Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC aoc |
| 2 | L2₹2.9 Cr+₹6.5 L (2.25%)Rejected-Finance NO 208 3C THIRUVAMATHUR CROSS ROAD GINGEE SALAI VILLUPURAM TAMIL NADU 605 601 | VILLUPURAM | TAMIL NADU | 605601 | ₹2.9 Cr+₹6.5 L (2.25%) | L2 | Rejected-Finance He is a L2 position. Hence Rejected |
| 3 | L3₹3.3 Cr+₹40.7 L (14.1%)Rejected-Finance | ₹3.3 Cr+₹40.7 L (14.1%) | L3 | Rejected-Finance He is a L3 position. Hence Rejected |
Tender Value
₹2.8 Cr
EMD Value
₹5.6 L
Closing Date
15 Dec 2022, 4:00 pmClosed
EE, PHD, PWD, Puducherry
EE, PHD, PWD, Puducherry
Augmentation of Water Supply System at Thirubuvanaipalayam and Madagadipetpalayam village in Mannadipet Commune, Puducherry under Jal Jeevan Mission
2022_PWDC2_11531_1
26/PHD/2022-23/02
Open Tender
Civil Works
Item Rate
365 days
Uppalam
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,575
₹5.6 L
10 Aug 2023
7 Dec 2022
16 Dec 2022
7 Dec 2022
15 Dec 2022
7 Dec 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth,1.5m in width as well as 10 sqm on plan) including disposal of excavated earth , lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m
Extra for every additional lift of 1.5m or part thereof in : all kinds of soil.
Supplying and filling in plinth with sand under floors including, watering, ramming, consolidating and dressing complete.
Supplying and filling with quarry dust in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth consolidating each deposited layers by ramming and watering etc. Complete including all lead and lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete.(Measurements to be taken of the face area timbered). - Depth not exceeding 1.5m.
Close timbering over areas including strutting, shoring and packing cavities (wherever required) etc. complete. (Measurements to be taken of the face area timbered). - Depth exceeding 1.5m but not exceeding 3m.
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work , using cement content as per approved design mix , including pumping of concrete to site of laying but excluding the cost of centering , shuttering , finishing and reinforcement , including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete , improve workability without impairing strength and durability . Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work upto plinth level .
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work , using cement content as per approved design mix , including pumping of concrete to site of laying but excluding the cost of centering , shuttering , finishing and reinforcement , including admixtures in recommended proportions as per IS : 9103 to accelerate, retard setting of concrete , improve workability without impairing strength and durability . Note:- Cement content considered in this item is @ 330 kg / cum. Excess or less cement used as per design mix is payable or recoverable separately. - All work above plinth level upto floor V level.
Extra for providing richer mixes at all floor levels - Note:- Excess / less cement over the specified cement content used is payable / recoverable separately - Providing M-30 grade concrete instead of M-25 grade BMC / RMC . (Note:- cement content considered in M-30 is @ 340 kg /cum)
Add for using extra cement in the items of design mix over and above the specified cement content therein
Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span upto floor five level including the cost of required centring, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal -size)
Providing , hoisting and fixing upto floor five level precast reinforced cement concrete in shelves including setting in cement mortar 1:3 (1 cement : 3 coarse sand) , cost of required centring , shuttering and finishing with neat cement punning on exposed surfaces but excluding the cost of reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete upto plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
Steel reinforcement for R.C.C.work including straightening , cutting , bending , placing in position and binding all complete above plinth level - Thermo -Mechanically treated bars (TISCON / VIZAG / IISCO / SAIL / JSW) Fe - 415 or more
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacture's specification.
Extra for R.C.C / B.M.C / R.M.C work above floor V level for each four floors or part thereof
Brick work with common burnt clay F.P.S. (non modular ) bricks of class designation 3.5 in foundation and plinth in - cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S (non modular ) bricks of class designation 3.5 in superstructure above plinth level upto floor five level in all shapes and sizes in - cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work / AAC block masonry / Tile brick masonry in super structure abovefoor V level , for each four floors or part thereof by mechanical means
Providing and fixing M.S.round or squre bars with M.S.flats at required spacing in wooden frames of windows and clerestory windows.
Providing 40 X 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bots, nuts and wooden plugs and embeddings in cement concrete block 30 x10 x 15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Providing and fixing ISI marked aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete - 300 X 16 mm
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete - 125 X 63 X 4mm
Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete - 75 X 45 X 3.2 mm
Providing and fixing aluminium tower bolts, ISI marked , anodised (anodic coating not less than grade AC 10 as per IS :1868) , transparent or dyed to required colour or shade , with necessary screws etc. complete - 50 x10 mm
Providing and fixing aluminium tower bolts, ISI marked , anodised (anodic coating not less than grade AC 10 as per IS :1868) , transparent or dyed to required colour or shade , with necessary screws etc. complete - 150 x10 mm
Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,with necessary screws etc, complete - 125 mm
Providing and fixing aluminium handles , ISI marked , anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade,with necessary screws etc, complete - 75 mm
Providing and fixing ball bearing for each rolling shutters
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer - M.S. pipes
Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks , mounted on specially esigned pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to ISS :4454 -part 1 and M.S.top cover of required thickness for rolling shutters - 80 x 1.25mm M.S. laths with 1.25 mm thick top cover
Steel work welded in built up sections / framed work , including cutting, hoisting,fixing in position and applying a primingcoat of approved steel primer using structural steel etc. as required - in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc .complete - 40mm thick with 20mm nominal size stone aggregate
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters,, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. upto floor five level, excluding the cost of centering , shuttering and finishing - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
12mm cement plaster of mix -1:4 ( 1 cement : 4 fine sand)
15mm cement plaster on rough side of single or half brick wall of mix - 1:4 (1 cement : 4 coarse sand)
cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement - 20mm cement plaster
6mm cement plaster of mix 1:3 (1 cement : 3 fine sand)
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof
White washing with lime to give an even shade - new work (three or more coats)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers
Finishing walls with acrylic smooth exterior paint of required shade - New work (two or more coat applied @ 1.67 ltr/10 over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm
Applying priming coat - with ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat - with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron / steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade - Two or more coats on new work
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed nd consolidated and grouted with fine sand, including finishing the top smooth.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 3.5 in superstructure above plinth level upto floor V level - cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and placing in position suitable PVC water stops conforming to IS : 12200for construction / expansion joints betweentwo RCC members and fixed to the reinforcement with binding wire beforpouring concrete etc. complete - Dumb bellwith central bulb (180 mm wide, 8 mm thick)
Extra for half brick masonry in superstructure, above floor five level for every four floors or part thereof by mechanical means
Providing and fixing finished brass hard drawn hooks and eyes -100mm
Extra for additional height in centering , shuttering where ever required width adequate bracing, propping etc. including cost of de - shuttering and decentering at all levels , over a height of 3.5m, for every additional height of 1metre or part thereof (plan area to be measured) - Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Providing wood work in frames of doors , windows, clerestory windows and other frames , wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or ash fastener shall be paid for separately) -Padak wood
Centering and shuttering including struting, propping for 3m height and removal of form for floor slabs , roof slabs, landings, balconies and access platforms.
Centering and shuttering including , strutting, propping etc, and removal of form for foundations , footing , bases of columns etc
Centering and shuttering including strutting , propping etc and removal of form for walls (any thickness) including attached pillastering, buttresses, plinth and string courses etc.
Centering and shuttering including strutting , propping etc and removal of form for lintels, beams , girders ,bracers brussummers and cantilevers etc
Centering and shuttering including strutting , propping etc and removal of form for columns , pillars, piers, abutments , posts and struts
Providing and fixing panelled or panelled and glazed shutters for doors, windows, and clerestory windows, including ISI marked M.S.pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete - Padak wood - 35 mm thick shutters
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors , windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick - Padak wood
Providing two legged scaffolding using 15 cm diameter blue - gum posts or casurina posts or best quality bamboo - posts of 4m over all length (3.0m height + 0.5 m projection + 0.5 into the ground) the distance between the two rows being 1.25 m and the spacing of posts with 0.5 m overlap on either side and braces to step up and providing a platform with country wood planks of 40mm thick and 1m width etc in a complete form using coir and nails 1 m run (Rate of scaffolding for a height of 3 m and lenghth of 1 m).
Exta for Providing two legged scaffolding for every additional height of 2.5 m (Rate for scaffolding for a height of 3 m and length of 1m).
Providing and fixing C.I. sluice valve (PN 1) (with handwheel) conforming to IS 14846 and ISI marked, with bolts, nuts, rubber insertion etc., complete (the tail pieces if required will be paid separately) - 100 mm dia.
Supply and installation of DI D/F Gate Valves (Soft seated ) Resilient seated soft sealing gate valves (Sluice valves ) (Make VAG, AVK, Fouress) with body bonnet of ductile iron of grade GGG 40, wedge fully rubber ined EPDM of good quality W720 ,replaceable spindle nut, without gland packing and with 3 O-ring protection on theshaft and seals of NBR and the valves should be vacuum tight and 100% leak proof with face to face dimensions as per BSS 163-89/ISI 4846 - 2000/DIN3202 F4. All the valves should be Electrostatic powder coated both inside outside with pocket less straight thro body passage. All the valves shall be compatible for burried application without chambers, with pressure rating PN 10/16 - dia 150mm
Providing and laying Ductile Iron Double flanged pipes of class K9 (Electro steel /Lanco/ Jindal/ Electrotherm) conforming to IS specification 8329/2000 and ISI marked suitable for flanged joints in good condition including transportation of D.I. pipe from production centre/company to the site at Puducherry, lowering to the trenches(or fixing in over head tanks above ground level) laying to proper grade and alignment, testing of joints with required testing equipment etc., complete all as per IS12288 and CPWD specification . (earth work and jointing of pipes with rubber insertion will be paid separately) -100mm dia.
Providing and laying Ductile Iron Double flanged pipes of class K9 (Electro steel /Sripipes /Jindal / Electrotherm) conforming to IS specification 8329/2000and ISI marked suitable for flanged jointsin good condition including transportationof D.I. pipe from production centre/company to the site at UT of Puducherry, lowering to the trenches(or fixing in over head tanks above ground level) laying to proper grade and alignment, testing of joints with required testing equipment etc., complete all as per IS12288 and CPWD specification . (earth work and jointing of pipes with rubber insertion will be paid separately) -150mm dia.
Providing and fixing in position flanged standard D.I. specials (Electro steel /Sripipes /Jindal /Kiswok) such as tees, bends, collors, tapers, caps etc. conforming to IS specification 9523/2000 and ISI marked - 100 to 300mm dia.
Providing flanged joints to double flanged C.I./D.I. pipes and specials including necessary bolts, nuts, rubber insertion and testing of joints etc., complete - 100mm diameter pipe.
Providing flanged joints to double flanged C.I./D.I. pipes and specials including necessary bolts, nuts, rubber insertion and testing of joints etc., complete - 150mm diameter pipe.
Threading of CI / DI pipes suitable for fixing flanges including transportation, labour charges etc., complete - 150 mm dia.
Threading of CI / DI pipes suitable for fixing flanges including transportation, labour charges etc., complete - 100 mm dia..
Providing, laying and jointing G.I pipes of medium class (blue)(TATA, TNT Nezone, Apollo, Zenith) conforming to IS specification 1239 part I and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, excluding GI specials such as bends, tees, elbow, coupling, reducer etc., complete all as per IS and CPWD specification. -100mm dia
Providing and fixing in position G.I. bend (UNIQUE/R Brand/HB Brand/UI Brand) conforming to IS 1239 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete -100 mm dia.
Providing and fixing mild steel flange including bolts, nuts, rubber insertion, labour charges etc, complete-100mm dia
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality - 100 mm diameter pipe.
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality - 150 mm diameter pipe.
Providing and fixing of 65mm Godrej Navatal lock of 6 levers etc complete
Supplying and filling with gravel (excluding rock) in layers not exceeding 20cm in depth , breaking clods, watering , rolling each layer with 1/2 tonne roller , or wooden or steel rammers , including all leads and lift etc., complete for making play fields , running trees and court yards
Providing chemical injection treatment in the form of pressure grouting to side walls of OHT/sump CM 1:3 curing etc, complete.
Providing and fixing of G.I. vent cowl pipe of 100mm dia with a vertical height 40cm should ends welded with a 100mm dia G.I. Tee at top and G.I. elbow at both sides of tee ends and embedding it in RCC slab. The rate includes the cost of G.I. pipe, G.I. tee, G.I. elbow – threading and welding, chajjas, dismantling of RCC slab for making holes and embedding into the slab directed by the Engineer – in –charge.
Providing and erecting lightning arrestor with required earthing which includes the cost of 25mmX 6mm thick copper plate copper spike to earth pits fitted over non conductor of electric current with an interval of 90 cm from ground level to top the structure, copper spike of standard size-2 nos of earth pit of 0.3m dia borehole lowered with 40mm dia G.I class B pipe 3.05 m deep (perforated and jointed with G.I funnel) with charcoal and salt covered with 0.45 m dia circular precast ring of 0.6m deep with circular precast cover slab etc.
Supplying and fixing of copper flat (25 x3mm) for earthing arrangements including bolts and nuts etc.
Supplying and laying of 40mm dia. PVC pipe (Class 3 - PN 0.6 Mpa) conforming to IS 4985 : 2000 for inserting submersible cable from borewell to starter.
Providing and fixing 50 mm dia GI pipe (Class B) conforming to IS 1239 (Part 1:1990) with GI fittings including trenching, refilling etc., complete for UG cable duct.
Testing of water tank against leakage and seepage. If any seepage and leakage is found the same has to be rectified and make if good as directed by the Engineer in charge.
Providing and laying Ductile Iron double flanged pipe with Puddle flange confirming to IS Specification 9523/2000 of length 1m and providing Puddle flange at appropriate position as per drawing provided by the Engineer-in-charge and placin the same in the Over Head Tank deck slab while laying concrete with necessary support and true to alignment complete - 100mm dia pipe
Providing and laying Ductile Iron double flanged pipe with Puddle flange confirming to IS Specification 9523/ 2000 of length 1m and providing Puddle flange at appropriate position as per drawing provided by the Engineer-in-charge and place in the same in the Over Head Tank deck slab while laying concrete with necessary support and true to alignment complete - 150mm dia pipe.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size)
Centering and shuttering including strutting, propping etc and removal of form for - foundations, footings, bases of columns etc for mass concrete
Centering and shuttering including strutting, propping etc and removal of form for - Walls (any thickness ) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including sqm strutting, propping etc and removal ofform for - Suspended floors , roofs, landings, balconies and access platform
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m - all kinds of soil - pipes,cables etc , exceeding 80mm dia but not exceeding 300 mm dia
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50m lead - Bituminous road.
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead - nominal concrete 1:3:6 or richer mix.(i/c equivalent design mix)
Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site, lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, end caps etc., complete all as per IS and CPWD specification. - 140mm dia.
Providing, laying and jointing UPVC pipes (Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to propergrade and alignment, testing of joints with required testing equipment ,including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, end caps etc., complete all as per IS and CPWD specification. - 110mm dia.
Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, endcaps etc., complete all as per IS and CPWD specification. - 160mm dia.
Providing, laying and jointing UPVC pipes(Finolex / jain / Supreme / Truebore / Nandi) (0.6 Mpa) conforming to IS specification 4985 and ISI marked including transportation to the site , lowering to the trenches, laying to proper grade and alignment, testing of joints with required testing equipment, including cost of solvent cement, excluding UPVC specials such as bends, tees, threaded pieces, couplers, reducer, end caps etc., complete all as per IS and CPWD specification. - 90mm dia.
Providing and fixing in position UPVC moulded equal Tee (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 90mm dia
Providing and fixing in position UPVC moulded tail piece without flange (Finolex/Jain) (0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110mm dia
Providing and fixing in position UPVC moulded equal Tee (Finolex/ Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110mm dia
Providing and fixing in position UPVC moulded elbow (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc, complete - 140mm dia
Providing and fixing in position UPVC moulded elbow (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110mm dia
Providing and fixing in position UPVC moulded endcap (Finolex /Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked ,including labour charges for jointing, jointing materials etc, complete - 110mm dia
Providing and fixing in position UPVC moulded reducer coupler (Finolex/Jain) (0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc,complete - 160 x 110mm dia
Providing and fixing in position UPVC moulded reducer coupler (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc,complete - 110 x 90mm dia
Providing and fixing in position UPVC moulded elbow (Finolex/ Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc, complete - 90mm dia
Providing and fixing in position UPVC moulded end cap (Finolex/ Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 90mm dia
Providing and fixing in position UPVC moulded unequal Tee (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc,complete - 110 x 90mm dia
Providing and fixing in position UPVC moulded endcap (Finolex/Jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 140mm dia diameter pipe.
Providing and fixing C.I. sluice valve (PN 1.6) (with handwheel) conforming to IS 14846 and ISI marked, with bolts, nuts, rubber insertion etc.,complete (the tailpieces if required will be paid separately) - 100 mm dia.
Providing and fixing C.I. Double air valve with bolts, nuts, rubber insertion etc., complete (the tail pieces if required will be paid separately) - 100 mm dia.
Providing and fixing C.I. Ball type non return valve (PN 1) conforming to IS 318 & IS 1363, with bolts, nuts, rubber insertion etc.,complete (the tail pieces if required will be paid separately) - 100 mm dia.
Providing and fixing in position UPVC moulded plain coupler (Finolex / jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked,including labour charges for jointing, jointing materials etc, complete - 110mm dia
Providing and fixing in position UPVC moulded reducer coupler (Finolex /jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 160 x 140mm dia
Providing and fixing in position UPVC moulded elbow (Finolex / jain)(0.4 Mpa)conforming to IS 7834 part II and ISImarked,including labour charges forjointing, jointing materials etc, complete -160mm dia
Providing and fixing in position UPVC moulded endcap (Finolex / jain)(0.6 Mpa)conforming to IS 7834 part II and ISImarked,including labour charges forjointing, jointing materials etc, complete -160mm dia
Providing and fixing in position UPVC fabricated coupler (Finolex / jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110 mm dia
Providing and fixing in position UPVC fabricated bend (Finolex / jain)(0.6 Mpa) conforming to IS 7834 part II and ISI marked, including labour charges for jointing, jointing materials etc, complete - 110 mm dia
Providing and fixing mild steel flange including bolts, nuts, rubber insertion, labour charges etc,complete-125mm dia
Supplying of electrically operated wet type submersible motor and pumpset (Texmo / KSB / Taro / Kirloskar make), AC 3 phase, 415 volts, 50 Hz, 2900-3000 RPM.The pump shall have brass impeller, high grade steel shaft with sufficient stages having outlet size of 2"/2.5"/3" dia. to suit the borewell (150 / 200mm dia.), complete.The rate includes, all taxes, freight, etc., FOR at site in Puducherry. The pumpset shall be guaranteed for a period of one year from the date of commissioning. (10 HP Submersible motor and pumpset).
Supplying and fixing of 4 KVAR power capacitor (CG/ L&T/ Siemens make) for 10 HP motor complete.
Supplying and fixing of fully automatic air break star-delta starter range for 5A to 13A F.A.S.D. (Bharat Culter hammer/L&T/Siemens make) with suitable M.S. angle frame etc., complete.-
Supplying and fixing of 1x3x4 sqmm (single run) PVC insulated copper submersible flat flexible cable of Finolex make complete.-up to 10HP pump set.
Supplying and fixing of teak wood aerial board with 100 Amps HRC fuse base and fuse link and suitable post clamp to hold the G.I. Pipe with electric post including bolts and nuts etc., complete.
Supplying of 3.5x95 sqmm underground cable (Paragon/ suncab/ Empire) complete.- suitable for (60HP to 75HP pumpset)/(above 40KVA to 75KVA Genset).
Laying of UG cable and providing termination of cable joint with suitable cable gland, cable socket etc., complete - 3.5/4 x 50 / 3.5/4 x 70 sqmm cable.
Laying of under ground cable direct in ground including metal road cutting, excavation of earth, sand cushion, brick protection, back filling etc., complete. - above 50 sqmm
Supplying and fixing of pole clamp to hold the G.I. Pipe with electric post
Making earth pit of G.I pipe for earthing in the earth pit with 40mm dia. G.I. pipe medium class of length 3.05m perforated with 46 Nos. of 12mm dia. Holes, pipe lowered in bore holes of 150mm dia. And filled in with charcoal and salt in alternative layer of 300mm, the top of G.I. pipe shall be clamped. Earth pit shall be provided with 60cm dia precast ring with 60cm depth alround, covered with R.C.C. precast slab etc., as per I.E. standards.
Erection, testing and commissioning of motor and pump set complete. The rate includes obtaining electricity service connection from Electricity Department also.
Supplying and fixing of meter board of size 600mmx900mmx150mm on suitable angle frame with suitable water proof plywood 12mm thick for receiving ED supply. The board frame shall be painted and covered on all sides by 16 gauge M.S. sheet and fixed with 3 Nos. of 100 Amps fuse carrier (Havells / Standard / Anchor make) with screws etc., complete.
Providing and fixing Cast iron flanges conforming to IS specification 1538 and ISI marked. - 100 mm dia.
Supplying and fixing of copper wire 8 SWG (4 mm dia) for earthing arrangements including bolt and nuts etc., complete.
Providing and fixing of 4 pole change over switch of STANDARD /HAVELLS /KUNDAN/ GEM make including M.S. frame as per I.E. standard.-200 Amps(from 62.5/63 KVA to 100 KVA)
Supplying of 3.5/ 4x25 sqmm underground cable (Paragon / suncab /Empire) complete.- upto 25HP pumpset.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plith level - 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Earthwork in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed , within a lead of 50m - all kinds of soil
Providing, laying , spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site , laying in uniform layer by manual means in sub-base / base course on well prepared surface and compacting with smooth 3 wheeled steel roller to achieve the desired density.
Providing and applying tack coat on the prepared surface, heating bitumen in boiler and spraying the bitumen with sprayset fitted on bitumen boiler - on granular base such as WBM and WMM surfaces not bitumen primed. Rate of application 10kg/10sqm.
Providing and laying open graded premix carpet 20mm thick on prepared surface in a single course as wearing course composed of specified size of stone aggregates premix with a bituminous binder in mini hot mix plant 6 to 10 tonne laying manually and rolling with power roller 8 to 10 tonne but excluding cost of primer/tack coat. As per clause no 509 of MOST specification.
Providing and applying liquid seal coat, type `A' comprising of a layer of bituminous binder, followed by a cover of stone chipping of specified grading and rolling with power roller 8 to 10 tonne. As per clause no 513 of MOST specification.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 20mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 25mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required - 32mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required - 1 X 1.5
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -2 x 2.5 sq.mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface / recessed steel / PVC conduit as required -2 x 4 sq.mm
Supplying and fixing of following size of PVC junction box in required position along the line of PVC conduit as required. Make: Avonplast / Vijaya:- 25mm Junction Box two way
Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 300mm X 200mm X 50mm. Deep
Providing and fixing of following size phenolic coated sheet on existing wooden board: - 300mm X 200mm X 3mm Thick.
Supplying and fixing of the following sizes of Teak wooden board on recess including cutting the wall and finishing the surface good the same as required - 375mm X 300mm X 50mm. Deep
Providing and fixing of following size phenolic coated sheet on existing wooden board: - 375mm X 300mm X 3mm Thick
Supplying and fixing S.P 1 way 5/6amps piano/flush type switch on the existing switch box/cover including connections etc. as required. Make: Kundan/Anchor/Vinay :-
Supplying and fixing 3 pin 5/6amps piano/flush type socket outlet on the existing switch box/cover including connections etc. as required. Make: Kundan/ Anchor/ Vinay:-
Supplying and fixing S.P 1 way 15/16amps piano/ flush type switch on the existing switch box/cover including connections etc. as required. Make: Kundan/ Anchor/ Vinay:-
Supplying and fixing 3 pin 15/16amps piano/flush type socket outlet on the existing switch box/cover including connections etc. as required. Make: Kundan/ Anchor/ Vinay:-
Supplying and fixing 5/6amps indicator on the existing switch box/cover including connections etc. as required. Make: Kundan/ Anchor/ Vinay:-
Supplying and fixing 3 pin , 5 A ceiling rose on the existing junction box / wooden block including connection etc as required
Supplying and fixing brass batten / angle holder including connection etc. as required
Providing and fixing of 1 x 36W/40W certified single tube street light fittings with aluminum housing and UV stabilized acrylic cover. (Make: Philips/Bajaj).
Supplying, of 250w MH street light aesthetically designed die cast aluminium 250w metal halide lamp make(Philips).
Fixing testing and commissioning of Sodium vapour / Mercury vapour / Metal halide street light fittings on existing poles as required
Supply and fixing of wall mount bracket of 50 mm dia GI pipe suitable for SVL / MH fittings with clamp, bolts and nuts as required
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel , making connections, etc, as required - 63 A TP&N
Installation , testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FRLS PVC insulated , copper conductor , single core cable etc as required
Supplying and fixing following way , single pole and neutral , sheet steel , MCB distribution board , 240 V, on surface / recess , complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections , powder painted including earthing etc. as required (But without MCB / RCCB / Isolator) - 12 way , double door
Supplying and fixing 5 A to 32 A rating , 240/415 V, 10 kA, "C" curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc .as required. - Single Pole and Neutral
Supplying and fixing following rating, double pole , (single phase and neutral), 240V , residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections , testing and commissioning etc as required - 63 A
Supply and fixing of bracket of 25 mm dia GI pipe for 40 Watt single / double fitting tube street light with required bolt and nuts complete.
MKM Constructions
Civi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .