Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹2.3 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹2.4 Cr+₹12.6 L (5.59%)Rejected-Finance M S HOMBIZ SECURITY CONSULTANTS C 27 SECTOR G ALIGANJ LUCKNOW UTTAR PRADESH 226024 | LUCKNOW | UTTAR PRADESH | 226024 | ₹2.4 Cr+₹12.6 L (5.59%) | L2 | Rejected-Finance Not being lowest |
Tender Value
₹2.5 Cr
EMD Value
₹4.3 L
Closing Date
24 Sept 2022, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
PROVN OF ENTRY GATE SECURITY SYSTEM AT DCN SUB GP PALAM SPL WORK
2022_MES_539188_1
CEDZ/TOKEN-45 OF 2022
Open Tender
Civil Works
Lump-sum
180 days
Delhi Cantt
As per NIT
9 documents required · 9 mandatory
₹2,000
GE U P/M
₹4.3 L
Yes
10 Oct 2022
20 Jul 2022
26 Sept 2022
20 Jul 2022
24 Sept 2022
10 Sept 2022
Amount
INTERNAL ELECTRIFICATION
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized Iron wire 4.0mm dia connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for watering entering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion. Note : (i) Cost of GI earth wire and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
EXTERNAL ELECTRIFICATION
Supply, installation, testing and commissioning of powder coated outdoor type compartmentalized cubicle LT Feeder pillar box fabricated out of 3.15mm thick CRCA sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables including, supply and fixing of following switchgear and accessories in the panel. complete as required. The panel should be CPRI approved and having protection IP 65. INCOMER : 1 No. 125 A, 415V, 36 KA, 4P MCCB with variable O/C, S/C & E/F Microprocessor based releases. 1 No. Digital type multifunction meter to show 0 - 500V, 0-100A, Kwh meter and set of cast resin C.T.'s of suitable ratio 1 set of Phase indicating lamp for RYB BUS BARS: 200A TPN bus bars of aluminium alloy with epoxy based insulation. OUT GOING: MCCB TP 100A, 25 KA - 01 No ( Thermal magnatic release.) MCB TP 40 A, 16 KA- 03 Nos MCB DP 32 A,16 KA- 02 Nos MCB SPN 25 A, 16 KA- 05 Nos The foundation shall be provided at site as per recommandation of manufacturers design & drawing cost for the same is deemed to be included in unit rate of above item.
Supply, installation, testing and commissioning of powder coated outdoor type compartmentalized cubicle LT Feeder pillar box fabricated out of 3.15 mm thick CRCA sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50Hz, 3 Phase 4 wire AC supply complete with gland plates, lifting hooks, ventilating louvers, bus bars, inter connections, earthing, labeling electrical interlocking, suitable for termination of cables including, supply and fixing of following switchgear and accessories in the panel. complete as required. The panel should be CPRI approved and having protection IP 65. INCOMER : 1 no. 100 A, 415V, 36 KA, 4P MCCB with variable O/C, S/C & E/F Microprocessor based releases.. 1 No. Digital type multifunction meter to show 0 - 500V, 0-100A, Kwh meter and set of cast resin C.T.'s of suitable ratio 1 set of Phase indicating lamp BUS BARS: 150 A TPN bus bars of aluminium alloy with epoxy based insulation. OUT GOING: MCB TP 40 A, 16 KA- 03 Nos MCB DP 32 A , 16KA -02 No MCB SPN 25 A, 16 KA- 05 Nos The foundation shall be provided at site as per recommandation of manufacturers design & drawing cost for the same is deemed to be included in unit rate of above item.
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized earth strip 25 x4 mm connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 40mm dia GI pipe medium grade for earth strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for entering watering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion. Note : (i) Cost of GI earth strip and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized Iron wire 4.0mm dia connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for earth wire protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for watering entering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion. Note : (i) Cost of GI earth wire and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
M&L for black top Road cutting size of width 0.6M, Depth 0.6 Length 7.0M for laying the pipe for cable protection including excavation, returing filling and disposal of the soil complete and including make a good as before with black Top Road complete all as specified.
SECURITY SYSTEM
Design,Supply ,installation,testing and commissoing of Boom Barrier of length 3.0 Meter length with outdoor application,height of boom from 875 mm ,housing thickenss 2.0mm , electro machanical drive unit,Microprocessor based control unit,boom dimensinon 90x32 mm, IP54 controller protecting rating ,230 V,50/60 HZ ,24 V motor power supply ,200 W Power and Opening/Closing Time - 2 to 6 Secs , 100% Duty cycle,- 20 degree C to +55 degree C operating temperature ,5 million cycle MCBF including necessary foundation/ fixing arrangements ,optical beam sensor ,access control operation, high range receiver,high range remote control,push button ,photosensor for human safety,loop detector, bar with protective rubber profile ,flash point , manual release key in case of power failure ,for better visibity shall be aluminium with red reflective strip and all connected accessories ,including necessary foundation as per OEM instructions complete all as specified and as directed. Make:- Godrej /Brosis/Avon/Gunnebo/BGI Engitech Note:- Civil Work and electric work for installation of above equipment will be scope of the Firm.
Design, Supply ,installation,testing and commissoing of Electro hydraulically operated Tyre-Killer/ Axle breaker ,length of the block 6 mtr Meter, width of the blocked driveway - 6000mm and installation depth 700 mm , height of spike in raised position - 450 mm ,MTBF -05 million cycle operation, load capacity upto 40 Ton, thickness of spike 20mm (minimum),protection class-IP67, Rise/down time-3-5 Sec,blocking angle 60 degree,100% duty cycle, safety against vehicle/human- Loop dector and photo sensor should be provoded. remote control operation, with microprocessor beased control panel and manual operation in case of power failure with 04 cycle up and down movements and manual hand pump ,high level shock resistance and extremely sturdy ,opening speed of 1 seconds ,operating temperature -20 degree C to 60 degree C , with foundation as per manufacturers instructions ,and provide to drainage system with pump set and finishing treatment to all steel element hot dib galvanised + spikes powder painted to red colour RAL3000 and traffic light complete The underground casing should consist of an all around closed sheet steel casing with concrete anchors. The solid blocking spikes are welded to the solid rotation axis in a distance of approx. 200 mm to each other. The axis should be connected with the hydraulic cylinder via a lever system necessary foundation as per OEM instructions all as specified and as directed. Make: Godrej/Tescon/ Brosis/Avon/Gunnebo Note:- Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
Design, Supply ,installation,testing and commissoing of Under Vehicle Scanning System (UVSS) 3D should produce two angular view high resolution 3D COLOR images of the complete underbody of any vehicle passing over it using dual Area-scan camera with ANPR and driver image camera complete based technology should be details given as below:- a) Scaneer/Processor unit Processor - Intel core I7 3.6 Ghz Sensor- Progressive scan CCD/CMOS RAM - 16 GB Storage - 1 TB or more Display image-18.5" or more Operating system- window 10 video format- GIGE Zoom Capability- 16X Scanner size minimum- 1250x 1000 mm Load bearing capacity ( structure)- Upto 40 Ton b) Main Camera of the dual imaging cameras should be of high resolution Area-scan, GigE type with XGA resolution of (1920 x 1200) or above with specification as below Camera Type - Gigabit Ethernet progressive camera Sensor - CMOS XGA resolution (1920 x 1200) or better Field of View - > 155 Format - GiGE Vision compliant specifications Composite Image resolution of the underside - 4 megapixel Camera certification - CE Camera casing ingress protection rating - IP 68, duly certified by NABL accredited lab for upto 24 hours of water proof . scanning Speeed upto 0-30KMPH
(c) ANPR & Driver Cameras must have the following specifications: Sensor type - CMOS XGA area sensor Camera/Len Type- 2MP (varifical lens) Camera Resolution- 1920 x 1080 Video format- H.264/MJPEG/H.265 focus distance- 10-40 Mtr housing protection- IP67 Image Input- Still Image (d) UVSS should be as per specification given as below........ The UVSS should be capable of handling vehicles moving at different speeds ranging from Zero (0) to 30 Km/hr, while the morphed composite images so captured by it should be automatically and dynamically adjusted according to the speed of the vehicle using multiple induction loop based sensors. The UVSS must give output of all the data simultaneously i.e. the composite images, driver photos, vehicle’s frontal image and its number display – all should be displayed on the monitor (as per OEM recommandation) almost instantaneously after the vehicle cross the unit. Also, the system should have a facility to view the composite image, off-line also, for all vehicle . The UVSS should enable detection of suspicious objects that are hard to see via single view scanning systems, including visual access to cavities and niches, areas around suspensions, below the engine areas, side wall of fuel tanks & exhaust pipes etc. The UVSS must have have high security feature to Immediately identifies any foreign object or modifications to the undercarriage by circling them with a RED RING and at the same time activates an audio alarm. The UVSS must also provide a 3D image of the complete underside of any vehicle. Point zoom Comparison of both the images formed by the two area scan camera should be possible to see all the hidden areas . The UVSS must have (scene) view camera, which can capture the complete scenic image & the traffic movement to keep track of vehicle before the vehicle is being scanned and the image of the same will be stored in database. The UVSS should also provide a feature to capture the image of the driver of all RHS driven vehicles, captured through a suitable driver view camera.
Srl No (d) ...........Contd........... The system should have an Automated Number Plate Reading System (ANPRS) tuned to the Indian license plates, i.e. it should be able to automatically read and record a wide range of vehicle registration number plates’ alpha-numeric characters, written in English. Also, the frontal image view of the vehicle to be provided in the GUI, to facilitate manual viewing of the license plate image. in addition to that ANPR should be stand alone system and it must have its own software where all the captured images will be stored and can be cross verified with UVSS software. The System shall have option to input certain vehicle registration number according to category like “wanted”, “suspicious”, “stolen”, “expired” etc by authorized personnel. On successful recognition of registration number the system shall generate automatic alarm. The vehicle categories shall be customizable. The UVSS shall have open protocol for integration with other security systems which will allow operator to give opening command to any other integrated barrier, bollard, tyre killer etc. if scanned vehicle is found OK. The UVSS system must have a facility to take back-up of all the transactions to storage media and must have the facility to generate report in excel, pdf and word format. The UVSS unit should be compact and the underside illumination must be adequate and obtained through a dual array of long life, LED lighting modules. The overall installed unit should be properly designed, and its structure should be able to withstand a vehicle axle-load up to 40-Tons at any point over the structure, so as not to suffer any accidental physical damage to the unit and the components under the pit cover should be in SS 304. Underground cameras & lighting units of the UVSS must be enclosed in a suitable all-weather-proof housing of IP 68 equivalent or higher standard. provide to drainage system with sump pump to be provided to throw the drainage water accumulated in the sump pit for UVSS with all "civil work" shall be complete as per OEM recommandation. Note:- All Civil Work and Elctrical work for installation of above equipment will be scope of the Firm. Make:- Godrej/Tescon / Brosis/GateKeeper/Vehant
Design, Supply Installation, Testing Commissioning of Physical crash rated Electro Hydraulic Bollard set of 05 Fold , with min K12 Physical Crash Rating as per CTS / MIRA / KARCO Standard. As per specification for Crash rated Bollord set of 05 fold as under mentioned... Width of Block drive way - 6 Mtr 1)Blocking Height Min 1200 mm 2) bollard Diameter 355 mm 3)Number of blocking segments 05 Fold 4)Installation depth: 1350mm or as per manufutures standard 5)Drive Unit electro-hydraulic- PLC based 6)Electric motor capacity approx. 3 / 4 kW, 3-phase, 50/60 Hz,400 V 7)Protection class IP 55 8)Total weight 1500 kg approx. 9)Dimension of outdoor cabinet to be fixed to concrete plinth approx. 1200 x 800 x 300 mm (H x W x D) 10)Impact load 926kN, acc to PAS68/ASTM ( Should immobilize 7.5 ton vehicle crashing at a speed of 80 KMPH ) 11)Wheel load 100 kN vertically 12)Operation time Raising 6- 8 sec., lowering 5- 6 sec. Hydraulic fluid Mineral or biodegradable fluid (RSL 22) 13)Operation temperature range - 40 / + 60°C
14) Power failure / emergency operation By integrated hydraulic hand pump 15) Electric controls inside outdoor cabinet - Glass-fiber reinforced cabinet, IP67 16) Hydraulic drive unit - Independent electro hydraulic power drive unit for set of bollards in separate weather- proof lockable protective housing for outdoor installation. Protection class at least IP55. Hydraulic power pack should be in a separate cabinet above the ground at a distance of approx. 15 mtrs (max) from the bollard and all the bollards should be operated simultaneously. 17) Hand pump - for manual or emergency operation in case of Power failure Operation Automated Operation using “UP” & “Down” push button for standalone operation. The bollards shall be in operation- up or down; only till the push button is kept pressed condition. This ensures avoiding accidents due to carelessness of the operator there by ensuring additional safety and operator alertness during operation. 18) Power failure operation - Hydraulic accumulator sufficient to cater to 4 full cycles (up + down ) automatically in case of power failure. 19) Emergency operation Speedy operation in case of emergency (bypassing normal operation ) 20) Surface Protection / galvanizing procedure of Blocking Bollards: Long term corrosion protection by clean blasting of the surface as per SIS 055900, level Sa 3. This is followed by electrical arc galvanizing according to DIN 8565 and DIN 8566. The minimum thickness of the first galvanizing layer should be 100µ. Subsequently followed by two component power coating of 80 µ each. The total thickness of corrosion resistant layers should be min 260 µ. 21) Colour Standard- Colours according to RAL standard or as required.
22) Drainage Provision:- Underground casing of each Blocking Bollard should have outlet at the lowest point of the casing for drainage purpose. An external sump pump to be provided to throw the drainage water accumulated in the soak / sump pit of the bollards near the drainage system. 23)Safety Loops / Sensors:- Two loop detections / Sensors should be provided for safety operation. Led strips (blinking) to be provided with audio alarm during rising & lowering 24) Controllers: Should provide at least the following inputs and outputs (potential free). Inputs Status - Outputs status Open Opened Close Closed Power monitoring Oil Level Phase monitoring Oil pressure , Temp Status 25) Standards:- The System should confirm to CE/UL or any other International Standard Physical Crash test Certification The Manufacturer should furnish physical crash test certificate in accordance with DOS or PAS 68/ ASTM Standards for impact resistance of 926 KN (7.5 ton vehicle crashing at a speed of 80 Kmph) from reputed premier agencies like MIRA / TRL/KARCO 26) Physical Crash Test certification submitted should match the product The crash test should be done on a SINGLE BOLLARD in actual field condition and not on set of 3 or 4 units. “Manufacturer’s declaration, computer simulations or static calculations of testing would not be considered valid”. Make :- Godrej/Tescon/ Brosis/ Gatekeeper/Avon/BGI Engitech Note:- Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
Design,Supply, Installation , Testing and commissoning of 'X' Ray Baggage Scanner System with consist of X ray machine, Image acquisition, recording, storage and display system, input/output roller, servo voltage stabilizer of required capacity with combined test piece/test bag etc fabricated structure of steel frame to house the machine with mobile heavy casters and stable screw jack levelling feet and necessary steel structure to hose image acquisition, recording, storage and display system complete and must be included as per technical specification as below:- 1.General specification:- (i) Tunnel Opening- 650mm(W) X 500mm (H) (ii) Power supply-220 V AC, 50HZ (iii) Imaging- 3D Isometric (iv) Color imaging-3 colors imaging based on atomic number and 6 colors imaging based on atomic number. Ability to move between 3 colors and 6 colors during baggage scanning in real time. (v) Video display -22" high resolution, Low Radiation, Ergonomic, LCD color Monitor. (vi) Conveyor speed - 0.2m/sec (vii) Conveyor load -180kg (distributed load) (viii) Storage temp - -20˚C to 70˚C (ix) Operating temp - 0˚C to 50˚C (x) Conveyor belt height-Range of 750mm and adjustable 100mm. 2. Image processing i. Penetration- In steel 30mm graranted ii. Wire Resolution- 40 AWG Wire Typical, 38 AWG Guaranteed iii. Contrast Sensitivity- 24 Visible Levels, 4096 Gray Levels iv. Beam Divergence- Beam Divergence : 74˚ diagonal vertically up-word. (v) Display Resolution- 1920x1280; 24bit/pixel color. (vi) Resolution and Penetration- Both resolution and penetration should be seen without press of a button.
(vii) Zoom-2X to 64X step & step less Zoom (viii) Material Descrimination-Organic and inorganic material discrimination based on atomic number and density. 3. Computer specification:- (i) Operating System - should be use latest window operating system (ii) Processor- minimum i5 core, 3.0 GHz processor. (iii) Memory- 8 GB RAM (iv) Storage capactiy- 1 TB HDD/SSD (v) Key board & mouse -01 No. (vi) USB Port- 3.0 Support 9 (04 Nos.) (vii) DVD/CD R/W (viii) Video Card- 2GB 4. X-Ray Generator:- (i) Voltage-160 KV rating (ii) Cooling- Sealed Oil bath (iii) Duty Cycle-100% (iv) X ray detector- "L-shaped array 5.Software Features (i) The system shall also have multi energy system with four colour palette for material discrimination high, low, medium peneration. Thin object screening facility like razor blade, envelope etc. (ii) Edge enhancement (a) Inverse Video (b) Black and white image (c) Pleudo colour (d) Bi-direction/scanning (e) Narcs can (f) Automatic image archiving
(iii) The X-ray Beam divergence should be such that the complete image of maximum size of bag is displayed without corner cuts with Edge-enhancement imaging. (iv) Facility for variable contrast must be incorporated to allow enhancement of lighter and darker portion of the image. Facility for image enhancement and image gradient should be available. (v) Machine should be capable of recalling 100 previous images. It should have capability of archiving 50000 and more images. (vi) High Density Alert- Audio visual alarm and draw square around the object area where High density is found. (vii) All software features of machine should be online and password protected and should have PAN option, Date and Time Display. (viii) Threat image projection (TIP) should be available & programmable. (ix) Film Safety : Guaranteed up to ISO 1600 (33 DIN) and Maximum leakage radiation less than 0.1 mR/hr (1µ Sv/hr) (x) The systems should be food safety/film safety/Radiation Safey and AERB/BARC certificate enclosed. Make:- Godrej/Brosis/AV Tech/Astrophysics/Krystal Vision Note:- All civil Work and Electrical work for installation of above equipment will be scope of the Firm
8) operating temperature - 10 to 55 degree celcius 9) Frame dimension- OD: 2220(H) X 810(B) X 500(W) ID: 1980(H) X 700(B)X500(W) 10) Humidity- 95% non condensing 11) In case of power failture- Back up power Battery[12 V dc] back up for a minimum of 8 hours 12) Display unit - The display shall be equipped with alphanumeric display, keypad, including standby button, statusLEDs and audible indicator. 13) Health & safety:- i. Conform to relevant electric safety standard (supported by test certificate from NABL (India) accredited lab or by reputed labs from the country of origin of the equipment) ii. Magnetic field should be harmless to magnetic media,electronic devices, wearers of pacemaker (heart) and pregnant women. Supporting test certificates from NABL (India) accredited lab or by reputed lab from the country of origin of the equipment should be attached. 14) Communication- RS 232/Infra-red/ Ethernet 15) IP rating - IP 55, Make ;- Godrej / Brosis / Astrophysics / CEIA / Garrett Note:- All Civil Work and Elctrical work for installation of above equipment will be scope of the Firm.
Supply, installation,testing and commisssoing of swing Gate motor unit with inbuilt PCB, control unit , Push Button,limit switches with complete accessories, arrangement, bearings, bottom rail track /guideways, wheel & electric wires etc complete for converting the existing iron manual gate at entrance of DCN Palam into automatic sliding motorised type gate by necessary changes in the existing structure by welding, cutting or otherwise.All iron material required for modifying gate and dismantling of existing gates for rework and modification of the same and complete civil and alingment work as required as per site condition as a make good for automatic operating sysytem in existing gate complete scope in the work all as specified and directed. Note:-In an event of power failure, the gate must be able to open and close manually & engaging/ disengaging mechanism to be suitably located & easy to operate.
Supply, Installation, Testing and Commissioning of UHF readers (02 nos.),2 Door Controller 1 no.with 100 cards and 01 no Computer system complete with ACS software all as specified and directed. Make: Honeywell / Brosis / HID/ ID Cube
DG SET
Supply, install, test and commissioning of silent diesel engine driven silent generating set 62.5 KVA/50.0 KW including Microprocessor based AMF Control panel ,Four cylinder in line, radiator cooled engine 415 volts, 3 phase,4 wire ,50 Hz,Comprising of diesel engine alternator mounted and aligned on a common base frame complete with all standard accessories as specified with standard manual control panel,soundless composite acoustic enclousure canopy duly approved by CPCB-2 norms of rating 62.5 KVA/50 KW power factor 0.8 (lagging) and connection as per IE rules complying CPCB/Govt norms of following OEMs :- (a) POWERICA (b) Cummins India Limited (c ) Kirloskar Oil Engines Limited NOTE:- (i) Complete DG set Shall be Procured directly from above mentioned OEMs/manufatures (ii) The foundation shall be provided at site as per recommandation of manufacturers design & drawing cost for the same is deemed to be included in unit rate of above item.
(A) ALTERNATOR: Standard design alternator rated at 62.5 KVA net output at site after considering all derating factors, site conditions and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design with hub and sealed ball/roller bearing, with winding on each pole faces, insulating class H, band of voltage regulation +/- 1% operated voltage from no load to full load and shell conforming to BS-2613/BS-5000 and shell B in position to ganarate supply with frequency regulation within +/- 1% tolerance, revolving field type. (Make of Kirloskar Green/Stamford/Crompton greaves)
(B) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator,air cooled, to drive independently above above alternator and after considering derating as per site conditions directly coupled to alternator thro flexible coupling or multicylinder, multistroke, direct injection, cold starting, 1500 rpm, as per relevant ISI/BS-5514 withan overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under:- ( make of Kirloskar/cummins/Greaves/KOEL)
(i) Fly wheel housing (ii)Air cleaner wet/dry type (iii) Fuel filter (iv) Fuel injection system including injection pump, solenoid switch noozle as per manufacturer's specification (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling. (ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear, start and stop push buttons, ignition key and switch. (x)Residential type exhaust silencer complete with exhaust pipe of 100mm dia outside the acoustic enclosure, all covered with glass wool wrapped with aluminium foil of 28 SWG adequate to create draft for safe exhaust without transferring vibrations to building/wall, flexible exhaust pipe complete.
(xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure, water pump, engine rpm, hour meter and protection against low oil pressure, high water temperature and over speed of engine incl. electronic governing. (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, raditor fan belt, water pump with belts, thermostat (xiv) Fuel hoses. (xv) Separate fuel tank or pay tank made out of 2 mm thick CRCA sheet of suitable capacity not less than 200 litres with level indicator, stop cock, drain plug/valve, breather inlet and outlet connections and all fuel supply lines as required at site and as per manufacturers instructions including return and overflow as well as fuel filling arrangements with piping. (xvi) Air intake system (xvii) Common base frame of sturdy design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions
(C) CONTROL PANEL: Control panel shall be indoor cubical type made out of suitable thick CRCA sheet complete factory made dust and vermin proof, totally enclosed with front opening of 415V 3 phase, 4 wire system AC 50 Hz, having Aluminium busbar of capacity suitable for 110% full load generating set with standard accessories as per manufacturers instructions (D) 2.5mm thick electrical insulating safety mat confirming to IS 15652-2006, working Volt 11KV NOTE: (a) The capacity of generator set shall be net after all de-rating factors as per relevant design. (b) PCC foundation of thickness 150mm bed dimensions as per manufacturers recommendations deemed to be included in the quoted rate
M&L for Earthling complete with galvanised steel earth plate electrode 60cm x60cmx6mm thick buried directly in ground (earth pit not less than 2.25mtr below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, including provision of galvanized earth strip 32 x 6 mm connected by means of bolts nuts, checknuts and washers of galvanized iron or steel, provision of 40mm dia GI pipe medium grade for earth strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe perforated medium grade for entering arrangement and PCC 1:3:6 type CI chamber, MS funnel, wire mesh, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos 8mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type pf soil returning filling in, removal of surplus soil to a distance n.exc.50m, provision of charcoal and salt complete all as shown in electrical plate No3 of Schedule Part-I 2009 all as specified and directed and testing on completion. Note : (i) Cost of GI earth strip and GI protection pipe upto 7.5 Mtr length shall abe deemed to be included in the rate quoted for this item.
Material&Labour,Earth continuity conductor or main earthing lead fixed to wall on batten or recessor chasesor buriedin ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm galvanised iron strip complete all as specified and as directed.
AIR CONDITIONING
Supply, Installation, commissioning and testing of Inverter Technology Split Type wall mounted Air Conditioner cooling based (indoor & outdoor unit with cordless remote control unit) of capacity 1.5 Ton, BEE 5 star rating , fitted with rotary compressor Refrigerant type R-410A/R-32, including outdoor stand (Wall mounted/ Floor mounted), PVC FRLS grade multi stranded copper conductor cable 4 core 2.5 Sqmm for connections with outdoor unit, powder coated brackets/Chowki Stand for outdoor unit, clamps, nuts, bolts washers drilling holes on walls/ceiling for connection/drain pipes complete all as specified and directed. Note:-(i) PVC drain pipes of suitable size & heavy duty Copper connection pipes including suitable insulation upto 3 Mtrs are deemed to be included in above quoted rate.
Supply, Installation, testing and Commissioning of voltage stabilizer for automatic operation single phase, wall mounted ,Copper wounded ,Air cooled with digital display designed for input variation between 160 Volt to 260 Volt with output voltage 220 + 9% Volt with Calibration accuracy + 3% with high low cutoff of capacity 4.0 KVA.
Description of Work / Item(s)
Amount
Total amount of Sch 'A' Section I (Building work) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section I)
Total amount of Sch 'A' Section II (Internal Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section II)
Total amount of Sch 'A' Section III (External Electric Supply) (Pre Priced Amount as in Col 5, brought forward from Total of Sch A section III)
Hombiz Security Consultants
Hombiz Security Consultants
Bidder Name
Leo Network power systems
Hombiz Security Consultants
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .