| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC | ₹1.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.7 Cr+₹2.5 L (1.49%)Rejected-AOC | ₹1.7 Cr+₹2.5 L (1.49%) | L2 | Rejected-AOC Not being L1 |
| 3 | L3₹2.3 Cr+₹55.9 L (33.0%)Rejected-AOC | ₹2.3 Cr+₹55.9 L (33.0%) | L3 | Rejected-AOC Not being L1 |
Tender Value
Refer Docs
EMD Value
₹2.3 L
Closing Date
10 Apr 2021, 6:00 pmClosed
Col PS Chand, CWE
Commander Works Engineer, Minniebay, Port Blair- 744 103
PROVISION OF CONSTRUCTIVE AND MAINTENANCE SHOP AT NSRY, (PBR)
2021_MES_411345_2
80852 Provn of Constructive Maint shop Port Blair
Open Tender
Civil Works
Lump-sum
540 days
Port Blair
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Garrison Engineer (P) North
₹2.3 L
Yes
15 May 2021
9 Mar 2021
13 Apr 2021
9 Mar 2021
10 Apr 2021
24 Mar 2021
Amount
SCHEDUEL 'A' PART- I TO X NOTES: Schedule ‘A’ Part- I to X are prepriced by MES under Ser No. 1.00 to 10.00. Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.
Lump sum price worked out by the tenderer for "Building/Structures" as listed in Schedule 'A' Part-I
Lump sum price worked out by the tenderer for "Excavation, Earth work, site clearance and Land Development" as listed in Schedule 'A' Part-II
Lump sum price worked out by the tenderer for "Internal Electrification" as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the tenderer for "External Water Supply" as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the tenderer for "External Electric Supply" as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the tenderer for "Path" as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the tenderer for "Smoke Detector/Fire Alaram " as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the tenderer for "Area Drainage" as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the tenderer for "Hand Washing Bay With Rain Shed" as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for "Lightining Protection" as listed in Schedule ‘A’ Part-X
Subtotal
NOTE: Schedule ‘A’ Part - XI is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6.
SCHEDULE `A' PART - XI (MISC ITEMS)
Internal Electrification
S&F ultra slim elegance LED lighting fixture with extruded AL housing and poly carbonate heat sink,integrated electronic driver ( Minimum 105 lum/watt), 20 watts ,6000k(4ft) Energy Efficient and environmental friendly, all as directed by the engg-in-charge, Cat no: ENDURALINEARNEOBS20WLED865SPCWH of Havells or equiv in Wipro/Philips/C&S
S&F Air circulator fan 600 mm sweep,heavy duty ,230V, complete including all accessories.Make: Turbo force of Havells or equiv from Bajaj/Crompton/Usha/Almonard
S&F MCB enclosure Sheet Steel, 4 way, Phosphatised, Powder Painted MCB DBs with Din Rail (In accordance with IS 13032 for fixing MCB 4 pole. Make: Havells/C&S/Legrand Note: MCB shall be measured and paid separately.
S&F TPN DB with MCB incoming, 4 way, double door.Cat no: DHDNTHODDW04 Make: havells or equiv in Legrand/Standard/L&T :Note: MCBs shall be measured and paid separately.
S&F TPN DB vertical 4 way with MCCB incoming/4 pole and MCB o/g. Make: Havells, cat no: DHDLVDRWGOFO04 or equiv in Legrand/ L&T Note: MCCB and MCBs shall be measured and paid separately
S&F TPN DB vertical 8 way with MCCB incoming and MCB o/g. Make: Havells, Cat no:DHDLVDRWGOFO08 or equiv in Legrand/ L&T Note: MCCB and MCBs shall be measured and paid separately
S&F MCCB, 4 pole,63 Amp rating,415Volts,16 Ka Breaking capacity,with fixed thermal and magnetic setting all as directed by the engg-in-charge.Make: Havells,Cat no: IHLGNF0063 or equiv in Legrand/L&T/C&S
S&F MCCB, 4 pole,100 Amp rating,415Volts,16 Ka Breaking capacity,with fixed thermal and magnetic setting all as directed by the engg-in-charge.Make: Havells,Cat no: IHLGNF0100 # or equiv in Legrand/L&T/C&S
S&F MCCB, 4 pole 125 Amp rating,415Volts,16 Ka Breaking capacity,with fixed thermal and magnetic setting all as directed by the engg-in-charge.Make: Havells,Cat no: IHLGNF0125 # or equiv in Legrand/L&T/C&S
S&F MCCB, 4 pole 160 Amp rating,415Volts,25Ka Breaking capacity,with fixed thermal and magnetic setting all as directed by the engg-in-charge.Make: Havells,Cat no:IHLGHF0160 # or equiv in Legrand/L&T/C&S
S&F MCB , 3 pole, 40 Amp, C Series 415 volts, 10KA breaking capacity as directed by engg-in-charge Make: havells/Legrand.L&T
S&F MCB, 4 pole,40 Amp rating,C Series 415Volts,10 Ka Breaking capacity as directed by the engg-in-charge.Make: Havells,Cat no:DHMGCFPF040 or equiv in Legrand/L&T
S&F MCB, 4 pole,63 Amp rating,C Series 415Volts,10 Ka Breaking capacity as directed by the engg-in-charge.Make: Havells,Cat no: DHMGCFPF063 or equiv in Legrand/L&T
S&F MCB, 3 pole,25 Amp rating,C series, 415Volts,10 Ka Breaking capacity all as directed by the engg-in-charge.Make: Havells,Cat no:DHMGCTPF006-032 or equiv in Legrand/L&T
S&F, MCB, single pole,C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Havells Cat no:DHMGCSPF006-032 or equiv in Legrand/ L&T/
S&F,MCB, SP&N, C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA. Make-Havells ,Cat no:DHMGCSNF006-032 Standard/L&T/Indo Asian.
S&F fan exhaust of sweep 450 mm, 900 RPM heavy duty type, single phase with their all accessories fixed properly on wall surfaces including connecting/testing complete as directed. Make: Havells /Usha/Almonard Note: The cost of making hole for fixing exhaust fan is deemed to be included in the rate quoted by contractor.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, including provision of GI earth strip 32x6 mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for GI strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe medium grade for watering arrangement and PCC 1:3:6 type C2 chamber, MS funnel, wire gauge, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos x 8 mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc. 50m, provision of charcoal and salt complete all as shown in electrical plate No.3 of Schedule Part-I 2009 all as specified and as directed and testing on completion. Note : Cost of GI earth strip and GI protection pipe upto 7.5m length shall be deemed to be included in the rate quoted for this item . GI strip and GI protection pipe beyond 7.5m shall be measured and paid separately.
S&F MCB enclosure Sheet Steel, 2 way, Phosphatised, Powder Painted MCB DBs with Din Rail (In accordance with IS 13032 for fixing MCB . Make: Havells, cat no:DHDESDP or equiv in C&S/Legrand
S&F energy saving environment friendly & robust highbay LED with PDC housing suitable for ceiling (Surface/Suspended) mounting, 100 W with system efficacy upto 150 lm/W including all the accessories for fixing .Make: havells cat no:SAUCERGENXPROHBP100WLED757P90DBOLT G or equiv in Luker/ Philips/C&S
External Water Supply
M/L for cutting the existing GI pipe line 40 mm dia and inserting Tee of size 40x40x25 mm for making new branch conection of PPR pipe of size 25 mm dia including necessary fittings,excavation,returning and filling and depositing excavated material to a distance not exc 50m complete all as specified and as directad.
External Electrification
M&L for cable route indicator, consisting of cast iron round shape 200 mm dia, 12 mm thick with inscription casting as LT cable 1100 Volts grade and fixed with hot dipped GI angle iron of size 40 x 40 mm x 6 mm thick 0.8 mtr long with GI nut bolts, embeded to ground in route of cable with the help of PCC 1:3:6 type C2 30 cm X 30 cm complete.
Supply, installation, testing and commissioning outdoor LT Distribution Panel suitable for 3 phase, 4 wire, 415 volts to Hz supply system with suitable size and powder coating provided with suitable to make it dust/vermin proof. The panel shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thereaded earthing stud at bottom, inner shell completely vermin proof and to accommodate incoming / outgoing MCCB, MCBs and suitable rated TPN aluminum bus bar and extension links of rating not less than 1.5 times the rates capacity of the respective MCCBs. The TPN busbar and extensions link shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on epoxy regin insulator. All control wires shall be with 2.5 sqmm multistandad copper conductor wire and shall be properly bunched, tied ferruled for proper identification and crimped with adequate size of lugs. The panel shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground with PCC 1:3:6, type C2 complete, computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. The panel shall be consist of the following accessories:-
Incoming:- a) MCCB 4 Pole, 400 Amp , 415 Volts, 50 Hz, breaking capacity 36 KA - 01 No Out going:- (a) MCCB 3 Pole, 200 Amp , 415 Volts, 50 Hz, breaking capacity 36 KA - 02 Nos (for Welding shop.) Make : L & T/ Legrand (b) MCCB 3 Pole, 100 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 01 No (for Constructive and maint shop) Make : L & T / Legrand (c) MCCB 3 Pole, 63 Amp , 415 Volts, 50 Hz, breaking capacity 25 KA - 04 No +1 No( for Boat repair bay,Life raft shop , Rigging shop and civil conservancy section ) Make : L & T / Legrand (d) MCB SP Pole 6-32 Amp ,6 KA, 415 Volts, 50 Hz, -02 No ( for street lights) Make : L & T / Legrand (e) 3 Phase digitial type Voltage ,current , frequency meter. - 01 No & with suitable CT's (f) LED Indication lamps R Y B with control fuses.
S & F syntex FRP junction/ looping box for street light fitting with hinged type door of size 250x200x105 mm (internal) with MCB SP 6 Amps 01 No, bakelite base heavy duty 4 way terminal plate 63 Amps capacity.
S&F LED type street light fitting 36 W, pressure die cast aluminium housing with heat resistant toughened glass & IP65 protection including mounting arrangements like light grade GI pipe bracket of suitable dia. of length not less than 1.5m, bent to shape and fixed on poles / wall with two no. of MS flat clamps etc complete with connecting from junction box with suitable size of copper conductor, and testing on completion.Make - C&S Cat No. INDUS/36/W/LS or equivalent to Bajaj, Philips, crompton.
Supply, installation, testing and commissioning outdoor Cubical box with suitable size and powder coating provided with suitable to make it dust/vermin proof. The cubical box shall be made with 3.15 mm thick CRCA sheet for outer shell and inner shell made out of 2mm thick CRCA sheet, double door with front and back openable with locking arrangement, provision of thereaded earthing stud at bottom, inner shell completely vermin proof and to accommodate incoming / outgoing MCCB, The cubical box shall be mounted on 50x50x5mm angle iron stand of height 45cm above ground level and 45cm embedded in ground, computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull be provided. The cubical box shall be consist of the following accessories:- (For Taping) (a) MCCB, 4 Pole 500 Amp,50 KA.- 01 No. (b) LED indicator lamp R,Y,B with control switches -01 set
Supply and fix HDGI octagonal pole 7 meter height having top dia 70 mm and bottom dia 135 mm and thickness 3 mm , including heavy duty GI pile bracket with nuts and bolts , 4 Nos 'J' hook foundation bolts of dia 16 mm and 450 mm long with base plate. Note : PCC/RCC foundation will be measured and paid seperately.
Excacation in post holes not exceeding 0.5 cum for errection of pole , removing the excavated material to a distance not exceeding 50 meter and providing PCC bed and RCC foundation as per the following including form work. (a) Exca- 0.45x0.45x1.2 m (b) Steel 12mm 1.7 Mx 4 Nos =6.8M (c) Steel 08 mm 1.6 Mx 7 Nos =11.2M (d) RCC column M-20 aggragate =0.4mx.0.4mx1.3 m (e) PCC bed -450mmx450mmx100mm D2 1:4:8 using 40 mm graded aggreagate
COOLING APLLAINCES
Supply, installation and commissioning of water cooler 3 star rating fully stainless steel , electric driven (single phase) having approx storage capacity and nominal cooling capacity 80/40 litres per hour. Make : Blue Star/ Voltas/ Usha
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA. Make: V guard/ Cromton/ Philips
FIRE ALARAM
Supply install test and commossioning of ISI Marked PVC insulated 2.5 Sqmm 2 core multistrand copper conductor FRLS armoured round cable RED in colour laid on surface in rigid steel conduit of size 25 mm dia,including GI saddles/ spacers at every 0.3 mtrs complete with GI junction box ,lugs cable compression glands, cable tags and ferruling.
PILE FOUNDATION
Drilling/ boring through any type of soil (soft/loose soil or hadrd/ dense soil) up to depth as directed/ indicated for 500mm outer dia bored cast-in-situ vertical piles duly stabilising the sides by drilling fluids (Reverse or DMC method) or by driving 6mm thick casing pipe upto loose strata or refusal level or by any other approved method and disposal of drilled/ bored material to a distance excedding 50m and not exceeding 100m all as specified and shown on drawings.
All as per Item No.42 above but on soft rock
All as per item No.42 above but on hard rock
Note for Item No.42 to 44 (i) Concrete and reinforcement shall be measured and paid separately. (ii) The boring of piles shall be commenced from original ground level before carrying out site leveling work. The depth of boring of piles shall be measured from the top of original ground level to the approved founding level. (iii) Bentonite slurry used for mixing with soil (obtained from the boring) shall be disposed off out side MD land as directed by the Engineer-in-Charge. The unit rate quoted against above item shall interalia be deemed to included for this operation and no extra payment shall be admissible on this account. (iv) Casing pipe used while driving of piles shall be removed after providing RCC cast in situ piles as directed by the Engineer-in-Charge. The unit rate quoted against above items shall interalia be deemed to include for this operation and no extra payment shall be admissible on this account
Material and labour for RCC M-35 design mix for cast-in-situ piles using tremie method including chipping of piles from cut off level to a minimum height of 50 cm including necessary excavation and earth work together with disposal of chipped off concrete and spoil obtained from excavation to a distance exceeding 500m and not exceeding 1000m complete all as specified and shown on drawings. Note :Reinforcement shall be measured and paid separatly under relevant items of this Schedule.
Carrying out/ conducting standard penetration test all s per IS - 2911 Part-IV - 1985 in the strata where pile is proposed to be rested / terminated including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion and recording the test results and preparing the test sheets complete for 500mm dia piles all as specified and directed.
Carrying out/ conducting testing of pile for Initial load test all as per clause 6.1.5 & 6.1.6 of IS - 2911 Part-IV - 1985, for 60.0 MT on test pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion and recording the test results and preparing the test sheets complete all as specified and directed.
Carrying out/ conducting testing of pile for Routine load test all as per IS-2911 Part-IV- 1985 for 60.00 MT on working pile of 500mm bore including bringing at site all testing equipment, making arrangement for testing and removal of the same after completion and reording the test results and preparing the test sheets complete all as specified and directed.
Material and labour for high strength deformed corrosion resistant steel bars of TMT process, 10mm dia and over, cut to length, bent to shape required including cranking and binding with and including mild steel wire (annealed) not less than 0.90mm dia all as specified and directed.
Material and labour for high strength deformed corrosion resistant steel bars of TMT process, 5mm to 10mm dia cut to length, bent to shape required including cranking and binding with mild steel wire (annealed) not less than 0.90mm dia as in stirrups, spacers and binders all as specified and as directed.
Material and labour for carrying non-destructive integrity test on piles as per IS 14893-2001 using pile integrity tester complete all as specified and as directed.
Subtotal
ACME Consultants
SACKSON ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .