Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC BANDARAILAH MALDA | MALDA | MALDA | WEST BENGAL | ₹9.0 L | L1 | Accepted-AOC L1-Accepted |
| 2 | L2₹9.1 LRejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 UDYAM WB 23 0013338 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | ₹9.1 L | L2 | Rejected-Finance Higher than L1. |
| 3 | L3₹9.2 LRejected-Finance BIBIGRAM SOUTH NEAR JALALIA GIRLS HIGH SCHOOL MALDA ENGLISHBAZAR 732101 | ENGLISHBAZAR | MALDA | WEST BENGAL | 732101 | ₹9.2 L | L3 | Rejected-Finance Higher than L1. |
| Sl No | Description | Qty | Unit | NABAUDYAG ELECTRICAL ENGINEERING CO OP. SOC. LTD. L1 | DEY ENTERPRISE L2 | HANNAN BUILDERS PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Inspecting the 6 nos. control panel (one no. blower panel,one no. Flash mixture panel , one no. Alum mixture panel,one no. chlorination control panel and two nos. Chalariflocculator control panel ) throughly by licensed electrician for fault detection as per direction of E.I.C. | 6 | unit | - | - | - |
| 2.00Supply & delivery of following electical & electronic equipments at site: | ||||||
| 2.01 | A ) 250 Amp Switch disconnector fuse unit conforms to IEC IS 13947 (Part- 3) with extra fuse as per IEC 60947-3 in Stainless Steel enclosure
(with Box). (Make: L&T/ any other approved make) | 1 | no. | - | - | - |
| 2.02 | B) i) Four pole MCCB having rating of 100 Amp, 415V, 25kA, 50 Hz conforming to IS /IEC: 60947-2. (Make: Siemens/ABB/ any other approved vendor of PHED) | 4 | nos. | - | - | - |
| 2.03 | (ii ) Four pole MCCB having rating of 63 Amp, 415V, 25kA, 50 Hz conforming to IS /IEC: 60947-2. (Make: Siemens/ABB/ any other approved vendor of PHED) | 4 | nos. | - | - | - |
| 2.04 | (iii)Four pole MCCB having rating of 32 Amp, 415V, 25kA, 50 Hz conforming to IS /IEC: 60947-2. (Make: Siemens/ABB/ any other approved vendor of PHED) | 3 | nos. | - | - | - |
| 2.05 | iv) Suitable Rotary drive kit including handle with door lock interlock defeat & interlocking facility for above MCCB ; (Make: Siemens/ABB/ any other approved vendor of PHED) | 11 | nos. | - | - | - |
| 2.06 | C) (i) 10 VA 200/5 class-I Current Transformer (Make: Kappa/Rishabh/any other approved vendor of PHED) 200/5 C.T Coil | 3 | nos. | - | - | - |
| 2.07 | (ii) 5 VA 100/5 class-I Current Transformer (Make: Kappa/Rishabh /any other approved vendor of PHED) | 9 | no. | - | - | - |
| 2.08 | iii) 5 VA 60/5 class-I Current Transformer (Make: Kappa/Rishabh/any other approved vendor of PHED) | 6 | no. | - | - | - |
Tender Value
Refer Docs
EMD Value
₹18,000
Closing Date
22 Feb 2019, 2:00 pmClosed
EXECUTIVE ENGINEER_MALDA MECHANICAL DIVISION_PHED
Office of The Executive Engineer_MLMD_PHED Doulatpur PHE Complex Maliha Malda
Rectification Repairing of existing 6 nos. control panel one no. blower panel,one no. Flash mixture panel , one no. Alum mixture panel,one no. chlorination control panel and two nos. Chalariflocculator control panel at Mathurapur WTP
2019_PHED_216524_2
WBPHED/EE/MLMD/NIET_52 of 2018-2019
Open Tender
Electrical Work/ Equipment
30 days
Daulatpur, Malda
Please refer Tender documents.
3 documents required · 3 mandatory
₹18,000
Yes
10 Apr 2026
15 Feb 2019
25 Feb 2019
16 Feb 2019
22 Feb 2019
16 Feb 2019
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.05 MB
Tendernotice_2.pdf
PDF • 0.86 MB
BOQ_392876.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid