Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC AT DUNGAMAL NH 5 PO INS CHILKA VIA BALUGAON DIST KHORDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC work awarded to MS RCBConstructions Index No D 343 for Rs 2191401.50 after deducting Credit being the lowest tenderer. | |
| 2 | L2₹29.0 L+₹4.1 L (16.3%)Rejected-Finance AT BRAJARAJPUR PO INS CHILKA DISTT KHURDHA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being other than the Lowest tenderer | |
| 3 | L3₹31.9 L+₹7.0 L (27.9%)Rejected-Finance AT DUNGAMAL NH 5 POST NB CHILKA VIA BALUGAON DIST KHURDA ORISSA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being other than the Lowest tenderer | |
| 4 | L4₹31.9 L+₹7.0 L (27.9%)Rejected-Finance | L4 | Rejected-Finance Being other than the Lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹69,000
Closing Date
11 Sept 2020, 6:00 pmClosed
CWE No 2 Visakhapatnam
CWE No 2 Visakhapatnam Station Road Chief Engineer complex Visakhapatnam 4
SPECIAL REPAIRS REPLACEMENT OF OLD CORROSIVE EXTERNAL GI WATER SUPPLY PIPE LINE RISING IN MARRIED CIVILIAN ACCN AT INS CHILKA
2020_MES_365114_2
82481
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE Chilka
Class D cat a ii
6 documents required · 6 mandatory
₹500
Yes
GE Chilka
₹69,000
Yes
8 Oct 2020
19 Aug 2020
15 Sept 2020
19 Aug 2020
11 Sept 2020
21 Aug 2020
19 Aug 2020 - 20 Aug 2020
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,for foundations / taking out/ laying of GI pipe lines, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in any type of soil complete all as specified.
Removing excavated material to a distance not exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Taking up old corroded/unserviceable GI Pipes of size 50 mm bore including all fittings and fixtures from trenches/wall/floor,etc complete all as speicifed and directed.
All as per Item No. 4 above but of size 40 mm bore
All as per Item No. 4 above but of size 25 mm bore
All as per Item No. 4 above but of size 20 mm bore
All as per Item No. 4 above but of size 15 mm bore
Supply and lay Galvanised Iron pipe 50 mm bore (medium grade) including fittings such as reduces,bends,elbows,union,etc laid in trenches and connecting to the existing pipe line complete all as specified and directed.
All as per Item No. 9 above but of size 40 mm bore
All as per Item No. 9 above but of size 25 mm bore
Supply and lay Galvanised Iron pipe 25 mm bore (medium grade) including fittings such as reduces,bends,elbows,union,etc fixed on floors or walls and connecting to the existing pipe line as fixed in repairs complete all as specified and directed.
All as per Item No. 12 above but of size 20 mm bore
All as per Item No. 12 above but of size 15 mm bore
S&F Gun Metal Globe or Gate Valve of size 50 mm dia, ISI Marked with iron wheel head, screwed both ends for iron pipe and as fixed in repairs complete all as specified and directed.
All as per Item No. 15 above but of size 40 mm dia
All as per Item No. 15 above but of size 25 mm dia
All as per Item No. 15 above but of size 20 mm dia
S&F Ball brass valves of size 25 mm dia,high pressure, with polyethylene float and flynut complete, screwed for iron pipe or brass ferrule and as fixed in repairs complete all as specified and directed.
All as per Item No. 19 above but of size 20 mm dia
M&L Cutting the existingRoad/PCC drain for laying GI pipe line including necessary earth work excavation and getting out in any type of soil, return filling,removal of surplus soil and filling top surface with 300 mm width and 100 mm thick by using PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) and for making good the distrubed surfaces neatly finished to match with the existing complete all as specified and directed.
M&L Cutting the existing flooring/plinth protection for laying GI pipe line including necessary earth work excavation and getting out in any type of soil, return filling,removal of surplus soil and filling top surface with 300 mm width and100 mm thick by using PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) and for making good the distrubed surfaces neatly finished to match with the existing complete all as specified and directed.
Demolition of the existing old unserviceable/broken valve chamber of size 450x450x500 mm including PCC foundation,coping and removing the existing angle iron frame,MS sheet cover,etc and making good the distrubed surfaces neatly finished to match with the existing complete all as directed.
ANTARYAMI PANDA AND COMPANY
HARI HARA NAYAK
M/S JAGANNATH SASMAL
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .