Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.0 LAccepted-AOC 968 BAPOO NAGAR RANJHI JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹43.1 L+₹69,797.50 (1.64%)Rejected-Finance 316 A VIJAY NAGAR EXTENSION RANJHI MAIN ROAD JABALPUR MP PIN 482005 | JABALPUR | MADHYA PRADESH | 482005 | L2 | Rejected-Finance Second lowest amount quoted | |
| 3 | L3₹55.7 L+₹13.3 L (31.4%)Rejected-Finance R O 24 GOKALPUR MAIN ROAD JABALPUR MP 482001 | JABALPUR | MADHYA PRADESH | 482001 | L3 | Rejected-Finance Highest amount quoted |
Tender Value
Refer Docs
EMD Value
₹87,500
Closing Date
20 Jul 2023, 6:00 pmClosed
Shri Justin O A, AE (Civ)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
SPECIAL REPAIR TO BLDG NO P-198 (JCOs 08 X QTRS) OF 506 ABW UNDER AGE B/R-II OF GE (EAST) JABALPUR
2023_MES_583474_3
8516/E8
Open Tender
Civil Works
Item Rate
240 days
Garrison Engineer (East) Jabalpur
D a (i)
7 documents required · 7 mandatory
₹500
Garrison Engineer (East) JabalpurNil
₹87,500
Yes
20 Sept 2023
14 Jun 2023
22 Jul 2023
14 Jun 2023
20 Jul 2023
22 Jun 2023
14 Jun 2023 - 17 Jun 2023
Amount
Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete all as specified and directed.
Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L PCC in foundations, filling and mass concrete type E-2 (1:5:10) using 40 mm graded crushed stone aggregate complete all as specified and directed.
M&L PCC in foundations, filling and mass concrete type D-2 (1:4:8) using 40 mm graded crushed stone aggregate complete all as specified and directed.
M&L plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in filling under undulation of roof top/chajja/beam etc with and including necessary formwork complete all as specified and directed.
M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate in fins, fascias, louvres, parapets, and railings exc. 60cm in height, newels, balustrade, and the like complete all as specified and directed.
Supplying only Integral waterproofing compound (ISI Mark) complete all as specified and directed.
M&L for Modular fly ash brickwork with straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
Cutting chases, pinning in, making good to facings for cancealed water tubing and pointing in CM (1:3) cutting n.exc 10cm girth in brick wall complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, n.exc 200mm thick (Horizontal or sloping) rough finished surfaces of concrete flat complete all as specified and directed.
S&F factory made 35mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc, edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, etc, sash bar any numbers complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exc 1.5 Sqm but n.exc 4 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but n.exc 2 Sqm each complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to befitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube, in opening as per specification & drawing complete all as specified and directed.
S&F Aluminium, anodised, barrel tower bolts of extruded section 150mm long complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts of extruded section 100mm long complete all as specified and directed.
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F Butt hinges 75 mm size, medium weight, cold rolled mild steel complete all as specified and directed.
S&F 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete all as specified and directed.
S&F in repair Door spring ordinary rat tail rod pattern springs including roller and roller plate complete of mild steel 300 mm long complete all as specified and directed.
S&F in repair Aluminium handles cast type anodised of 200mm complete all as specified and directed.
S&F Aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
S&F 40 mm dia, brass cup board knobs fixed with nut, screw and washer of mild steel bright complete.
S&F Aluminium anodised Tubular towel rail 20mm dia, D type, 60cm long between flanges incl bracket etc fixed in repair complete all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm with stainless steel wire staples complete all as specified and directed.
M&L Mild steel TMT bars 10 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S&F in repair curtain dropary 25 mm dia PVC coating mild steel fancy type rod of fancy type including brass and brackets with curtain rings of approved quality etc complete all as specified and directed.
S&F in repair mild steel facny type Nobs and bracket and including all necassary fitting complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
Demolition of PCC (unreinforced) below or above ground level n.exc 15 cm thickness and removing rubbish to a distance exc 50 m at low laying area complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for and removing rubbish to a distance exc 50m at low laying area complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in CM internal dia of pipe 100 mm complete all as specified and directed..
S&F in repair steel plate rack size 975 x 750 x 300 mm as complete all as specified and directed.
M&L Water proofing treatment on roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer/authorized applicator of the manufacturer including taking down of existing roof treatment, properly cleaning and drying the concrete surfaces complete all as specified and directed.
M&L 10 mm thick rendering on roof surface/concrete surface in CM 1:4 complete with WPC compound. Note :- WPC shall be measured and paid separately under relevant item.
Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg/Sqm complete all as specified and directed.
Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces complete all as specified and directed.
Laying 3 mm thick unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard weight not less than 3 Kg/Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed.
Applying two coats of bituminous base aluminium paint including preparation complete all as specified and directed.
M&L Machine cut kota stone slab flooring 20-25mm thick over 20mm thick screed in CM(1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including moulding rubbing and mirror polishing complete all as specified and directed.
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick plater in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including moulding, rubbing and mirror polishing complete all as specified and directed.
M&L Granite (Black/Ruby Red) work (table rubbed and polished) 20 mm thick in cooking platforms bedded and jointed with grey cement slurry and pointed to match the shade of granite stone including grinding and polishing types including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
M&L 75mm thick PCC type C-2 (1:3:6) using 40mm graded crushed stone aggregate as in plinth protection finished even and fair including expansion joint at every 3m interval and every corner complete all as specified and directed.
M&L 40mm thick PCC type B-1 (1:2:4) using 20mm graded crushed stone aggregate finishing cement concrete surface even and rough complete all as specified and directed.
S&F Coloured Glazed ceramic tiles in vertical surfaces 350 x 250mm x 7mm/450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick plaster in CM(1:4) on fair face of brick or concrete surface complete all as specified and directed.
All as per Item Srl No 46 here-in-before but skirting use complete all as specified and directed.
Removal of existing detoriated decayed tarfelt or any other treatement including PCC padding, loose surface and removing the debris to a distance n.exc 50 mtr depositing where directed complete all as specified and directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exc 0.11 Sqm but n.exc 0.18sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM(1:6) complete all as specified and directed.
S&F Coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exc 0.18 Sqm but n.exc 0.38sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed in CM (1:6) complete all as specified and directed.
S&F Cement concrete tiles 25cm x 25cm x 22mm thick, with grey cement and no pigment machine pressed, set, jointed and pointed in neat cement slurry in floors and cut and polished over 20mm thick screed in CM(1:6) and joint filling by poly salphate base cement mortar (1:2 ) and matching with exiting surface complete all as specified and directed.
M&L colour Chequered cement concrete tiles glossy finish 30cm x 30cm x 30mm thick with grey cement and pigment, set, jointed filling match with exiting colour and pointed in neat cement slurry in floors with grey cement & pigment over 15mm thick screed in CM(1:6) complete all as specified and directed.
M&L rendering 15mm thick on brick work or concrete surfaces of wall in CM (1:4) in two coats of 10mm first coat including dubbing coat finished even and smooth witout using extra cement and 5 mm final coat both coat mixed with WPC finished even and smooth (without using extra lime or cement) complete all as specified and directed. Note : WPC shall be measured and paid seperately under relevant item.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 5mm thick on fair faces of brick work or concrete surfaces in CM (1:3) in ceiling complete all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for preparation of new plastered surface of wall and aplying two coats of OBD over 3mm thick wall care putty on wall complete all as specified and directed.
M&L complete removal of existing surface of wall and applying two coat of oil bond distamper over 3mm thick wall care putty complete all as specified and directed.
M&L for applying two coats of cement base paint and one coat primer, over a coat of white cement on new wall surface including preparation of surface complete all as specified and directed.
M&L for complete removal of existing surface of wall and applying two coats of cement base paint, over a coat of white cement primer complete all as specified and directed.
M&L for preparition of surface and applying two coats of white wash on and one coat prime wall surface including preparation of surface complete all as specified and directed.
M&L for applying three coats of white wash on new ceiling surface including preparation of surface complete all as specified and directed.
M&L for applying one coat of white wash on ceiling surface including preparation of surface complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead including Sheet glass 3.0mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F Figured glass 3.0mm thick, pin head type and glazing with oil putty in squares n.exc 0.5 sqm in each pane complete all as specified and directed.
Applying two coats of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface and applying one coat of pink primer complete all as specified and directed.
Applying one coat of synthetic enamel paint on wooden surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of old painted surface complete all as specified and directed.
Applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome complete all as specified and directed.
Forming Construction joints joint 30 mm deep x 10 mm wide filled with sealing compoud (Joint will be cleaning properly by mechanicaly and repair CM 1:2 with epoxy mixingand making good and match with existing surface) complete as per sepicified ad directed.
Taking down existing loose plaster and clean rusted reinforcement and exposed concrete surface by sandblasting mechanical devices or any other estabilished methods and follwing stage complete complete all as specified and directed :- (a) Application of two coats of mineral based polymer modified corrosion inhibiting primer Colusal MK+ Colusal 25. (b) Application of two component polymer based bond coat Zentrifix HB+Natufill BB2 or mortar low permeability or guinting with guniting aid. (c) Application Application of carbonation resistant, polymer modified ready to use fine mortar, Nafuquick +natufill BB2 or Zen-trifix F82+Nafufill BB2 Over the whole surface. Make : MC or equivalent.
Repairing sunken floor leakage as per following steps :- Surface preparation: (i) Prior to application of Dr fixit powercrite, ensure to clean the substract which shoud be free from all the dust, foregn particles, loose aggregate and oil grease etc. This can be done with the help of scarifying, grinding water jetting and sand blasting etc. (ii) The surface should be wetted well prior to application throughly with water to get SSD condition. (iii) All the depression or pin holes/pot holes to be repaired using Dr Fixit powercrete method mortar in mixing ratio of (1 kg cement: 1.50 kg silica sand : 0.50kg of Dr Fixit powercrete). Coating application: (i) Mix Cement with Dr. Fixit Powercrete in ratio of 1:0.50 (1 kg cement OP C53 : 0.50 Dr. Fixit Powercrete) by weight. (ii) The mix should be stirred thoroughly until smooth homogeneous paste is obtained. (iii) Apply first coat over SSD /wet condition substrate. (iv) Apply and unroll woven glass fibre cloth evenly on the wet coating before it dries out on larger areas. (v) Using a nylon brush, apply one coat of Dr. Fixit Powercrete coating over the glass fabric so as to cover the fabric, allow 5-6 hours of air drying before application of another coat of Dr. Fixit Powercrete slurry coating over the surface. (vi) Provide polymer modified protective plaster of 15-20 mm thick over the coating to ensure safety from mechanical damage. Curing: (i) Allow Dr. Fixit Powercrete coating to air cure for 3-6 hours after the final coat. (ii) Do not allow the rapid drying of the coating by covering the coating with help of polythene sheet in case of high humidity and windy condition. (iii) However, a moist curing after the air drying is advisable. (iv) Following the moist curing, Dr. Fixit Powercrete coating shall be allowed to air cured for 3 days before submerging it in water. Note: The above procedure is given for Dr Fixit Powercrete, any other equivalent make may please be used as per their manufacturer instruction subject to approve by Engr-in-Charge.
S&F for 50 mm dia GI Pipe light grade for cable protection passing under road/floor or for fixing to poles complete all as specified and directed.
S&F GI Tubes, `medium grade' with all fitting; laid in trenches of 40mm bore with all fitting as in spout pipe 450mm long and embeded in PCC 1:2:4 as directed by Engr-in-Charge at bottom slab level complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm dia CP concealed angle cock for rose shower complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 40mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15mm bore GI tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting chaising pinning and making good to walls and ceiling or laid in floors complete all as specified and directed.
S&F 20mm bore GI tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting chaising pinning and making good to walls and ceiling or laid in floors complete all as specified and directed.
S&F 40 mm bore GI tubes, 'medium grade' galvanised, with all fitting and fixed complete including cutting chaising pinning and making good to walls and ceiling or laid in floors.
Refixing old 15mm dia steel tubing and connections in new or old position (wall, ceilling, floor etc).
Refixing old 20mm dia steel tubing and connections in new or old position (wall, ceilling, floor etc) complete all as specified and directed.
Dismantling water tanks and removing to store exc 250 litre but n.exc 500 litres complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I 500 Litres capacity complete all as specified and directed.
S&F in repair bib tap fancy type chromium plated screwed for iron pipe of 15mm bore complete all as specified and directed.
S&F in repairs CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S&F in repair Angle valves 15 mm bore fancy type, CP, cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair Stop valves 40 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F Ball valves 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe & fixed (minimum weight 20mm-210 gms) complete all as specified and directed.
S&F Grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed.
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm dia complete all as specified and directed.
S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110mm dia complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un-equal of 110 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or un-equal of 75 mm bore of pipe complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm dia complete all as specified and directed.
M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs Vitreous China squatting pan, `Orrisa' pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern & flush pipe) including cement concrete bedding complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern 10 litre capacity, low level, white, with intel, ball valve, float & handle including brackets complete all as specified and directed.
S&F in repairs Brass CP shower rose 125mm size complete all as specified and directed.
S&F in repairs Vitreous China wash basin, white, flat back, size 550 x 400mm excluding taps, waste chain and plug & porcelain stopper but including brackets.
Factory made single extruded WPC (Wood Polymer Composite) solid door frame of size 85 x 45mm comprising of virgin PVC polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC slovent cement and screwed with full body threaded star headed SS screws havng minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticty 900 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed (M.S hold fast/lugs or SS dash fasteners shall be paid for seperately. Note : For WPC solid door minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
All as per item Srl No 107 here-in-before but door frame of size 125 x 65mm.
Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35 mm thick comprising of virgin polymer of K value 58-60 (suspension grade), calcium carbonate and natural fibre (wood powder/rice husk/wheat husk) and non tixic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (face) & 900 N (Edge), minimum compressive strength of 50 N/mm2, modules of elasticty 850 N/mm2 and resistance to spread of flame of Casss A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessay full body threaded star headed counter sunk S.S screws complete all as specified and directed. Note : stainless steel butt hinges and necessary S.S screws shall be paid separately.
S&F precoated steel window Rolled formed GI Section ECO 4000 (Openable double rebate window) Providing and fixing of single rebate openable/fixed windows made of galvanized steel colour coated/powder coated (base steel as per IS 513 of “D" quality, galvanized as per IS 277 with zinc of 120 grams/sqm) with total thickness of coating 0.58 microns, primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer 5-7 microns thick or powder coated with pure polyester powder up to 50-60 microns thick, outer frame section 48 x 50 mm, centre mullion section 48 x 50 mm, shutter section 47 x 20 mm and the fixed glass beading section 12 x 12 mm, outer frame and mullions shall consists rebate for glazed shutter with a 20 mm provision for guard bars/grills and the sections cut to length mitre joined with corner bracket, centre mullion fixed with mullion cap, handle, stay, 2 nos. SS( stainless steel) heavy duty pivot hinges per shutter and window fitted with 5mm thick plain float glass with EPDM (Ethyl Propylene Diamine Monomer) gaskets including fixing frames in concrete/masonry wall by means of self expanding screws, Including 10mm Square bars welded to 6 x 12mm flat at a distance 150mm c/c (pitch) etc complete all as specified and directed.
Supply & Fixing 'in repair' 18 mm thick, PVC sheet one side 1mm prefemlaminated of approved texture ("Celuca ply of Rajshree make or equivalent in "Sintex" as approved by GE) as in Kitchen cabinet (withshelves and partitions) inas per manuacturer's instructions complete all as specified and directed.
Supply & Fixing 'in repair' 18 mm thick, PVC sheet one side prelaminated of approved texture ("Celuca ply of Rajshree make or equivalent in "Sintex" as approved by GE) as in cupboard (withshelves and partitions) as per manuacturer's instructions complete all as specified and directed.
S&F Mortice lock, vertical type size 100 mm 4 lever complete all as specified and directed.
Excavation in trenches for laying of cable, poles and stay n.exc 1.5 mtr wide and n.exc 1.5 mtr deep and getting out in soft/loose soil complete all as specified and dirtected.
Returning and filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25 cm all as specified and dirtected.
Removing excavated materials n.exc 50 mtr and depositing where complete all as specified and dirtected.
M&L for sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and directed. Note :- Measurement shall be done after puning down of sand.
M&L for Fly Ash bricks Sub-class 'B' locally available laid flat in trenches over sand cushioning for cable protection complete all as speciffied and directed.
Taking down carefully copper/aluminium point wiring (light, fan, power point or bell point etc) complete including fixture and fitting such as switches, ceiling rose holders & regulators light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Supply, laying, testing and commissioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trences/ducts, on poles etc of size 50 Sqmm 3.5 core and taking down old Extg unserviceable LT UG/service cable of any size complete all as specified and directed.
M&L for point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty pvc concealed conduit of white/ivory colour including all accessories after chasing in wall/ceilling etc, heavy duty ISI marked with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly, covered with modular white cover plate with inner frame suitable for modular swithes, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps.
One fan point/exhaust fan point controlled by one, one way switch 5 Amps and regulator.
One light controlled by two way switches with cables 1.5 sqmm size.
One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on the same board.
One 3 pin 5 Amps switch socket outlet point controlled by one, one way switch on indelpendednt board.
One bell point controlled by one, one bell switch 5 Amps.
Description all as per item No 121 above but using 2.5 Sqmm single core copper conductor cable of multistranded FRLS, PVC insulated unsheathed 1100 volts grade for 5/15 amps witch socket combination point including necessary running of 2.5 Sqmm copper conductor FRLS, PVC wire as earth continuity conductor alongwith wiring an connecting to the common earth dully, complete all as specified and directed.
Description all as per item No 121 here-in-before but using 4 Sqmm single core copper conductor cable of multistranded FRLS, PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket combination point including necessary running of 4 Sqmm copper conductor FRLS, PVC witre as earth continuity conductor alongwith wiring an connecting to the common earth dully, complete all as specified and directed.
S&F for Energy saving new generation environmental friendly long life versatile pressure source and electronic driver of IP 65, LED street light of capacity 35 watts with pre-wired and necessary mounting arrangements and provision of 2.5 sqmm three core copper conductor cable multistranded from ceiling rose to light fittig including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nuts, bolts etc complete all as specified and directed.
S&F for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen output box type fitting, 230 volts and intregrated electronic driver connector block etc with necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specefied and directed.
S&F round shape 12 watt 220 volts AC recessed type with high eficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lanp suitable for roof ceiling including conncting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F for energy saving new generation 10 watts LED bulk head fitting IP-65 luminaire with opel diffuser pre-wired with warranty option of 5 years from date of installation and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specefied and directed.
Taking down old/unservicable light fitting any type and S&F new 1 x 10 W LED light fittings wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and integrated electric driver including 1 x 10W LED Tube light etc complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size compete all as specified and directed.
S&F Lamp holder, PVC/polycarbonate type with back plate suitable for battan fittings, complete all as specified and directed.
S&F for modular switch piano flush type, single pole, one way and 5/6 Amp, single modular complete all as specified and directed.
S&F for modular Switch piano flush type, single pole, one way and 15/16 Amp, single modular complete all as specified and directed.
S&F for modular Switch 2 way 6A, 1 Module complete all as specified and directed.
S&F for Bell push modular 6 Amps single module complete all as specified and directed.
S&F for Bell Electric Ding dong type suitable for operation on 230 volt 50 Hz, AC supply etc complete all as specified and directed.
S&F modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amps and 2 pin, 5/6 Amp, 2 module piano flush type complete complete all as specified and directed
S&F modular Socket outlet multipurpose having provision for 3 pin, 15/16 Amps and 3 pin, 5/6 Amp, 2 module piano flush type complete complete all as specified and directed
S&F for modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed.
Taking down old/unservicable MCCB any type and Supplying and fixing MCCB 4 Pole, 415 V, adjustable type, 100 Amps with breaking capacity 16 KA complete all as specified and directed.
S&F sheet metal enclosures with socket, plug, top complete clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps including removal of old unserviceable one complete all as specified and directed.
S&F for sheet metal enclosure MCB DB SPN 8 Way vertical type with 200 Amps rated bus bar 240 volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed.
S&F ceiling rose surface type PVC/Polycarbonate isolated body, 65 x 20mm, 3 terminals, complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60 cm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level connecting to and including GI earth wire of size 4.0 mm by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia medium grade pipe for protection of GI wire to the extent of 7.5 mtrs asearthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical plate No 3 of SSR Part-I (2009) including PCC foundation/chamber in mix 1:2:4 type B1 with angle iron frame CI frame, CI cover with provision of locking arrangement and 20 mm dia light grade GI pipe from top edge of the earth plate upto MS funnel with wire mesh provided inside the concrete earth pit for watering arrangement complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal. Note :- Earth protection pipe & earthing wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
M&L for boring hole under the road/path/pavment/hard standing with the help of trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure not less than one metre below ground level complete all as specified and directe at site. Note :- The cost of HDPE pipe shall be deemed to be included in quoted rate.
S&F Modular TV Co-axial socket complete all as specified and directed .
M&L for main wiring with approved colour as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc, one run of PVCinsulated with 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note :- Two runs (with Red/Yellow/Blue colour for Phase + Black colour for Nutral) of 6 Sqmm cable, one run (with Green colour for Earth) of 6 Sqmm cable and one run of PVC conduit will be measured as one unit.
S&F for PVC non-metalic rigid conduit ISI marked heavy duty white/lvory colour and its accessories heavy duty ISI marked of size 25 mm dia for LAN telephone and TV connections including cutting chasses and making good disturbed surface to match with existing finish wih plaster etc complete all as specified and directed.
Taking down old/unservicable MCCB DB any type and M&L distribution board made out of CRCA sheet, powder coated, vertical type, double door, 4 way, including fixing in the wall after chase cutting and making good the surface by necessary patch work and surface finish as per existing including making connections complete all as specified and directed. Make : Havells cat part No DHDLVDRWACF004.
S&F MCB single Pole and neutral rated capacity 40 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
S&F MCB single Pole rated capacity 5 to 32 Amps, 240 Volts, breaking capcity 10 KA "C" curve complete all as specified and directed.
M&L for dismantling and refixing the ceiling fan/exhaust fan obtained from item No 121.02 with replacement of unsv 3 core PVC sheathed 3 core multistranded copper conductor cable of size 23/0.193 from ceiling rose to fan terminal including cleaning all dust etc complete all as specified and directed.
S&F for highly efficient LED bulbs, 10 watt used as a ready replacement for existing GL/CFL/direct fit lamp, in B-22 capacity complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floors and pavings n.exc.15 cm thickness (below or above ground level) complete all as specified and directed.
Schedule of credit amount of Rs. 1,40,876.00 to be deducted during AOC
M/S A.P.M. CONSTRUCTION CO.
m/s R K SETHI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .