| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹11.0 L+₹23,546.81 (2.20%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹11.2 L+₹45,397.85 (4.23%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹13.1 L+₹2.4 L (22.1%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹14.6 L
EMD Value
₹29,160
Closing Date
9 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
ADDITION/ALTERATION OF DOG SQUAD AT 8 FBSU, AF STATION AWANTIPUR
2021_MES_420181_1
GE (AF) AWA-30/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹29,160
Yes
31 Mar 2021
9 Feb 2021
11 Mar 2021
9 Feb 2021
9 Mar 2021
24 Feb 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. not exceeding 10 sqm on plan and not exceeding 1.5metre in depth and getting out in any type of soil, complete all as specified and directed.
Returning filling in, soil including spreading leveling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.5metre high from the starting point, complete all as specified and directed.
Excavation in post holes (or similar holes ) in any type of soil each n. exc 0.5 Cum, getting out,removing soil to a distance n. exc 50M , complete all as specified and directed.
Plain cement concrete, (1:5:10), type E-2 using 40mm graded crushed stone aggregate for foundation filling, mass concrete and sub base of floors, complete all as specified and directed.
Brick work with old size bricks having crushing strength not less than 75Kg/Sqcm, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:4), complete all as specified and directed.
Reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in foundations, footings, foundation beams; bases for coloumns, Plinth beam etc.; and mass concrete, complete all as specified and directed.
Reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in Columns, pillars, piers, posts and struts, complete all as specified and directed.
Reinforced cement concrete M-25 (Design Mix) using 20mm graded crushed stone aggregate as in beams, cantilevers, bresummers and lintels, complete all as specified and directed.
TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
TMT bars 5mm and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and directed.
Rendering 15mm thick on brick work or concrete surface in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered/unplastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
Plain cement concrete, (1:2:4), type B-0 using 12.5mm graded crushed stone aggregate, 25mm thick, surface finished fair to receive top layer of flooring, complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM (1:4), complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick for wall tiles as in skirting/dado in CM (1:4), complete all as specified and directed.
Glazed ceramic coloured/printed tiles (premium quality) of size 300mm x 200mm x 7 to 8mm thick, on vertical surface such as skirting/dado etc set & jointed in cement slurry and pointed with white or coloured cement to match the colour tiles including 10mm thick rendering on brick/concrete surface in cement mortor (1:3) , complete all as specified and directed.
Matt finish ceramic coloured/printed tiles (premium quility) 7 to 8mm thick, (square/ rectangular), area of each tile exceeding 0.11sqm, but not exceeding 0.18sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 10mm thick screed bed or bedding layer in cement mortar (1:4), complete all as specified and directed.
Hard core of stone aggregate of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to true surface, complete all as specified and directed.
Plain cement concrete, (1:3:6), type C-2 using 40mm graded crushed stone aggregate, 75mm thick, as in sub-base of floor etc. finishing surfaces even and fair, complete all as specified and directed.
Plain cement concrete (1:3:6), type C- 1, using 20mm graded crushed aggregate, 50 mm thick, as in plinth protection, laid in alternate bays, finshed even and smooth without using extra cement having 6mm wide joints throughout the thickness of plinth protection in concrete bays and in between walling and plinth protection, the joint of bays of concrete shall be filled with mastic filling comprising of one part of heated bitumen 85/25 or 90/100 grade and three parts of sand (all by weight), complete all as specified and directed.
Mild steel galvanised iron medium grade water tubing 15mm bore with screwed and socket joints, with all fittings, such as sockets, bends, elbows, unions, tees, diminishing pieces etc. fixed to wall and ceiling or laid under floors, complete all as specified and directed.
Bib taps, 15mm bore, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
Rotational moulded polyethylene water storage tank (double layer ISI marked) 1000 Litres capacity (Cylinderical vertical with closed top) hoisted and fixed in position with necessary fitting/fixtures for connecting tank including PVC float valve 20mm dia with polythene float, nipples, check nuts and washers etc. complete and making connections with existing water supply line, all as specified and directed.
Ball brass valve ,high pressure with polythene float and flynut complete screwed for iron pipe or ferrule, 20mm bore, complete all as specified and directed
Stop valve, 20mm bore ,cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions , complete all as specified and directed.
Wash hand basins, Vitreous China (oval type, coloured) size 550mmx400mm, excluding tap etc including brackets with 32 mm bore waste fittings, brass, chromium plated with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, PVC connections 15mm size with CP brass coupling nuts of length 450mm, and Union for discharge pipe, waste, chain and plug and porcelain stopper,chain and plug, PVC 32mm dia waste pipe and all accessories, complete as all specified and directed.
Towel rail of size 20mm dia and 600mm long of PTMT, fixed with and including CP brass screws and wooden/plastic cleats (min weight 190gm), complete all as specified and directed.
Central hole wash hand basin mixer, 15mm bore, brass chromium plated for hot and cold water, complete all as specified and directed.
Plain cement concrete (1:2:4), type B-1 using 20mm graded crushed stone aggregate as in lintels upto 1.50 metres clear span, steps, seismic and other similar bands, coping, bed plates for serving hold fasts, filling in mild steel frames etc. and the like including weathering slighting rounded or chamfered angles and throating, and use of form work (straight or curved) complete all as specified and directed.
Rolled mild steel structural steel works as in roof trusses (framed), trussed, posts, struts, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, base plate and gusset plates etc confirming to Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and directed.
Machine cut kota stone slab of size 55cmX55cmx 18 to 22 mm thick, as in flooring over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete, laid over and including 20 mm thick screed bed or bedding layer in cement mortor (1:6), complete all specified and directed.
Galvanised corrugated mild steel sheeting, with two corrugation side lap fixed with 'L' type or 'J' type or cranked hook bolts with washers in roof, 0.63mm thick, grade-O quality, with 120gms/sqm zinc coating and grade 'B' Class 8, complete all as specified and directed.
Galvanised, plain mild steel sheeting, fixed with 'L' type or 'J' type or cranked hook bolts with washers, in ridges, hips, vally gutters drip and straight flashings (length and girth as fixed) , 0.63mm thick, grade-O quality, with 120gm/sqm zinc coating, complete all as specified and directed.
Rolled mild steel work as in doors or gate of angle of other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting(exlusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing , conforming to Fe-410-W (Gde-E-250) quality-A complete all as specified and directed.
Mild steel, plain, black sheet 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed.
Steel windows or ventilators side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete, with glazing bars, dovetailed or welded , complete all as specified and directed.
Sheet glass, ordinary quality, 3mm thick, glazing with oil putty in squares, not exceeding 0.50sqm in each pane, in steel windows, complete all as specified and directed.
Preparation of newly untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide or zinc chromate,complete all as specified and directed.
Flat Iron Fillets for securing chain link fencing etc including necessary drilling holes ,bolting ot riviting etc and similar work conforming to Fe-290 Gde E-165,complete all as specified and directed.
Fixing only chain link fencing including line wire, any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and directed.
Supply only Chain link fencing including wires(weight exc 4.0 kg/sqm) confirming to IS, type standards rails, straining bolts etc including provision of binding wire, complete all as specified and directed.
Prelaminated particle board 18/19mm thick, interior grade,prelaminated both sides with decorative choice lamination and other side balancing white lamination, fixed with nails as in kitchen cabinet/shelves/ cub board shutters including 6mm thick teak wood bead all around , complete all as specified and directed.
Hasp and staple, safets type, of size 75mm long, aluminium anodised with hinge pin including bolt to hinge plate and fixed with screws, complete all as specified and directed.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, 40 mm width of flaps (when open) , complete all as specified and directed.
40mm dia, cupboard knobs brass polished fixed with nut, screw and washer of mild steel, complete all as specified and directed.
Ball catcher with 8mm dia steel ball, and brass body and striking plate including letting in and fixed, complete all as specified and directed.
2nd class soft wood (Kail) plain, solid, straight chowkats and frames, wrought, framed, rebated on solid, rounded or chamfered, put together with glue, pinned at joints with one or more rebates, complete all as specified and directed.
Plywood, grade BWP, 6mm thick, type BB with 5 Nos of ply, fixed with screws to mild steel frame work as in ceiling, including necessary wooden fillet of appropriate size, complete all as specified and directed.
Framed work as in false ceiling, doors or gates of angle or other section with gusset plates, rails, braces, etc. complete drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-410 grade,complete all as specified and directed.
Preparation of newly untreated steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer ,complete all as specified and directed.
Preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
Preparing new plastered or un-plastered surfaces of walls and applying two coats of Acrylic exterior emulsion paint in camouflaging (Disruptive) pattern (Green, Grey and Brown colour) over a coat of acrylic primer, complete all as specified and directed.
Welded steel wire fabric (Weight per square metre n exc 4Kg). supplied & fixed to steel members with reviting, bolting, welding or any other means, complete all as specified and directed.
Plain cement concrete, (1:3:6), type C-2 using 20mm graded crushed stone aggregate, as in Surface channel and drains, complete all as specified and directed.
M&L Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as speciied and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping, ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes made out of MS sheet with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and as directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one No, one way switch on same board.
Description all as per serial item No. 58 here-in-before, but using cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed
Piano type switch socket combination, flush type, 6 pin, 6/16 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz, complete all as specified and directed.
LED tube light fitting box type 230 volts AC suitable for & including 18/20 watts LED tube rod with bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, ccomplete all as specified and directed.:(Batten fiting suitable for LED tube rod).
LED bulk head light fittings 07 watt, 230 volts AC made up of pressure die cast housing, IP65 protection, 5700K including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories, complete all as specified and directed. Make: Havells cat part No. LHEXCGP7UNW006 or equivalent in Philips/CROMPTON.
Ceiling fan 1200mm sweep 230 Volts by means of fastner or making hole for fixing fan in existing roof with regulator electronic type, complete all as specified and directed.
Exhaust fan single phase 230Volts, 300mm sweep in MS body,including louvres with all connected accessories including making opening for fitting of exhaust fan by breaking wall and making good to the disturbed surface as required, complete all as specified and directed.
Supply, installation and testing energy efficient, water heater storage type, BEE 5 star rated of capacity 50 litres having steel tank with all asscessories such as air release valve, CP connections for hot and cold supply including fixing arrangement , complete all as specified and directed.
Cutting including screwing existing steel tubing for alterations or additions including tee/nipple upto 25-32 mm dia pipe, complete all as specified and directed.
Stop valve, 15mm bore ,cast copper alloy, chromium plated, fancy type, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions , complete all specified and directed.
15mm dia, 450mm long, PVC connection with brass nut and washer , complete all as specified and directed.
Sheet metal enclosure DB SPN 8 way,(IP 43 protection) double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
MCB SP, 6-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and directed.
MCB SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, complete all as specified and directed.
Submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size (ISI marked) and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp, 240 volts , complete all as specified and as directed.
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 6 Sqmm, 2 core including making electrical connections, complete all as specified and directed.
Sand cushioning to underground cable 8 cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river sand, complete all as specified and directed. Note :- Punned thickness shall be measured and paid.
Well burnt old size sub class 'B' bricks of nominal size 230X115X75 mm abutting each other for cable protection, complete all as specified and directed.
Earthing complete with galvanized mild steel plate 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI wire 4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 15mm GI pipe light grade for earth wire protection complete with earth pit in plain cement concrete 1:2:4, type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete 1:2:4, type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and as directed .
MS Ghulam Hassan and Sons
M/S GEE EMM MIR
M/S BASHIR AHMAD AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .