Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹37.0 LAccepted-AOC | ₹37.0 L | L-1 | Accepted-AOC CWC-I decided on 25.05.2026, it is decided to award the contract on M/s. Ramesh Yadav, Siwan, as per terms and conditions laid down in tender and contract. |
| 2 | L-2₹41.0 L+₹4.0 L (10.8%)Rejected-Finance | ₹41.0 L+₹4.0 L (10.8%) | L-2 | Rejected-Finance As per CWC-I Decision dated 25.05.2026 |
| 3 | L-3₹46.4 L+₹9.4 L (25.5%)Rejected-Finance | ₹46.4 L+₹9.4 L (25.5%) | L-3 | Rejected-Finance As per CWC-I Decision dated 25.05.2026 |
| 4 | L-4₹55.4 L+₹18.4 L (49.9%)Rejected-Finance 0 NEELAM ENTERPRISES MAIN ROAD BIJAPUR FRONT OF PAMBHOI PETROL PUMP BIJAPUR CHHATTISGARH 494444 | RAIPUR | CHHATTISGARH | 494444 | ₹55.4 L+₹18.4 L (49.9%) | L-4 | Rejected-Finance As per CWC-I Decision dated 25.05.2026 |
| Sl No | Description | Qty | Unit | RAMESH YADAV L1 | ANUBHAV AND CO L3 | M/s S.D.WAGHAMSHI L2 | M/S NEELAM ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old existing treatment (tarfelt) including cement or cement lime plaster, screed bed, loose concrete ete. any description all as directed by E-I-C. | 6,452 | SQM | 20 ₹1,29,040 Lowest | 50 ₹3,22,600 | 30 ₹1,93,560 | 50 ₹3,22,600 |
| 2.00 | M&L for brushing neat cement slurry with 3.00 kg of cement per sq. meter. Specification for cement used:-Make: ACC, Lafarge, Ultratech or equivalent. Test Certificate of cement is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.3 of MES SSR 2009 Part-1. | 6,452 | SQM | 15 ₹96,780 Lowest | 40 ₹2,58,080 | 20 ₹1,29,040 | 40 ₹2,58,080 |
| 3.00 | M&L, for 15mm thick plaster in cement mortar 1:4 mixed with water proofing compound @2% by weight of cement over roof slab, cement plaster laid in slope all as directed by E-I-C. Make –ACC, Lafarge, Ultratech or equivalent. Test Certificate of cement is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.3 of MES SSR 2009 Part-1. | 6,452 | SQM | 145 ₹9,35,540 Lowest | 175 ₹11,29,100 | 180 ₹11,61,360 | 190 ₹12,25,880 |
| 4.00 | Supply only integral water proofing compound, as approved by E-I-C before use in the work. Make-STP, IWL, Dr. Fixit or equivalent. Test Certificate/QAC of WPC is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.8 of MES SSR 2009 Part-1. | 740 | KG | 30 ₹22,200 Lowest | 70 ₹51,800 | 150 ₹1,11,000 | 85 ₹62,900 |
| 5.00 | M&L for APP modified membrane water proofing treatment on the roof slab as specified.
(a) The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign material & dust to receive primer.
(b) On the dried roof surface apply a uniform coat of bitumen primer @ 0.40 liter/sqm till the surface properly impregnated.
(c) On this primed surface, applying one coat of hot blown bitumen 85/25 grade @1.20kg/sqm over the entire surfaces and then providing a layer of App based of polymeric membrane (Make-STP/IWL/Asianpaints or equivalent ) weighing 3.0 kg/sqm and minimum 3mm thick.
(d) After laying APP membrane , applying a coat of hot blown bitumen of 85/25 grade @1.20 kg/sqm.
(e) The overlap between membrane joints shall be 75mm on longitudinal direction and 100mm on transverse direction.
(f) Top most layer of surface finish shall be with EMA paint @ 0.50kg/sqm.
Test Certificate of Cement and APP membrane is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 11.43 and their sub clause of MES SSR 2009 Part-1. | 6,452 | SQM | 385 ₹24,84,020 | 410 ₹26,45,320 | 380 ₹24,51,760 Lowest | 520 ₹33,55,040 |
| 6.00 | Supply & fixing rough cast wired glass exe. 1.00 sqm but n.exe. 1.50 sqm, 6.40mm thick and glazing with oil putty in square for north light glass all as per specifications and as directed by E-I-C. | 12 | SQM | 500 ₹6,000 Lowest | 1,100 ₹13,200 | 500 ₹6,000 Lowest | 1,200 ₹14,400 |
| 7.00 | Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning and refixing complete with all fitting or removal to store, all as specified and directed by Engineer In Charge. | 385 | RM | 20 ₹7,700 Lowest | 350 ₹1,34,750 | 30 ₹11,550 | 450 ₹1,73,250 |
| 8.00 | Trimming of tree branches over hanging over roofs etc. including shifting of debris/ branches etc. at suitable place or as directed. | 29 | Each Tree | 400 ₹11,600 | 1,000 ₹29,000 | 100 ₹2,900 Lowest | 1,300 ₹37,700 |
| 9.00 | Removal of rubbish, debris, rocks, demolished building materials or excavated material etc. to a distance exe. 1.50 Km but not exe. 5.00km and depositing where directed at level n.exe. 1.50m above the starting point complete as directed by Engineer In Charge. | 117 | CUM | 50 ₹5,850 Lowest | 500 ₹58,500 | 250 ₹29,250 | 800 ₹93,600 |
Tender Value
₹45.6 L
EMD Value
₹91,260
Closing Date
16 Mar 2026, 5:00 pmClosed
The Chief General Manager, Small Arms Factory
Small Arms Factory, Kalpi Road, Kanpur
Repairs to Water Proofing Treatment in MCS Section inside SAF, Kanpur
2026_AWEIL_267871_1
4073/945/SAF/OTE/25-26/EOC/13
Open Tender
Civil Works
Item Rate
180 days
SAF, Kanpur
Please refer Notice Inviting Tender, Scope of Work, List of Compliance, General special and standards terms and conditions of the tender
5 documents required · 5 mandatory
₹0
₹91,260
4 Jun 2026
23 Feb 2026
18 Mar 2026
23 Feb 2026
16 Mar 2026
23 Feb 2026
23 Feb 2026 - 16 Mar 2026
Taking down old existing treatment (tarfelt) including cement or cement lime plaster, screed bed, loose concrete ete. any description all as directed by E-I-C.
M&L for brushing neat cement slurry with 3.00 kg of cement per sq. meter. Specification for cement used:-Make: ACC, Lafarge, Ultratech or equivalent. Test Certificate of cement is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.3 of MES SSR 2009 Part-1.
M&L, for 15mm thick plaster in cement mortar 1:4 mixed with water proofing compound @2% by weight of cement over roof slab, cement plaster laid in slope all as directed by E-I-C. Make –ACC, Lafarge, Ultratech or equivalent. Test Certificate of cement is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.3 of MES SSR 2009 Part-1.
Supply only integral water proofing compound, as approved by E-I-C before use in the work. Make-STP, IWL, Dr. Fixit or equivalent. Test Certificate/QAC of WPC is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 4.8 of MES SSR 2009 Part-1.
M&L for APP modified membrane water proofing treatment on the roof slab as specified. (a) The roof surface shall be thoroughly wire brushed, washed, dried up & cleaned to remove all foreign material & dust to receive primer. (b) On the dried roof surface apply a uniform coat of bitumen primer @ 0.40 liter/sqm till the surface properly impregnated. (c) On this primed surface, applying one coat of hot blown bitumen 85/25 grade @1.20kg/sqm over the entire surfaces and then providing a layer of App based of polymeric membrane (Make-STP/IWL/Asianpaints or equivalent ) weighing 3.0 kg/sqm and minimum 3mm thick. (d) After laying APP membrane , applying a coat of hot blown bitumen of 85/25 grade @1.20 kg/sqm. (e) The overlap between membrane joints shall be 75mm on longitudinal direction and 100mm on transverse direction. (f) Top most layer of surface finish shall be with EMA paint @ 0.50kg/sqm. Test Certificate of Cement and APP membrane is required during sample approved by E-I-C. Specifications of material used should confirm to clause No. 11.43 and their sub clause of MES SSR 2009 Part-1.
Supply & fixing rough cast wired glass exe. 1.00 sqm but n.exe. 1.50 sqm, 6.40mm thick and glazing with oil putty in square for north light glass all as per specifications and as directed by E-I-C.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning and refixing complete with all fitting or removal to store, all as specified and directed by Engineer In Charge.
Trimming of tree branches over hanging over roofs etc. including shifting of debris/ branches etc. at suitable place or as directed.
Removal of rubbish, debris, rocks, demolished building materials or excavated material etc. to a distance exe. 1.50 Km but not exe. 5.00km and depositing where directed at level n.exe. 1.50m above the starting point complete as directed by Engineer In Charge.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.68 MB
Termscondtions.pdf
Tender Documents • 0.30 MB
ScheduleA.pdf
Other Document • 0.13 MB
annuexure.pdf
Other Document • 0.12 MB
compliancelist.pdf
Other Document • 0.16 MB
BOQ_311580.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .