NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA,
SUMMARY OF COST
Sl. Description Scheduled Non Schedule
No. Amount Amount
(In Lacs.) (In Lacs.)
A BUILDING WORK
1 Repairment of School Buildings 3786520.29
2 Repairment of Kitchen & Dinning 1843911.90 93196.90
3 Repairment of Girls Dorm. (G+2) 3519778.03 133008.83
4 Repairment of Boys Dorm. 263494.00 28603.20
5 Repairment of Type IV Quarter 115233.10
6 Construcvtion of Surface Drain (450mm x 600mm 1529302.81
GRAND TOTAL: 11313049.05
GRAND TOTAL: 11313049.05
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
BILL OF QUANTITY FOR SCHOOL BUILDING
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
(I) STRUCTURE REPAIR & RETROFITTINGS
Expansion Joint Treatment
1 5.45 Providing and fixing of expansion joint system related with wall joint
(internal/ external) location as per drawings and direction of Engineer-In-
Charge. The joints shall be of extruded aluminum base members, self
aligning / centering arrangement and support plates as per ASTM B221- 02.
The material shall be such that it provides an Expansion Joints System
suitable for vertical wall to wall/ wall to corner application, both new and
existing construction in office Buildings & complexes with no slipping down
tendency amongst the components of the Joint System. The Joint System
shall utilize light weight aluminum profiles exhibiting minimal exposed
aluminum surfaces mechanically snap locking the multicellular to facilitate
movement. (Material shall confirm to ASTM 6063).
2 5.46 Providing and fixing of expansion joint system of approved make and
manufacture for various roof locations as per approved drawings and
direction of Engineer-In-Charge. The joints shall be of extruded aluminum
base members with, self aligning and self centering arragement support
plates as per ASTM B221-02. The system shall be such that it provides
water tight roof to roof /roof to corner joint cover expansion control system
that is capable of accommodating multidirectional seismic movement
without stress to its components. System shall consist of metal profile that
incorporates a universal aluminum base member designed to accommodate
various project conditions and roof treatments. The cover plate shall be
designed of width and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing manufacturer’s pre-
engineered self-centering arrangement that freely rotates / moves in all
directions. The Self centering arrangement shall exhibit circular sphere ends
that lock and slide inside the corresponding aluminum extrusion cavity to
allow freedom of movement and flexure in all directions including vertical
displacement. The Joint System shall resists damage or deterioration from
the impact of falling ice, exposure to UV, airborne contaminants and
occasional foot traffic from maintenance personnel. Provision of Moisture
Barrier Membrane in the Joint System to have water tight joint is mandatory
requirement. (Material shall confirm to ASTM 6063.)
TOTAL AMOUNT (STRUCTURE REPAIR & RETROFITTINGS): 3,05,556.58 -
TOTAL AMOUNT (STRUCTURE REPAIR & RETROFITTINGS): 3,05,556.58 -
(II) REPAIRS TO ROOF
3 14.91.1 Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 3 mm thick water proofing membrane, black finished
reinforced with non-woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the same membrane
manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps.
Over the primer coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the surface complete.
The vital physical and chemical parameters of the membrane shall be as
under : Joint strength in longitudinal and transverse direction at 23°C as
650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as
300/250N. Softening point of membrane not less than 150°C. Cold flexibility
shall be upto 2°C when tested in accordance with ASTM, D - 5147. The
laying of membrane shall be got done through the authorised applicator of
the manufacturer of membrane :
4 14.92 Extra for covering top of membrane with Geotextile, 120 gsm non woven,
100% polyester of thickness 1 to 1.25 mm bonded to the membrane with
intermittent touch by heating the membrane by Butane Torch as per
manufactures recommendation. 2996.79 Sqm 86.50 2,59,221.44
5 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) 202.69 Cum 7825.16 15,86,081.25
TOTAL AMOUNT (REPAIRS TO ROOF): 34,80,963.71 -
TOTAL AMOUNT (REPAIRS TO ROOF): 34,80,963.71 -
Grand Total Amount 37,86,520.29
Grand Total Amount 37,86,520.29
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
BILL OF QUANTITY FOR KITCHEN & DINING
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from slabs, beams,
columns etc. with manual Chisel and/ or by standard power driven
percussion type or of approved make including tapering of all edges,
making square shoulders of cavities including cleaning the exposed
concrete surface and reinforcement with wire brushes etc. and disposal
of debris for all lead and lifts all complete as per direction of Engineer-
A 26.28.2 50mm average thickness 9.00 Sqm 249.43 2,244.86
B 26.28.3 25 mm average thickness 4.50 Sqm 123.33 554.97
2 26.29 Cleaning of reinforcement from rust from the reinforcing bars to give it
a total rust free steel surface by using alkaline chemical rust remover of
approved make with paint brush and removing loose particles after 24
hours of its application with wire brush and thoroughly washing with
water and allowing it to dry, all complete as per direction of Engineer-In-
26.29.1 Bars upto 12 mm diameter 216.00 Mtr 8.03 1,733.89
3 26.37 Cleaning of exposed concrete surface of sticking material including
loose and foreign material by sand blasting with coarse sand followed
by and including cleaning with oil free air blast as per direction of
Engineer in charge. 46.89 Sqm 372.08 17,446.61
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in layers with
approved design mix concrete having the specified minimum
characteristic compressive strength [with ordinary portland cement,
coarse sand and graded stone aggregate of 10 mm maximum size in
proportion as per design criteria] including the cost of centering and
shuttering at edges and corners etc. as directed by Engineerin- Charge
Note: Rates shall include the providing necessary ground wires etc.
The levelling gauges, if used, shall be paid for separately. Payment
under this item shall be made only after proper wet curing has been
done and surface has been satisfactorily evaluated by sounding/
tapping with a blunt metal instrument.
A 26.38.1 25mm thick in Grade M 25 with cement content not less than 330 kg
B 26.38.2 50mm thick in Grade M 25 with cement content not less than 330 kg
Expansion Joint Treatment
5 5.45 Providing and fixing of expansion joint system related with wall joint
(internal/ external) location as per drawings and direction of Engineer-In-
Charge. The joints shall be of extruded aluminum base members, self
aligning / centering arrangement and support plates as per ASTM B221-
02. The material shall be such that it provides an Expansion Joints
System suitable for vertical wall to wall/ wall to corner application, both
new and existing construction in office Buildings & complexes with no
slipping down tendency amongst the components of the Joint System.
The Joint System shall utilize light weight aluminum profiles exhibiting
minimal exposed aluminum surfaces mechanically snap locking the
multicellular to facilitate movement. (Material shall confirm to ASTM
6 5.46 Providing and fixing of expansion joint system of approved make and
manufacture for various roof locations as per approved drawings and
direction of Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self centering
arragement support plates as per ASTM B221-02. The system shall be
such that it provides water tight roof to roof /roof to corner joint cover
expansion control system that is capable of accommodating
multidirectional seismic movement without stress to its components.
System shall consist of metal profile that incorporates a universal
aluminum base member designed to accommodate various project
conditions and roof treatments. The cover plate shall be designed of
width and thickness required to satisfy movement and loading
requirements and secured to base members by utilizing manufacturer’s
pre-engineered self-centering arrangement that freely rotates / moves
in all directions. The Self centering arrangement shall exhibit circular
sphere ends that lock and slide inside the corresponding aluminum
extrusion cavity to allow freedom of movement and flexure in all
directions including vertical displacement. The Joint System shall
resists damage or deterioration from the impact of falling ice, exposure
to UV, airborne contaminants and occasional foot traffic from
maintenance personnel. Provision of Moisture Barrier Membrane in the
Joint System to have water tight joint is mandatory requirement.
(Material shall confirm to ASTM 6063.)
SUB TOTAL 3,65,215.78 -
say in lacs 3.65 -
(ii) Repairs to Roof
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
7 14.91.1 Providing and laying APP (Atactic Polypropylene Polymer) modified
prefabricated five layer 3 mm thick water proofing membrane, black
finished reinforced with non-woven polyester matt consisting of a coat
of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same
membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and
viscocity 70-160 cps. Over the primer coat the layer of membrane shall
be laid using Butane Torch and sealing all joints etc, and preparing the
surface complete.
The vital physical and chemical parameters of the membrane shall be
as under : Joint strength in longitudinal and transverse direction at
23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse
direction as 300/250N. Softening point of membrane not less than
150°C. Cold flexibility shall be upto 2°C when tested in accordance with
ASTM, D - 5147. The laying of membrane shall be got done through
the authorised applicator of the manufacturer of membrane :
8 14.92 Extra for covering top of membrane with Geotextile, 120 gsm non
woven, 100% polyester of thickness 1 to 1.25 mm bonded to the
membrane with intermittent touch by heating the membrane by Butane
Torch as per manufactures recommendation. 663.42 Sqm 86.50 57,385.63
9 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20mm nominal size) 49.72 Cum 7825.16 3,89,066.85
10 Analysis Repairs to plaster of thickness 12 mm to 20 mm in patches with epoxy
based dampgaurd (Dr. Fixit Make) , including cutting the area of
plaster in proper shape, raking out joints and preparing and plastering
the surface of the walls complete, including disposal of rubbish to the
dumping ground, all complete as per direction of Engineer-in-
Charge.With cement mortar 1:4 (1cement: 4 coarse sand)
SUB TOTAL 8,41,793.64 -
say in lacs 8.42 -
(iii) Repair to Toilets
11 15.2 Demolishing cement concrete manually/ by mechanical means
including disposal of material within 50 metres lead as per direction of
Engineer - in - charge.
A 15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 0.38 Cum 2368.53 900.04
12 15.23 Dismantling tile work in floors and roofs laid in cement mortar including
stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm 41.16 Sqm 71.42 2,939.57
13 Analysis Providing and fixing Ist quality Glazed vitrified tiles polished finish of
size 600 x 600 mm tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved
by Engineer-in-Charge, in skirting, risers of steps and dados, over 12
mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm, including pointing in
white cement mixed with pigment of matching shade complete.
14 11.41A.3.1 Providing and laying Vitrified tiles in floor in different sizes (thickness to
be specified by the manufacturer) with water absorption less than
0.08% and conforming to IS:15622, of approved brand & manufacturer,
in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1
cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm
including grouting the joints with white cement and matching pigments
etc. The tiles must be cut with the zero chipping diamond cutter only .
Laying of tiles will be done with the notch trowel, plier, wedge, clips of
required thickness, leveling system and rubber mallet for placing the
tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size of
Tile 600 x 600 mm
1 15.42 Dismantling C.I. or asbestos rain water pipe with fittings and clamps
including stacking the material within 50 metres lead :
2 15.44 Dismantling G.I. pipes (external work) including excavation and refilling -
trenches after taking out the pipes, manually/ by mechanical means
including stacking of pipes within 50 metres lead as per direction of
Engineer-in-charge :
15.44.1 15 mm to 40 mm nominal bore 39.00 Mtr 145.76 5,684.46
3 15.45 Dismantling C.I. pipes including excavation and refilling trenches after -
taking out the pipes, manually/ by mechanical means breaking lead
caulked joints, melting of lead and making into blocks including
stacking of pipes & lead at site within 50 metre lead as per direction of
Engineer-in-charge:
4 15.48 Taking out C.I. cover with frame from R.C.C. top slab of manholes of 1,357.14
various sizes including demolishing of R.C.C. work manually/ by
mechanical means and stacking of useful materials near the site and
disposal of unserviceable materials within 50 metres lead as per
direction of Engineer-in-charge. 2.00 Each 678.57
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
5 15.51 Dismantling of road gully chamber of various sizes including C.I. grating 1,865.73
with frame including stacking of useful materials near the site and
disposal of unserviceable materials within 50 metres lead including
refilling the excavated gap. 2.00 Each 932.86
6 14.82 Dismantling W.C. Pan of all sizes including disposal of dismantled 391.44
materials i/c malba all complete as per directions of Engineer-in-
Charge. 3.00 Each 130.48
7 15.52 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) 327.07
including stacking of useful materials near the site and disposal of
unserviceable materials within 50 metres lead. 3.00 Each 109.02
8 15.53 Dismantling of C.I. sluice valve including stacking of useful materials -
within a lead of 50 metres
15.53.1 Up to 150 mm diameter 2.00 Each 310.87 621.75
9 19.24 Dismantling of manhole including R.C.C. top slab, C.I. cover with -
frame, including stacking of useful materials near the site and disposal
of unserviceable materials within 50 m lead as per direction of Engineer-
19.24.1 Rectangular manhole 90x80 cm and 45 cm deep 2.00 Each 2472.25 4,944.49
10 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain water -
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
11 12.42 Providing and fixing on wall face unplasticised - PVC moulded fittings/ -
accessories for unplasticised Rigid PVC rain water pipes conforming to
IS : 13592 Type A, including jointing with seal ring conforming to IS :
5382, leaving 10 mm gap for thermal expansion.
12.42.1.2 a) Coupler -
12 13.96 Painting (one or more coats) on rain water, soil, waste and vent pipes -
and fittings with synthetic enamel paint of approved brand and
manufacture and required colour on old work :
13.96.1 75 mm diameter pipes 3.00 Mtr 27.44 82.32
13.96.2 100 mm diameter pipes 3.00 Mtr 35.27 105.81
13 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) -
with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors
wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with 19,754.04
integral type foot rests 3.00 Each 6584.68
14 17.7 Providing & fixing white vitreous china wash basin with C.I. brackets -
painted white, 15mm C.P. brass pillar taps, C.P. brass chain with
rubber plug, 32mm C.P. brass waste of standard pattern including
cutting & making good the walls wherever required.
17.7.4 a) Flat back wash Basin size 550x400 mm with single 15mm C.P. 3,656.92
brass pillar tap. 2.00 Each 1828.46
15 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per -
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
wherever required :
17.10.2 Kitchen sink without drain board -
16 17.28 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin -
including PVC waste fittings complete.
17.28.2.1 a) 32mm dia (for wash basin) 2.00 Each 116.32 232.64
17.28.2.2 b) 40mm dia (for sink and urinal) 2.00 Each 116.32 232.64
17 MR Providing and fixing CP Brass soap dish 109 mm wide, 125 mm high
and 112 mm distance from wall of standard shape with bracket and all
fittings of the same material of approved quality and colour. 617.00
18 MR Providing & fixing C.P. Brass Waste Coupling for PVC waste Pipe.
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
19 Providing, fixing, jointing and testing in position of ISI marked UV
stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS :
13592 suitable for rubber ring joints, including all neccessary specials
and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or
without doors), reducers, WC connectors, couplers, expansion joints /
bellows, cowels, clamps, rubber rings, clean outs etc. fixing at wall/
ceiling/ floor level supported by clamp & hangers etc. in concealed /
inside duct / under floor & basement ceiling / external work etc.
including chase cutting as required, excavation and back filling in all
kind of soils, suspended from floor under false ceiling or embedding the
pipes laid under floors / building in 75 mm. alround 1:2:4 cement
concrete (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) including cost of shuttering for proper completion of the
work, breaking and making good the walls and floors etc. after pipes
have been duly laid and tested. The rubber ring shall confirm to
IS:5382.The Pipes will be supported with threaded G I rods & U clamps
with nuts, washers etc on 50x50x5 mm slotted angle. The cost will
include all support arrangements. The work includes commissioning of
all pipes lines as per drawings and specifications and as directed by
engg-in-charge at site.
MR 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 10.00 Mtr 750.00 7,500.00
MR 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 5.00 Mtr 550.00 2,750.00
20 Providing & fixing UPVC Floor trap of self cleansing design with
stainless steel grating complete in all respects.
MR Multi Floor Trap (5" Ht) with height raiser and branch saddle strip of
50/75 mm outlet 2.00 Each 673.00
MR Plain Floor Trap (4" Ht) with 50 / 75 outlet and with height raiser 4.00 Each 831.00 3,324.00
MR P-Trap type Floor Trap 110 x 75 mm 2.00 Each 565.00 1,130.00
21 MR Extra for providing & fixing 125 mm dia C.P. grating in place of C.I.
grating over floor traps. 8.00 Each 597.00
22 MR Providing & fixing of SS Floor Cleanout, round or square with rubber
seal and flat round cover with screws and other required fitting 1,167.00
complete as required. 3.00 Each 389.00
23 17.29 Providing and fixing 100 mm sand cast Iron grating for gully trap. 2.00 Each 51.81 103.62
24 17.35 Providing & fixing soil, waste and vent pipes. -
17.35.1.2 a) 100mm dia centrifugally cast iron S & S pipe. 3.00 Mtr 1148.87 3,446.61
17.35.2.2 b) 75mm dia centrifugally cast iron S & S pipe. 3.00 Mtr 1153.98 3,461.93
25 17.37 Providing & fixing M.S. holder bat clamps of approved design to sand -
cast iron/centrifugally cast (Spun) iron S & S pipe embeded in &
including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement
: 2 coarse : 4 graded stone aggregate 20mm nominal size). Including
cost of cutting holes & making good the walls etc.
26 17.38 Providing and fixing bend of required degree with access door, -
insertion rubber washer 3mm thick, bolts and nuts complete.
17.38.1.2 Sand cast iron S&S as per IS - 3989 1.00 Each 686.16 686.16
17.38.2.2 Sand cast iron S&S as per IS- 3989 1.00 Each 508.49 508.49
27 17.39 Providing and fixing plain cast iron S & S sanitary bend. -
17.39.1.1 Sand cast iron S&S as per IS - 1729 1.00 Each 457.75 457.75
17.39.2.2 Sand cast iron S&S as per IS - 3989 1.00 Each 379.96 379.96
28 17.43 Providing and fixing centrifugaly cast iron single equal plain junction of -
required degree.
29 17.56 Providing and fixing cast iron terminal guard. -
30 17.57 Providing & fixing cast iron coller. -
17.57.1.2 Sand cast iron S&S as per IS - 3989 1.00 Each 499.29 499.29
17.57.2.2 Sand cast iron S&S as per IS - 3989 1.00 Each 352.27 352.27
31 17.58 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) -
iron pipes & fitting of diameters.
32 17.60 Providing & fixing cast iron trap of self cleansing design with or without -
ventarm complete, including cost of cutting & making good the walls &
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
33 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, -
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with one step CPVC
solvent cement and the cost of cutting chases and making good the
same including testing of joints complete as per direction of Engineer in
18.8.1 15 mm nominal outer dia Pipes 55.00 Mtr 484.36 26,639.77
18.8.2 20 mm nominal outer dia Pipes 35.00 Mtr 523.08 18,307.97
18.8.3 25 mm nominal outer dia Pipes 25.00 Mtr 610.31 15,257.86
18.8.4 32 mm nominal outer dia Pipes 15.00 Mtr 719.34 10,790.08
34 18.16 Providing and fixing brass stop cock of approved quality. -
18.16.1 15 mm nominal bore 4.00 Each 343.71 1,374.85
35 18.17 Providing and fixing gun metal gate valve with wheel of approved -
18.17.1 a) 25mm dia nominal bore 4.00 Each 605.60 2,422.38
18.17.2 b) 32mm dia nominal bore 4.00 Each 670.98 2,683.92
36 18.18 Providing and fixing ball valve (brass) of approved quality complete. -
(High or low pressure with plastic floats).
18.18.3 a) 25mm. Nominal bore 4.00 Each 451.52 1,806.08
37 18.21 Providing and fixing 30 cm long unplasticised PVC connection pipe with -
18.21.1.1 a) 15mm nominal bore 2.00 Each 82.71 165.41
38 18.21 Providing and fixing 45 cm long unplasticised PVC connection pipe with -
18.21.2.1 a) 15mm nominal bore 2.00 Each 95.11 190.22
39 18.32 Constructing masonry Chamber 30x30x50 cm inside, in brick work in -
cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I.
surface box 100x100 x75 mm (inside) with hinged cover fixed in
cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size), i/c necessary excavation,
foundation 3concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone
aggregate 40mm nominal size ) and inside plastering with cement
mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a
floating coat of neat cement complete as per standard design :
18.32.1 With common burnt clay F.P.S.(non modular) bricks of class 3,877.60
designation 7.5 2.00 Each 1938.80
40 18.33 Constructing masonry Chamber 60x60x75 cm inside, in brick work in -
cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I.
surface box 100mm top diameter, 160 mm bottom diameter and 180
mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size
) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5
fine sand : 10 graded stone aggregate 40 mm nominal size) and inside
plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm
thick, finished with a floating coat of neat cement complete as per
standard design :
18.33.1 With common burnt clay F.P.S.(non modular) bricks of 10,569.12
class designation 7.5 1.00 Each 10569.12
41 18.49 Providing & fixing CP brass bib cock of approved quality conforming to -
18.49.1 a) 15mm nominal bore 26.00 Each 493.12 12,821.03
42 18.51 Providing & fixing C.P. brass long body bib cock of approved quality -
conforming to IS standards and weighing not less than 690 gms.
18.51.1 a) 15mm nominal bore 6.00 Each 777.38 4,664.27
43 18.53 Providing and fixing C.P. brass angle valve for basin mixer and geyser -
points of approved quality conforming to IS:8931
18.53.1 15mm nominal bore 5.00 Each 558.79 2,793.97
44 18.53A Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of 291.12
approved make and quality as per direction of Engineer-in-charge.
45 18.76 Cutting holes up to 30x30 cm in walls including making good the same: -
18.76.1 With common burnt clay F.P.S. (non modular) bricks 2.00 Each 405.55 811.09
46 18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing 1,759.18
drain pipe etc. and repairing the hole after insertion of drain pipe etc.
with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof. 4.00 Each 439.80
47 18.78 Making chases up to 7.5x7.5 cm in walls including making good and 7,896.87
finishing with matching surface after housing G.I. pipe etc. 40.00 Mtr 197.42
48 19.26 Raising manhole cover and frame slab to required level including -
dismantling existing slab and making good the damage as required
(Raising depth of manhole to be paid separately) :
19.26.1 Rectangular manhole 90x80 cm with rectangular cover 5,109.22
600 x 450 mm of grade LD - 2.5 2.00 Each 2554.61
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
49 14.75A Cleaning of terrace/loft water storage tank (inside surface area) upto 1,946.00
2000 litre capacity at all heights with coconut brushes, duster etc.,
removal of silt, rubbish from the tank and cleaning the tank with fresh
water disinfecting with bleaching powder @ 0.5gm per litre capacity of
tank including marking the date of cleaning on the side of tank body
with the help of stencil and paint and disposing of malba all complete
as per direction of Engineer-in-Charge. (The old date already written on
tank should be removed with paint remover or black paint and if date is
not written with the stencil or old date is not removed deduction will be
made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock
is damaged that is to be repaired by contractor at his own cost and
nothing extra will be paid on this account)
ELECTRICAL WORK OF KITCHEN & DINING
1 1.8 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5
sq.mm FR PVC insulated copper conductor single core cable in
surface / recessed medium class PVC conduit, with piano type switch,
phenolic laminated sheet, suitable size M.S. box and earthing the point
with 1.5 sq.mm. FR PVC insulated copper conductor single core cable
etc as required.
2 1.9 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface / recessed medium class
PVC conduit, 2 way piano type switch, phenolic laminated sheet,
suitable size MS box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc. as required.
3 1.12 Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper
conductor single core cable in surface/ recessed medium class PVC
conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor
single core cable for loop earthing as required. 10.00 Mtr 373.00 3,730.00
4 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following
sizes of FR PVC insulated copper conductor, single core cable in
surface/ recessed medium class PVC conduit as required
5 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FR PVC insulated copper conductor single core cable and
1.5 sq.mm. FR PVC insulated copper conductor single core cable as
earth wire in existing surface/ recessed steel conduit including
dismantling as required.
6 1.16 Rewiring for twin control light point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable and 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable as earth wire in
existing surface/ recessed steel/PVC conduit including dismantling as
required. 8.00 Point 1,064.00 8,512.00
7 1.17 Supplying and drawing following sizes of FR PVC insulated copper
conductor, single core cable in the existing surface/ recessed steel/
PVC conduit as required.
8 1.21 Supplying and fixing of following sizes of medium class PVC conduit
along with accessories in surface/recess including cutting the wall and
making good the same in case of recessed conduit as required.
9 1.22 Supplying and fixing metal box of following sizes (nominal size) on
surface or in recess with suitable size of phenolic laminated sheet
cover in front including painting etc. as required.
10 1.25 Supplying and fixing stepped type electronic fan regulator on the
existing modular plate switch box including connections but excluding
modular plate etc. as required. 14.00 Each 402.00 5,628.00
11 1.29 Supplying and fixing metal box of 150mm X 75mm X 60mm deep
(nominal size) on surface or in recess with suitable size of phenolic
laminated sheet cover in front including providing and fixing 3 pin 5/6
amps socket outlet and 5/6 amps piano type switch, connection,
painting etc. as required. (For light plugs to be used in non residential
buildings). 8.00 Each 423.00 3,384.00
12 1.30 Supplying and fixing metal box of 180mm X 100mm X 60mm deep
(nominal size) on surface or in recess with suitable size of phenolic
laminated sheet cover in front including providing and fixing 6 pin 5/6 &
15/16 amps socket outlet and 15/16 amps piano type switch,
connection, painting etc. as required. 8.00 Each 558.00 4,464.00
13 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction
box/ wooden block including connection etc as required. 6.00 Each 104.00 624.00
14 1.34 Supplying and fixing brass batten/ angle holder including connection
etc. as required. 10.00 Each 154.00 1,540.00
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Scheduled Non- Schedule
No. 2023 (In Rs.) Rate Amount Amount (In Rs.)
15 2.3 Supplying and fixing following way, single pole and neutral, sheet steel,
MCB distribution board, 240 volts, on surface/ recess, complete with
tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required.
(But without MCB/RCCB/Isolator)
16 2.4 Supplying and fixing following way, horizontal type three pole and
neutral, sheet steel, MCB distribution board, 415 volts, on surface/
recess, complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including earthing etc.
as required. (But without MCB/RCCB/Isolator)
17 2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C"
curve, miniature circuit breaker suitable for inductive load of following
poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
2.10.2 Single pole and neutral 2.00 Each 643.00 1,286.00
18 2.11 Supplying and fixing single pole blanking plate in the existing MCB DB
complete etc. as required. 4.00 Each 14.00 56.00
19 2.21 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm,
made of mild steel, at least 2 mm thick, and vitreous enameled white
on both sides, and with inscription in single red colour on front side as
required. 1.00 Each 315.00 315.00
20 1.41 Installation, testing and commissioning of pre-wired, fluorescent fitting /
compact fluorescent fitting of all types, complete with all accessories
and tube/lamp etc. directly on ceiling/ wall, including connections with
1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable
and earthing etc. as required. 37.00 Each 259.00 9,583.00
21 1.50 Installation of exhaust fan in the existing opening, including making
good the damage, connection, testing, commissioning etc. as required.
22 NSDR Supply of 15W SURFACE MOUNTED ROUND LED with all
accessories as per standard item.. 4.00 Each 1,587.10 1,587.10 6,348.40
23 NSDR Supply of 20W SURFACE MOUNTED ROUND LED with all
accessories as per standard item..(Such as Panasonic ADL04R206 or
24 NSDR Supply of 15W WALL BRACKET LED BULB with all accessories as
per standard item..(Such as Panasonic PBUM01157 or Equivalent).
25 NSDR Supply of 20W SURFACE MOUNTED LED TUBE with all accessories
as per standard item..(Such as Panasonic PBTM01207 or Equivalent).
26 NSDR 30W LED recess mounted fixture MAKE-PHILIPS CAT NO. RC380B
LED30S-6500 L60W60 PSD OD S1 or equivalent. 6.00 Each 4,200.80 4,200.80 25,204.80
27 9.2.4 Brush Less Direct Current (BLDC) Fan without
Supply, Installation, Testing and Commissioning of Ceiling fan with
Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.
metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,
shackle kit, safety rope, copper winding, steel/Al body Power Factor
not less than 0.9, Service Value (CM/M/W) minimum as below, 350
RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)
less than 10%, suitable for operation with regulator for speed control
and all remaining accessories including safety pin, nut bolts, washers,
temperature rise=75 0C (max.), insulation resistance more than 2
mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling
Fan compliant to IS 374:2019 fan i/c external connections with 1.5
sq.mm FRLS/HFFR, PVC insulated copper conductor single core
cable and earthing etc. as required.
1400mm, service value ≥ 6.0 CM/Min/Watt, air
delivery 245 CM/Min (Minimum)
28 NSDR Supply of AC 230/250 volts, 50 HZ exhaust fans including providing
nuts, bolts, mounting FRLSame and other accessories etc. complete
SAY IN LACS 2.61 0.64
Grand Total Amount 18,43,911.90 93,196.90
Grand Total Amount 18,43,911.90 93,196.90
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
BILL OF QUANTITY FOR GIRLS DORMITORY (G+2) 1 BLOCK FOR 96 STUDENTS
Sl. DSR- Description Qty Unit Scheduled Rate Non- Scheduled Non-
No. 2023 (In Rs.) Scheduled Amount Schedule
Rate (In Rs.) Amount (In
(i) Structural Repair & Retrofitting
1 26.28 Chipping of unsound/weak concrete material from
slabs, beams, columns etc. with manual Chisel and/ or
by standard power driven percussion type or of
approved make including tapering of all edges, making
square shoulders of cavities including cleaning the
exposed concrete surface and reinforcement with wire
brushes etc. and disposal of debris for all lead and lifts
all complete as per direction of Engineer-In-Charge
A 26.28.2 50 mm average thickness 4.20 Sqm 249.43 1,047.60
B 26.28.3 25 mm average thickness 6.00 Sqm 123.33 739.97
2 26.29 Cleaning of reinforcement from rust from the
reinforcing bars to give it a total rust free steel surface
by using alkaline chemical rust remover of approved
make with paint brush and removing loose particles
after 24 hours of its application with wire brush and
thoroughly washing with water and allowing it to dry, all
complete as per direction of Engineer-In-Charge.
26.29.1 Bars upto 12 mm diameter 163.20 Mtr 8.03 1,310.05
3 26.37 Cleaning of exposed concrete surface of sticking
material including loose and foreign material by sand
blasting with coarse sand followed by and including
cleaning with oil free air blast as per direction of
Engineer in charge. 4.20 Sqm 372.08 1,562.72
4 26.38 Shotcreting R.C.C. columns, beams and slabs etc. in
layers with approved design mix concrete having the
specified minimum characteristic compressive strength
[with ordinary portland cement, coarse sand and
graded stone aggregate of 10 mm maximum size in
proportion as per design criteria] including the cost of
centering and shuttering at edges and corners etc. as
directed by Engineerin- Charge
Note: Rates shall include the providing necessary
ground wires etc. The levelling gauges, if used, shall
be paid for separately. Payment under this item shall
be made only after proper wet curing has been done
and surface has been satisfactorily evaluated by
sounding/ tapping with a blunt metal instrument.
A 26.38.1 25mm thick in Grade M 25 with cement content not
less than 330 kg per cum 6.00 Sqm 726.73 4,360.40
B 26.38.2 50mm thick in Grade M 25 with cement content not
less than 330 kg per cum 4.20 Sqm 1119.97 4,703.88
5 MR Re-Baring of MS bar 10 mm dia with Fisher Chemical
including drilling of hole, cleaning, and fixing of bar
complete as per direction of Engineer-in-Charge.
Expansion Joint Treatment
Digitally signed by JAYA
6 5.44 Providing and fixing of expansion joint system related
with floor location as per drawings and direction of
Engineer-In-Charge. The joints system will be of
extruded aluminum base members, self aligning / self
centering arrangement and support plates etc. as per
ASTM B221-02. The system shall be such that it
provides floor to floor /floor to wall expansion control
system for various vertical localtion in load application
areas that accommodates multi directional seismic
movement without stress to it's components. System
shall consist of metal profiles with a universal
aluminum base member designed to accommodate
various project conditions and finish floor treatments.
The cover plate shall be designed of width and
thickness required to satisfy projects movement and
loading requirements and secured to base members by
utilizing manufacturer’s pre-engineered self- centering
arrangement that freely rotates / moves in all
directions. The Self - centering arrangement shall
exhibit circular sphere ends that lock and slide inside
the corresponding aluminum extrusion cavity to allow
freedom of movement and flexure in all directions
including vertical displacement. Provision of Moisture
Barrier Membrane in the Joint System to have
watertight joint is mandatory requirement all as per the
manufactures design and as approved by Engineer -in-
Charge. (Material shall confirm to ASTM 6063).
7 5.45 Providing and fixing of expansion joint system related
with wall joint (internal/ external) location as per
drawings and direction of Engineer-In- Charge. The
joints shall be of extruded aluminum base members,
self aligning / centering arrangement and support
plates as per ASTM B221- 02. The material shall be
such that it provides an Expansion Joints System
suitable for vertical wall to wall/ wall to corner
application, both new and existing construction in office
Buildings & complexes with no slipping down tendency
amongst the components of the Joint System. The
Joint System shall utilize light weight aluminum profiles
exhibiting minimal exposed aluminum surfaces
mechanically snap locking the multicellular to facilitate
movement. (Material shall confirm to ASTM 6063).
8 5.46 Providing and fixing of expansion joint system of
approved make and manufacture for various roof
locations as per approved drawings and direction of
Engineer-In-Charge. The joints shall be of extruded
aluminum base members with, self aligning and self
centering arragement support plates as per ASTM
B221-02. The system shall be such that it provides
water tight roof to roof /roof to corner joint cover
expansion control system that is capable of
accommodating multidirectional seismic movement
without stress to its components. System shall consist
of metal profile that incorporates a universal aluminum
base member designed to accommodate various
project conditions and roof treatments. The cover plate
shall be designed of width and thickness required to
satisfy movement and loading requirements and
secured to base members by utilizing manufacturer’s
pre-engineered self-centering arrangement that freely
rotates / moves in all directions. The Self centering
arrangement shall exhibit circular sphere ends that lock
and slide inside the corresponding aluminum extrusion
cavity to allow freedom of movement and flexure in all
directions including vertical displacement. The Joint
System shall resists damage or deterioration from the
impact of falling ice, exposure to UV, airborne
contaminants and occasional foot traffic from
maintenance personnel. Provision of Moisture Barrier
Membrane in the Joint System to have water tight joint
is mandatory requirement. (Material shall confirm to
(FOR 1 BLOCK): 3.34 0.08
Digitally signed by JAYA
(ii) Repairs to Roof
9 14.91.1 Providing and laying APP (Atactic Polypropylene
Polymer) modified prefabricated five layer 3 mm thick
water proofing membrane, black finished reinforced
with non-woven polyester matt consisting of a coat of
bitumen primer for bitumen membrane @ 0.40
litre/sqm by the same membrane manufacture of
density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160
cps. Over the primer coat the layer of membrane shall
be laid using Butane Torch and sealing all joints etc,
and preparing the surface complete. The vital physical
and chemical parameters of the membrane shall be as
under : Joint strength in longitudinal and transverse
direction at 23°C as 650/ 450N/ 5cm. Tear strength in
longitudinal and transverse direction as 300/250N.
Softening point of membrane not less than 150°C. Cold
flexibility shall be upto -2°C when tested in accordance
with ASTM, D - 5147. The laying of membrane shall be
got done through the authorised applicator of the
manufacturer of membrane : 3 mm thick
10 14.92 Extra for covering top of membrane with Geotextile,
120 gsm non woven, 100% polyester of thickness 1 to
1.25 mm bonded to the membrane with intermittent
touch by heating the membrane by Butane Torch as
per manufactures recommendation.
11 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 32.01 Cum 7825.16 2,50,483.30
SUB TOTAL 5,20,300.08 -
(FOR 1 BLOCK): 5.20 -
(iii) Repair to Toilets
1 15.23 Dismantling tile work in floors and roofs laid in cement
mortar including stacking material within 50 metres
15.23.1 For thickness of tiles 10 mm to 25 mm 479.02 Sqm 71.42 34,210.75
2 Analysis Providing and fixing Ist quality Glazed vitrified tiles
polished finish of size 600 x 600 mm tiles conforming
to IS: 15622 (thickness to be specified by the
manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any
size as approved by Engineer-in-Charge, in skirting,
risers of steps and dados, over 12 mm thick bed of
cement mortar 1:3 (1 cement : 3 coarse sand) and
jointing with grey cement slurry @ 3.3kg per sqm,
including pointing in white cement mixed with pigment
of matching shade complete.
3 11.41A.3.1 Providing and laying Vitrified tiles in floor in different
sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming
to IS:15622, of approved brand & manufacturer, in all
colours and shade, laid on 20 mm thick cement mortar
1:4 (1 cement: 4 coarse sand) jointing with grey
cement slurry @3.3 kg/sqm including grouting the
joints with white cement and matching pigments etc.
The tiles must be cut with the zero chipping diamond
cutter only . Laying of tiles will be done with the notch
trowel, plier, wedge, clips of required thickness,
leveling system and rubber mallet for placing the tiles
gently and easily.Glazed Vitrified tiles Matt/Antiskid
finish of size of Tile 600 x 600 mm
Digitally signed by JAYA
4 22.5 Providing and laying water proofing treatment in
sunken portion of WCs, bathroom etc., by applying
cement slurry mixed with water proofing cement
compound consisting of applying : a) First layer of
slurry of cement @ 0.488 kg/sqm mixed with water
proofing cement compound @ 0.253 kg/sqm. This
layer will be allowed to air cure for 4 hours. b) Second
layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm.
This layer will be allowed to air cure for 4 hours
followed with water curing for 48 hours. The rate
includes preparation of surface, treatment and sealing
of all joints, corners, junctions of pipes and masonry
with polymer mixed slurry. 116.72 SQM 600.39 70,077.48
5 MR Providing and filling of cinder in sunken portions. 16.03 CUM 2,374.40 38,061.63
6 15.56 Dismantling old plaster or skirting raking out joints and
cleaning the surface for plaster including disposal of
rubbish to the dumping ground within 50 metres lead.
7 13.5 15mm cement plaster on rough side of single or half
brick wall of mix
8 13.16 6mm cement plaster to ceiling of mix :
9 13.82 Wall painting with acrylic emulsion paint, having VOC
(Volatile Organic Compound) content less than 50
grams/ litre, of approved brand and manufacture,
including applying additional coats wherever required,
to achieve even shade and colour.
10 13.80 Providing and applying white cement based putty of
average thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete. 165.34 Sqm 151.84 25,104.67
11 15.12 Dismantling doors, windows and clerestory windows
(steel or wood) shutter including chowkhats, architrave,
holdfasts etc. complete and stacking within 50 metres
15.12.1 Of area 3 sq. metres and below 8.00 Each 357.29 2,858.28
12 15.13 Taking out doors, windows and clerestory window
shutters (steel or wood) including stacking within 50
15.13.1 Of area 3 sq. metres and below 10.00 Each 139.63 1,396.26
13 14.5 Renewing glass panes, with putty and nails wherever
including racking out the old putty: -
14.5.1 Float glass panes of nominal thickness 4 mm
(weight not less than 10kg/sqm) 1.35 Sqm 1061.20 1,432.62
14 14.9 Renewal of old putty of glass panes (length) 18.00 Mtr 54.63 983.41
15 9.48.1 Providing and fixing M.S. grills of required pattern in
frames of windows etc. with M.S. flats, square or round
bars etc. including priming coat with approved steel
primer all complete .Fixed to steel windows by welding
16 9.68 Providing and fixing oxidised M.S. casement stays
(straight peg type) with necessary screws etc. complete
9.68.1 300 mm weighing not less than 200gms. - Each 65.58 -
9.68.2 250 mm weighing not less than 150gms. 6.00 Each 59.40 356.41
17 9.70 Providing and fixing IS : 12817 marked stainless steel
butt hinges with stainless steel screws etc. complete :
18 9.165 Providing and fixing bright /matt finished Stainless
Steel handles of approved quality & make with
necessary screws etc all complete. (a) 125 mm.
Digitally signed by JAYA
19 8.2.2.1 Providing and fixing 18 mm thick gang saw cut, mirror
polished, premoulded and prepolished, machine cut for
kitchen platforms, vanity counters, window sills, facias
and similar locations of required size,approved shade,
colour and texture laid over 20 mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand), joints treated
with white cement, mixed with matching pigment,
epoxy touch ups, including rubbing, curing, moulding
and polishing to edges to give high gloss finish etc.
complete at all levels. Area of slab upto 0.50 sqm
20 9.122 Providing and fixing to existing door frames. -
9.122.2 30 mm thick Fiberglass Reinforced Plastic (F.R.P.)
flush door shutter in different plain and wood finish
made with fire retardant grade unsaturated polyester
resin, moulded to 3 mm thick FRP laminate all around,
with suitable wooden blocks inside at required places
for fixing of fittings and polyurethane foam PUF)/
Polystyrene foam to be used as filler material
throughout the hollow panel, casted monolithically with
testing parameters of F.R.P. laminate conforming to
table - 3 of IS: 14856, complete as per direction of
Engineer-in-charge.
21 10.11 Providing and fixing factory made ISI marked steel
glazed doors, windows and ventilators, side /top /centre
hung, with beading and all members such as F7D,
F4B, K11 B and K12 B etc. complete of standard rolled
steel sections, joints mitred and flash butt welded and
sash bars tenoned steel sections, joints mitred and
flash butt welded and sash bars tenoned and riveted,
including providing and fixing of hinges, pivots,
including priming coat of approved steel primer, but
excluding the cost of other fittings, complete all as per
approved design, (sectional weight of only fittings,
complete all as per approved design, (sectional weight
of only steel members shall be measured for payment).
10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6 (1
Cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size 77.76 Kg 127.51 9,915.31
22 10.15 Providing and fixing M.S. Tubular frames for doors,
windows, ventilators and cupboard with rectangular/ L-
Type sections, made of 1.60 mm thick M.S. Sheet,
joints mitred, welded and grinded finish, with profiles of
required size, including fixing of necessary butt hinges
and screws and applying a priming coat of approved
10.15.1 Fixing with 15x3 mm lugs 10 cm long embedded in
cement concrete block 15x10x10 cm of C.C. 1:3:6 (1
Cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size) 140.26 Kg 189.93 26,639.53
23 10.30 Providing & fixing glass panes with putty and glazing
clips in steel doors,windows, clerestory windows, all
10.30.1 4.0 mm thick glass panes 4.32 Sqm 1035.90 4,475.11
13.50 Applying priming coat :
24 13.50.3 With ready mixed red oxide zinc chromate primer of
approved brand and manufacture on steel galvanised
iron/ steel works 0.78 Sqm 65.58 51.15
25 13.61 Painting with synthetic enamel paint of approved brand
and manufacture of required colour to give an even
13.61.1 Two or more coats on new work 0.78 Sqm 151.69 118.32
1 15.42 Dismantling C.I. or asbestos rain water pipe with
fittings and clamps including stacking the material
within 50 metres lead :
2 15.44 Dismantling G.I. pipes (external work) including -
excavation and refilling trenches after taking out the
pipes, manually/ by mechanical means including
stacking of pipes within 50 metres lead as per direction
of Engineer-in-charge :
15.44.1 15 mm to 40 mm nominal bore 55.00 Mtr 145.76 8,016.55
Digitally signed by JAYA
3 15.45 Dismantling C.I. pipes including excavation and refilling -
trenches after taking out the pipes, manually/ by
mechanical means breaking lead caulked joints,
melting of lead and making into blocks including
stacking of pipes & lead at site within 50 metre lead as
per direction of Engineer-in-charge:
4 15.48 Taking out C.I. cover with frame from R.C.C. top slab 2,714.28
of manholes of various sizes including demolishing of
R.C.C. work manually/ by mechanical means and
stacking of useful materials near the site and disposal
of unserviceable materials within 50 metres lead as per
direction of Engineer-in-charge.
5 15.51 Dismantling of road gully chamber of various sizes 3,731.46
including C.I. grating with frame including stacking of
useful materials near the site and disposal of
unserviceable materials within 50 metres lead including
refilling the excavated gap. 4.00 Each 932.86
6 14.82 Dismantling W.C. Pan of all sizes including disposal of 2,609.59
dismantled materials i/c malba all complete as per
directions of Engineer-in- Charge. 20.00 Each 130.48
7 15.53 Dismantling of C.I. sluice valve including stacking of -
useful materials within a lead of 50 metres
15.53.1 Up to 150 mm diameter 5.00 Each 310.87 1,554.37
8 19.24 Dismantling of manhole including R.C.C. top slab, C.I. -
cover with frame, including stacking of useful materials
near the site and disposal of unserviceable materials
within 50 m lead as per direction of Engineer- charge :
19.24.1 Rectangular manhole 90x80 cm and 45 cm deep 2.00 Each 2472.25 4,944.49
9 12.41 Providing and fixing on wall face unplasticised Rigid -
PVC rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion, (i) Single
socketed pipes.
10 12.42 Providing and fixing on wall face unplasticised - PVC -
moulded fittings/ accessories for unplasticised Rigid
PVC rain water pipes conforming to IS : 13592 Type A,
including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
12.42.1.2 a) Coupler -
11 13.96 Painting (one or more coats) on rain water, soil, waste -
and vent pipes and fittings with synthetic enamel paint
of approved brand and manufacture and required
colour on old work :
13.96.1 75 mm diameter pipes 15.00 Mtr 27.44 411.58
13.96.2 100 mm diameter pipes 15.00 Mtr 35.27 529.07
12 17.1 Providing and fixing water closet squatting pan (Indian -
type W.C. pan ) with 100 mm sand cast Iron P or S
trap, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and making
good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C. pan of size 1,05,354.88
580x440 mm with integral type foot rests 16.00 Each 6584.68
13 17.2 Providing and fixing white vitreous china pedestal type -
water closet (European type W.C. pan) with seat and
lid, 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings
and fixtures complete, including cutting and making
good the walls and floors wherever required.
17.2.1 W.C. pan with ISI marked white solid plastic seat and 25,358.52
Digitally signed by JAYA
14 17.7 Providing & fixing white vitreous china wash basin with -
C.I. brackets painted white, 15mm C.P. brass pillar
taps, C.P. brass chain with rubber plug, 32mm C.P.
brass waste of standard pattern including cutting &
making good the walls wherever required.
17.7.4 a) Flat back wash Basin size 550x400 mm with single 3,656.92
15mm C.P. brass pillar tap. 2.00 Each 1828.46
15 17.23 Providing and fixing white vitreous china flat back or 12,835.43
wall corner type lipped front urinal basin of
430x260x350 mm or 340x410x265 mm sizes
respectively. 8.00 Each 1604.43
16 17.28 Providing and fixing flexible P.V.C. waste pipe for sink -
or wash basin including PVC waste fittings complete.
17.28.2.1 a) 32mm dia (for wash basin) 2.00 Each 116.32 232.64
17.28.2.2 b) 40mm dia (for sink and urinal) 8.00 Each 116.32 930.58
17 MR Providing & fixing C.P. Brass health faucet for ablution 7,324.00
with 1 meter long PVC tube, hand shower, couplings,
wall hook and other accessories. 4.00 Each 1831.00
18 MR Providing & fixing C.P. Brass Waste Coupling for PVC 20,760.00
waste Pipe. 12.00 Each 1730.00
19 Providing, fixing, jointing and testing in position of ISI -
marked UV stabilized UPVC pipes for soil, waste, and
vent, Type-B as per IS : 13592 suitable for rubber ring
joints, including all neccessary specials and fittings
(confirming to IS:14735) i.e. bends, tees, junctions
(with or without doors), reducers, WC connectors,
couplers, expansion joints / bellows, cowels, clamps,
rubber rings, clean outs etc. fixing at wall/ ceiling/ floor
level supported by clamp & hangers etc. in concealed /
inside duct / under floor & basement ceiling / external
work etc. including chase cutting as required,
excavation and back filling in all kind of soils,
suspended from floor under false ceiling or embedding
the pipes laid under floors / building in 75 mm. alround
1:2:4 cement concrete (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size) including
cost of shuttering for proper completion of the work,
breaking and making good the walls and floors etc.
after pipes have been duly laid and tested. The rubber
ring shall confirm to IS:5382.The Pipes will be
supported with threaded G I rods & U clamps with nuts,
washers etc on 50x50x5 mm slotted angle. The cost
will include all support arrangements. The work
includes commissioning of all pipes lines as per
drawings and specifications and as directed by engg-in-
charge at site.
MR 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) 15.00 Mtr 750.00 11,250.00
MR 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) 20.00 Mtr 550.00 11,000.00
20 Providing & fixing UPVC Floor trap of self cleansing -
design with stainless steel grating complete in all
MR Multi Floor Trap (5" Ht) with height raiser and branch 1,346.00
saddle strip of 50/75 mm outlet 2.00 Each 673.00
MR Plain Floor Trap (4" Ht) with 50 / 75 outlet and with 831.00
height raiser 1.00 Each 831.00
MR P-Trap type Floor Trap 110 x 75 mm 2.00 Each 565.00 1,130.00
21 MR Extra for providing & fixing 125 mm dia C.P. grating in 2,985.00
place of C.I. grating over floor traps. 5.00 Each 597.00
22 MR Providing & fixing of SS Floor Cleanout, round or
square with rubber seal and flat round cover with
screws and other required fitting complete as required.
Providing and fixing 100 mm sand cast Iron grating for 207.25
gully trap. 51.81
24 17.35 Providing & fixing soil, waste and vent pipes. -
17.35.1.2 a) 100mm dia centrifugally cast iron S & S pipe. 5.00 Mtr 1148.87 5,744.35
17.35.2.2 b) 75mm dia centrifugally cast iron S & S pipe. 5.00 Mtr 1153.98 5,769.89
Digitally signed by JAYA
25 17.37 Providing & fixing M.S. holder bat clamps of approved -
design to sand cast iron/centrifugally cast (Spun) iron S
& S pipe embeded in & including cement concrete
blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse :
4 graded stone aggregate 20mm nominal size).
Including cost of cutting holes & making good the walls
26 17.38 Providing and fixing bend of required degree with -
access door, insertion rubber washer 3mm thick, bolts
and nuts complete.
17.38.1.2 Sand cast iron S&S as per IS - 3989 2.00 Each 686.16 1,372.32
17.38.2.2 Sand cast iron S&S as per IS- 3989 2.00 Each 508.49 1,016.98
27 17.39 Providing and fixing plain cast iron S & S sanitary -
17.39.1.1 Sand cast iron S&S as per IS - 1729 2.00 Each 457.75 915.50
17.39.2.2 Sand cast iron S&S as per IS - 3989 2.00 Each 379.96 759.91
28 17.43 Providing and fixing centrifugaly cast iron single equal -
plain junction of required degree.
29 17.56 Providing and fixing cast iron terminal guard. -
30 17.57 Providing & fixing cast iron coller. -
17.57.1.2 Sand cast iron S&S as per IS - 3989 2.00 Each 499.29 998.59
17.57.2.2 Sand cast iron S&S as per IS - 3989 2.00 Each 352.27 704.55
31 17.58 Providing lead caulked joints to sand cast -
iron/centrifugally cast (spun) iron pipes & fitting of
32 17.60 Providing & fixing cast iron trap of self cleansing design -
with or without ventarm complete, including cost of
cutting & making good the walls & floors.
33 17.75 Providing and fixing PTMT 15 mm Urinal spreader size 834.44
95x69x100 mm with 1/2" BSP thread and shapes,
weighing not less than 60 gms. 8.00 Each 104.31
34 17.76 Providing and fixing PTMT urinal cock of approved -
quality and colour.
17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and 1,365.31
30mm wide with BSP female threads weighing not less
than 48 gms 8.00 Each 170.66
35 18.8 Providing and fixing Chlorinated Polyvinyl Chloride -
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass
threaded fittings, i/c fixing the pipe with clamps at 1.00
m spacing. This includes jointing of pipes & fittings with
one step CPVC solvent cement and the cost of cutting
chases and making good the same including testing of
joints complete as per direction of Engineer in Charge.
18.8.1 15 mm nominal outer dia Pipes 55.00 Mtr 484.36 26,639.77
18.8.2 20 mm nominal outer dia Pipes 45.00 Mtr 523.08 23,538.82
18.8.3 25 mm nominal outer dia Pipes 35.00 Mtr 610.31 21,361.00
18.8.4 32 mm nominal outer dia Pipes 25.00 Mtr 719.34 17,983.47
36 18.16 Providing and fixing brass stop cock of approved -
37 18.17 Providing and fixing gun metal gate valve with wheel of -
approved quality.
18.17.1 a) 25mm dia nominal bore 4.00 Each 605.60 2,422.38
18.17.2 b) 32mm dia nominal bore 4.00 Each 670.98 2,683.92
Digitally signed by JAYA
38 18.18 Providing and fixing ball valve (brass) of approved -
quality complete. (High or low pressure with plastic
18.18.3 a) 25mm. Nominal bore 4.00 Each 451.52 1,806.08
39 18.21 Providing and fixing 30 cm long unplasticised PVC -
connection pipe with brass unions.
18.21.1.1 a) 15mm nominal bore 4.00 Each 82.71 330.82
40 18.21 Providing and fixing 45 cm long unplasticised PVC -
connection pipe with brass unions.
18.21.2.1 a) 15mm nominal bore 4.00 Each 95.11 380.44
41 18.48 Providing and placing on terrace (at all floor levels) 1,07,030.00
polyethylene water storage tank of approved brand and
manufacture with cover and suitable locking
arrangement and making necessary holes for inlet,
outlet and overflow pipes but without fittings and the
base support for tank. 10000.00 Ltr 10.70
42 18.49 Providing & fixing CP brass bib cock of approved -
quality conforming to IS 8931
18.49.1 a) 15mm nominal bore 20.00 Each 493.12 9,862.33
43 18.51 Providing & fixing C.P. brass long body bib cock of -
approved quality conforming to IS standards and
weighing not less than 690 gms.
18.51.1 a) 15mm nominal bore 1.00 Each 777.38 777.38
44 18.53 Providing and fixing C.P. brass angle valve for basin -
mixer and geyser points of approved quality conforming
18.53.1 15mm nominal bore 2.00 Each 558.79 1,117.59
45 18.53A Providing and fixing C.P. Brass extension nipple (size 145.56
15mmx50mm) of approved make and quality as per
direction of Engineer-in-charge. 2.00 Each 72.78
46 18.75 Providing and fixing PTMT extension nipple for water -
tank pipe, fittings of approved quality and colour.
18.75.3 25mm nominal bore, weighing not less than 62 gms 220.58
47 18.76 Cutting holes up to 30x30 cm in walls including making -
18.76.1 With common burnt clay F.P.S. (non modular) bricks 1,622.19
48 18.77 Cutting holes up to 15x15 cm in R.C.C. floors and roofs 1,759.18
for passing drain pipe etc. and repairing the hole after
insertion of drain pipe etc. with cement concrete 1:2:4
(1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size), including finishing complete so
as to make it leak proof.
49 18.78 Making chases up to 7.5x7.5 cm in walls including 4,935.54
making good and finishing with matching surface after
housing G.I. pipe etc. 25.00 Mtr 197.42
Say (In Lacs): 24.02 0.96
ELECTRICAL WORKS
1 1.8 Wiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FR PVC insulated copper
conductor single core cable in surface / recessed
medium class PVC conduit, with piano type switch,
phenolic laminated sheet, suitable size M.S. box and
earthing the point with 1.5 sq.mm. FR PVC insulated
copper conductor single core cable etc as required.
2 1.9 Wiring for twin control light point with 1.5 sq.mm FRLS
PVC insulated copper conductor single core cable in
surface / recessed medium class PVC conduit, 2 way
piano type switch, phenolic laminated sheet, suitable
size MS box and earthing the point with 1.5 sq.mm.
FRLS PVC insulated copper conductor single core
cable etc. as required.
Digitally signed by JAYA
3 1.12 Wiring for light/ power plug with 2X4 sq. mm FR PVC
insulated copper conductor single core cable in
surface/ recessed medium class PVC conduit
alongwith 1 No 4 sq. mm FR PVC insulated copper
conductor single core cable for loop earthing as
4 1.14 Wiring for circuit/ submain wiring alongwith earth wire
with the following sizes of FR PVC insulated copper
conductor, single core cable in surface/ recessed
medium class PVC conduit as required
5 1.15 Rewiring for light point/ fan point/ exhaust fan point/ call
bell point with 1.5 sq.mm FR PVC insulated copper
conductor single core cable and 1.5 sq.mm. FR PVC
insulated copper conductor single core cable as earth
wire in existing surface/ recessed steel conduit
including dismantling as required.
6 1.16 Rewiring for twin control light point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core
cable and 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable as earth wire in existing
surface/ recessed steel/PVC conduit including
dismantling as required. 4.00 Point 1,064.00 4,256.00
7 1.17 Supplying and drawing following sizes of FR PVC
insulated copper conductor, single core cable in the
existing surface/ recessed steel/ PVC conduit as
8 1.21 Supplying and fixing of following sizes of medium class
PVC conduit along with accessories in surface/recess
including cutting the wall and making good the same in
case of recessed conduit as required.
9 1.22 Supplying and fixing metal box of following sizes
(nominal size) on surface or in recess with suitable size
of phenolic laminated sheet cover in front including
painting etc. as required.
10 1.25 Supplying and fixing stepped type electronic fan
regulator on the existing modular plate switch box
including connections but excluding modular plate etc.
as required. 6.00 Each 402.00 2,412.00
11 1.29 Supplying and fixing metal box of 150mm X 75mm X
60mm deep (nominal size) on surface or in recess with
suitable size of phenolic laminated sheet cover in front
including providing and fixing 3 pin 5/6 amps socket
outlet and 5/6 amps piano type switch, connection,
painting etc. as required. (For light plugs to be used in
non residential buildings).
12 1.30 Supplying and fixing metal box of 180mm X 100mm X
60mm deep (nominal size) on surface or in recess with
suitable size of phenolic laminated sheet cover in front
including providing and fixing 6 pin 5/6 & 15/16 amps
socket outlet and 15/16 amps piano type switch,
connection, painting etc. as required.
13 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the
existing junction box/ wooden block including
connection etc as required. 20.00 Each 104.00 2,080.00
14 1.34 Supplying and fixing brass batten/ angle holder
including connection etc. as required. 15.00 Each 154.00 2,310.00
15 1.38 Supplying and fixing call bell/ buzzer suitable for single
phase, 230 volts, complete as required. 2.00 Each 112.00 224.00
Digitally signed by JAYA
16 2.3 Supplying and fixing following way, single pole and
neutral, sheet steel, MCB distribution board, 240 volts,
on surface/ recess, complete with tinned copper bus
bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
17 2.4 Supplying and fixing following way, horizontal type
three pole and neutral, sheet steel, MCB distribution
board, 415 volts, on surface/ recess, complete with
tinned copper bus bar, neutral bus bar, earth bar, din
bar, interconnections, powder painted including
earthing etc. as required. (But without
MCB/RCCB/Isolator)
18 2.10 Supplying and fixing 5 amps to 32 amps rating,
240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the
existing MCB DB complete with connections, testing
and commissioning etc. as required.
2.10.2 Single pole and neutral 6.00 Each 643.00 3,858.00
19 2.11 Supplying and fixing single pole blanking plate in the
existing MCB DB complete etc. as required. 10.00 Each 14.00 140.00
20 2.21 Providing and fixing M.V. danger notice plate of 200
mm X 150 mm, made of mild steel, at least 2 mm thick,
and vitreous enameled white on both sides, and with
inscription in single red colour on front side as required.
21 1.41 Installation, testing and commissioning of pre-wired,
fluorescent fitting / compact fluorescent fitting of all
types, complete with all accessories and tube/lamp etc.
directly on ceiling/ wall, including connections with 1.5
sq. mm FRLS PVC insulated, copper conductor, single
core cable and earthing etc. as required.
22 NSDR Supply of 15W SURFACE MOUNTED ROUND LED
with all accessories as per standard item.. 5.00 Each 1,587.10 7,935.50
23 NSDR Supply of 20W SURFACE MOUNTED ROUND LED
with all accessories as per standard item..(Such as
Panasonic ADL04R206 or Equivalent).
24 NSDR Supply of 15W WALL BRACKET LED BULB with all
accessories as per standard item..(Such as Panasonic
PBUM01157 or Equivalent). 10.00 Each 446.04 4,460.40
25 NSDR Supply of 20W SURFACE MOUNTED LED TUBE with
all accessories as per standard item..(Such as
Panasonic PBTM01207 or Equivalent). 10.00 Each 1,058.46 10,584.60
26 9.2.3 Brush Less Direct Current (BLDC) Fan without
Supply, Installation, Testing and Commissioning of
ceiling fan with Brush Less Direct Current (BLDC)
Motor, class of insulation: B, 3 nos. metal( Aluminium
alloy) blades, 30 cm long down rod, 2 nos. canopies,
shackle kit, safety rope, copper winding, steel/Al body
Power Factor not less than 0.9, Service Value
(CM/M/W) minimum as below, 350 RPM (tolerance as
per IS : 374-2019), THD (Total Harmonic Distortion)
less than 10%, suitable for operation with regulator for
speed control and all remaining accessories including
safety pin, nut bolts, washers, temperature rise=75 0C
(max.), insulation resistance more than 2 mega ohm,
suitable for 230 V, 50 Hz, single phase AC supply,
Ceiling Fan compliant to IS 374:2019 fan i/c external
connections with 1.5 sq.mm FRLS/HFFR, PVC
insulated copper conductor single core cable
and earthing etc. as required.
(FOR 1 BLOCK): 2.63 0.29
Say (In Lacs): 35.20 1.33
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
ELECTRICAL WORK OF BOYS DORMITORY
Sl. DSR- Description Qty Unit Scheduled Non- Scheduled Non-
No. 2025 Rate Scheduled Amount Schedule
(In Rs.) Rate (In Rs.) Amount (In
1 1.8 Wiring for light point/ fan point/ exhaust fan point/
call bell point with 1.5 sq.mm FR PVC insulated
copper conductor single core cable in surface /
recessed medium class PVC conduit, with piano
type switch, phenolic laminated sheet, suitable size
M.S. box and earthing the point with 1.5 sq.mm. FR
PVC insulated copper conductor single core cable
etc as required.
2 1.9 Wiring for twin control light point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core
cable in surface / recessed medium class PVC
conduit, 2 way piano type switch, phenolic
laminated sheet, suitable size MS box and earthing
the point with 1.5 sq.mm. FRLS PVC insulated
copper conductor single core cable etc. as required.
3 1.12 Wiring for light/ power plug with 2X4 sq. mm FR
PVC insulated copper conductor single core cable
in surface/ recessed medium class PVC conduit
alongwith 1 No 4 sq. mm FR PVC insulated copper
conductor single core cable for loop earthing as
4 1.14 Wiring for circuit/ submain wiring alongwith earth
wire with the following sizes of FR PVC insulated
copper conductor, single core cable in surface/
recessed medium class PVC conduit as required
5 1.15 Rewiring for light point/ fan point/ exhaust fan point/
call bell point with 1.5 sq.mm FR PVC insulated
copper conductor single core cable and 1.5 sq.mm.
FR PVC insulated copper conductor single core
cable as earth wire in existing surface/ recessed
steel conduit including dismantling as required.
6 1.16 Rewiring for twin control light point with 1.5 sq.mm
FRLS PVC insulated copper conductor single core
cable and 1.5 sq.mm FRLS PVC insulated copper
conductor single core cable as earth wire in existing
surface/ recessed steel/PVC conduit including
dismantling as required.
7 1.17 Supplying and drawing following sizes of FR PVC
insulated copper conductor, single core cable in the
existing surface/ recessed steel/ PVC conduit as
8 1.21 Supplying and fixing of following sizes of medium
class PVC conduit along with accessories in
surface/recess including cutting the wall and
making good the same in case of recessed conduit
9 1.22 Supplying and fixing metal box of following sizes
(nominal size) on surface or in recess with suitable
size of phenolic laminated sheet cover in front
including painting etc. as required.
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Non- Scheduled Non-
No. 2025 Rate Scheduled Amount Schedule
(In Rs.) Rate (In Rs.) Amount (In
10 1.25 Supplying and fixing stepped type electronic fan
regulator on the existing modular plate switch box
including connections but excluding modular plate
etc. as required. 6.00 Each 402.00 2,412.00
11 1.29 Supplying and fixing metal box of 150mm X 75mm
X 60mm deep (nominal size) on surface or in
recess with suitable size of phenolic laminated
sheet cover in front including providing and fixing 3
pin 5/6 amps socket outlet and 5/6 amps piano type
switch, connection, painting etc. as required. (For
light plugs to be used in non residential buildings).
12 1.30 Supplying and fixing metal box of 180mm X 100mm
X 60mm deep (nominal size) on surface or in
recess with suitable size of phenolic laminated
sheet cover in front including providing and fixing 6
pin 5/6 & 15/16 amps socket outlet and 15/16 amps
piano type switch, connection, painting etc. as
required. 5.00 Each 558.00 2,790.00
13 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on
the existing junction box/ wooden block including
connection etc as required. 20.00 Each 104.00 2,080.00
14 1.34 Supplying and fixing brass batten/ angle holder
including connection etc. as required. 15.00 Each 154.00 2,310.00
15 1.38 Supplying and fixing call bell/ buzzer suitable for
single phase, 230 volts, complete as required. 2.00 Each 112.00 224.00
16 2.3 Supplying and fixing following way, single pole and
neutral, sheet steel, MCB distribution board, 240
volts, on surface/ recess, complete with tinned
copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing
etc. as required. (But without MCB/RCCB/Isolator)
17 2.4 Supplying and fixing following way, horizontal type
three pole and neutral, sheet steel, MCB
distribution board, 415 volts, on surface/ recess,
complete with tinned copper bus bar, neutral bus
bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But
without MCB/RCCB/Isolator)
18 2.10 Supplying and fixing 5 amps to 32 amps rating,
240/415 volts, "C" curve, miniature circuit breaker
suitable for inductive load of following poles in the
existing MCB DB complete with connections,
testing and commissioning etc. as required.
2.10.2 Single pole and neutral 6.00 Each 643.00 3,858.00
19 2.11 Supplying and fixing single pole blanking plate in
the existing MCB DB complete etc. as required. 10.00 Each 14.00 140.00
20 2.21 Providing and fixing M.V. danger notice plate of 200
mm X 150 mm, made of mild steel, at least 2 mm
thick, and vitreous enameled white on both sides,
and with inscription in single red colour on front side
as required. 1.00 Each 315.00 315.00
Digitally signed by JAYA
Sl. DSR- Description Qty Unit Scheduled Non- Scheduled Non-
No. 2025 Rate Scheduled Amount Schedule
(In Rs.) Rate (In Rs.) Amount (In
21 1.41 Installation, testing and commissioning of pre-wired,
fluorescent fitting / compact fluorescent fitting of all
types, complete with all accessories and tube/lamp
etc. directly on ceiling/ wall, including connections
with 1.5 sq. mm FRLS PVC insulated, copper
conductor, single core cable and earthing etc. as
required. 30.00 Each 259.00 7,770.00
22 NSDR Supply of 15W SURFACE MOUNTED ROUND LED
with all accessories as per standard item.. 5.00 Each 1,587.10 7,935.50
23 NSDR Supply of 20W SURFACE MOUNTED ROUND LED
with all accessories as per standard item..(Such as
Panasonic ADL04R206 or Equivalent).
24 NSDR Supply of 15W WALL BRACKET LED BULB with all
accessories as per standard item..(Such as
Panasonic PBUM01157 or Equivalent). 10.00 Each 446.04 4,460.40
25 NSDR Supply of 20W SURFACE MOUNTED LED TUBE
with all accessories as per standard item..(Such as
Panasonic PBTM01207 or Equivalent).
26 9.2.3 Brush Less Direct Current (BLDC) Fan without
Supply, Installation, Testing and Commissioning of
ceiling fan with Brush Less Direct Current (BLDC)
Motor, class of insulation: B, 3 nos. metal(
Aluminium alloy) blades, 30 cm long down rod, 2
nos. canopies, shackle kit, safety rope, copper
winding, steel/Al body Power Factor not less than
0.9, Service Value (CM/M/W) minimum as below,
350 RPM (tolerance as per IS : 374-2019), THD
(Total Harmonic Distortion) less than 10%, suitable
for operation with regulator for speed control and
all remaining accessories including safety pin, nut
bolts, washers, temperature rise=75 0C (max.),
insulation resistance more than 2 mega ohm,
suitable for 230 V, 50 Hz, single phase AC supply,
Ceiling Fan compliant to IS 374:2019 fan i/c
external connections with 1.5 sq.mm FRLS/HFFR,
PVC insulated copper conductor single core cable
and earthing etc. as required.
(FOR 1 BLOCK): 2.63 0.29
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
BILL OF QUANTITY FOR TYPE - 4 STAFF QUARTER
Sl. DSR- Description Qty Unit Scheduled Non-Scheduled Scheduled Non- Schedule
No. 2023 Rate Rate Amount Amount (In Rs.)
(ii) Repairs to Roof
1 14.91.1 Providing and laying APP (Atactic Polypropylene Polymer)
modified prefabricated five layer 3 mm thick water
proofing membrane, black finished reinforced with non-
woven polyester matt consisting of a coat of bitumen
primer for bitumen membrane @ 0.40 litre/sqm by the
same membrane manufacture of density at 25°C, 0.87-
0.89 kg/ litre and viscocity 70-160 cps. Over the primer
coat the layer of membrane shall be laid using Butane
Torch and sealing all joints etc, and preparing the surface
The vital physical and chemical parameters of the
membrane shall be as under : Joint strength in longitudinal
and transverse direction at 23°C as 650/ 450N/ 5cm. Tear
strength in longitudinal and transverse direction as
300/250N. Softening point of membrane not less than
150°C. Cold flexibility shall be upto -2°C when tested in
accordance with ASTM, D - 5147. The laying of
membrane shall be got done through the authorised
applicator of the manufacturer of membrane :
2 14.92 Extra for covering top of membrane with Geotextile, 120
gsm non woven, 100% polyester of thickness 1 to 1.25
mm bonded to the membrane with intermittent touch by
heating the membrane by Butane Torch as per
manufactures recommendation. 94.50 Sqm 86.50 8,174.22
3 22.14.1 Grading roof for water proofing treatment with
Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20mm nominal size) 7.09 Cum 7825.16 55,480.37
SUB TOTAL: 1,15,233.10 -
Say (In Lacs): 1.15 -
Digitally signed by JAYA
NAME OF WORK :- SPECIAL REPAIR & MAINTENANCE WORK AT JNV RAYAGADA, ODISHA.
BILL OF QUANTITY FOR 450 X 600 MM WIDE R.C.C. DRAINS
Sl. DSR- Description Qty Unit Scheduled Rate Non-Scheduled Rate Scheduled Amount Non- Schedule
No. 2023 (In Rs.) (In Rs.) (In Rs.) Amount (In Rs.)
1 Earth work in excavation by mechanical means
(Hydraulic excavator)/ manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well
as 10 sqm on plan) including getting out and
disposal of excavated earth lead upto 50 m and lift
upto 1.5 m, as directed by Engineer-incharge.
All kinds of soil
2 Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers
not exceeding 20cm in depth, consolidating each
deposited layer by ramming and watering, lead up
to 50 m and lift upto 1.5 m.
3 Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) derived
from natural sources : 8 graded stone aggregate
40 mm nominal size derived from natural sources)
4 Providing and laying in position ready mixed or site
batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate
and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland
Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard
setting of concrete, to improve durability and
workability without impairing strength; including
pumping of concrete to site of laying, curing,
carriage for all leads; but excluding the cost of
centering, shuttering, finishing and reinforcement
as per direction of the engineer-in-charge; for the
following grades of concrete Note: Extra cement
up to 10% of the minimum specified cement
content in design mix shall be payable separately.
In case the cement content in design mix is more
than 110% of the specified minimum cement
content, the contractor shall have discretion to
either re-design the mix or bear the cost of extra
cement. Concrete of M25 grade with minimum
content of 330 kg /cum
5 Steel reinforcement for R.C.C. work including
straightening, cutting, bending, placing in position
and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-
Centering and shuttering including strutting,
6 propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for
Walls (any thickness) including attached pilasters,
(ii) 5.9.2 butteresses, plinth and string courses etc. 144 Sqm 819.7525 118044.36
Say (In Lacs): 15.29 -
Digitally signed by JAYA
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
GCC_PMC_Contracting_2022 with amendment-16.pdf
Tender Document
SCC.pdf
Tender Document
BOQ.pdf
Tender Document
Technical Specification.pdf
Tender Document
List of Approved Makes.pdf
Tender Document
Technical Circular_31.pdf
Tender Document
Milestone.pdf
Tender Document
corrigendum-4829-Corrigendum02.pdf
pdf • 0.09 MB
corrigendum-4809-Corrigendum01.pdf
pdf • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .