Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr Quoted ₹1.1 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.1 Cr+₹2.1 L (1.92%)Rejected-Finance | ₹1.1 Cr+₹2.1 L (1.92%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹1.1 Cr+₹5.9 L (5.39%)Rejected-Finance C O AKBAR FURNITURE HOUSE MALHAR MORH GARHI UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.1 Cr+₹5.9 L (5.39%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹1.2 Cr+₹9.0 L (8.32%)Rejected-Finance | ₹1.2 Cr+₹9.0 L (8.32%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹1.3 Cr+₹19.7 L (18.1%)Rejected-Finance NEW JAIL ROAD UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹1.3 Cr+₹19.7 L (18.1%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
11 Jul 2023, 6:00 pmClosed
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-5, NP-7 (SINGLE OR LIVING ACCN) AND BLDG NO NP-49/51 (CH AND DH) OF AN INF BN UNDER GE (SOUTH) UDHAMPUR
2023_MES_601586_1
CWE/U(S)-26/2023-24
Open Tender
Civil Works
Item Rate
270 days
UDHAMPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (SOUTH) UDHAMPUR
₹2.0 L
Yes
7 Sept 2023
6 Jun 2023
18 Jul 2023
6 Jun 2023
11 Jul 2023
27 Jun 2023
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 10mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and includingMS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and fair without using extra cement, complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. , complete all as specified and as directed.
Non skid, coloured ceramic jointfree/rectified tiles 8 to 9mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
Ultracharged/double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match,over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed.
Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick plaster in cement mortar 1:3, complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Glazed coloured ceramic tiles in dado/vertical surface (600x450mmx 7mm) thick set and jointed in neat cement slurry and pointed in coloured cement to match the surface, over and including 10mm thick plaster in cement mortar 1:3, complete all as specified and as directed.
Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab in floor including rubbing and polishing over & including screed bed or bedding layer 20mm thick in cement mortar (1:4) complete, all as specified and as directed.
Machine cut kota stone 18-20mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over & including 10 mm thick rendering in CM (1:3) complete all as specified and as directed.
150mm wide strip of makrana white marble 18-20 mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing over and including 20 mm thick CM 1:4 mortar backing for fixing the stone slab, complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proprotion as mentioned in manufacturer's instructions complete all as specified and as directed. Note : Water proofing compund to be measured and paid for separately as supply only.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed.
Grouting 25 mm thick for damaged columns beams chajjas parapets etc. including any temporary shuttering to edges with cement mortar 1:2, complete all as specified and as directed.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling, complete all as specified and as directed.
Preparation old surfaces including complete removal of existing treatment ( white wash) and applying two coats of white wash on ceiling complete all as specified and as directed.
Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over and including a coat of primer, complete all as specified and as directed.
Preparation of old plastered or unplastered surfaces of wall (including facia) and applying two coats of weather proof exterior emulsion paint (apex) painting on walls, complete all as specified and as directed.
Preparation of old surfaces including complete Removal of existing surface of cement base paint and applying two coats of cement base paint on walls, complete all as specified and as directed.
Two coat of Oil bound distemper including a coat of primer including preparation of newly plastered surfaces of wall, complete all as specified and as directed.
Preparation of old surfaces including complete Removal of existing surface and applying two coats of Oil Bond distemper on walls, complete all as specified and directed.
Supply only liquid water proofing compound, complete all as specified. (Make : Dr Fixit, LW+, STP Ltd No 1 (L) & SIKA or equivalent as specified in PS)
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed.
Description all as per item No. 30 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, complete all as specified and as directed.
Description all as per item No 32 above but frame size 105 x 60 mm.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete with glazing bars dovetailed or welded including one shop coat of red oxide primer complete all as specified and as directed. Notye : i) The window shall be fabricated as per Drg No CEUZ/TD/1269/2008 Sheet 1/3 to 3/3 (ii) MS fillets, glazing, wire gauge shall be measured and paid separately.
Description all as per item above No 36 but without glazing bar complete all as specified and as directed.
Factory made mild steel ventilators (box type) with upper top hung shutters and bottom fixed type shutters including pintol hinges, steel peg stay and one shop coat of red oxide primer complete all specified. Note : i) The window shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. With ends of bars shouldered and/or riveted or gorged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Welded steel wire fabric mesh weight not exceeding 4 Kgs per sqm fixed to wood or steel members complete all as specified and as directed.
Rolled mild steel work of angle iron as in frames of doors & Cup Board etc conforming to grade Fe 290 grade E-165 complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-1 (using 20mm graded crushed stone aggregates) for filling in the pressed steel door frame/hold fast complete all as specified and as directed.
Cutting holes exceeding 150 sq.cm but nexc 400 sq.cm in to brick walls built in CM 1:3 and making good in cement concrete 1:2:4 type B1 for fixing of cooler brackets etc. complete all as specified and as directed.
Mild steel cold rolled butt hinges medium weight 75 mm log fixed to steel /angle iron frame by welding, if required complete all as specified and as directed.
Mild steel, plain, 1.25 mm thick black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and as directed.
Hasp and staple, 100 mm size safety type aluminium anodised with mild steel hinges pin, including bolt to hinge plate and fixed with screws, complete all as specified and as directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and as directed by Engr-in-Charge.
4 mm thick figured glass (frosted) ,pin head type and glazing with oil putty not exc 0.50 Sqm in each pane fixing to window/ventilator complete all as specified and as directed by Engr-in-Charge.
Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1mm and fixed with tinned tacks, or galvanised wire staples complete, all as specified. (ISI Mark)
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
100 mm aluminium handles, cast type anodised complete all as specified and directed. (ISI Mark)
Aluminium drapory rods of 25 mm dia decorative type with wooden finish alongwith holding for brakets & end caps fix in repairs complete all as specified & directed.
Solid PVC door frame of size 50mm x 47mm made out of 5mm both side Prelam PVC sheet used instead of plain colour PVC Sheet and edge will be painted to match with prelam sheet. reinforced with M.S. Square tube, in opening as per specifiecation and drawings complete all as specified & directed.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed.
Preparation of wooden surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of zink chrome primer complete all as specified and as directed.
Preparation of old steel and iron surfaces exceeding 10 cms width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed.
Providing cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-0 complete all as specified and as directed.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 kg/Sqm including 10mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately). Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3.50 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete, all as specified and directed.
Viterous china wash basin, white flat back size 550 x 400mm including waste coupling CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia, fixed in repairs, complete all as specified and as directed.
Vitreous China urinals, half stall (back or corner wall type) white, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), fixed in repairs, complete all as specified and directed.
Water closet (Orissa pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs, complete all as specified and as directed.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed.
S&F Vitreous China wash down water closet pan and seat cover (pedestal pattern), coloured (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed.
Aluminium tubular towel rail, 20mm dia, D type, 60cm long between flanges aluminium anodized, fixed with rawl plugs, fixed in repairs, complete all as specified. (ISI Mark)
Steel peg set colour coated of six as per sample in repairs complete all as specified and as directed.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified and as directed.
S&F Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 75mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore, complete all as specified and as directed.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 50mm bore, complete all as specified and as directed.
Salt-glazed stoneware gully traps, size 150 x 150 mm, square or round mouthed, type 'P', including setting and jointing to drains with cement mortar 1:1, fixed in repairs, including demolition of old unserviceable gully traps complete all as specified (ISI Marks).
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 75mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed.
Cast iron bends (any radius diminishing pieces or tapes (larger bore measured), 100mm bore fitted with oval access door fixed with rubber ring joints as in repairs complete all as specified and as directed.
75mm Cast iron floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4), complete all as specified and as directed.(ISI Mark)
Cast iron branch pieces, single/double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 100 bore, fitted with oval access door as in repairs complete all as specified and as directed.
Cast iron branch pieces, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches 75 bore, fitted with oval access door as in repairs complete all as specified and as directed.
50mm Cast iron cowls as in repairs complete all as specified and as directed.
Cast iron Reducer 100mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Cast iron Reducer 75mm by 50mm for connecting and fixing gas pipe on walls as in repairs complete all as specified and as directed.
Taking down eaves gutters and and rain water pipes (any size or pattern ), including all fittings incl removal of store and sold to contractor through credit.
110 mm bore PVC SWR bends and fixed with joint sealent etc, complete all as specified and as directed by Engr-in-Charge.
110mm PVC (SWR) pipes single/Double socketed of any length with rubber ring joints pressure rating 4 kg/cm2 fixed to wall incl clamp etc, complete all as specified and as directed by Engr-in-Charge.
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 75 mm bore of pipe complete all as specified and as directed .
Stack clamps out of 50mm by 5mm flat iron and 6mm dia round iron stays,including bolts and nuts and securing ends of stays to wall or roof for 100mm bore of pipe complete all as specified and as directed.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundatiom, complete all as specified and as directed.
3mm thick wall care putty on walls including preparation. etc, complete all as specified and as directed.
Viterious china urinals half stall white incl CP urinal Spray Nozzal complete incl providing and fixing of plug bedding urinal against wall in cement motor 1:2 securing urinal to plug with and incl 60mm long brass screws pointing incl 60mm long brass complete all as specified and as directed.
Plain, Aluminium sheeting 0.56 mm thick , Alloy 31000 H4 in ridges, hips, valley gutter, drip ,construction joints and straight flashing (length and girth as fixed), fixed in repairs, complete all as specified.
Dismantling water tank of capacity exceeding 1000 litres but not exceeding 2000 ltrs each and removing from site/to store, complete all as specified and as directed.
Rotational moulded polyethylene water storage tank, two layers, inner and outer white, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 2000 litres each including all accessories {i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm (Minimum weight 210 gram) etc}, complete all as specified and as directed.
Bib taps, fancy type cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixed in repairs, complete all as specified and as directed.
Stop valves/Angle valve, fancy type chromium plated cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 15mm, fixed in repairs, complete all as specified and as directed.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, fixed in repairs, complete all as specified and as directed
Angle valves, cast copper alloy,screwed down,high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair, for 15mm dia of pipe complete all as specified and as directed.
Soap dish, vitreous China white, approximate size 160x 160x90mm, fixed in repairs, complete all as specified.
Shower roses 15 mm chromium plated with or without swivel joints, any size, including 125 mm long arm and fixing to steel pipe or union, complete all as specified and as directed.
Waste coupling of PTMT for 32mm dia discharge pipe (half or full threaded) (Minimum weight 32mm 45gms/ 40mm-60 gms), fixed in repairs, complete all as specified and as directed.
Waste fittings 32 mm , brass, chromium plated for glazed ware sinks, basins, etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
15mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
20mm bore galvanised steel water tubing medium grade (ISI Marked) with and including all fittings and fixed complete to walls and or laid under floors etc complete all as specified and as directed.
Refixing old steel water tubing medium grade galvanised and connections in new or old position (walls, ceiling, floor etc.), 15 mm bore, complete all as specified
Refixing old steel water tubing medium grade galvanised and connections in new or old position (walls, ceiling, floor etc.), 20 mm bore, complete all as specified
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Post anti-termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and as directed.
Post anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floor, complete all as specified and as directed .
Stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified and as directed.
Suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system) of grid size 600mmx600mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick high Pressure Non Asbestos Fiber Cement decorative Board (E-Board Classic) in a grid of GI systtem duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinkler, smoke detectors etc. The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. The last hanger at the end of each main runner should not be interlocked between main runners @ 610mm c/c, as to form 600 mm x 600 mm grid all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, complete all as specified and as direceted.
Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as direceted.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as direceted.
100mm thick PCC 1:4:8 Type D2 using 40 mm graded stone aggregates as in foundations filling and mass concrete., complete all as specified and as direceted.
Sand cushioning under floors including watering and consolidation complete all as specified and as direceted.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment. Shape shall be approved by GE.
Cement concrete in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles all as directed, 1:2:4 mix type B-1 complete all as specified and as directed.
Precast cement concrete block masonary with soild blocks, exc. 10cm in width and setting in cement mortar , kerbs stone all as directed, 1:2:4 mix type B-1 complete all as specified and as directed.
Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
Description all as per description of serial item No 130 here in before but except stone.
Precast cement concrete 1:3:6 type C1 using 20mm graded crushed stone agregate bonders for stone walling set in cement mortar 1:6 with plain fair faces including chamfers weathering etc complete all as specified and as directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints,, as specified , with maximum depression on face from straight edge n. exc 40mm for lime or sand stone, complete all as specified and as directed.
PVC (SWR) pipe, 110mm dia (ISI marked) in any length embedded in cement mortar for weep holes at locations complete all as specified and directed.
Raised pointing to random or polygonal rubble stone Masonry, uncoursed or brought upto courses, in cement mortar 1:4 complete all as specified and directed.
Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foudation, filling and mass concrete complete all as specified and directed.
Plain cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in surface channels and drains, complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
20mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of soil and getting out soil, complete all as specified and as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Demolition and breaking up drain pipes, 150mm internal dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar, including concrete bedding and haunching complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Reinforced concrete pipes 200mm bore ,class NP2,laid and jointed complete with coller all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as specified and as directed.
Brick work with sub class B bricks straight or curved on plan to any radius built in CM 1:6 but except bricks all complete all as specified and as directed.
Precast cement concrete type B1 1:2:4 using 20mm graded crused stone aggregate in landings, cover slab, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and as directed.
Rendering 10mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair without using extra cement complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm bore pipes, complete all as specified and as directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light /fan/ bell controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed.
All as per description of Serial item No 152 here-in-before but One light point controlled by two 2 - way switches.
All as per description of Serial item No 152 here-in-before but one 3 pin 5 Amp socket outlet point controlled by one push button on the same board.
All as per description of Serial item No 152 here-in-before but one 3 pin 5 Amp socket outlet point controlled by one push button on the independent board.
All as per description of Serial item No 152 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly.
Switch piano type 5 Amps single pole one way 240 volts complete all as specified and as directed.
Switch piano type 5 Amps single pole two way 240 volts complete all as specified and as directed.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type , complete all as specified and as directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed.
Fan regulator 120W, 230V 50 C/S, flush type electronic, step type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed.
Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor, having service value > 5.0 including making connection with and including suitable flexible copper wire, including taking down old exhaust fan and deposited to MES store, complete all as specified and as directed.
Exhaust fan, steel body AC single phase 230/240 V of size 300mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty including taking down old exhaust fan and deposited to MES store, complete all as specified and as directed.
Exhaust fan, steel body AC single phase 230/240 V of size 450mm sweep with louver speed 900-950 RPM power input 50-55 W, Heavy duty including taking down old exhaust fan and deposited to MES store, complete all as specified and as directed.
VTPN distribution board,vertically including MCCB 100 Amp , 16kA (as incommer) 4 way, double door IP-43 protection, fixed in repairs complete all as specified and directed. (Including all PCC & cementing work for installation of TPN DB to wall ).
MCB Four pole 40 Amp, 415V, 10KA, 'B' Curve, complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications , fixed in repairs complete all as specified and as directed. (Note: MCBs will be measurd separately).
MCB SPN, 40 Amps, 'B' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified.
MCB SPN, 32 Amps, 'B' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified.
MCB SP, 6 to 32 Amps, 'B' series 10 KA 240 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Sub main wiring with two runs of 10 Sqmm ( 2x10 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 10 Sqmm (1x10sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including taking down old sub main wire, complete all as specified. Note:- 2 runs of 10 Sqmm (2x10sqmm ) ,one run of 10 Sqmm (1x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, including taking down old sub main wire, complete all as specified and directed Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified. (For Geyser power point & cook house machine point) Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 2.5 Sqmm ( 2x2.5 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 2.5Sqmm (1x2.5sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed. (For Bldg security light) Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.
Earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 25 x 4 mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- All the joints shall be made with welding to get proper conductivity. Note: On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge
New generation energy saving and environmental friendly long life LED street light of 30 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and as directed. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 40mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , complete all as specified and as directed.
LED decorative down light fitting/ recess mounted panel (2' x 2') surface mounted lighting fixture 36 Watt LED, with diffuser, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED (Make of LED shall be Cree/Nichia/Osram) complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as specified and as directed.
LED tube light fitting Garnet 20W Batten LED, housing made of extruded AL with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old, complete all as specified and as directed.
LED tube light fitting Garnet 10W Batten LED, housing made of extruded AL with lumen O/P should not be less than 100 lum/watt making all connection using flexible cable of suitable size from ceiling rose to fitting including taking down old, complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 02 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, single door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Removing and refixing only LED lights fitting 5 Watt to 20 Watt any pattern and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and as directed.
Removing and refixing electric water heater, anmy type and capacity, complete all as specified and as directed.
XLPE insulated sheathed armoured heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 4 core and testing, including taking down of old cable, complete all as specified and as directed.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat of size 230mmx115mmx75mm complete all as specified and as directed.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed.
ON load change over switch (side handle) 63 Amps 4 pole in sheet enclosure 415 Volt, complete all as specified and directed.
khajuria builders
M/S ASHOK KUMAR PACHIALA
jyoti parkash sharma
SINGH CONST CO
M/S Inderjit Sharma and Co.
R K BUILDERS
M/S VED PARKASH GUPTA
RAJINDRA ENGINEERS & CONTRACTORS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .