Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.5 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹28.8 L+₹2.3 L (8.72%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L2 | Rejected-Finance Other Than L1 | |
| 3 | L3₹29.5 L+₹3.1 L (11.6%)Rejected-Finance 0 SHOP NO 48 BHAGAT SINGH COMPLEX VYAPAR VIHAR ROAD CAR PLANET VYAPAR VIHAR BILASPUR BILASPUR CHHATTISGARH 495001 | BILASPUR | CHHATTISGARH | 495001 | L3 | Rejected-Finance Other Than L1 | |
| 4 | L4₹31.0 L+₹4.5 L (17.0%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L4 | Rejected-Finance Other Than L1 | |
| 5 | L5₹31.9 L+₹5.5 L (20.6%)Rejected-Finance HOUSE NO 95 STREET NO 08 JAWAHAR COLONY NEAR LAXMI DAIRY FARIDABAD SECTOR 22 HARYANA 121005 | FARIDABAD | HARYANA | 121005 | L5 | Rejected-Finance Other Than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
1 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR AND REPLACEMENT OF LT CABLES MCCBs LT PANELS WITH CONNECTED ACCESSORIES AT SECTOR C AND SECTOR D UNDER GE 865 EWS
2023_MES_578492_1
138WE/L-70/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹80,000
Yes
15 Apr 2023
1 Feb 2023
8 Mar 2023
1 Feb 2023
1 Mar 2023
15 Feb 2023
Amount
M&L for Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for laying UG cavble in trenches on plan and n exc 1.5 m in depth in any type of soil and getting out, complete all as specified and directed by Engr-in-Charge.
M&L for Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified and directed by Engr-in-Charge.
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed by Engr-in-Charge.
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified. Note : Punned thickness of 18 CM will be measured and paid for.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class HV type-1 flate size 300mm x 180mm x 40mm, complete all as specified and directed by Engr-in-Charge.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 flate size 250mm x 150mm x 40mm, ccomplete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 185 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size150 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3.0 core laid in trences or passing through pipes.ducts or fixed to walls/poles completer all as specified. (Earth work, cable protection and sand cushioning shall be measured and paid for separately). Note : (For item Srl No 4 to 19) - Excavation, earth work, sand cushioning, cable protection shall be measured and paid for seperately).
Supply and laying in replacement of XLPE insulated, armoured, haeavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trences or passing through pipes.ducts or fixed to walls/poles complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 13 above but of size 35 sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 13 above but of size 25 sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 13 above but of size 16 sqmm, 4 core, complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 13 above but of size 16 Sqmm, 2 core, complete all as specified and directed by Engr-in-Charge.
All as per srl item No. 13 above but of size 10 Sqmm, 4 core all as specified .
All as per srl item No. 13 above but of size 10 Sqmm, 2 core , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of Lightning arresters expulsion type complete with all fittings, 30 kilo amp discharge capacity, distribution class suitable for 11 KV HT over head network including necessary connections with HT over head lines , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of LS Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 630 Amps, 36 KA, 415 Volts Four pole , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal* & Fixed Magnetic setting MCCB 400 Amps, 36 KA, 415 Volts Four pole , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 250 Amps, 36 KA, 415 Volts three pole, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 200 Amps, 25 KA, 415 Volts three pole Loadline MCCBs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 160 Amps, 25 KA, 415 Volts three pole Loadline MCCBs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 125 Amps, 25 KA, 415 Volts three pole Loadline MCCBs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of L Frame: Adjustable Thermal & Fixed Magnetic setting MCCB 100 Amps, 25 KA, 415 Volts three pole Loadline MCCBs, complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of cable end termination box heat shrinkable outdoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core fixed in replacement, complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of cable end termination box heat shrinkable indoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core fixed in replacement, complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of cable straight through jointing box heat shrinkable outdoor type suitable for XLPE HT 11000 volts cable of size 95 Sqmm 3 core , complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of LT joint kit straight through suitable for XLPE 1100 volts cable of size 120 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of LT joint kit straight through suitable for XLPE 1100 volts cable of size 95 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge.
M&L for fixing in replacement of LT joint kit straight through suitable for XLPE 1100 volts cable of size 70 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge.
M&L for fixing of LT joint kit straight through suitable for XLPE 1100 volts cable of size 50 Sqmm 3.5 core, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 15 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11000 Volts grade working pressures and current upto 200 Amps complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of tubes light grade of size 80 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors, complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of tubes light grade of size 50 mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors,complete all as specified and directed by Engr-in-Charge.
Supply only Alluminium Thimble of size 10/16/35/50/70/95 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply only Alluminium Thimble of size 120/150/185/240/300/400 Sqmm, complete all as specified and directed by Engr-in-Charge.
M&L for painting 9 mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20 CM wide ulternate white and red radium strips upto height of 1Mtr from Ground level, complete all as specified and directed by Engr-in-Charge.
M&L for painting 11 mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20 CM wide ulternate white and red radium strips upto height of 1Mtr from Ground level complete all as specified and directed by Engr-in-Chage.
Replacement of Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in groud to a depth not lss than 2.25 mtrs deep below normal ground level with top edge of earth plate not less than 1,5 ntrs below normal ground level connected to galvanised iron strip 32 x 6mm as earthing leads by means of galvanised bolts, nuts, check nuts and washer of galvanised iron or steel complete with 20 mm dia GI Pipe light grade for watering and 40mm dia GI light grade pipe for protection of strip upto test point including test point of strip 50x50x3mm GI, charcoal dust, common salt 15cm all around the earth plate all as shown inelectric plate No.5 of MES SSR Part-I all as specifed or indicated and testing on competion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh all as directed by Engr-in charge.
Supply & Installation ,testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 600 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 400 Amps Cap 4 Pole 36 KA 415 -2 No for( I/C) b) Change over switch open execution type 400 Amp 4 pole - 01 No c) MCCB 200 Amp cap 3 pole 25 KA 415 Volts - 1 Nos d) MCCB 125 Amp cap 3 pole 16 KA 415 Volts - 2 Nos e) Digital Volt meter with sellector switch(0-500V) - 02 Set f) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set g) LED indicating lamp - 02 Set Note : (i) The Make of Change over and MCCB considered are Havells/Standard/Indo Asian/HPL (ii) The rates deemed to be inclusive of suitable size copper wirinng/copper strips from Main I/C MCCBs to Channge over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (iii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the Engineer-in-cfharge before order and execution at site.
Supply & Installation ,testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 400 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 250 Amps Cap 4 Pole 25 KA 415 -2 No for( I/C) b) Change over switch open execution type 250 Amp 4 pole - 01 No c) MCCB 160 Amp cap 3 pole 16 KA 415 Volts - 1 Nos d) MCCB 125 Amp cap 3 pole 16 KA 415 Volts - 1 Nos e) Digital Volt meter with sellector switch(0-500V) - 02 Set f) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set g) LED indicating lamp - 02 Set Note : (i) The Make of Change over and MCCB considered are Havells/Standard/Indo Asian/HPL (ii) The rates deemed to be inclusive of suitable size copper wirinng/copper strips from Main I/C MCCBs to Channge over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (iii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the Engineer-in-cfharge before order and execution at site, complete all as specified and directed by Engr-in-Charge.
Supply & Installation ,testing and Commissioning in replacement of LT Panel cubical type out door floor mounted weather proof totally enclosed, (CPRI approved) factory made and made out of 3 mm thick CRCA powder coated sheet and angle iron complete with bus bar of Aluminium of suitable size for capacity 800 Amps 3 Phase and Neutral 415 Volts 50 Hz mounted on epoxy type insulators with PCC flooring and angle iron base frame complete all as directed by the Engr-in-charge including fallowing accessories:- a) MCCB 630 Amps Cap 4 Pole 36 KA 415 -2 No for( I/C) b) Change over switch open execution type 630 Amp 4 pole - 01 No c) MCCB 400 Amp cap 3 pole 36 KA 415 Volts - 1 Nos d) MCCB 250 Amp cap 3 pole 25 KA 415 Volts - 1 Nos e) MCCB 100 Amp cap 3 pole 16 KA 415 Volts - 1 Nos e) Digital Volt meter with sellector switch(0-500V) - 02 Set f) Digital Amp meter with sellector switch with necessary CT (0-500A) - 02 Set g) LED indicating lamp - 02 Set Note : (i) The Make of Change over and MCCB considered are Havells/Standard/Indo Asian/HPL (ii) The rates deemed to be inclusive of suitable size copper wirinng/copper strips from Main I/C MCCBs to Channge over switch, Change over switch to Main Bus bar and Bus Bar to Outgoing MCCBs complete all as specified and directed. (iii) The design of Panel, Make of complete accessories and drawing of the LT Panel should be submitted by the contractor for pre-approval from the Engineer-in-cfharge before order and execution at site.
Supply, Fixing, connecting and testing and Commissioning of Factory made out door Street light Panel cubical type Pole / floor mounted totally enclosed made out of 2.16 mm thick CRCA powder coated sheet and angle iron base frame of height 2' occompanied with 65 Amp contactor ,TPN MCB 63 Amp, Max capacity12 KW, with digital type timmer switch internaly pre wired suitable for 3 Ph power supply complete all as specified and directed by Engr-in-Charge.
R B TRADERS
Sona Enterprises
Horizon Construction Company
RND ENGINEERS & CONTRACTORS
darshan kumar gandhi
M.S Sharma Enterprises
EESSI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .