Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹83.4 L+₹4.1 L (5.14%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹87.6 L+₹8.2 L (10.4%)Rejected-AOC 04 L BLOCK MARKET SECTOR 11 NOIDA 201301 UP GAUTAM BUDHA NAGAR | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹89.9 L+₹10.5 L (13.3%)Rejected-AOC SHALABH HOUSE 490 PURANI TEHSIL ROORKEE DISTT HARIDWAR | HARIDWAR | UTTARAKHAND | 247656 | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹98.0 L+₹18.6 L (23.4%)Rejected-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-AOC Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
23 Mar 2022, 6:00 pmClosed
HQ CWE Meerut
29J The Mall Road Meerut Cantt Uttar Pradesh 250001
SPECIAL REPAIR/REPLACEMENT OF HT O/H LINE OF JAK FEEDER WITH HT UG CABLE FROM PUMP HOUSE NO 2 TO PUMP HOUSE NO 26, PUMP HOUSE NO 25 CHANAKYA ENCLAVE AND 22 PUNJAB TO 3 RAJ RIF AT BHAGAT LINE WITH ALLIED WORKS UNDER GE (U) E/M MEERUT CANTT
2022_MES_508544_1
94013/MRT/2021-22/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut Cantt
Please refer Tender documents
7 documents required · 7 mandatory
₹1,000
GE (U) E/M Meerut
₹1.7 L
Yes
7 Apr 2022
16 Feb 2022
28 Mar 2022
16 Feb 2022
23 Mar 2022
9 Mar 2022
Amount
Dismantling of old existing ACSR conductor of any type/size from HT poles after proper taking of shutdown of respective feeder from respective power houses complete all as specified and directed.
Dismantling of cross arms/channel fixed on steel tubular poles carefully and removing from site complete all as specified and directed.
Dismantling of Stay assembly complete all as specified and directed.
Dismantling of insulators of any type/shape from existing poles after opening nuts, bolts and removing from site complete all as specified and directed.
Dismantling of old unserviceable rusted steel tubular poles of any size necessary disconnecting cables/over head conductor and removing unserviceable pole from site complete all as specified and directed.
Excavating in trenches in soft/loose soil n.exc. 1.5m wide and n. exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft/loose soil complete all as specified and directed.
Removing of excavated surplus soil to a distance not exceeding 50m and dispositing where directed at a level not exceeding 1.50 m above the starting point complete all as specified and directed.
M&L sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable) complete all as specified and directed. (Note: Punned thickness of sand only will be considered for paymnet).
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm, ISI marked complete all as specified and directed.
S&F 100mm bore galvanised steel water tubing, light grade, IS-1239 marked with all fitting (ISI marked) and laid in trenches/under roads/in drains/fixed to poles/walls (with required size flats iron clamps bolts & washers) complete all as specified and directed.
M&L for auguring of hole suitable for passing 40mm to 100mm, bore pipe in true horizontal position under road, PCC paths etc., by means of mechnical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5m in depth below existing surface level of road and not exc 30M in length complete all as a specified. Note: Pipe shall be measured and paid seperately under approprioate items and any damage to existing cables of any type shall be made good by the Bidder without any extra cost to department.
Supply, Laying & testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 Core 120 Sqmm complete all as specified and directed. Make - Havells/|KEI/Polycab.
Supply, Laying & testing cable HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 Core 95 Sqmm complete all as specified and directed. Make - Havells/|KEI/Polycab.
Supply and fix cable jointing kit for HT 11KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 120 Sqmm to 185 Sqmm size complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
Supply and fix cable jointing kit for HT 11KV grade cable for in door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 50 Sqmm to 95 Sqmm size complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
Supply and fix cable jointing kit for HT 11KV grade cable for out door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 120 Sqmm to 185 Sqmm size complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
Supply and fix cable jointing kit for HT 11KV grade cable for out door termination, heat shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AI conductor cable of size 50 Sqmm to 95 Sqmm size complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
M&L for cable jointing kit for HT 11KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 120 to 185 Sqmm complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
M&L for cable jointing kit for HT 11KV (Earthed) grade cable for straight through termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 50 to 95 Sqmm complete all as specified and directed. Make - Raychem/M-seal/Cab-Seal
Supply, install, testing and commissioning factory made and tested (including CPRI type test) HT 11 KV feeder pillar board 200 Amp capacity made out of 3.15mm CRCA sheet with 200 Amp TP copper bus bar including HT bus bar sleeves and 6 Nos HT insulator complete of size 800x400x1050mm having IP-54 protection. Structure mounted on platform rigid MS angle iron frame of 50x50x5mm with 1000mm long extended legs grouting in PCC platform duly epoxy powder coated internally and externally with approved shade, rubber gasket, hinged front and back openable doors with proper locking arrangement for dust and vermin proof complete including suitable size cable allay, lugs cable glands and making connections with bus bar, 165mm lock with keys complete including chain link fancing of 3.8mm dia not exceeding 4Kg/Sqmm, 2.1 mtr height around feeder pilar boards minimum 1 mtr away from each side of feeder piller box with door and locking arrangement to the door, PCC, MS work (MS angle 65x65x6 mm) and any other item required to complete the chain link fancing work etc complete all as specified and directed. Make - Shalabh (india) Industries Roorkee/Polycab Power system & control Jalandhar.
M&L for plate earthing for sub station equipemnts (tranformer, lightning arrestr and feeder pillar box) complete with galvanised steel plate electrode 60cm x60cm 6.3 mm thick buried directly in gorund vertically (in earth pit not les than 2.25 m below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth strip 32x6mm bolted (with nuts, bolts & check buts) riveted to earth plate at one end and connected to metallic bodies of HT/LT equipments etc, earth strip encased in and including 40mm bore GI grade pipe with all fittings from top of electrode to body of equipment fixed with and including 25x6mm flat iron clamps, bolts, nutsand washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe complete with earth pit in PCC 1:2:4 type B-O using 12mm graded crushed stone aggregate and RCC cover with lifting hook complete all specified and shown in elctrical plate No 5 of SSR Pt-I. The scope of work also includes necessary excavation and earthwork. (Note: GI strip beyond 7.5m length from earth electrode shall be measured and paid separately and excavation, Earth work, PCC shall be measured in same item rate).
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 30 Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 complete all as specified and directed by Engineer-in-Charge.
KUKREJA BROTHERS
GEPS PROJECTS
SHALABH INDIA INDUSTRIES
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .