Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.6 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹68.9 L+₹37,260 (0.54%)Rejected-Finance | L2 | Rejected-Finance ok | |
| 3 | L3₹77.5 L+₹8.9 L (13.0%)Rejected-Finance GROUND FLOOR THAKUR COMPLEX BASANTPUR | BASANTPUR | SHIMLA | HIMACHAL PRADESH | 171018 | L3 | Rejected-Finance ok | |
| 4 | L4₹78.1 L+₹9.5 L (13.9%)Rejected-Finance SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | L4 | Rejected-Finance ok |
Tender Value
₹74.5 L
EMD Value
₹1.5 L
Closing Date
28 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN Electrical Division No. 1 Shimla
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
CO Judicial court complex building Additional Block at Nahan Distt Sirmo H.P. SH-Providing E.I therein.
2025_PWD_124131_1
Electrical Division-I dated 22.12.2025
Open Tender
Electrical Works
Percentage
365 days
SHIMLA
As Per tender documents
11 documents required · 11 mandatory
₹2,000
₹1.5 L
26 Feb 2026
22 Dec 2025
29 Dec 2025
22 Dec 2025
28 Dec 2025
22 Dec 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.Approved make Reo havells, Anchor penta & Goldmedal Air A5.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.Approved make Reo havells, Anchor penta & Goldmedal Air A5.
Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of mm deep 6 modules(205mmx78mmx50mm on surface or in recess with suitable size phenolic laminated sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req.(For light plugs)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
3x1.5 Sq. mm
3 x 2.5 sq. mm
Supplying and fixing PVC batten/ angle holder including connections etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Supplying and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Approved make Havells,L&T , ABB, legrand ,Schneider & C&S.
Single pole
Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required.Approved make Havells,L&T , ABB, legrand ,Schneider & C&S.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).Approved make Havells,L&T , ABB, legrand ,Schneider & C&S.
12 way , Double door
8 way , Double door
6 way , Double door
Providing and installation exhaust fan of following sizes in the existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: of Approved Make Domestic type.Approved Make Orient, Havells, Goldmedal,Bajaj & atomberg.
Exhaust Fan, Light duty, (Domestic) 225/230 mm sweep
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Supply, Installation, Testing and Commissioning of following sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.85, Air delivery minimum 215 CMM, 300 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote/ BLDC electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Approved Make Atomberg(Efficio),Havells(EfficiaNeo),Orient(Hector500)&goldmedal(Maruti),Bajaj (etticia).
Ceiling Fan 1200 mm sweep
Ceiling Fan 1400 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.Approved make:bajaj,havells,Goldmedal,panasonic,Philips,Wipro,Chengi
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as below
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰ to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED)As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 25000 burning hours at 70% lumen maintenance
Description
Lumen output of the fitting
LED Batten Light (1000 lumens)
S/E of LED Batten with aluminium extrusion housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.Approved make:bajaj,havells,panasonic,Philips,Wipro,LT,Chengi
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as below
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >110 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED50000 burning hours at 70% lumen maintenance
Description
Lumen output of the fitting
LED Batten Light (2200 lumens)
S/E of LED Downlighter surface square with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.Approved make:bajaj,havells,panasonic,Philips,Wipro,LT,Chengi
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Lumen output of the fitting as below
Diffuser Polycarbonate diffuser/pmma
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >100 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰ to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED)As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED50000 burning hours at 70% lumen maintenance
Lumen output of the fitting
Square LED Down Light Surface(1500 lumens)
Square LED Down Light Surface(2000 lumens)
Square LED Down Light Surface(2400 lumens)
S/E of LED Panel with PDC body and prismatic diffuser to be mounted on Surface. The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet.Approved make:bajaj,Havells,wipro,Philips,LT,Chengi
Specification of LED fittings:
Wattage of LED fittings As per following parameter.As per following parameter.
Total lumens of the fittings. as below
Diffuser Prismatic multilayer diffuser UGR <19
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >120 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰ to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED) As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
Description
Lumen output Of fitting Rate
Square LED Panel Light (2'x2') (4320 lumens)
S/E of LED Panel with PDC body and prismatic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet.Approved make:bajaj,Havells,wipro,Philips,LT,Chengi
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as below
Diffuser Prismatic multilayer diffuser UGR <19
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >120 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰ to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED)As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2.5 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
Description
Lumen output Of fitting
LED Panel 2x2 (4320 lumnes)
S/E of LED bulk head IP 66 rated with aluminium body/PDC housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.Approved Make Philips,Havells, Bajaj , wipro Goldmedal & Panasonic as per following specification.
Specification of LED fittings:
Wattage of LED fittings As per following parameter.
Total lumens of the fittings. as below
Diffuser Polycarbonate diffuser/PMMA
Operating voltage 140 V to 270 V, AC supply or better.
Input frequency 50 Hz + 1 Hz
Power factor Minimum 0.90
Luminaire efficacy >80 lm/w
Color rendering index CRI shall be greater than 80
Working/ operating temperature 0⁰ to + 45⁰c or better
Color temperature 6000⁰K + 10%
Electronic Driver
Drive current (LED)As per OEM.
Operating voltage 140 V to 270 V AC supply or better
Type of driver Constant current output driver
THD Less than 10%
Surge Protection 2 KV minimum
Efficiency Driver >85%
Protection Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver 2 years against manufacturing defect.
Fixture Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED 50000 burning hours at 70% lumen maintenance
Description
Lumen output of the fitting
LED Bulk Head (800 lumens)
Supplying and fixing of fancy wall bracket suitable for input voltage: AC 220- 240 V, 50/60Hz, complete with all accessories, lamp holder, but excluding lamp including making connections, testing etc. as required: of Approved Make
Wall light fixture Polycarbonate body, suitable for 9 W retrofit LED lamp B22 base.
Providing and installation of following type of LED retrofit lamp B-22 holder base with polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. Make: Philips, Syska, GE, Bajaj, C&S, Panasonic or any other approved by Engineer-in-Charge.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and erection of light sub - panel (confirming to (IEC code-61439 part 1&2) of dimensions 700mm(H)*500mm(W)*200mm(D) with plus 5cm variation,made from CRCA MS sheet enclosure. Panel will be fabricated with 16-SWG CRCA sheet steel for load bearing surfaces and 16-SWG for non load bearing surfaces fully dust & vermin proof,complete with locking arrangements to hose MCCB 32 amp (4 pole) 25 KA with TMA Protection release (Ics=100% Icu) as incommer and 63 Amp Copper busbar(300 mm copper strips lenth) TPN of Electronic Grade E91 & 1 set RYB light indicator set and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc. (i) 32 A Sub Panel
Supplying and erection of light sub - panel (confirming to (IEC code-61439 part 1&2) of dimensions 700mm(H)*500mm(W)*200mm(D) with plus 5cm variation,made from CRCA MS sheet enclosure. Panel will be fabricated with 16-SWG CRCA sheet steel for load bearing surfaces and 16-SWG for non load bearing surfaces fully dust & vermin proof,complete with locking arrangements to hose MCCB 63 amp (4 pole) 25 KA with TMA Protection release (Ics=100% Icu) as incommer and 63 Amp Copper busbar(300 mm copper strips lenth) TPN of Electronic Grade E91 & 1 set RYB light indicator set and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc. (i) 63 A Sub Panel
Supplying and erection of light sub - panel (confirming to (IEC code-61439 part 1&2) of dimensions 750mm(H)*500mm(W)*200mm(D) with plus 5cm variation,made from CRCA MS sheet enclosure. Panel will be fabricated with 16-SWG CRCA sheet steel for load bearing surfaces and 16-SWG for non load bearing surfaces fully dust & vermin proof,complete with locking arrangements to hose MCCB 100 amp (4 pole) 25 KA with TMA Protection release (Ics=100% Icu) as incommer and 100 Amp Copper busbar(300 mm copper strips lenth) TPN of Electronic Grade E91 & 1 set RYB light indicator set and cable alley as required complete in all respects including the cost of switchgear . The cubical pedestal shall have cable entry box at one side,with epoxy powder coated approved paint and bonding to the existing earth etc. (i) 100 A Sub Panel
Supplying and erection of sheet metal cubical pedestal (confirming to(IEC code-61439) of dimensions 3000mm(W)*2175mm(H)*500mm(D) with plus 5cmm variation,made from 1.6mm thick M.S. Sheet duly fabricated in a segregated manner for housing of switch fuse units,by welding each compartment on five sides &front sides hinged,complete with locking arrangements including 1 No. MCCB 800 amp(4 pole) 50 KA with TMA Protection release (Ics=100% Icu),1 No. MCCB 400 amp(4 pole) 36 KA with TMA Protection release (Ics=100% Icu) as incomer for heating load,1 No. MCCB 160 amp (4 pole) 36 KA with TMA Protection release (Ics=100% Icu) as incomer for light load , 2 no.MCCB 100 amp.(4 pole) 25 KA with TMA Protection release (Ics=100% Icu) & 3 no. MCCB 63 amp (4 pole) 25 KA with TMA Protection release (Ics=100% Icu) as outgoing for heating sub panels ,6 No. MCCB 32 amp(4 pole) 25 KA with TMA Protection release (Ics=100% Icu) & 1 No. MCCB 63 amp(4 pole) 25 KA with TMA Protection release (Ics=100% Icu) as outgoing for light sub panels,Changeover switch 160 amp(4 pole) 36 KA with TMA Protection release (Ics=100% Icu) , copper busbar strips 800 amp,400 amp,160 amp ,metering module & indicating lamp set.The cubical pedestal shall have cable entry box at one or two sides,with epoxy powder coated approved paint and bonding to the existing earth etc.The same shall be erected in the 1:2:4 cement concrete platform of suitable dimensions 15 cm high from ground level and 45 cm thick.The cubical pedestal shall be 15 cm from the top of cement concrete platform.
800 Ampere LT Panel
P/F openable sheet metal shutter suitable for exhaust fan size 300mm as required complete in all respect.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. in the existing trench,complete as required. Make:- Astral Pipes, Precision Pipe or any other approved by the Engineer in Charge.
63mm Dia (OD-63MM & ID-51 MM Nominal)
120MM Dia (OD-120MM & ID-103 MM Nominal)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Approved Make Universal Cables, Havells,Grandlay & Kei.
Armoured cable 6 sq. mm (twin core)
Providing & Laying of one number aluminium conductor, PVC insulated and PVC sheathed armoured/ XLPE power cable, 1.1 KV grade of following sizes on wall surface as required.Approved Make Universal Cables, Havells,Grandlay & Kei.
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 35 sq. mm (3.5 core)
Armoured cable 50 sq. mm (3.5 core)
Armoured cable 630 sq. mm (3.5 core)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 A socket outlet
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Providing and Fixing Wall Fan 300 mm with Connections, testing & Commisiioning etc as required.Make: Havells,Orient,Bajaj or as approved by Engineer-in-Charge.
S/E of 5 Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 200mm x200mm x12mm alongwith inbuilt lockable junction box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination as per site requirement and one no. 6 Amps. Single pole MCB for each luminaire. The diameter across from the dimensions of the base and top should be minimum 130 mm and 70mm A/F (Across Face). The size of the poles and foundation bolts shall be suitable to withstand the maximum wind speed/ pressure as per IS-875. There should be no any circumferential welding on the pole. The method and material shall comply with as BSEN-10025 grade S355 or equivalent poles should be hot dipped galvanized in single dip to 65 microns min. confirming to IS 2629-1966. The material and specifications of flange plate/base plate shall be as per IS 2062. The street light poles shall be as per IS 2062. The street light poles shall be erected in the existing RCC foundation with 4 nos. special foundation bolts ‘J’ type minimum 600mm long galvanized M.S. rod of duly threaded of minimum 20mm dia in existing RCC foundation of suitable size as per the approved drawing. The material of steel foundation belts shall be confirming to grade EN-8 exposed threaded portion of foundation bolts shall be hot dipped galvanized. The octagonal pole should be of Bajaj / Transrail / Utkarsh / Valmont/ Salasarmake only. (The cost of 5 Meter long S/L octagonal poles is including with 4 nos. x M16 x 600mm long ‘J’ type bolts with nuts, carriage of pole at site & installation complete as required.
GI Octagonal Light Pole-5m Long
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil (Size 0.7mx0.7mx1.2m = 0.588 cum (13 Nos. x 0.588cum= 7.64)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) (0.7m x 0.7m x 0.10m = 0.049 cum.) (13 nos. x 0.049 = 0.637)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars 1.Vertical Bar 12mm dia =4 nos.x1.2=4.8 r.mtr. @0.89 kg per mtr. =4.27 kg 2.Horizontal Ring 8mm dia =8 nos.x2=16 [email protected] per mtr.=6.24kg Total (4.27+6.24=10.51+5% wastage=11.03 Kg. Total = 13 nos. x11.03 = 143.39Kg.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) Size 0.5x0.5x1.1 = 0.275 cum Total (13 nos. x 0.275= 3.57 cum.)
Centering and shuttering including strutting, propping etc. and removal of form for all heights :
Foundations, footings, bases of columns, etc. for mass concrete Size 4 (0.5 x 1.2) = 2.4 sq. mtr. 13 x 2.4 = 31.2 Sq. Mtr.
Supply, Fabrication and erection of GI pipe (medium class) bracket with suitable size of nipple for mounting the existing street light fitting with the following specifications.
The bracket shall be made by Medium Class GI pipe of 2” dia with an angle of inclination of as 105 degree to vertical
The 2” dia G.I. pipe shall be connected to a 4” dia G.I. pipe (45 cms) as required & canopy with top end closed with 14 G MS sheet to avoid entry of rain water in the pole.
The 2” dia pipe shall be welded at a distance of 2” from the close end with 4” dia GI pipe
The bracket shall be slipped over the top section of octagonal pole & fixed with 2 Nos. ½” dia GI nuts & bolts.
A triangular 14 G MS sheet pieces of 2” shall be welded between two pipes.
Single arm bracket made out of 2” dia. G.I. pipe 3’ overhang.
S/E of LED Street Light IP 66 rated with aluminium body/PDC housing.The job includes carriage, erection, making connections testing and commissioning of the fittings.The Specification of the Fittings is as under :-
Wattage of LED fittings :-As per following parameter.
Total lumens of the LED fittings
Body of fitting :-Pressure dia cast aluminium body with Extruded Aluminium heat sink
Input frequency :-50 Hz + 1 Hz
Operating voltage- 140 V to 270 V, AC supply or better.
Power factor :-Minimum 0.90
Luminaire efficacy :->110 lm/w
Color rendering index:-CRI shall be greater than 70
Working/ operating temperature :-00 to + 450c or better
Color temperature :-6000ºK to 65000K
Electronic Driver :-
Drive current (LED) :-As per OEM.
Operating voltage :-140 V to 270 V AC supply or better
Type of driver :-Constant current output driver
THD :-Less than 10%
Surge Protection :-(10 KV minimum External) ( 4 KV Internal)
Efficiency Driver:->85%
Protection:-Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver :-2 years against manufacturing defect.
Fixture :-Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model:-Havells/Bajaj/Panasonic with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED:-50000 burning hours at 70% lumen maintenance
LED Street Light 45/50 Watt
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.Approved Makes: D-Link, Molex, Commscope
1 run of cable
2 run of cable
3 run of cable
Providing and fixing RJ45 Information Outlet wall socket with SMB, in/c making necessary connections & testing as approved and directed by by the Engineer-in-Charge Approved Makes: D-Link, Havells, Commrax, Molex
Providing and fixing 6U/9U/12U Wall-Mount Rack ,Mounting: Standard 19" mountable ,Material: Powder-coated steel frame,Doors: Front transparent/metal door with lock,Cooling: Provision for cooling fans ,Cable Management: In-built cable management trays,Capacity: 6U to 12U depending on switch size as approved and directed by the Engineer-in-Charge Approved Makes: Rittal, Comrack, Dynamic
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Approved make:Anchor,AKG,RKG,Precision Pipes,Diplast
Conditions:-
The work shall be carried out according to CPWD General Specifications.
The work shall be completed to the entire satisfaction of the Engineer-in-charge.
The firm will have to follow fair wage clause.
Sub-standard work will not be accepted.
No claim on account of fluctuation in prices due to any reason shall be considered.
The quantity can be increased or decreased as per actual requirement at site.
The conditional tenders shall not be accepted.
No premium will be allowed on M.R. Items, abatement, if any shall be applicable on all items including market rates.
The contractor has to employ qualified Engineer for the supervision of work at site.
Any error or omission in nomenclature or unit can be corrected at any stage.
The quality of material shall be strictly in accordance with the specification given in DNIT.
All the material shall be inspected by the Engineer-in-charge of work before installation at site.
The boards & M.S. boxes should be painted with 2 coats of superior quality paint after one coat of primer.
Separate colour of wires shall be used for phase and neutral so as to distinguish it for live conductor.
All the cable/ wire connections should be done through lugs / thimbles duly crimped with proper crimping tools & no extra payment shall be made on this account.
The department has reserve the right to issue any amendment to the work order as emergency demands or allow of altogether cancel the contract without assigning any reason. The department reserves the right to delete / add any item.
Discount offered by the firm should also be considered in deviation of items.
The extra/substitute items will not be allowed against this work.
Security shall be deducted on each running/ Final bill of the firm as per CPWD works manual.
The firm shall ensure, the availability a licensed electrician/ supervisor/ qualified Engineer during the erection, testing and commissioning.
The contractor will have to produce invoice/ gate pass of the manufacturer for major items of material to be installed against S/E of work for genuine of the material.
The firm shall be quote the rates inclusive all the taxes/ GST whatever required and no extra payment shall be made in this respect.
The fittings/ material should be got inspected by the concerned AE with the representative of the firm and necessary certificate should be signed by the representative of the firm for its genuineness.
Any deviations to the clauses in the tender specifications must be clearly and separately indicated otherwise it shall be presumed that the offer is in line with requirements of tender.
The work of S/E material except LED fittings/ fans shall be guaranteed for a period of one year against any manufacturing defect from date of handing over to the department. No extra payment shall be made on the account of labour charges, installation at site.
The LED fittings/ LED drivers/ LED tube rods/ fans shall be guaranteed for a period of two years for free replacement from the date of completion of work / taking over the department.
The firm will submit the test report for LM-79 & IEC standards for safety, performance and Efficacy of LED fittings from Govt./ NABL/ UL accredited lab.
The firm will submit the LM-80 report from the chip manufacturer of LED fittings.
One Number LED fitting of each type i.e. 2’x2’ LED Fitting surface Type,2’x2’ LED Fitting recess Type and 1’x1’ LED Fitting surface Type taken from lot of fitting and shall be got tested for Photometric Test, Electrical Parameters, THD, Surge Protection, IP Rating from the 3rd party NABL Govt. approved lab before installation at site. The cost in respect of testing LED fittings shall be borne by the Department. If the fitting fails the test, the firm has to install the other approved make of the fitting and the cost for the testing of other make fitting from the lab shall be borne by the firm if required.
Approved Makes.
Steel Conduit :-BEC,AKG,RKG, Precision Pipes
PVC Conduit:-Anchor, AKG,RKG, Precision Pipes, Diplast.
FRLS Wires:-Havells, Finolex, RR Kable, KEI, Grandley.
Switches/sockets(Premium).:- Havells, (REO) (Athena), Goldmedal(Air)(GIFa).Anchor(Pental)Legrand (arteor), L&t (Entice)
Switches/sockets (Premium):- Havells, (Athena), Goldmedal, (GIFa).Anchor,Legrand (arteor), L&t (Entice)
MCB’s and Distribution board:- Havells, ABB, Legrand, L&T, Schneider, C&S ( Distribution board and MCB has to be of same company).
MCCB’s and switchgear:- Havells, ABB, Legrand, L&T, Schneider, C&S
Bus bars Copper:- Havells, Anchor
Geyser:- Havells, racold, bajaj,Goldmedal, jaguar ( 5 star rated).
Cat 6:- Havells, Dlink, Legrand, KEI.
Ceiling fan, BLDC:- Atomberg (Efficio), Havells (Efficia Neo), Orient (hector 500), Gold Medal (Maruti), Bajaj (efficial) ( 5 star rated)
Ventilating fans BLDC Plastic body:- Atomberg, Havells orient, Gold Medal, Bajaj ( 5 star rated)
Exhaust fans:- Atomberg, Havells orient, Gold Medal, Bajaj
LED lights polycarbonate body:- Bajaj, havells, Goldmedal,Panasonic, Philips, Wipro, Chengi ( If quantity of LED fittings exceeds 50 in number then testing of fittings is mandatory )
LED lights PDC/CRCA body:- Bajaj, Havells, Panasonic, Philips, Wipro, LT, Chengi. ( If quantity of LED fittings exceeds 50 in number then testing of fittings is mandatory )
LED Lights UGR<19:- Bajaj, Havells, Philips, Wipro, LT, Chengi.
Armoured Cables:- Univesal Cables, KEI Havells, Grandley
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
DeclarationNEW.pdf
Additional Documents • 0.01 MB
SBD_2JudicialNahan.pdf
Tender Documents • 3.95 MB
BOQ_182416.xls
BOQ • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .