| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.5 LAccepted-AOC | L1 | Accepted-AOC Awarded | |
| 2 | L2₹94.9 L+₹19.5 L (25.8%)Rejected-AOC NEW DUDHNOI GOALPARA | NEW DUDHNOI | GOALPARA | ASSAM | L2 | Rejected-AOC Not Awarded | |
| 3 | Rejected-Technical ALI JORHAT P O P S JORHAT DISTRICT JORHAT PIN 785001 | JORHAT | ASSAM | 785001 | - | Rejected-Technical Technically not qualified | |
| 4 | Rejected-Technical KAHILIPARA ROAD JATIA DISPUR GUWAHATI 06 | KAMRUP METRO | ASSAM | 781006 | - | Rejected-Technical Technically not qualified | |
| 5 | Rejected-Technical DIRECTORATE OF DAIRY DEVELOPMENT ASSAM KHANAPARA GUWAHATI 22 | GOLAGHAT | ASSAM | 785601 | - | Rejected-Technical Technically not qualified |
Tender Value
₹94.9 L
EMD Value
₹1.9 L
Closing Date
10 Mar 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR
DIRECTORATE OF DAIRY DEVELOPMENT DEPARTMENT, ASSAM, KHANAPARA, GUWAHATI -22
Construction of Multi Brand Milk Parlor building( Civil part) at TMSS Jorhat under RIDF XXVII
2023_AHVD_29373_1
DD/RIDF-XXVII/2/22-23/9457-60
Open Tender
Civil Works
Item Rate
180 days
Jorhat
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
₹1.9 L
Yes
DIRECTORATE OF DAIRY DEVELOPMENT DEPARTMENT, ASSAM
10 Apr 2023
17 Feb 2023
10 Mar 2023
17 Feb 2023
10 Mar 2023
28 Feb 2023
27 Feb 2023
Amount
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared.Junmgle clearance like cutting, felling and removing trees etc. as per directed
Jungle clerance
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth
Beyond 60 cm girth upto and including 120 cm girth
Earth work in surface excavation not exceed-ing 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of exc-avated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil
Supplying chemical emulsion in sealed containers include--ing delivery as specified. 1.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONST RUCTIONAL anti -termite treatment (excluding the cost of chemical emulsion) : 2.35.1 Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration metre
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including With Chlorpyriphos/ Lindane E.C. 20% with 1%
Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.1 Mild steel and Medium Tensile steel bars
Centering and shuttering
Centering and shuttering including strutting, propping etc. and removal of form for.
For Beam, lintels etc.
For Roof slab
RCC work
Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,Portland /Pozzolana / Ordinary Portland /Portland Slag cement, admi-xtures in recommended prop-ortions as per IS: 9103 to accel-erate / retard setting of concrete, to improve dur-ability and workability without impairing strength; including pumping of conc-rete to site of laying, curing, carriagefor all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level M25 grade. At Foundation below plinth level
5.33.2 All works above plinth level upto floor V level Concrete of M25 grade
Tile brick masonry with common burnt clay F.P.S. (non modular) tile bricks of class designation 10 in foundation and plinth in: 6.16.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.With river sand or silt obtained by truck carriag
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1cement:2 coarse sand (zone-III) derived from naturalsources : 4 graded stone aggregate 20mm nominal size derived from natural sources).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : 6.12.2 cement mortar 1:4 (1 cement : 4 coarse sand)
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.65mm dia rafter, 50mm dia Purlin, Ladder
15 mm cement plaster on the rough side of single or half brick wall of Mix: 13.2.1 1:4 (1 cement: 4 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 11.41.2 Size of Tile 600x600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approv-ed make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing corrugated G.S. sheet roofing including vertical /curved surface fixed with poly-mer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steelprimer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Kiln seasoned and chemically treated hollock wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of requiredsize with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge.(Note:-Butt hinges and necessary screws shall be paid separately) Kiln seasoned and chemically treated hollock wood. 35mm thick.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture including providing and fixing top & bottom pivot & double action hydraulic floor spring type fixing arrangement and taking necessary holes etc. for fixing required door fittings all complete as per the direction of Engineer-in-charge.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Grill for windows.
Providing and fixing double glazed hermeti-cally sealed glazing in aluminium windows, venti-lators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including pro-viding EPDM gasket, perforated aluminium spa-cers, desic-cants, sealant (Both primary and secon-dary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arran-gement, stoppers, handles, including applying a priming coat of approved steel primer.
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
Providing 10 mm thick plaster of Paris(gypsum anhydrous) ceiling up to a height of 5 m above floor level over first class kail wood strips 25x6 mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately):12.31.1 Flat surfaces
Providing and fixing stainless steel (Grade 304) railing made of hollow tubes , channels ,plates etc. including welding grinding , buffing polishing and making curvature( wherever required) and fitting the same necessary stainless steel nuts and bolts complete i.e fixing the railing with necessary accessories and stainless steel dash fasteneres ...
Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wallsurface to prepare the surface even and smooth complete.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats.
Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consi-sting of applying: (a) after surface prepa-ration, first layer of slurry of cement @0.488 kg/sqm mixed with water proofing cement compound @0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.
Supply installation, Fixing of Dry Chemical Powder Fire Extinguisher confir-ming to IS:2171 with ISI make and CO2 cartridges will be cofirming to IS : 4947 with ISI mark , powder will be confirming to IS: 4308 with ISI Mark (10kg) BRAND FIRESTOP/ FIREND /FIRE SHIELD.
Supplying and fitting & fixing of Glow sign boad including required stand for ereection of sign board size 3.30M x0.90 M as per directed by the Deptt.
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub gra-de of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. Range of three urinal basins with 10 litre white P.V.C. automatic flushing cistern
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard patt-ern, including painting of fittings and brackets, cutting and making good the walls wherever require. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing soil, waste and vent pipes : 100mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Chlorin-ated Polyvinyl Chloride (CPVC) pipes,
Providing and fixing Chlorin-ated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints completeas per direction of Engineer in Charge.15mm nominal outer dia pipes
20mm nominal outer dia pipes
Valve
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
20 mm nominal bore
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
Providing and fixing brass stop cock of approved quality :15 mm nominal bore
Supplying, fitting and placing in position plastic cylindrical vertical closed top PCVC tank of Polycon make (111 )2000 litre capacity
Labour for erecting and placing plastic PCVC tank over the staging up to a height 5.00m complete as directed. 2000 Ltr Cap
1 HP single phase centrifugal monoblock pump set (Crompton Greaves/ Aquatic/CRI/V-Guard) with DOL starter (Crompton Greaves /Control switch Gear/BCH/L&T/Siemen make)
Electrical wiring
Wiring for light point/ fan point /exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Group B
Group C
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earth-ing as required. For AC point and For Deep fridge
Wiring for circuit/ submain wiring
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X21.5 sq. mm earth wire
2 X 4 sq. mm + 2 X 4 sq. mm earth wire
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 160 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermo-magnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, .....earthing etc. complete as required.
Supplying including fitting and fixing of following A.C. exhaust fan in the existing hole on the wall of following with making necessary connection as approved by the Deptt. as required complete .Power flow 225mm sweep
Supplying with installation ,testing and commissioning of Hi-wall 5star rating non ducted split type air conditioner of the following capacity with cord-less remote complete with indoor and out door unit copper pipe and electrical connection as approved by the Department upto 5 meter between the room unit and out door unit as directed by the Deptt. ECBC7.4 : 2 Ton capacity
GOPAL CHANDRA BORA
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .