Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC BLOCK NO 7 BEHIND MALTI APTS NEAR SHIV DAIRY WANOWARI PUNE 411040 | PUNE | MAHARASHTRA | 411040 | L1 | Accepted-AOC lowest E-TENDERER | |
| 2 | L2₹11.9 L+₹16,465.25 (1.41%)Rejected-Finance COLABA MUMBAI | L2 | Rejected-Finance Not the lowest e-tenderer | |
| 3 | L3₹12.8 L+₹1.1 L (9.07%)Rejected-Finance | L3 | Rejected-Finance Not the lowest e-tenderer | |
| 4 | L4₹13.1 L+₹1.4 L (12.3%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-Finance Not the lowest e-tenderer | |
| 5 | Rejected-Technical | - | Rejected-Technical Not meeting the eligility criteria |
Tender Value
₹14.2 L
EMD Value
₹29,000
Closing Date
4 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Santosh Pandey
Commander Works Engineer (Army) 24 Assaye Building, Colaba Mumbai-400 005
SPECIAL REPAIR TO ELECTRIC SUPPLY TO KINHAI PUMP HOUSE AT GE DEHU ROAD
2020_MES_358207_4
83937/DR/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE DEHU ROAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE DEHU ROAD
₹29,000
Yes
5 Oct 2020
21 Jul 2020
5 Aug 2020
21 Jul 2020
4 Aug 2020
23 Jul 2020
21 Jul 2020 - 28 Jul 2020
60 days
Amount
Dismantling ACSR conductors of any size from existing poles complete all as directed by Engr-in-Charge.
Dismantling steel or PCC poles/struts, any size setting aside within 50 meters.
Dismantling cross-arms of M.S channel or angle sections etc. complete and setting aside with in 50 m didtance.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard/dense soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in hard/dense soil n.exc 1.5m wide and exc 1.5m depth for laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed by Engineer-in-Charge.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1 flat, size 300mm x 180mm x 40mm
M&L for manufactured sand coushioning with dry and clean over and under the cable for protection of cable , 8.0 cm below cable 15 cm above the cable complete all as directed(Punned thickness shall be measured for payment)
Supply laying in trenches and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable (heavy duty) with strand aluminium conductor ,11000volts grade of size 3 core 95 sq. mm.
M/L for GI tubing 100 mm dia light grade with all necessary fittings on wall/poles including taking down old unserviceable material and etc all as specified and directed.
S & F Cable jointing kit 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
S & F Cable jointing kit 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
S & F steel tubular swaged pole 410 SP-55 (11 mtr long) including CI base plate finial taper plug bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.(Note :- Excavation, PCC work measured and paid separetaly at appropriate items.)
M & L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in foundations, filling and mass concrete of poles & like complete all as specified and directed.
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in coping of poles, plinth blocks of HT/LT poles complete all as specified and directed.
M & L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape of size as indicated or directed .
Supply & fixing in repairs for galvanized stay stranded 7/4.00 mm size complete, including taking down old unserviceable material all as specified and as directed.
M & L for stay assembly complete with accessories as shown in electrical plate No 1 including loop type insulator stay clamp by using stay rod 20 mm dia insulator size 65 mm X 90 mm clearance of 16 mm hole white brown colour complete all as specified and as directed.
M&L for lightning arresters high tension expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 volts set of three
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
Supply and fixing switches air break, gang operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 400 amps 11000 volts complete all as directed at site.
Veer High Tech Solution
S.M.Sales Corporation
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .