Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹37.9 L+₹2.7 L (7.79%)Rejected-Finance 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹39.1 L+₹3.9 L (11.1%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹39.6 L+₹4.5 L (12.7%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹40.2 L+₹5.0 L (14.3%)Rejected-Finance 2 FLAT NO 2 B GEETHANJALI CLASSIK APARTMENT 9TH CROSS KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
21 Sept 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF WATER SUPPLY PIPE LINE PUMPS AND CONNECTED ITEMS UNDER AOR OF AGE E M WORK UNDER GE BLORE
2022_MES_548637_1
8335
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
150 days
BLORE
Class D category a(ii)
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER NORTH BANGALORE
₹66,000
Yes
18 Nov 2022
30 Aug 2022
23 Sept 2022
30 Aug 2022
21 Sept 2022
15 Sept 2022
30 Aug 2022 - 14 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in Soft /Loose soil for laying of pipe lines.
Returning, refilling incl spreading, levelling watering and well ramming in layers not exceeding 25 cm thick with any type of soil all as directed
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed.
Dismantling Old valve pit complete with deteriorated MS cover and Construction of brick massonry valve pit chamber of inner dimension 100x100x100 cms suitable for sluice valves upto 100mm size, with PCC 1:4:8 type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement and fixing of same valve in position where it is removed all as specified as directed. .
Replacement of old unserviceable Ball type foot valve from UG sump and removing unserviceable leather from suction line and replacement the same with high quality leather including nuts, bolts, washer etc and servicing for the following sizes:-. (a) 150 mm dia bore
All as per item No 5 above but for (b) 100 mm bore
All as per item No 5 above but for (c) 80 mm bore
S & F in replacement of sluice valve both side flanged and ISI marked (IS-780) of sluice valve cast iron body with S/S spindle and brass fly nuts, class PN-1.6 and cast iron hand wheel and joining with nut, bolt,washers and rubber insortion packing 6mm thick etc of following sizes:- (a) 200 mm dia bore
All as per item No 8 above but for (b) 150 mm dia bore
All as per item No 8 above but for (c) 100 mm dia bore
All as per item No 8 above but for (d) 80 mm dia bore
Material and labour for repacking stuffing box of sluice valve spindle including taking a part and reassembling of following sizes:- (a) 200 mm bore
All as per item No 12 above but for (b) 150 mm bore
All as per item No 12 above but for (c) 100 mm bore
All as per item No 12 above but for (d) 80 mm bore
Dismantaling the sluice valves in various location and reconditioning the sluice valve by replacing SS spindle , spindle nuts with brass ring, gland nuts, gland packing etc and refixing after properly repairs of the following sizes:- (a) 200 mm dia bore
All as per item No 16 above but for (b) 150 mm dia bore
All as per item No 16 above but for (c) 100 mm dia bore
All as per item No 16 above but for (d) 80 mm dia bore
Replacement of old unserviceable float valve from service tank supply and fix float valve with PVC body aluminium float rod ,nylon float high presure type for the following size:- (a) 20 mm bore
All as per item No 20 above but for (b) 25 mm bore
Replacement of old unserviceable of the existing mechanical type water level gauge supply and fix of water level guage made of mild steel of thickness 4 mm of size 19 feet X 6 feet duly painted/ marked the water level indication on it complete fixed to the supporting pipe with 3 Nos clamps of suitable size all as specified and as directed
Replacement of old unserviceable of the existing mechanical type water level gauge supply and fix of water level guage made of mild steel of thickness 4 mm of size15 Feet X 6 feet duly painted/ marked the water level indication on it complete fixed to the supporting pipe with 3 Nos clamps of suitable size all as specified and as directed
Replacement of old unserviceable of the existing mechanical type water level gauge supply and fix of water level guage made of mild steel of thickness 4 mm of size 13X 6 feet duly painted/ marked the water level indication on it complete fixed to the supporting pipe with 3 Nos clamps of suitable size all as specified and as directed
Supply & fixing in replacement of the following size gun metal Gate valve with iron wheel (a) 15 mm dia
All as per item No 25 above but for (b) 20 mm dia
All as per item No 25 above but for (c) 25 mm dia
All as per item No 25 above but for (d) 40 mm dia
All as per item No 25 above but for (e) 50 mm dia
Taking down old unserviceable of CI/DI water mains (including all fittings), with spigot and socket ends and lead joints/Titan Joints for the following size :- (a) 200 mm bore
All as per item No 30 above but for (b) 150 mm bore
All as per item No 30 above but for (c)100 mm bore
Replacement of old unserviceable DI (Ductile Iron) pipe with spigot and socket end tyton Joint class K9 conforming to IS8329 with inside surface of centrifugally cast cement mortar lined suitable for rubber joint in any length laid in trenches incuding testing all as specified and directed for the following sizes:- (a) 200 mm bore
All as per item No 33 above but for (b) 150 mm bore
All as per item No 33 above but for (c) 100 mm bore
Cutting of DI/CI pipe in position for insertion of CI/DI specials of following sizes;- (a) 300 mm dia
All as per item No 33 above but for (b) 200 mm bore
All as per item No 33 above but for (c) 150 mm bore
All as per item No 33 above but for (d) 100 mm bore
M& L for DI Specials like bends, tappers, tee pieces all sockets, all spitgot, collars, caps & plugs any size & shape as ordered by engineer- in- charge incl testing complete as specified & directed
M& L Run lead joint for water mains of the following size of CI pipes :- (a) 200 mm
All as per item No 41 above but for (b)150mm
All as per item No 41 above but for (c) 100mm Note:- Excavation and earth work shall be measured and paid separately
Taking up the GI pipes / GI flanged pipe with fittings and connected control gate valves / Sluice valve / non return valve / foot valve etc. from sump / trenches / floors / roof for the following size:- . (a) 150 mm bore.
All as per item No 44 above but for (b) 100 mm bore.
All as per item No 44 above but for (c) 80 mm bore.
All as per item No 44 above but for (d) 50mm bore.
All as per item No 44 above but for (e) 40 mm bore
All as per item No 44 above but for (f) 25mm bore.
All as per item No 44 above but for (g) 20mm bore.
All as per item No 44 above but for (h) 15mm dia
S& F GI water tubing medium grade with all fitting laid in trenches / walls of following sizes (a) 150mm dia
All as per item No 52 above but for (b) 100mm dia
All as per item No 52 above but for (c) 80mm dia
All as per item No 52 above but for (d) 50mm dia
All as per item No 52 above but for (e) 40mm dia
All as per item No 52 above but for (f) 25mm dia
All as per item No 52 above but for (g) 20mm dia
All as per item No 52 above but for (h) 15mm dia
Replacement of galvanised iron flanged pipe of medium grade with ISI marked including fittings (such as flange, nut, bolts, washers, elbow, bends etc) laying in trenches/floors also cutting of pipes all as specified and directed for the following size:- (a) GI flanged Pipe 150mm bore
All as per item No 60 above but for (b) GI flanged Pipe 100mm bore
All as per item No 60 above but for (c) GI flanged Pipe 80 mm bore
Replacement of PP-R Pipes and laying and testing in trenches walls/ ceiling/floor 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 (PN-16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/wall complete all as per manufacture's instruction and as directed by Engineer-in Charge. Make SFMC/ WETFLOW/SAFE(Manufactured by poineer) for following sizes :- (a) 16 mm outer dia
All as per item No 63 above but for (b) 20 mm outer dia
All as per item No 63 above but for (c) 25 mm outer dia
All as per item No 63 above but for (d) 32 mm outer dia
All as per item No 63 above but for (e) 40 mm outer dia
All as per item No 63 above but for (f) 50 mm outer dia
All as per item No 63 above but for (f) 63 mm outer dia
S & F in replacement of Poypropylene Random Copolymer (PP-R) Gate Valves with chromiun plated working part Make (SMFC) following size :- (a) 20 mm outer dia
All as per item No 70 above but for (b) 25 mm outer dia
All as per item No 70 above but for (c) 32 mm outer dia
All as per item No 70 above but for (d) 40 mm outer dia
All as per item No 70 above but for (e) 50 mm outer dia
All as per item No 70 above but for (f) 63 mm outer dia
Repairs / maintenance of centrifugal / monoblock pumpsets regularly / systematically including inspection, adjustment, repairs by opening the pump set for carrying out the preventive maintenance and repairs by checking the serviceability and alignment of various spares, removing the unserviceable pump spares and replacing with new spare parts, components servicing, cleaning and overhauling the same by lubricating, replacement of gasket, refixing the same after servicing, testing the same for smooth running, replacing minor parts like gland rope, bolts & nuts, packing, threading and replacing spares and matching inclusive etc all as specified and as directed by Engr-in-charge of the following capacities pump sets. Note : New spares shall be measured and paid separately under relevant items. (a) 90 HP any model & make.
All as per item No 76 above but for (b) 60 HP any model & make .
All as per item No 76 above but for (c) 40 HP any model & make.
All as per item No 76 above but for (d) 15 to 25 HP any model & make.
All as per item No 76 above but for (e) 10 HP any model & make.
All as per item No 76 above but for (f) 7.5 HP any model & make .
All as per item No 76 above but for (g) Upto 5 HP any model & make .
Disconnecting the electric cable from the terminal box of motor/pump upto 10HP capacity, de-coupling the motor from the pump, remove the motor from the foundation bed and taking out the motor, transporting to authorised work shop and performing the required repair works, transporting the motor to site refixing on foundation bed with bolts and nuts, coupling the pump and motor with correct alignment, lubricating with grease and connecting the electrical connection and testing complete all as specified and directed by Engr-in-Charge. NOTE:- Repair works such as rewinding, repalcement of bearings or any other repairs will be measured and paid separately under relvent items.
Disconnecting the electric cable from the terminal box of motor/pump of 10HP to 30 HP capacity, de-coupling the motor from the pump, remove the motor from the foundation bed and taking out the motor, transporting to authorised work shop and performing the required repair works, transporting the motor to site refixing on foundation bed with bolts and nuts, coupling the pump and motor with correct alignment, lubricating with grease and connecting the electrical connection and testing complete all as specified and directed by Engr-in-Charge. NOTE:- Repair works such as rewinding, repalcement of bearings or any other repairs will be measured and paid separately under relvent items.
Disconnecting the electric cable from the terminal box of motor/pump of 30HP to 90 HP capacity, de-coupling the motor from the pump, remove the motor from the foundation bed and taking out the motor, transporting to authorised work shop and performing the required repair works, transporting the motor to site refixing on foundation bed with bolts and nuts, coupling the pump and motor with correct alignment, lubricating with grease and connecting the electrical connection and testing complete all as specified and directed by Engr-in-Charge. NOTE:- Repair works such as rewinding, repalcement of bearings or any other repairs will be measured and paid separately under relvent items.
Dismantling the centrifugal/ monoblock / submersible motor of capacity up to 5 HP and taking out the burnt copper winding / fiber strip / insulating material etc, clean the stator slot by CTC solution and providing copper winding of motor with exisiting guage with insulating material / fiber strip / varnishing, re assemble the motor with proper alignment and air tight etc all as specified and directed by Engr -in- Charge
All as per Sl Item No. 86 above but for capcity 7.5 HP
All as per Sl Item No. 86 above but for capcity 10 HP
All as per Sl Item No. 86 above but for capcity 15 HP
All as per Sl Item No. 86 above but for capcity 25 HP / 30HP.
All as per Sl Item No. 86 above but for capcity 40 HP
All as per Sl Item No. 86 above but for capcity 60/90 HP
Dismantling by opening of the motor of capacity up to 5 HP/3.7 KW and taking out the old unserviceble ball bearings supply and fix new ball bearing of No: 6307 Z/ 6307 2Z or equivalent all as specified and dircected.
All as per Sl Item No. 93 above but for Capcity 7.5 HP / 5.59 KW of No: 6308 N / 6308 N/C3 or equivalent
All as per Sl Item No. 93 above but for Capcity 10 HP / 7.46 KW of No: 6309 or equivalent
All as per Sl Item No. 93 above but for Capcity 15 HP/12.68 KW of Part No:6309 2Z or equivalent
All as per Sl Item No. 93 above but for Capcity 25 HP / 18.65 KW of No: 6311 or equivalent.
All as per Sl Item No. 93 above but for Capcity 30 to 40 HP / 29.8 KW of No: 6312 or equivalent.
All as per Sl Item No. 93 above but for capcity 60 HP to 90 HP/ 44.76 to 67.14 KW of No: 6313 or equivalent.
Supply only ball bearing for Pump set of Capcity 15 HP, Part No : 6309 2Z
Supply only ball bearing for Pump set of Capcity 25 HP, Part No: 6311
Supply only ball bearing for Pump set of Capcity 30 to 40 HP of No: 6312
Supply only ball bearing for Pump set of Capcity 60 HP to 90 HP of No: 6313
Scraping the old painted surfaces by using wire brush / emery paper, preparation of the surfaces and painting with two coats of synthetic enamel paint over one a coat of primer for the following pumpset's /control panel /suction and delivery pipe of the pump house including marking flow of water and MES NO all as per norms complete all as specified and as directed. (a) 90 HP Pump set
All as per Sl Item No. 104 above but for (b) 60 HP Pump set
All as per Sl Item No. 104 above but for (c) 40 HP Pump set
All as per Sl Item No. 104 above but for (d) 15 to 25 HP Pump set
All as per Sl Item No. 104 above but for (e) 10 HP Pump set
All as per Sl Item No. 104 above but for (f) 7.5 HP Pump set
All as per Sl Item No. 104 above but for (g) Upto 5 HP Pump set
Disconnect the electrical connections, lifting the submersible pumpset of any capacity and size along with GI pipe from 500 to 700 feet depth bore well / from open well and dismantling the pump set, transporting to work shop, servcing of pumps, replace the minor parts like bush, washer, water seal etc., including necessary lathe works, fixing the motor and proper insulation, connecting, testing, lowering the same, testing and commissioning all as directed at specified by the Engr-in-charge. NOTE:- Rewinding of motor, replacement of bearing, shaft etc will be measured and paid under relevant items.
Repairing to existing star / delta starter of any type including replacing with new spares ie. Contactor, timer, relays etc suitable for existing make and capacirty of ML1 / ML2 / ML3 / ML4 / ML1.5 / MK1. Note : Spares shall be measured and paid separately under relvent items.
Removing the defective single phase preventer from star/delta starter and supply and fixing new single phase preventer suitable for 60/ 40/ 30/ 25/ 20/ 15/ 12.5/ 10/ 7.5 and 5 HP capacity of motors all as specified and as directed.
Starter contactor, three pole of current capacity 20/22 Amps with I NO + I NC , 415 Volt. Make L &T ML 1.0 or Legrand CTX 4161 19 all as specified and as directed.
Starter contactor, three pole of current capacity 32 Amps Amps with 2 NO + 2 NC , 415 Volt. Make L &T ML 1.5 or Legrand CTX 4161 29 all as specified and as directed.
Starter contactor, three pole of current capacity 40 Amps Amps with 2 NO + 2 NC , 415 Volt. Make L &T ML 2.0 or Legrand CTX 4161 39 all as specified and as directed.
Starter contactor, three pole of current capacity 60 Amps Amps with 2 NO + 2 NC , 415 Volt. Make L &T MK 3 or Legrand CTX 4161 69./Havells all as specified and as directed.
AC control coils of any capacity suitable for mounting on power contactors of voltage range 220 /415 Volt. Make : L & T/ C & S / Havells all as specified and as directed.
Starter relay of any capacity suitable for mounting on power contactors of voltage range 220 /415 Volt. Make : L & T/ C & S / Havells all as specified and as directed.
Auxilary contactor front / side mounting on power contactor of capacity 20-60 Amps suitable for mounting on power contactors of voltage range 415 Volt. Make : L & T/ C & S / Havells all as specified and as directed.
Removing the old / damaged fully automatic motor star / Delta starter by disconnecting incoming/outgoing supply and fix new fully automatic star / delta motor starter of the following model/type/make :- (a) ML 1.0 FASD type suitable for 10 to 20 HP motor.
All as per Sl Item No. 121 above but for (b) ML 2.0 FASD type suitable for 25 to 40 HP motor.
All as per Sl Item No. 121 above but for (c) ML 3 /MK 3 FASD type suitable for 60 to 90 HP motor.
Replacement of Electronic timers ST 100 operating range of 160V to 500V all as per L & T Cat No. ST80328OOOO/ST80329OOOO or techno commercially equivalent makes specified in PS complete all as specified and as directed.
Dismantling the existing old pressure gauge from the pump set/water supply line and provision of new pressure guage 1-10.6 kg per sq cm 100 mm dia dial 3/8" threaded type with stop cock arrangement complete all as specified and as directed.
Replacement of defective pump shaft as per existing type and size of the following capacity pump sets:- (a) 60 HP Pump set
All as per Sl Item No. 126 above but for (b) 40 HP Pump set
All as per Sl Item No. 126 above but for (c) 20 to 25 HP Pump set
All as per Sl Item No. 126 above but for (d) 10 to 15 HP Pump set
All as per Sl Item No. 126 above but for (e) Less than / upto 7.5 HP Pump Set
Dismantaling the old shaft of any type and size, performing the necessary lathe work, remetalling the shaft as per requirement and re fixing of the same for following capacity pump sets:- (a) 60 HP Pump set
All as per Sl Item No. 131 above but for (b) 40 HP Pump set
All as per Sl Item No. 131 above but for (c) 20 to 25 HP Pump set
All as per Sl Item No. 131 above but for (d) 10 to 15 HP Pump set
All as per Sl Item No. 131 above but for (e) Less than / upto 7.5 HP Pump Set
Replacement of existing defective CI star/circular coupling set with rubber gasket for centrifugal pumping set including key, lock, stud etc., complete all accessories as per existing shape and size of the following capacity pump sets. (a) 60 HP Pump set
All as per Sl Item No. 136 above but for (b) 40 HP Pump set
All as per Sl Item No. 136 above but for (c) 20 to 25 HP Pump set
All as per Sl Item No. 136 above but for (d) 10 to 15 HP Pump set
Excavation in trenches not exceeding 1.5 m depth and not exceeding 1.5m width and getting out in Soft / Loose soil for laying of pipe lines complete all as specified as directed.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in Soft / Loose soil etc complete as specified as directed.
Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified as directed.
Replacement of submersible flat copper conductor cable of size 3 core 4 sq.mm complete all as specified and as directed.
Replacement of submersible flat copper conductor cable of size 3 core 6 sq.mm complete all as specified and as directed.
Replacement of GI pipe medium grade 20 mm dia with screwed end / flanged type fixed for the suction / delivery side of the pumps including ncessary welding work / screwing work etc all as speciifed and as direted
Replacement of GI pipe medium grade 25 mm dia with screwed end / flanged type fixed for the suction / delivery side of the pumps including ncessary welding work / screwing work etc all as speciifed and as direted
Replacement of GI pipe medium grade 50 mm dia with screwed end / flanged type fixed for the suction / delivery side of the pumps including ncessary welding work / screwing work etc all as speciifed and as direted
Replacement of GI pipe medium grade80 mm dia with screwed end / flanged type fixed for the suction / delivery side of the pumps including ncessary welding work / screwing work etc all as speciifed and as direted
Replacement of GI pipe medium grade 100 mm dia with screwed end / flanged type fixed for the suction / delivery side of the pumps including ncessary welding work / screwing work etc all as speciifed and as direted
Replacement of Voltmeter analog type of range 0-500 Volts complete all as specified and as directed.
Replacement of Ammeter analog type, of range 0-400 Amps complete all as specified and as directed.
Replacement of LED type indication lamps for RYB indication complete all as specified and as directed.
Removing the pump set from foundation, dismantling the unserviceable MS channel base & foundation, provision of mild steel MS channel / Tee section of the same size and thickness of exisitng one, fabricate the base suitable for the pump motor and fixed to the foundation and motor with necessary nuts, bolts, washers, all fixing arrangements etc including welding, fabrication work, cutting, grinding, making frame etc including foundation concrete in PCC (1:2:4) with necessary form work suitable for pump sets ranging from 20 HP to 90 HP capacity .
Replacement of Delta VFD L 0.75 KW three phase AC Drive, ambient tempreture -20 to 60 degree celsius, out put frequency 1.0 -400 Hz, humidity 90%, motor rating 1 HP, including testing all as specified and as directed.
Shifting of the pumpset from one location to another loaction of capacity 05 HP to 60 HP with disconnection and connection of suction and delivery pipes / electric cable etc including welding screwing work etc as required at site all as specified and as directted.
Replacement of DOL starter of any type including replacing with new one ie.from 5HP to 10HP with all connected items including Contactor, timer, relays etc suitable for existing make and capacirty of ML1 / ML2 / ML3 / ML4 / ML1.5 / MK1 as per site Requirement .
Servicing pressure filter of capacity 60000 LPH by opening pressure filter and taking down filter media of different sizes approximately (7000 Kg) carefully, opening the strainer and reset the same after replacement of filter media cleaning filter nozzles with pressure water, refill the filter bed with fresh media and cleaning the pebbles 20 mm/10mm /40 mm/2 mm topping up the short fall with new media, servicing the backwash system, testing & commissioning all as specified and as directed.
Supply and testing and commissioning of Non- metalic solution tank of 100liters capaciy with motor driven agitator to maintain uniform suspension throghout the tank with following specifications;- Electrically operated chlorine dosing tank consistingof : Dosing tank of 100 litres of PE/FRP MOC with PE/FRP Lid & Level Gauge along with single phase electric motor and agitator with shaft & blade in plastic- mounted on tank. Lid must have port hole for pouring calcium hypochlorite and water when necesssary. lid must have provision for mounting dosing pump on the lid/wall. Make : Altoch or Equavelent
Supply and Fix Non return Butterfly Valve of following size (a) 50mm dia
All as per Sl Item No. 159 above but for (b) 65mm dia
All as per Sl Item No. 159 above but for (c) 100 mm dia
NAVREET CONSTRUCTION
RAMSON TRADERS
YUVARAJ ELECTRIC AND CO
Sreyas Enterprises
H S S ENGINEERS AND CONTRACTORS
g p engineers
VAJRA CONSTRUCTIONS
Atom Engineers and Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .