Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAccepted-AOC | ₹9.7 Cr Quoted ₹9.2 Cr | L1 | Accepted-AOC AWARDED |
| 2 | L2₹9.9 Cr+₹72.1 L (7.84%)Rejected-AOC | ₹9.9 Cr+₹72.1 L (7.84%) | L2 | Rejected-AOC NOT AWARDED |
| 3 | L3₹10.2 Cr+₹1.0 Cr (11.1%)Rejected-AOC | ₹10.2 Cr+₹1.0 Cr (11.1%) | L3 | Rejected-AOC NOT AWARDED |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹10.2 Cr
EMD Value
₹20.5 L
Closing Date
9 Jan 2020, 4:00 pmClosed
CE,PWD(Border Roads),Chandmari,Ghy-3
O/o Chief Engineer,PWD(Border Roads),Chandmari,Guwahati-3
Dakua to NH15 via duliapathar dongiagaon and No 1 Harmutty
2019_CEASM_86742_1
AS15603
Open Tender
Civil - Roads and Bridges
Item Rate
360 days
Lakhimpur
Please refer Tender documents.
7 documents required · 7 mandatory
₹10,000
CE,PWD(Border Roads),Chandmari,Ghy-3
₹20.5 L
Yes
Guwahati
26 Apr 2021
28 Dec 2019
11 Jan 2020
28 Dec 2019
9 Jan 2020
28 Dec 2019
31 Dec 2019
Amount
Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. i) By Manual Means A) In area of non-thorny jungle
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. I. By Manual Means (B)Cement Concrete
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. I. By Manual Means (C) Reinforced Cement Concrete
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of stone masonry, including disposal of unserviceable material and stacking the serviceable material with all lift and lead of 1000 m as per Technical Specification Clause 202. B. Rubble stone masonry in cement mortar
Removing all types of Hume pipes and stacking within a lead of 1000 m including earthwork and dismantling of masonry works as per Technical specification Clause 202. (B) Above 600 mm to 900 mm dia Hume Pipe
Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3.0m and lead upto 1000 m as per Technical Specification Clause 301.4.
Removal of unsuitable soil including excavation, loading and disposal upto 1000 m lead but excluding compaction ground supporting embankment subgrade replacement by suitable soil, which shall be paid separately as per Clause 303.5.2 as per Technical Specification Clause 302.3.11
Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5 70% reuse
Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 (i) Private Land
Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1. (i) Private Land
Loosening, Levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Tables 300.1 and 300.2 for embankment construction as per Technical Specification Clause 301.4.1.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (A) By Mix in Place Method ii) For Grading II Material
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. Using stone screening Type-B 11.2 mm for Gr.II 2) Grading -II (A) By Manual Means
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. Using stone screening Type-B 11.2 mm for Gr.II 3) Grading –III (A) By Manual Means.
Cement Treated Soil Sub-Base/Base Providing, laying and spreading soil on a prepared sub-grade, pulverising, adding the designed quantity of cement to the spread soil, mixing in place with rotavator, grading with the motor grader and compacting with the road roller at OMC to achieve the desired unconfined compressive strength and to form a layer of sub base/base as per Technical Specification Clause 404. For 4 per cent quantity of cement by weight of soil
Construction of plastic cell filled cement concrete pavement, thickness 100mm (as per design), over a prepared sub base, with 53 grade Ordinary Portland Cement(OPC) or any other type as per Clause 1501.2.4 M30 (Grade), coarse and fine aggregates conforming to IS : 2386, mixing in a concrete mixer of not less than 0.2 cum capacity and appropiate weigh batcher using approved mix design (As per IRC:44-2008), laid in the cells made of high density polythyne sheets of thickness 0.22mm to about 0.25mm,side 150mm and depth 100mm of approximate weight of 1250 kg for a road of 3.75m wide and 1.00km , putting iron spike of 200mm long at the end corners of the cells and using nylon threads passing through the cells 10 mm below the top of the cells, in approved fixed side formwork (steel channe, wedges, steel plates including levelling the formwork as per drawing),maitaining camber of about 3 to3.5%, spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification of Cell filled Concrete Pavement Published by NRRDA
Providing and applying primer coat with bitumen emulsion (CSS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502. (i) Low Porosity
Providing and applying tack coat with Bitumen emulsion (CRS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared granular surfaces treated with primer & cleaned with Hydraulic broom as per Technical Specification Clause 503.
Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using Cold Mix binder to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (II) Using Cold mix Binder (Tailor made as per IRC:SP:100-2014) and by credible technology partners duly licensed by CRRI.
Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels grade and cross fall using Type A,Type B and Type C as per Technical specification clause 510.With cold mix Binder(As per IRC:SP:1002014)and through credible technology partners duly licensed by CRRI. B) By Mechanical Means Case III:Type-C (9.5mm to 2.36mm) Bitumen Emulsion (RS-2)
Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I) Ordinary soil (i) upto 3 m depth Excavation for Structures
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 10 Nominal mix 1:3:6 Base Conc
Providing concrete for plain / reinforced concrete in substructure complete as per drawings and technical specifications Clauses 802, 804, 805, 806, 1202 & 1204 PCC Grade M 20 Nominial mix (1:2:4)
Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification Clauses 613.4 & 1204
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Construction of RCC guide posts of 250 mm dia M15 grade cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical RCC posts not to exceed 1 in 500 as per drawing and technical specification Clause 1608.2
Reinforced cement concrete M 15 grade kilometer stone / local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. ii) Ordinary Kilometer Stone (Precast)
Reinforced cement concrete M 15 grade kilometer stone / local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. iii) 200 m stone (precast)
Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801 ii) 60cm equilateral triangle
Providing & fixing retro – reflectorised cautionary, mandatory and informatory sign as per IRC:67 made encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm 6 mm firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and technical specification Clause 801 iii) 60cm circular
Providing and fixing of typical PMGSY informatory sign board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick, top and middle plate duly welded with MS flat iron 25mm x 5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will primer and two coats of epoxy paint as per drawing Clause 1710 and Annexure 1700.1.
Providing and fixing of typical Citizens Information Board/ Maintenance Information Board with Logo as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 4 nos. steel plate will be welded horizontally with 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 750mm, 750mm below ground level. The 2 nos. steel plate will be welded vertically to 2 nos. 75mm x 75mm of 12 SWG sheet tubes posts duly welded to vertical tubes. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Providing and fixing of typical PMGSY Logo Board as per MORD specifications and drawing. Two nos. 1.6mm thick MS sheet duly welded with 5mm thick steel plate on back on edges. The 2 nos. steel plate will be welded with 1 no. 75mm x 75mm of 12 SWG sheet tube post duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 750mm below ground level. All M.S. will be stove enameled on both sides. Lettering and printing arrows, border etc. will be painted with ready mixed synthetic enamel paint of superior quality in required shade and coloue. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paint as per drawing Clause 1701 and Annexure 1700.1
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A.With Crushed Stone 1.PCC grade M10
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A.With Crushed Stone 1.PCC grade M15
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A.With Crushed Stone II.PCC grade M20
Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203. 1.Coursed rubble masonry (1st sort) ii.In 1:4 cement mortar
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A.With Crushed Stone, upto 5m height 1.PCC Grade M15
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A.With Crushed Stone, upto 5m height III.PCC Grade M20
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A.With Crushed Stone, upto 5m height IV.PCC Grade M25
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Drainage spouts complete as per drawing and technical specifications Clause 1209
Joint Filler IV. Providing and fillling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight.
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX or equivalent)) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 A.With Crushed Stone II. RCC grade M25 a.Height upto 5m
Providing and laying boulder apron for bed protection with stone boulders of minimum size and weight as per Table 1300.1, no fragment weighing less than 25 kg laid dry complete as per drawing and technical specifications Clause 1301
Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification Clause 1204.3.8
Providing pressure relief pipes 100 mm dia in bottom slab of box cell on a filter media base of 500 mm x 500 mm as per drawing and technical specification Clause 1205.5.7
Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 1.Sand filling
Earth work in execution for foundation of structures as per drawings & technical specification, including setting out, construction of sharing and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No. 304 I. In Ordinary Soil A. Manual Means (I)Without Dewatering (i)upto a depth of 3.00m
Earth work in execution for foundation of structures as per drawings & technical specification, including setting out, construction of sharing and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and back filling with approved material as per MORTH clause No. 304 I. In Ordinary Soil A. Manual Means (I)Without Dewatering (ii)3.00m to 6.00m depth
Providing and constructing temporary island 16 m diameter for construction of well foundation for 8m dia. Well.
Providing and Construction of one span service road to reach island location from one prier to another prier location
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specification and removal of excavated earth will all lifts upto 1000m. (Pile diameter 1000mm)
Pile load test on single vertical pile in accordance with IS:2911(Part-IV) a) Initial and routine load test
Providing and laying of PCC M15 levelling course 100 mm thick below the pile cap as per drawing and technical specification of MORTH Section
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification of MORTH Section 1100,1500 & 1700 B RCC Grade M25 (I) Using Concrete Mixer
Supplying, fitting and placing conforming to IS: 1786 TMT reinforcement bar Fe500 in foundation complete as per drawing and technical specifications a) TMT-IS 1786 ( Fe-500 D) from Primary Producer (TATA/ SAIL/Shyam Steel/ Esser Steel/ Jindal panther steel or equivalent
Plain/Reinforced cement concrete, in Substructure compltete as drawing and Technical Specification Clauses 802, 804, 805, 806, 807, 1202, and 1204. I Height 3.0 m to 5.0 m IV. RCC M-25 Grade i. Height upto 5.0m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specification clauses 614, 709, 1204.3.7
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification b) Sandy Material
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size toeards the wall and provided over the entire surfaces behind the abutement, wing wall and return wall to the full height compacted to firm condition complete as per drawing and technical specification.
Supplying, fitting and fixing in position true to line and level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2005 of MoRTH specifications complete including all accessories as per drawing and Technical Specifications.
Furnishing and placing reinforced / prestressed cement concrete in superstructure as per drawing and Technical Specifications at clause 800,1205 and 1205. A with crushed Stone. N. Without Plastisizer ii. RCC M-25 Grade Case I.using concrete mixture For T-Beam and Slab i. Height upto 5.0m
Supplying, fitting and placing TMT (Fe-500 D) reinforcement bar . (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying cement wearing coat M30 grade including rteinforcement complete as per drawing and Technical Specifications of clause 800 and 1206.3A with natural aggerate
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instruction for installation).
Drainage spouts complete as per approved drawings and technical specifications
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and technical specifications Clauses 800 and 1211 A. With crushed stone
P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and technical specifications A. Stone/Boulder
Providing and laying filter material underneath pitching in slopes as per drawing and technical specifications.
Providing and laying boulder apron laid in wirecrates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 percent extra for laps & joints laid with stone boulders weighing not less than 25 kg each as per drawing & technical specification clause 1301 A. Boulder laid dry with wire crates.
A M CONSTRUCTION
SRI TARUN DUTTA
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .