Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹18.0 L+₹2,660 (0.15%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹18.4 L+₹44,434 (2.47%)Rejected-Finance 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹20.7 L+₹2.7 L (15.2%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹21.0 L+₹3.0 L (16.9%)Rejected-Finance | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NW KARANJA
NAVAL STATION KARANJA URAN RAIGAD MAHARASHTRA 400704
REPAIRS AND REPLACEMENT OF HDPE TANKS, CONCRETE TANKS, AND LOFT TANKS INCLUDING CLEANING OF OVERHEAD SERVICES TANKS AND LOFT TANKS ETC IN AREA UNDER AGE B/R-I AT NAVAL STATION KARANJA
2021_MES_490753_1
8452/E8
Open Tender
Civil Works
Item Rate
240 days
GE NW KARANJA
REPAIRS AND REPLACEMENT OF HDPE TANKS, CONCRETE TANKS, AND LOFT TANKS INCLUDING CLEANING OF OVERHEAD SERVICES TANKS AND LOFT TANKS ETC IN AREA UNDER AGE B/R-I AT NAVAL STATION KARANJA
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹60,000
Yes
2 Feb 2022
26 Nov 2021
5 Jan 2022
26 Nov 2021
3 Jan 2022
21 Dec 2021
26 Nov 2021 - 21 Dec 2021
60 days
Amount
Taking up or down 15mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 20mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 25mm bore of pipe steel tubing and connections, complete all as specified and directed.
Taking up or down 40 or 50mm bore of pipe steel tubing and connections, complete all as specified and directed.
S & F 15 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S & F 20 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S & F 25 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
S & F 50 mm bore GI tubing medium grade with all fittings and fixed to walls or laid in floors and incl concealed pipe lines complete all as specified and directed.
Taking up or down 15mm dia CPVC pipes and concealed connection including, cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20mm dia CPVC pipes and concealed connection including, cleaning for refixing or removal to store complete all as specified and directed.
Supplying and fixing of 15mm bore dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with al fittings to walls with hooks, ceiling or laid on floor and incl concealed pipe lines complete all as specified and directed.
Supplying and fixing of 20mm bore dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings to walls with hooks, ceiling or laid on floor and incl concealed pipe lines complete all as specified and directed.
Taking up or down 16mm dia KITEC Composite pipes and concealed connection including, cleaning for refixing or removal to store complete all as specified and directed.
Supplying and fixing of 16mm dia KITEC composite PIPE for 10kg/cm2 with all fittings to concealed connection walls with hooks, ceiling or laid on floor and incl concealed pipe lines complete all as specified and directed
S&F in repair 15mm bore angle cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed
S&F in repair 15mm bore stop valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed
S&F in repair 20mm bore stop valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed
S&F in repair 15mm bore concealed stop valve chromium plated with long shank and cup concealed type for GI out let/inlet pipe or for union including threading to existing pipes on both ends (included cutting and plastering) complete all as specified and directed
S & F in repair Gun-metal, globe or gate valves ISI marked, 15mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves ISI marked, 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
S & F in repair Gun-metal, globe or gate valves ISI marked, 25mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed.
Disconnecting existing tanks, not exc 250 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and refixing in postion and cleaning and removing all as scales and dirt, etc from tank and from mouth of circulating pipes, etc complete and washing the tanks by using bleaching powder and clean water & including reconnecting & re-fixing the same in its original position included Note. a, b, c in this items complete all as specified and directed. Note. (a) writing the date of cleaning on the outer surface of the tank by paint, letters of 3cm height and width including obliterating old writing all as specified and directed. (b) If tank cleaning time, any blockage of internal/external pipe line to be cleared and incl all necessary fittings. (c) Before tank cleaning inform to all Qtrs individuals. (d) Before the tank cleaning disconnect and refixing the same position.
All as per item No 22, but of capacity exc 250 and not exc 500 litres complete all as specified and directed.
All as per item No 22, but capacity exc 500 and not exc 1000 litres complete all as specified and directed.
All as per item No 22, but capacity exc 1000 and not exc 2000 litres complete all as specified and directed.
All as serial item No 22 but RCC overhead water tanks applying one coat of lime wash on the inner faces of the tank capacity exc 1000 ltrs but not exc 2000 ltrs capacity complete all as specified and directed.
Petty repair to internal water/external inlet water GI pipe line n exc 1 RM any type including socket,elbow,nipple ,with repair to water blockage , pipe line leakage (arreat the leakage incl all fitting) including concealed water tubing etc at of any height using scaffolding complete etc all as directed
Petty repair to internal water/external inlet/concealed water pipe line n exc 1 RM any type CPVC/HDPE/KITEC including socket,elbow,nipple ,with repair to water blockage , pipe line leakage (arreat the leakage incl all fitting) including concealed water tubing etc of any height using scaffolding complete etc all as directed
S&F in repairs 300 ltrs capacity rotatonal moulded polyethylene water storage tanks 'ISI marked' Triple layer in white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including connecting the CP brass float valve of required size, PVC tank cover incl all fittings, 20mm bore GI medium grade overflow pipe, 40mm bore GI flush pipe with plug, 15mm bore GI vent pipe and RCC staging a shown on drawings. The length of overflow pipe shall be brought upto nearest sump/outlet of rain water spouts/holes and connect to inlet and outlet pipes, tank nipple, elbow, bend, union, sockets, etc complete all as specified.
All as per item No 29, but 500 litres capapcity.
All as per item No 29, but 750 litres capapcity.
All as per item No 29, but 1000 litres capapcity.
All as per item No 29, but 2000 litres capapcity.
S & F in repair loft type water storage tank (ISI marked) of capacity 200 ltrs, hoisted and fixed in position including PTMT ball valves of 15mm dia, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in 15mm bore GI tube etc including taking down of old tank complete all as specified and directed. (GI pipe measured separately)
S & F in repair Ball valves 15mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -142 gms) complete all as specified and directed.
S & F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
S & F in repair Ball valves 25mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
S & F in repair Ball valves 50mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed.
S & F in repair Non return valves (NRV) ISI marked, 20 mm bore,screwed both end for iron pipe complete all as specified and directed. complete all as specified and directed.
S & F in repair PVC covers of PVC/ HDPE water tank suitable for 300 capacity including all necessary fixing arrangement complete all as specified and directed.
All as per item No 39, but 500 litres capapcity.
All as per item No 39, but 750 litres capapcity.
All as per item No 39, but 1000 litres capapcity.
All as per item No 39, but 2000 litres capapcity.
Note:- a. The complaints shall be attended on the same day and complaints slip duly signed by by the user will be deposited back to the JE(Civil) on the same day. b. A penalty of RS 500/- per complaint will be levied in case complaint not rectified by contractor on same day. c. The register shall be maintained for this purpose which sall be kept in custody of JE Civil indicating date and time of complaint informed and rectified respectively. d. If any type of high rise buiding, repair pipe line work and other above any items(item no.1 to 44) fixing time, the contractor to be arrange the ladder and scaffolding and all other safety equipments before start the work.
INDIA ENGINEERS AND CONTRACTORS
BALAJI TRADERS
M.K Enterprises
M/s Vishwakarma Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .