Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC 306 BAKSHI HOUSE 40 41 NEHRU PLACE NEW DELHI 110019 DELHI | SOUTH EAST | DELHI | 110019 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.6 L+₹68,435 (6.90%)Rejected-Finance 6 NEW SADGURU NANIK INDUSTRIAL ESTATE OFF WESTERN EXPRESS HIGHWAY GOREGAON E MUMBAI 400063 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | L2 | Rejected-Finance L2 | |
| 3 | L3₹10.7 L+₹73,976 (7.46%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹10.7 L+₹76,875 (7.75%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | L4 | Rejected-Finance L4 | |
| 5 | L5₹10.8 L+₹87,525 (8.82%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L5 | Rejected-Finance L5 |
Tender Value
Refer Docs
Closing Date
5 Feb 2021, 5:00 pmClosed
AGM (E-E)-II
Asst. General Manager (Engg-Elect), Airports Authority of India, Southern Region, Operational Offices, Chennai Airport, Chennai 600 027
Replacement of AC units at ATS Complex, Admin Building, Operational Area/MSSR Porur/WT Station at Southern Region, Chennai Airport
2021_AAI_67835_1
AAI/RHQ/SR/ENGG/AGM(E)/AC WORK/2021
Open Tender
Electrical Works
Item Rate
90 days
Chennai Airport
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
Exempted
4 Mar 2021
29 Jan 2021
8 Feb 2021
29 Jan 2021
5 Feb 2021
29 Jan 2021
29 Jan 2021 - 4 Feb 2021
SH I : Supply of Airconditioning Units
Supply of single phase, 1.5 TR Split type Air conditioner of High wall mounting inverter type of BEE 5 star rated consisting of non-ductable single room evaporator unit(copper coil) with cordless remote control and one number outdoor condensing unit comprising of sealed type rotary compressor suitable for operation on 230V, 50Hz. AC supply capable of performing cooling, Air-Circulating, filtering, wall brackets and comprising of the following including first charge of refrigerant (R-410A/R-32), facilty of having auto-restart type without changing of existing setting etc., as required. i) 1" PVC Drain pipe insulated with suitable insulation or as per OEM Specification (upto 3 meters). ii) 1/2" dia copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM Specification (upto 3 meters). iii) 1/4" dia copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM Specification (upto 3 meters). iv)Suitable power and communication cable or as per OEM Specification (upto 3 meters). v) Rigid PVC pipe / PVC Trunking of suitable size for covering all the above in (i), (ii), (iii) & (iv).
Supply Installation,Testing and Commissioning of 3 phase, minimum 3 TR ceiling mounted inverter type cassette unit along with panel consisting of non-ductable single type four way / round type flow indoor unit (fan coil) with cordless remote control and one number outdoor copper condensing unit comprising of scroll/rotary/ swing type compressor suitable for operation on 415V, 50Hz. AC supply capable of performing cooling, Air-Circulating, filtering, wall brackets, with proper drain water pumping mechanism and comprising of the following including first charge of refrigerant (R-410A/R-32), facilty of having auto-restart type without changing of existing setting etc., as required
Supply, installation, testing and commissioning of 3 phase, 3 TR Floor Standing Vertical inverter type Air conditioner consisting of non-ductable single room evaporator unit(copper coil) with cordless remote control and one number outdoor condensing unit comprising of sealed type scroll/rotary compressor suitable for operation on 415V, 50Hz. AC supply capable of performing cooling, Air-Circulating, filtering, wall brackets and comprising of the following including first charge of refrigerant (R-410A/R-32), facilty of having auto-restart type without changing of existing setting etc., as required.
Supply of 4 KVA Voltage stabilizer wall mounting type suitable for 1.5 TR split A/C units with input voltage range 170V to 270 V & output 220 ±10% etc., as required.
SH II : ITC of Airconditioning Units
Installation, testing and commissioning of single phase 1.5 Ton split airconditioner of high wall mounting type with minimum 5 star rating including fixing the condenser unit on raising stand and fixing of evaporator unit including providing and making inter connections between evaporator unit and condensor unit up to a length of 3 mtrs etc. as required.
Supply and fixing of following for interconnections between evaporator unit and condensing unit (extra length) for 1.5 ton Ac, as required as per OEM. i. 1" PVC Drain pipe insulated with suitable insulation or as per OEM Specification ii.1/2" dia copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM Specification. iii. 1/4" dia copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM Specification iv. Suitable power and communication cable or as per OEM Specification . v. Rigid PVC pipe / PVC Trunking of suitable size for covering all the above in (i), (ii), (iii) & (iv).
Supply and Fixing of following for interconnections between evaporator unit and condensing unit , as required for minimum 3 TR inverter cassette type AC Units / 3TR inverter floor standing vertical AC unit. 1) 5/8" dia copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM specification. 2) 3/8" copper pipe insulated with nitrile rubber insulation of 19 mm thick insulation or as per OEM specification. 3) Suitable communication and power cable or as per OEM specifications. 4) Rigid PVC pipe / PVC Trunking of suitable size for covering all above in (1), (2) and (3) above.
Supply and fixing of required additional drain pipe suitable for 1.5 TR AC complete as required.
Supply and fixing of suitable drain pipe for 3 TR AC complete as required.
SH III : Dismantling of Airconditioning Units
Dismantling of Single Phase, 1.5 TR rated Split type Airconditioner indoor unit, out door unit, disconnecting the refrigerant pipes, electrical connections including gas pumping down & shifting to location as per the instruction of EIC, etc., complete as required.
Dismantling of 3 Phase, 3 TR rated Cassette/Vertical type Airconditioner indoor unit, out door unit, disconnecting the refrigerant pipes, electrical connections including gas pumping down & shifting to location as per the instruction of EIC, etc., complete as required.
PREMIER ENGINEERING TECHNICS PVT. LTD.
TRAC FUJICO AIR SYSTEMS LLP
Ganga Enterprises
LAKSHMI ELECTRICAL ENTERPRISES
star refrigeration sales and service
DElite System Engineering (India) Pvt. Ltd.
CHENNAI ENGINEERING SERVICES
DEEPAKELECTRICALS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .