Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | Admitted-Finance |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
6 Feb 2025, 6:00 pmClosed
GE
GE (I) CAMPBELL BAY, ARMY LAND, CAMPBELL BAY, GREAT NICOBAR-744302
PROVISION OF OPEN COVER SHED ADJACENT TO SAILORS INSTITUTE AND OVER HARD STANDING AT INS KARDIP, KAMORTA UNDER GE(I) CAMPBELL BAY
2024_MES_676216_4
8159/E8
Open Tender
Civil Works
Item Rate
180 days
CAMPBELL BAY
PLEASE REFER TENDER DOCUMENT AND NIT
9 documents required · 9 mandatory
₹500
GE (I) CAMPBELL BAY
₹77,000
Yes
11 Feb 2025
23 Jan 2025
8 Feb 2025
23 Jan 2025
6 Feb 2025
30 Jan 2025
Amount
B/R PORTION Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm complete all as specified and as directed.
M & L for PCC (1:3:6) type C-2 (using 40 mm graded aggregate) as in foundation and mass concrete for angle iron post completed all as specified and as directed.
S & F mild steel work as in roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle channel or flat sections) including brackets, distance pieces, cleats etc., confirming to Fe 410-W (Gde E-250) quality A complete all as specified and as directed.
S & F of pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength of 550 MPa (AZ-150) as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F of pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPa (AZ-150) as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S & F MS work as in wind ties etc., including cutting, drilling and made to shape as required complete all as specified and as directed.
M & L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
E/M PORTION Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation etc., n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in any type of soil all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in soil all as specified and as directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point all as specified and as directed.
S & F XLPE, insulated, armoured, heavy duty, electric cable size 16 Sqmm 4 core with stranded aluminium conductors, 1100 volts grade, laid in tranches/fixing on wall/poles or passing through pipe, including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing on completion with GI protections pipes, complete all as specified and as directed.
S & F for HDPE double wall corrugated pipes conforming to IS-14930 Part-II with IP protection of IP-67 having outer dia 50 mm and inner dia of 38 mm with necessary couplers, bends etc for protection of LT cable all as specified and as directed.
M & L for point wiring concealed/ casing capping on walls and surface on ceiling complete with FRLS PVC insulated unsheathed 1100 Volts grade, conforming to IS-694, 1.5 Sqmm (nominal area) multi stranded copper conductor cable drawn through in and including non metallic medium grade rigid PVC casing capping heavy grade accessories, ISI marked, 19/20mm or of suitable size including all accessories, surface on walls by driling using machine and making good the disturbed surface, with and including suitable boxes, switch plates of suitable make and 1.5 Sq mm copper earth continuity wire connected to earth dolly for One light point controlled by one switch complete all as specified and as directed.
Description all as per Item No 13.00 above but One Fan point controlled by one switch complete all as specified and as directed.
Description all as per Item No 13.00 above but One socket 5 Amps on same board complete all as specified and as directed.
Description all as per Item No 13.00 above but One socket 5 Amps on independent board complete all as specified and as directed.
Description all as per item No 13.00 above but with 4 Sqmm cable for 3 pin 15 Amps socket point controlled by one switch on independent board and 4 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S & F switch piano, flush type single pole, one way 5 Amps complete all as specified and as directed.
S & F socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and as directed.
S & F switch socket combination outlet 2 in 1, 3 pin 5 Amps flush type complete all as specified and as directed.
S & F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and as directed.
S & F Ceiling rose PVC/ polycarbonate insulated body with three terminals complete all as specified and as directed.
S & F wall mounted LED 18/20 watts with out put of 1800 lumens, box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc., complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts including removal of old existing unserviceable tube light fitting complete all as specified and as directed.
S & F Ceiling fan complete with blades, down rod with all accessories, 230V, 1300mm sweep min air delivery 210 CFM with five star rating with BLDC complete all as specified and as directed.
S & F energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opal diffuser pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal of old existing unserviceable tube light fitting complete all as specified and as directed.
M & L for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 2.5 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 2.5.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire and removal of old existing unserviceable one complete all as specified and as directed. Note : (i) 3 Runs of 2.5 Sqmm cable shall be measured as one unit length. (ii) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
S & F in replacement sheet metal enclosure MCB DB TPN 4 way with 200 Amps rated bus bar 415 volts double door with magnitic locking system including refixing / fixing of incomming & outgoing MCBs and making smooth the wall surfaces and removal old existing unserviceable one complete all as specified and as directed.
S & F MCBs of following rating and taking out MCBs of any rating for MCB SP 6 to 32 Amps 240V 10 KA, "C" Series complete all as specified and as directed.
Description all as per Item No 25.00 above but MCB TPN 32 Amps 415V 10 KA, "C" Series complete all as specified and as directed.
M & L for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6mm burried earth pit not less than 2.25m depth below normal ground level with to edge of the plate vertically to depth of not less than 1.5 m below ground level connected to & including galvanised earth wire 4 Sqmm by means of GI bolts & nuts etc with provision of charcoal and salt etc all as per electrical plate No-3 of SSR-2020 including RCC cover and MS angle iron frame, watering with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc, including dismantling and taking out old unserviceable earthing complete all as specified and as directed. Note : (i) Refilling of the earth pit shall be carried out with black cotton soil. (ii) GI wire 4.0mm dia & GI protection pipe upto 7.5 m length will be measured under this item (iii) On testing after completion, if the desired earth resistance is not obtained the earthing will be redone to the entire satisfaction of Engr-in-Charge at no extra cost.
T.M.RAMANATHAN AND SONS (BID ID -3232436)
MAHESWARI CONSTRUCTIONS (BID ID -3233027)
USR Transport (BID ID -3232348)
GSR ENTERPRISES (BID ID -3232884)
KCM BUILDERS & CONSTRUCTIONS (INDIA) PVT.LTD (BID ID -3230760)
M/s Gurunath Construction (BID ID -3232037)
M/S G S GREWAL (BID ID -3232946)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .