| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC PLOT NO 26 1ST FLOOR PRATAP NAGAR NEAR JAIL ROAD NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹14.4 L+₹27,429 (1.94%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹17.3 L+₹3.1 L (22.1%)Rejected-AOC B 101 3RD FLOOR JHILMI COLONY DELHI 110095 | DELHI | EAST DELHI | DELHI | 110095 | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹18.0 L+₹3.8 L (27.1%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 |
Tender Value
₹19.9 L
EMD Value
₹39,700
Closing Date
2 Mar 2023, 6:00 pmClosed
GE EM RR HOSPITAL
GE EM RR HOSPITAL DELHI CANTT 10
SPL REPAIR TO ENDO DEPT DENTAL LAB AND QM OFFICE AT ADC UNDER GE EM RR HOSPITAL DELHI CANTT 10
2023_MES_577680_1
GE/H-46/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE EM RR HOSPITAL DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹39,700
Yes
17 Mar 2023
28 Jan 2023
4 Mar 2023
28 Jan 2023
2 Mar 2023
16 Feb 2023
Amount
Taking down cement plaster of any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
M&L for 15mm thick rendering on brick or concrete wall surfaces in cement mortar 1:6, finished the surface fair and even, complete all as specified & directed.
M&L for applying two layers of wall care putty on newly plastered surface of walls and making the surface even & smooth for receiving distemper/ paint of any description, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of plastic emulsion paint over a coat of primer, complete all as specified & directed.
M&L for preparation of old plastered or unplastered surfaces of walls including sides and soffits of beams, facias, parapets etc, by washing, rubbing down and stopping of painted surfaces and applying two coats of plastic emulsion paint, complete all as specified & directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing) and rubbish off the premises, complete all as specified & directed.
M&L 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor finishes, complete all as specified & directed.
M&L 10 mm thick screed bed or bedding layer in cement mortar (1:4) to receive wall tiles, complete all as specified & directed.
M&L for vitrified ceramic coloured tiles 8 to 9 mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified & directed.
M&L for vitrified ceramic coloured tiles 8 to 9 mm thick (square/ rectangular) polished of light shade, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified & directed.
Supplying, fabricating & fixing in repairs of aluminium door shutters with powder coating (minimum thickness of powder coating 50 micron), vertical stile of door shutter of size 85mm x 44.45mm x 1.5mm thick, top, middle and bottom rail of size 85mm x 44.45mm x 1.5mm thick and fixing plain/ tinted sheet glass or ACP sheet with aluminium beading and rubber gasket/ beading as directed. One mortice lock for aluminium door (each) and three nos aluminium hinges of size 100mm and two nos aluminium tower bolts of 150mm size for each door fixed with rawl plug includimg rectification of floor/ wall to match the existing surface, complete all as specified and directed by Engr-in-Charge. Note: (Cost of sheet glass/ ACP sheet shall be measured and paid seperately).
Supply only 5.5mm thick glass (plain or tinted) complete all as specified & directed.
Supply only 5mm thick aluminium composite panel (ACP) sheet, complete all as specified & directed.
S&F 150mm size aluminium alloy handles, cast type, anodised, complete all as specified & directed.
Supplying, fabricating & fixing in repairs of aluminium powder coated glazed three track sliding window of frame 92mm x 31.75mm x 1.50mm and sliding shutter of section 40mm x 18mm x 0.91mm thick including 4mm thick sheet glass, ordinary quality exceeding 0.50 Sqm in each pane, in two track shutter and in one track stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, all fittings such as aluminium handle of size 100mm and locking arrangement with each moving leaf, complete all as specified & directed by Engr-in-Charge.
Supplying, fabricating & fixing in repairs of aluminium partition wall of aluminium section 100mm x 44mm x 1.5mm thick frame rectangular section and panel of ACP sheet or pre-laminated board in bottom panel and 5.5mm thick glass in top panel with rubber lining and aluminium beading around length including necessary fixing arrangements for bottom and top member of aluminium frame in floor/ PCC/ Brick work as per site requirement with rawl plug etc, including chromium plated steel screws 60cm centre to centre, complete all as specified and directed by Engr-in-Charge. (Note: Cost of ACP sheet or pre-laminated board and frosted glass shall deemed to be included in the rate quoted for this item).
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, fillets etc & existing electrical wiring, and removal of debries from site complete all as specified & directed.
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, all as specified & directed.
M&L for gypsum board 12mm thick in ceiling/ seamless ceiling fixed with screws of any type & pattern including applying two coats of cement base wall care putty on ceiling and applying two coats of oil bound distemper including necessary taping of joints etc, complete all as specified & directed by Engr-in-Charge.
S&F solid PVC wall panelling consisting of 5mm thick wood grain finish PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications, complete all as specified & directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and complete all as specified & directed.
S&F solid PVC lipping of 2mm wood grain finish PVC sheet is heat bent as as liping on the edges of doors, windows & other edges inclusive solvent cement and fixing at site, complete all as specified & directed.
S&F in repairs brass CP single lever sink mixture with swinging spout on upper side (wall mounted) with connecting legs & wall flanges suitable for 15mm bore dia pipe, complete all as specified and directed.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling rose, holder, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete all as specified & directed.
Taking down existing sub main wiring aluminium/copper 4/6sqmm complete all as specified & directed.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/ fan/ exhaust point controlled by one, one way switch 06 Amps.
All as per srl item No 26 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch.
All as per srl item No 26 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch.
All as per Serial Item No 26 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete all as specified and directed.
S&F in repair modular switch, 06 Amps, single pole, one way, 250 volts, one module and IP 20 protection complete all as specified & directed.
S&F in repair modular switch, with indicator, 16 Amps, single pole, one way, 250 volts, one module complete all as specified & directed.
S&F in repair modular socket outlet 05 Pin, 06 Amps, 02 module with shutter complete all as specified & directed
S&F in repair modular socket outlet 02 in 01, 03 pin, 06 Amps and 16 Amps, 02 module with shutter complete all as specified & directed
S&F in repair ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, 02 module, humfree, AC, 230 volts, 100 watts, duly ISI marked complete all as specified & directed.
S&F in repair surface/ ceiling mounted LED panel type of size 2ft x 2ft, 36W, 230V, 5700K complete with driver having precisely designed decorative PMMA diffuser LED panel with CRCA powder coated white housing complete with all accessories required for connection and making good the disturbed ceiling complete all as specified & directed.
M&L Sub main wiring concealed with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FR multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 12 Way with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
All as per srl item No 37 here-in-before but 8 Way.
S&F in repair MCB SPN, AC, 240 volts of 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.
Supply and fix in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 20 Amp capacity and PVC gang box etc, complete all as specified and directed by Engineer-in charge.
ACR ENTERPRISES
BEHAL TRADERS
sony engineering works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .