| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹34.8 L+₹1.5 L (4.41%)Rejected-Finance MOHAMMADPUR CHAIL KAUSHAMBI UTTAR PRADESH 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | L3₹34.9 L+₹1.6 L (4.73%)Rejected-Finance | L3 | Rejected-Finance Other than lowest quoted tenderer | |
| 4 | L4₹35.6 L+₹2.3 L (6.79%)Rejected-Finance | L4 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
28 Jul 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
PROVN OF CERTAIN SPECIAL REPAIR AND MINOR WORKS UNDER AGE BR-I AND AGE BR-II AT NEW CANTT ALLAHABAD
2021_MES_456094_1
8514/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹70,000
Yes
21 Aug 2021
30 Jun 2021
30 Jul 2021
30 Jun 2021
28 Jul 2021
14 Jul 2021
60 days
Amount
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n exc 1.5 Sqm each including iron mongaries complete all as specified.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc 1.5 but n exc 4.00 Sqm each including iron mongaries complete all as specified..
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for incl removing rubbish off the premises complete all as specified and directed.
M&L 75 mm thick PCC 1:2:4 type B-2 using 20 mm graded aggregates as in plinth protection and path and finishing even & fair without using extra cement laid in bays complete as all spfd and directed by EIc
M&L PCC 1:3:6 type C1 with 20 mm graded stone aggregate as in padding over roof slab for making slope on roof top surface complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for coloured Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including screed bed 10mm thick in cement mortar 1:4 finished rough to receive wall tiles etc complete all as specified and directed.
M & L for Non skid ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for Non skid ceramic colour tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for normal water proofing treatment on roof slab consisting with following operation (i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wir brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Lit/m2 on the surface. Laying 3mm thick APP membrane having non-woven polyester matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm ie overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shal be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers' (ii) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane (iii) Dusting dry sand @ 0.75 Kg per Sqm over the membrane indicated above
M&L for 15 mm thick Cement plaster on surfaces of concrete in CM 1:4 on roof surfaces mixed with WPC complete all as specified and dierected. Note : WPC shall be measured and paid separately
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work exc 15 cm but n exc 30 cm in width or girth; including cutting to edges, all mi- tres and stopped ends, etc.
M&L for preparation of new or previously untreated surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of aluminium paint, complete all as specified and directed.
M&L Water proofing treatment walls of bathroom consisting of the following operation :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) Filling of all brick joints with cement mortar 1:4 (iii) Applying a coat of Chemical Dr fixit Pidi fin 2K (iv) applying fibe mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, plaster the surface with CM 1:4 15 mm thick . Note All water proofing treatment will be executed by the authorised representative of Dr fixit.
M&L Water proofing treatment on sunken floor consisting of the following operation :- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) M & L PCC 1:2:4 type (Bo) using 12.5 mm graded stone aggregate 50 mm thick, finishing the surface even and smooth without using extra cement (iii) Applying a coat of Chemical Dr fixit Pidi fin 2K (iv) applying fibe mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, screeding the surface with CM 1:4 15 mm thick including finishing even and smooth using extra cement. Note All water proofing treatment will be executed by the authorised representative of Dr fixit.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for incl removing rubbish off the premises complete all as specified and directed.
M & L for RCC nominal mix type B1 1:2:4 (using 20 mm graded aggregates) in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M & L for Mild steel TMT bars 10 mm dia and over, cut to length, bent ot shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips
Formwork to chullah hoods chajjas troughs and similar items including edges for fough finished surfaces of concrete
S&F solid PVC molded door frame of size 50mm x 95mm made out of 5 mm single side prelam PVC sheet complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolt of extruded section complete all as specified and directed
S&F 100mm long Aluminium butt hinges of extruded aluminium alloy with galvanized mild steel hinge , pin anodized complete all as specified
S & F aluminium bow handle,cast type,anodised 125mm long complete fixed with steel screws.
S&F Aluminium sliding door bolts plate type stove enamelled black with bright bolt not less than 12mm dia with & including a min of 6 bolts & nuts four on bolt plate & two on staple plate & fixed 250 mm long
Demolition of brick work or stone/builder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles.
M & L Brick work with fly Ash old size bricks, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6 complete.
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site.
Taking up or down 20 mm bore, steel tubing and connection including cleaning for refixing or removal from site.
M&L for 15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
M&L for 20mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
All as per ser item no 30 here-in-before but refixing old steel tubing.
All as per item no 31 here-in-before but refixing old steel tubing.
Cutting chases pinning in making good to facing where required for concealed water tubing and making good cutting not exc 10cm girth in brick walls complete.
S&F in repair bib taps 15mm bore, long body bib cock with wall flange, fancy type, brass chromium plated with capstan head/ever and cup, screwed for iron pipe or for brass ferrule including all accessories complete all as specified and directed.
M & L in repair 15mm Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed
M & L in repair 15mm Stop/angle valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, screwed both ends for iron pipe or for unions and fixed
S&F in repair fancy type brass chromium plated shower rose with arm complete
S & F 20 mm Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed complete.
S&F in repair Brass chromium plated tubular towel rail 20mm dia fixed with screw to wall complete
S&F in repair vitrious china soap dish fixed to plugs with chromium plated brass screws complete
S&F in repair vitreous chaina squatting pan Orissa pattern size 580x440 white with integral foot rests (Excluding flushing cistern and flush pipe) complete all as specified and directed.
S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white, including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed.
S & F in repair vitreous China bowl urinals Half stall type, white with grating and unions for discharge pipe including providing and fixing plugs, bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement complete all as specified
S&F Sheet Glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long.
S&F, in repair PVC Flushing cistern 10 ltr capacity with inlet ball valve float and handle and 32mm bore flush pipe including bracket complete.
S & F in repair PVC connection 15 mm bore, 600 mm long complete with both ends unions.
Demolition/taking down PVC/CI drain/Rain Water Pipe under floor or wall of internal dia 75/100 mm, set in cement mortar/ Bricket (working height not exc. 10 mtrs ) complete incl fittings.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore complete.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore complete.
S&F PVC (SWR) bends any radius, 75 mm bore, provided with access door complete.
S&F PVC (SWR) bends any radius, 110 mm bore, provided with access door complete.
S&F PVC (SWR) junction single (single T), equal or unequal, 75 mm bore, provided with access door complete.
S&F PVC (SWR) junction single (single T), equal or unequal, 110 mm bore, provided with access door complete.
S&F PVC (SWR) branch piece, double (double Y) equal or unequal, 110mm bore fixed to wall in west pipe
S&F PVC (SWR) vent cowl, 110 mm bore complete.
M&L in repair PVC (SWR) floor trap plain with grating in cluding jointing with solvent cement 75/100mm dia
Dismantling water storage tank exc 500 & n’ exc 1000 ltr capacity all as specified
S & F for 1000 ltr capacity rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position including tank nipple etc all as specified in SSR part-I including 20mm dia ball valve with epoxy coated aluminium rod and high density plastic ball complete all as specified and directed.
S&F in repair vitreous china wash basin, snow white of size 440x525x195mm oval shape including brackets including cutting for and pinning in ends of brackets in CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed.
S & F in repair Hot and Cold mixture pillar taps for WHB, cast copper alloy, with half/quarter turn swan neack, fancy type, chromium plated, screwed down high pressure, long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore complete.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M & L 15 mm thick rendering on brick work or concrete surface in cement mortar 1:4 mixed with water proofing compound, surface finished even and fair complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately as supply only.
M & L Rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished fair and even complete.
M&L for Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete
Supply only integral water proofing compound.
S&F in repair Stainless steel wire mesh 0.36 mmdia fixed with tinned tacks of stainless steel wire and avg width of aparture 1.4mm complete.
Material & labour for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete.
Material & labour for preparation of new plastered surfaces of wall and applying two coats of white wash complete.
Preparing new plastered or unplastered surfaces of ceiling and applying two coats of white wash complete.
Preparing old plastered or unplastered surfaces of ceiling and applying one coats of white wash complete.
Preparing old plastered or unplastered surfaces of wall and applying one coats of white wash complete.
Material & labour for preparation of old plastered surfaces of wall and applying two coats of cement base paint complete.
M&L for 18-20mm thick granite (of any type) stone slab work (table rubbed and polished) as wash hand basin laid over and including 20mm thick screed bed in cement mortar 1:6, set in white cement with pigment and pointed in white cement 1:2 using marble dust with admixture of pigment to match with shade including cutting granite slab circular or oval shape for fixing of vitreous china wash hand basin of desired size and shape including rubbing and polishing and making sandwitch moulding to edges complete all as specified and directed. Note - Breakage if any in granite slab will be born by the contractor).
S&F in repair vitreous china urinal partition white of size 310 x 770mm complete all as specified and directed.
S&F Steel ventilators, fixed type, with glazing bars complete all as specified and directed
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specifeid and directed
S&F window guard bars, plain let in and fixed independently in wooden frames L or T section support for shelves etc., and similar articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed
S & F 3 mm thick plain sheet glass pin headed and glazing with oil putty or wooden beads in square area exc. 0.5 Sqm in each pane complete.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
Surface Dressing in soft/loose soil n.exc.(not exceeding) 15 cm deep and getting out complete as all spfd and directed by EIC
M&L Earthwork in excavation in foundation in trenches exc. 1.5 mt. wide and exc. 1.5 mt depth in soft/loose soil and getting out complete as all spfd and directed by EIC
Returning filling including spreading levelling watering and well ramming not exc.25 cm thick soft or loose soil complete as all spfd and directed by EIC
Removing excavated material (soil) n.exc. 50 mt. and depositing where directed at a level n.exc. 1.5 mt. above the starting point complete as all spfd and directed by EIC
M&L PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foudation filling and mass concrete complete as all spfd and directed by EIC.
M&L RCC M-25 Design mix using 20 mm graded stone aggregate in Foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete.
M&L RCC M-25 Design mix using 20 mm graded stone aggregate in Beams, Cantilevers, bressurmmers, Lintels over 1.5 m span complete as all spfd and directed by EIC
M&L Formwork to rough finished flat surface of concrete to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams; and similar work; vertical or to batter complete as all spfd and directed.
M&L Formwork to rough finished flat surface of concrete to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels,cantilevers, shelves including supports, overhangs, etc, also splays between floors and beam etc complete as all spfd and directed by EIC.
M&L Formwork to rough finished flat surface of concrete to soffits of suspended slab such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (Horizontal or sloping) complete as all spfd and directed by EIC.
M&L of mild steel TMT Bars 5mm dia and over up to and including 10mm dia in stirrups,spacers and binders cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends binding with and including mild steel wire (annealed) not less than 0.9 mm dia securing with clips complete as all spfd and directed by EIc
M&L Hardcore of broken stone or boulders of gauge nexc. 63mm, deposited, spread and levelled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete as all spfd and directed by EIC
M&L PCC (1:5:10) type E-2 using 40 mm graded stone aggregate as in foudation filling and mass concrete complete as all spfd and directed by EIC.
M&L 40 mm thick PCC(1:2:4) type B-1 using 20 mm graded stone aggregate for floor finishing cement concrete surface even and smooth with using extra cement laid in panels complete as all spfd and directed by EIC.
M&L 38 mm width & 3 mm thick glass dividing strips for laying in floor in panels complete as all spfd and directed.
M&L for preparation of new plastered surfaces and applying three coats of white wash on Wall complete.
M&L for preparation of new plastered surfaces and applying three coats of white wash on ceilling complete.
M&L plaster 20 mm thick in one layer CM(1:4) on concrete surface over roof slab finished even and smooth without using extra cement including water proofing compound @ 3% by weight of cement over and including application of cement slurry @3kg/sqm after cleaning,sweeping the RCC slab to remove dust before application of plaster complete. (NOTE:- WPC measured and paid seperately)
M&L for rendering 10mm thick in CM 1:3 on ceiling surfaces complete all as specified and directed.
Preparation of newaly plaster surface of wall and applying two coats of oil bound distemper complete all as specified and directed.
Preparation of newaly plaster surface of ceiling and applying two coats of white wash complete all as specified and directed.
Dismantaling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed.
Complete removal of mud phuska from roofs of any thickness and removing the waste material from site to a distance exc. 250m but not exc. 500m and deposited where directed including cleaning of surface complete all as specified and directed.
Demolition of plain cement concrete in any position including tar felt & cement mortar bedding etc from roof or sunken complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-0 (12.5mm graded stone aggregate) as in roof padding,roof kerbs, benching on roof slab and other similar works laid as per slop required finished even and fair complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of roof when concrete is green complete all as specified and directed.
Cleaning the dust,durt and any other foreign material from roof surface and applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986 complete all as specified and directed.
M&L for Laying of 3mm thick APP membrane of (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed. (Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
Supply only Liquid water proofing compound (ISI marked) complete all as spesified and directed.
M&L for 40mm thick brick tiles laid over and including 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement or as per manufacturer's instruction and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) complete all as specified and directed.
Applying two coats of bitumen based aluminium painting @ 0.15 Kg / sqm on water proofing treatment with preparation of surface complete all as specified and directed.
S & F in repairs 110 mm bore PVC (SWR) pipes singles socket in any length with rubber ring joints fixed to walls or floor or in trench complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channel or surface drain including forming and finishing with extra cement including taking down existing concrete complete all as specified and directed.
Cutting holes in brick walls in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for purpuse made cutting and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required in full brick wall complete all as specified and directed.
Dismantling of oneway wooden trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed.
Dismantling of timber framed scantlings 40 sq. cm and over in section, in any positioncomplete all as specified and directed.
S&F MS framed work as in doors frame,doors or gates of angle iron,door frame or other section with gusset plate, rails, braces etc complete, drilled for fixing of steel sheeting or other covering etc. to prepared for hanging or sliding with including either hooks and hinges, also fastening and fixing and similar work confirming to Fe 290 Gde-E-165 complete all as specified.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe Fe 290 Gde E-165 complete all as specified.
M&L for steel work in square or rectangular hollow section used as in purlins, rafter, column, where connected common rafter and running rails fixed with angle cleat or other connection plates including special shaped washer etc. using induction butt welded tubes conforming to IS-4923-1997 grade Yst-240 complete all as specified and directed.
Preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
S&F in repair powder coated GI ceiling suspension system false ceiling grid of 600x 600mm size and 0.30 mm thick (MS galvanized with main tee, cross tee and wall angle grid hanging with 4mm dia Gl wire and roof fasteners or butterfly clips etc complete all as specified and directed.
S&F in repair 4 mm thick non asbestos fiber cement building board of 600x600 mm in size (HPSC E-classic) decorative finish fixed to aluminum /CGI frame work with hold down clips in false ceiling complete all as specified and as directed.
Dismentling timber framed filled rails, post, rafters purlins, etc under 40 sqm in section complete all as specified and directed.
S&F II nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, sup-plied and fixed to walls complete all as specified and directed.
S&F (IInd class hard wood) factory made Glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc. (divided in to square with sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mi-tred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Sec-tion 8, cla-use 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F IInd class HW factory made 35mm thick plain framed panelled shutters with lock rail, panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS-1003 (Part I) Kiln, Seasoned and chemically pressure treated complete all as specified and directed.
S&F plain fillets, square, rectangular or triangular in section clean sawn secured with nails or brads 2nd class hard wood, sectional area exc 13 Sqcm but not exc 25 Sqcm complete all as specified and directed.
Supply only galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm for new door / window shutter complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18mm complete all as specified and directed.
M&L preparation of new wooden surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F 100 mm long mild steel butt hinges, cold rolled, medium weight complete all as specified and directed.
S&F for 200mm long anodised aluminium barrel tower bolt of extruded section complete all as specified and directed.
S&F 300mm long, aluminium alloy, anodised aldrop door bolt including fixing clips of sheet, cast or exturded section and fixing bolts and 16mm dia bolt of sliding bolts of extruded sections complete all as specified and directed.
S&F 150mm long anodised aluminium handles, fabricated type complete all as specified and directed.
S&F 300mm mild steel, ordinary rat tail rod pattern springs includ-ing roller and roller plate complete fixed in repair all as specified and directed.
S&F Ist class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles n exc 200 cu. Cm each all as specified and directed.
M&L removal of existing treatment on wall surface and applying two coats of distemper over a coat of putty complete all as specified & as directed.
M&L removal of existing treatment on wall surface and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
M&L preparation of old decorated surface of wall and applying two coats of apex weather proof external paint over a coat of putty complete all as specified and directed.
M&L for preparation of old painted surface of wooden work and applying one coat of synthetic enamel paint on surfaces of any description exc 10 cm width or girth complete all as specified and directed.
M&L for preparation of old painted surface of steel surfaces (previously decorated) painting with one coat of synthetic enamel paint on old steel surfaces for grills, guard bars ,shutters etc complete all as specified and directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring with FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade conceal conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed conceal surfaces complete all as specified and directed for the following :-
(i) One light/fan/bell point controlled by one switch
(ii) One point for socket outlet 5 amps on independent board but below the switch board in same vertical /horizontal plane
(iii) One point for socket outlet 5 amp same board
(iv) One 3/5 pin socket outlet, 6 Amp on the same board with other switches
(v) One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane. Note : Socket Outlet point provided beside to switch board on same wall will be measured as below the switch board
(vi) One 3/5 pin socket outlet, 6 Amp on “independent board”
All as per ser item No. 149 here in before but point wiring using 2.5 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 16 amps “ independent board”.
All as per Ser item No. 149 here in before but point wiring using 4.0 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet, suitable for AC point “ independent board”.
Supply & fixing ISI marked switch piano flush button type, single pole, one way, 6 Amps
Supply & fixing socket out let 6 pin, 6 Amps flush type
Supply & Fixing switch socket combination multipurpose 2 in 1, 6 pin, 6 and 16 Amp
Supply & fixing ceiling rose 3 pin/PVC/ polycarbonate
One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
S&F switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 amp flush type complete all as specified & directed.
S&F switch piano flush type 16 amps, 230V AC single pole one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type complete all as specified & directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified & directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified & directed.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 40/63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified & directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
(a) 2x4.0 sq. mm + 1x2.5 sq. mm earth wire
(b ) 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Cutting & Chasing required on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
Cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
(i)100mm x 100mm
(ii) 175mm x 100mm
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.as specified or directed by Engr-in- Charge.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers as specified and directed by Engr-in-Charge.
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Supply & fixing in replacement of existing worn out DB with single phase & neutral MCB Distribution Box of 8 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & fixing in replacement of MS terminal box fixed for geyser/AC by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket of current rating 20 amps complete with fixing one single pole MCB , 'C' series of current rating 25 amp including cutting, chasing in wall to recess the same and making good complete all as specified and directed.
Supply & fixing in replacement of MCB double pole, 50/63 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing in replacement of MCB double pole , 40 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing in replacement of worn out MCB with MCB SP, 06 to 32 Amps 240 volts, 'C' Series, ISI marked and conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
HARSH ASSOCIETES
MS BHAVANA ENTERPRISES
M/S C L GUPTA AND SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .