| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 55 SHALL TOKUNA JANGALNAD PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹15.0 L+₹55,845.40 (3.86%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹15.1 L+₹61,295.50 (4.24%)Rejected-Finance KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹15.1 L+₹65,337.66 (4.52%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹15.1 L+₹67,199.77 (4.64%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
13 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIR/MAINT OF FLAME PROOF WIRING, FITTING AND FIXTURES AND DATA LOGGER AND CONNECTED ITEMS AT 8FBSU
2023_MES_603818_1
GE (AF) AWA-15/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹30,000
Yes
6 Oct 2023
16 Jun 2023
15 Jul 2023
16 Jun 2023
13 Jul 2023
1 Jul 2023
Amount
Taking down unserviceable copper/aluminium flame proof/point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc.
Taking down unserviceable DB 04 Way/8 Way 415 Volt/230 Volt including MCB/MCCBs.
Taking down unserviceable flame proof/tube light fittings of any type complete all as specified and directed .
Taking down unserviceable old aluminium sub main wiring of any size any type all as specified and directed.
Taking down the existing aluminium/copper/GI strip of any guage and type from the top of blast pens/ground/equipment/bldg (roof/down conductor) and keeping in shape custody (for serviceable strips to re-use ) complete all as specified and directed.
Taking down unserviceable/rusted GI tubing of any size any type all as specified and directed.
Taking down unserviceable Earthing material of any type all as specified and directed.
M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated, unsheathed, FRLS type, 1100 volts grade,1.5 sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes of suitable way with 3 mm thick laminated sheed cover for mounting of switches, socket, fan regulators, connected to common earth dolly complete all as specified for the following:- (a) One light /fan/bell point controlled by one nos, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp, independent controlled by one nos, one way switch.
All as per srl item No 09.00 here-in-before but using cable of size 2.5 sqmm (for phase & neutral) and 2.5 sqmm as continuous earth cable for 5/15 Amps socket outlet, independent controlled by one nos, one way switch complete all as specified.
S&F in replacement of piano type switch socket combination flush type, 6 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.
S&F in replacement of piano type switch socket combination flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type complete all as specified.
S&F Pioano type switch , Flush type single pole, one way 6 amps
S/F Ceiling rose PVC polycarbonate , isolated body 3 terminals 230 V complete.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
M&L for Flameproof point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS -694 cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including stove enamelled steel conduit ISI marked not less than 20mm dia, on surface as required on site and as specified and directed with all connected accessories including one single core multistranded PVC insulated, unsheathed, FRLS type, 1100 volts grade, 1.5 sqmm copper conductor cable as earth continuity cable including pressed steel terminal boxes made out of MS sheet not less than 1.2mm thick duly painted with one coat of red oxide primer with 3mm thick laminated sheed cover for mounting of switches, socket, for One light controlled by one switch complete all as specified and as directed.
All same as per item No.17 above but for one 3 pin socket outlet, 15 Amp, independent with cable 2.5 Sq mm size with earth wire 2.5 sq mm.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. Make- Sudhir/CG are equivalent
S&F Flame proof switch socket & plug combined in LM6 cable termination box , 16A,250V, 2P+earth complete all as specified and as directed. Make-Sudhir/CG or equivalent.
Supply and fixing LED Flame proof light fitting 2x16 Watt, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectionwith die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed. Make- Sudhir
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 60W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
M&L for flame proof sub main wiring for circuit/submain with PVC insulated unsheathed FRLS copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 2.5 sqmm complete drawn in and includindg 1.6 mm thick ERW stove enamelled rigid steel conduit conforming to IS: 9537 of suitable size including flame proof fittings such as MS junction box, MS coup-lings, unions, bends, reducers, inspection elbow, sealing compound conduit, plugs and its accessories along with 1x 1.5 sqmm PVC insulated unsheathed FRLS copper conductor cable, multi stranded FRLS type for continuous earth wire including making good the disturbed surface complete all as specified. Make: Finolex/Havells/Plaza.
Supply and fix flameproof sheet metal enclosure MCB distribution board double door single pole & neutral 240 Volts 4 way conforming to IP 66 complete including incoming SPN and outgoing SP of suitable size and capacity all as specified and directed. Note: MCB DB and MCB to be integrated for flameproofing by contractor from manufacturer before installing
S & F Single pole and neutral sheet steel powder coated vertical type Double door Distribution board for MCCB/MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply SP&N DB system 4 ways.Make: Legrand/L&T/Havells/ABB
S & F Single pole and neutral sheet steel powder coated vertical type Double door Distribution board for MCCB/MCBs fitted with 200 Amps rated bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply SP&N DB system 8 ways. Make: Legrand/L&T/Havells/ABB
S & F MCB " C" series single pole single pole 6-32 Amps breaking capacity 10 ka, 240 V 5 to 32 Amps all as specified.
S & F MCB " C" series single pole & neutral, 240 V 32 Amps all as specified.
supply, laying or passing through pipe XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq mm 4 core , complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr and n.exc 1.5 mtr deep for laying of cables or other items and getting out in any type of soil, complete all as specified and directed
Returning filling in soil including spreading leveling, watering and well ramming in layers n.exc 25cm, complete all as specified and directed
Removing excavated material (soil) not exceeding 50 mtr and depositing where directed in a level not exceeding 1.5 mtr above the starting point in any type of soil, complete all as specified and directed.
M&L for Cutting of bitumen road/PCC road/hard standing for laying of GI pipe and passing of cable including making good to disturbed surface with PCC (1:4:8) type B1, using 20 mm graded crushed stone aggregate and matching with existing surface, complete all as specified and directed.
Sand cushioning to underground cable 8cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river dry sand free form sharp particles including punning, complete all as specified and directed note:- Punned thickness shall be measured and paid
Well burnt old size class 'B' bricks of nominal size 230X115X75 mm abutting each other for cable protection, complete all as specified and directed
M&L for weatherproof senser cable , 1.5 sqmm 4 core FRLS flexible cable , 5 amps , 50 Hz, of size 7/36 guage all as specified & directed
Supply , installation , celebration and testing of data logger UIP-800D 8 Channel Universal input for all thermocouple, J, K, R, S, T, B, N & RTD ( PT-100 ) , 4-20mA, programmable by user. Relay Output : 1 NO/C/NC Relay Contact Rated 5A/230VAC, for Relay-1, Relay-2, Relay-3, Relay-4 Logging internal Memory capacity : Max. 8000 readings storing capacity for all 8 channel Data Logger model. USB host ( Pen Drive ) connectivity for online and log data report immediate ( Use FAT-32 configure Pen Drive ). Cabinet Material : ABS Plastic , Black colour Protection Class : IP-40, RS485 MODBUS RTU protocol Supply Voltage : 90 to 270 VAC, 50Hz complete all as specified and as directed Make: Ambitronics (UIP-800D)/equivalant
S&F galvanized iron strip 25x4 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified.
S&F galvanized iron strip 32x6 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified.
S&F aluminium strip 25x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified.
S&F copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site all as specified and directed by Engr-in-charge.
Refixing only of strip (serviceable strips as obtained from taking down after straightening) of any type & size but including saddles/insulators with screws for fixing complete all as specified.
S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed.
S&F in replacement of single pointed air termination aluminium rod 12mm dia, 300mm long to fix on wall/roof/pipes with suitable MS clamp, nuts, bolts and washers as required at site complete all as specified and directed. (Note: MS/PCC work shall be measured and paid seperately).
Material and labour for PCC 1:4:8 Type-D2 with 40 mm aggregate for filling in sides and foundation of poles all as specified and directed.
M&L for Brick work with subclass old sized ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar of ratio 1:6 for construction of pillar all as specified and directed by Engr-in-Charge.
M&L for brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
M&L for brazing in repair work for aluminum strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified and directed.
S&F in replacement of GI tubing 50mm bore light grade in trenches/floor/fixed along pole for cable/earth strip protection with proper size of MS clamp, nut, bolts and washers complete all as specified and directed.
M&L for dismantling of PCC earth pit chamber and making PCC chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 including RCC cover with suitable size of handle including excavation and earth work as required at site complete all as specified and directed by the Engineer-in-Charge.
S&F in replacement of RCC cover of earth pit of size as per electrical plate No. 3 of SSR-2009, Part-I complete with suitable handle complete all as specified and directed.
S&F in replacement of funnel with wire mesh suitable for each pit complete all as specified and directed.
M&L for common salt, nitrates etc for recharging of earthing pits by filling in earthing pits complete all as specified and directed. (Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pit after mixing in water in appropriate quantity.)
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
Test Point terminal block made of gunmetal or phosphorus bronze size 75X75X25mm drilled and screwed including 03 Nos 8 mm dia long hex head screw complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of GI tubing 20mm bore medium grade in trenches/floor including accessories (tee, elbow , socket and union etc) complete all as specified.
S&F of Bib tap plug type of cast iron, screwed for iron pipe of size 20 mm complete all as specified and as directed.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32mmx6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing complete all as specified.
M&L for plate earthing complete with copper plate electrode 60 cm x 60 cm x 3.15 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper earthing strip 20x3 mm bracing/bolted (with copper nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus including testing complete all as specified.
Note :- An amount of Rs. 40.645.50 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
MS Ghulam Hassan and Sons
M/s Gh Qadir and Sons
M/S ABBAS M. ENTERPRISES
nazir Ahmad Dar and sons
M/S ABDUL RASHID AND CO
M/S Sonaullah Wani and Sons
BHAT CONTRACTORS AND GENERAL ORDER SUPPLIERS
M/S LEO TRADERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .