, 100mm thick as in bed and RCC foundation as per following:- (i) PCC BED - 450 mm X 450 mm X 100 mm (ii) RCC Column including formwork and Reinforcement - 400 mm X 400 mm X 1300 mm, M20 Design, using 4 Nos 12 mm Steel Bar, binders etc all as per manufactures instructions and directed by Engr-in-Charge. Note : Minor changes if recommended by OEM shall be incorporated and cost of same is deemed to be included in quoted rate.
Star Electrical (BID ID -3305352)
Rama Electricals (BID ID -3305679)
UNITED ENGINEERING CORPORATION (BID ID -3305654)
United Sales Corporation (BID ID -3302989)
AGRAWAL ASSOCIATES (BID ID -3305407)
NATIONAL ENGINEERING CORPORATION (BID ID -3304386)
SHAILENDRA B TULSANI (BID ID -3305193)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .