Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.4 LQualified Make: Ametek - Sorensen
Model: XPH 42-10 MHV 204 CONVERGENT TECHNOLOGIES 2ND MAIN MAHALAKSHMI LAYOUT BANGALORE KARNATAKA 560086 | BENGALURU URBAN | KARNATAKA | 560086 | Make: Ametek - Sorensen
Model: XPH 42-10 MHV | ₹4.4 L | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Jun 2018, 3:00 pmClosed
high performance power supplies High Performance Power Supplies ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Power Supply Type Benchtop DC AC
DC
AC + DC
Benchtop DC Number Of Outputs 1 1
2
3 Output Voltage Single Value - Output Current Single Value - Warranty (Year) >/=1 Year - CONSTRUCTIONAL Dimensions (in mm) 140 x 160 x 320 mm - Input and Output Interfaces NA - Accessories to be Supplied None - Weight (Kg) 3.6 Kg - FUNCTIONAL Line Regulation ( in percentage ) 0.01% of FSV - Input for Power Supply 230V ±10%
50Hz - Display and Control Features V
I
protection limits
and fault status indicators - Multiple Steps to cover the voltage and Current Ranges Yes - Output Ripple and Ripple: 2 mVrms Noise: - 1/5 Noise and Maximum ( in mV rms) 20 mVp-p Total Harmonic Distortion (THD) NA - Operating Temperature Range (Degree Celcius ) 5°C to 40°C - Meter Two
Independent 3-digit numeric LED display
and LED fault indicators - Protection Output short circuit
Output Over Current - Efficiency ( in percentage) NA - Programmable Output Frequency Minimum (in Hz) NA - Programmable Output Frequency Resolution ( in Hz) NA - Power Factor NA - Transient Response (in microSec) 200 µS - Operating Humidity Range ( in percentage) 20% - 80% RH (non condensing) - Load Regulation ( in percentage ) 0.01% of FSV - AC Setup Resolution for AC Power Supply (Current) ( in mA) NA - Programmable Output Frequency Maximum ( in Hz) NA - Output Current Range For AC Power Supply ( in A) NA - Accuracy for AC Power Supply (Voltage) NA - Readback Resolution for AC Power Supply (Voltage) (in mV) NA - Output Voltage Range For AC Power Supply ( in V) NA - Number of Output Phase for AC Power Supply NA Single Phase
Three Phase
Both Single and three Phase
NA 2/5 Readback Accuracy for AC Power Supply (Current) NA - Setup Resolution for AC Power Supply (Voltage) ( in mV) NA - AC Output Power ( in VA) NA - Readback Resolution for AC Power Supply Current (in mA) NA - Accuracy for AC Power Supply Current NA - Waveshape of Output DC - Readback Accuracy for AC Power Supply (Voltage) NA - DC Readback Accuracy for DC Power Supply (Current) 0.6% ± 3 digits - Readback Accuracy for DC Power Supply (Voltage) 0.3% ± 3 digits - Output Current Range For DC Power Supply ( in A) 0-10 A - Readback Resolution for DC Power Supply and Current (in mA) 10 mA - Setup Resolution for DC Power Supply (Current) (in mA) 10 mA - DC Output Power ( in Watt) 420 Watt - Readback Resolution for DC Power Supply (Voltage) ( in mV) 10 mV - Output Voltage Range For DC Power Supply ( in V) 0-42V - Ac acuracy for DC Power Supply Voltage 0.3% ± 3 digits - Setup Resolution for DC Power Supply Voltage( in mV) 10 - Accuracy for DC Power Supply Current 0.6% ± 3 digits - 3/5 CERTIFICATIONS Availability of Type tests reports from Central Government lab OR ILAC or their worldwide affiliated recognised labs OR NABL approved lab showing confirmity to the specifications No - Certificates CE-marked to: EN61010-1 and EN61326 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devashish Chandra 560017
Hindustan Aeronautics Limited Overhaul Division Vimanapura Post Bangalore 5 45 EMD Required No ePBG Required No
116278
GEM/2018/B/16594
high performance power supplies
45 days
Karnataka; Bengaluru Urban
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| high performance power supplies High Performance Power Supplies ( 5 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Power Supply Type Benchtop DC AC | - | - | - |
| DC | - | - | - |
| AC + DC | - | - | - |
| Benchtop DC Number Of Outputs 1 1 | - | - | - |
| 2 | - | - | - |
| 3 Output Voltage Single Value - Output Current Single Value - Warranty (Year) >/=1 Year - CONSTRUCTIONAL Dimensions (in mm) 140 x 160 x 320 mm - Input and Output Interfaces NA - Accessories to be Supplied None - Weight (Kg) 3.6 Kg - FUNCTIONAL Line Regulation ( in percentage ) 0.01% of FSV - Input for Power Supply 230V ±10% | - | - | - |
| 50Hz - Display and Control Features V | - | - | - |
| I | - | - | - |
| protection limits | - | - | - |
| and fault status indicators - Multiple Steps to cover the voltage and Current Ranges Yes - Output Ripple and Ripple: 2 mVrms Noise: - 1/5 Noise and Maximum ( in mV rms) 20 mVp-p Total Harmonic Distortion (THD) NA - Operating Temperature Range (Degree Celcius ) 5°C to 40°C - Meter Two | - | - | - |
| Independent 3-digit numeric LED display | - | - | - |
| and LED fault indicators - Protection Output short circuit | - | - | - |
| Output Over Current - Efficiency ( in percentage) NA - Programmable Output Frequency Minimum (in Hz) NA - Programmable Output Frequency Resolution ( in Hz) NA - Power Factor NA - Transient Response (in microSec) 200 µS - Operating Humidity Range ( in percentage) 20% - 80% RH (non condensing) - Load Regulation ( in percentage ) 0.01% of FSV - AC Setup Resolution for AC Power Supply (Current) ( in mA) NA - Programmable Output Frequency Maximum ( in Hz) NA - Output Current Range For AC Power Supply ( in A) NA - Accuracy for AC Power Supply (Voltage) NA - Readback Resolution for AC Power Supply (Voltage) (in mV) NA - Output Voltage Range For AC Power Supply ( in V) NA - Number of Output Phase for AC Power Supply NA Single Phase | - | - | - |
| Three Phase | - | - | - |
| Both Single and three Phase | - | - | - |
| NA 2/5 Readback Accuracy for AC Power Supply (Current) NA - Setup Resolution for AC Power Supply (Voltage) ( in mV) NA - AC Output Power ( in VA) NA - Readback Resolution for AC Power Supply Current (in mA) NA - Accuracy for AC Power Supply Current NA - Waveshape of Output DC - Readback Accuracy for AC Power Supply (Voltage) NA - DC Readback Accuracy for DC Power Supply (Current) 0.6% ± 3 digits - Readback Accuracy for DC Power Supply (Voltage) 0.3% ± 3 digits - Output Current Range For DC Power Supply ( in A) 0-10 A - Readback Resolution for DC Power Supply and Current (in mA) 10 mA - Setup Resolution for DC Power Supply (Current) (in mA) 10 mA - DC Output Power ( in Watt) 420 Watt - Readback Resolution for DC Power Supply (Voltage) ( in mV) 10 mV - Output Voltage Range For DC Power Supply ( in V) 0-42V - Ac acuracy for DC Power Supply Voltage 0.3% ± 3 digits - Setup Resolution for DC Power Supply Voltage( in mV) 10 - Accuracy for DC Power Supply Current 0.6% ± 3 digits - 3/5 CERTIFICATIONS Availability of Type tests reports from Central Government lab OR ILAC or their worldwide affiliated recognised labs OR NABL approved lab showing confirmity to the specifications No - Certificates CE-marked to: EN61010-1 and EN61326 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Devashish Chandra 560017 | - | - | - |
| Hindustan Aeronautics Limited Overhaul Division Vimanapura Post Bangalore 5 45 EMD Required No ePBG Required No | - | - | - |
Exempted
1 Jun 2018
22 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_116278.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .