| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹22.5 L+₹1.1 L (5.14%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹23.9 L+₹2.5 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹24.4 L+₹3.0 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹25.6 L+₹4.3 L (20.1%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
24 Apr 2024, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
SPECIAL REPAIR TO CAMERO GUEST ROOMS RECREATION ROOM AND CIVILIAN SPORTS CLUB AT CAMERO COMPLEX
2024_MES_649271_1
GE/SP/ TOKEN-89/2023-24
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹87,200
Yes
30 Aug 2024
4 Apr 2024
26 Apr 2024
4 Apr 2024
24 Apr 2024
19 Apr 2024
Amount
Demolition of brick work or stone/boulder masonry built in cement mortar complete all as specified and directed by Engr In Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed by Engr In Charge.
Taking down cement plaster on brick or concrete surfaces, parapets including raking out joint, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L for rendering CM (1:6) 10 mm thick on fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement including taking down cement plaster complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and fair without using extra cement complete all as specified and directed by Engr In Charge.
M & L rendering 5mm thick on ceiling in cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed by Engr In Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) area exc 1.5 sqm and not n.exc 4.0 sqm (including make good with CM 1:4 and hold fast) complete all as specified and directed by Engr In Charge.
M & L for cement concrete type C1, 1:3:6 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including ar- rangement for fixing of hinges and fixtures as required complete all as specified and directed by Engr In Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheet PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification complete all as specified and directed by Engr In Charge.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick 3D wood grain Moulded PVC Sheet Polyurethane painted on the front face & 2mm prelam PVC Sheet on back face complete all as specified and directed by Engr In Charge.
S&F 150mm long Aluminium anodised, barrel tower bolts of ex- truded section and fixed complete and specified and directed by engr-in -charge.
S&F 150mm long aluminium handle cast type polished bright complete and specified and directed by engr-in -charge.
S&F 100 mm long butt hinges medium weight, stenless steel, and fixed complete and specified and directed by engr-in -charge.
S&F for 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete and specified and as directed by engr-in -charge.
S&F for Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete and specified and as directed by engr-in -charge.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete and specified and as directed by engr-in -charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and by Engr In Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed by Engr In Charge.
M & L for Glazed ceramic coloured tiles of size 350x 250x 7mm/ 450X 350X 7 thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles and including 10 mm thick backing coat in CM (1:4) Complete all as specified and directed by Engr-in-Charge.
M&L for vitrified coloured ceramic tiles, 9 to 10mm thick (Square/rectangular) area of each tile n.exceeding 0.36 sqm in floors/wall etc, set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over 15 mm thick screed bead in CM 1:4, complete all as specified and directed by Engr-in-Charge.
All as per item No above but as in skirting/ dado etc with and including 10mm thick backing coat in cement mortar 1:4 on wall complete all as specified and as directed.
M & L PCC 1:4:8 type D2 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone aggregate) complete all as specified and directed.
S&F in repairs soap dish, Stainless steel approximate size 160x160x90mm fixed to plugs with chromium plated brass screws etc complete all as specified and directed by Engr In Charge.
S & F in repair 25 mm dia anodised aluminium alloy with powder coated curtain rod including all necessary fixing arrangement like clamps, end brackets, end to end bracket and eight nos rings per meter complete all as specified and directed by Engr In Charge.
M&L for preparation of new plastered surfaces of walls, and applying two coats of distemper oil emulsion over a coat of alkali resistant primer including 3 mm thick wall care putty specified and as directed by engr-in -charge.
Complete removal of existing treatment on walls and applying two coat of approved shade of oil emulsion distemper over a coat of alkali resistant primer including 3 mm thick wall care putty all as specified and directed by Engr-in-Charge.
M&L preparation of new plastered or unplastered surface and applying three coats of white wash on ceiling complete and all as specified and directed by engr-in -charge.
M & L preparation of old plastered surface and applying two coats of white wash on ceiling complete and all as specified and directed by engr-in -charge.
Material & labour for preparation of new plastered surfaces and applying two coat of exterior grade modified antifungal water based weather proof acrylic emulsion dirt cleaning property paints on wall, fins, facias, chajjas over a coat of primer and complete all as specified and as directed by the Engr-in-Charge.
Taking down steel tubing or removing from site of 15mm bore pipe all as specified and directed by Engineer-in-charge.
All as per item no 32 above but 20mm bore.
S&F for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
All as per item no.34 above but 20mm bore
Dismantling water tanks exc 250 but not exc 500 ltrs capacity and removing to store complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 500 Ltr water storage tanks as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings complete all as specified and as directed by Engr-in-Charge.
S &F in repairs for 20 mm dia Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass errule and fixed complete all as specified and directed by Engr In Charge.
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors etc complete all as specified and directed by Engr In Charge.
All as per item no.42 above but 75 mm dia..
S&F for PVC SWR vent cowl of size 110 mm complete all as specified and directed by Engr In Charge.
S&F in repair vitreous china squatting pan “orrisa” pattern of size 580mmx440mm “white” with integral foot rest (excluding flushing cistern and flush pipe) incl provision of cement concrete bedding, ‘P’ trap 100mm dia connection to trap , anti-syphonage complete all as specified and directed by Engineer-in-charge. Make : Hindware/Parryware/cera.
S&F in repair for vitreous china wash down water closet pan, white (pedestal pattern), including plastic water closet seat, black/white, closed pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device, excluding fixing bolts, flushing cistern and flush pipe) complete all as specified.
S&F in repairs10 ltr capacity PVC flushing cistern coloured with accessories Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete and specified and directed by engr-in -charge.
S & F in repairs for 125mm dia Steelness steel grating doom with waste hole/without waste hole for waste pipe ( minimum weight 40 gram) complete all as specified and directed by Engr In Charge.
S&F in repair gun metal globe balve or gate valve with mild steel iron wheel head, screwed both ends for iron pipe & fitted for 20 mm bore complete all as specified and directed by Engr In Charge.
S/F in repairs 15 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated with long shank and cup (concealed type)all as per specified and directed by Engr-in-Charge.
S & F in repairs 15mm CP bib tap fancy type copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe etc complete all as specified and directed by Engr In Charge.
S&F in repairs pillar tap, fancy type,cast copper alloy, chromium plated, with capston heads screwed down, high pressure with or without lettered hot or cold with long screwed shames and fly nuts, screwed for 15mm bore pipe
S & F for 15 mm bore brass CP wash hand basin mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs PVC cabinet mirror of size 470 mm x 570 mm x 120mm complete all specified and directed by Engr-in-Charge.
M&L in repair PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engr In Charge.
M &l for removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash hand basin of size 550mm x 400mm white, flat back including angle iron brackets with two coats of synthetic enamel paints including PVC waste pipe of 32mm dia of suitable length, PVC connection of 15mm dia & 450mm long with PTMT nuts, and 32mm dia brass waste fitting complete all as specified.
S&F in repairs for 15 mm dia Chromium plated stop valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by Engr In Charge.
S&F in repairs chromium plated shower rose 125 mm size with or without swivel joints complete all as specified and directed by Engr In Charge.
S&F in repairs CP tubular Towel rail , 20 mm dia, D Type 600mm long between flanges brass chromium plated with screws and cleats, (Minimum weight 190 gms) complete all as specified and directed by Engr In Charge.
S&F 15mm dia PVC Connection 450 mm long with nuts complete all as specified and directed by Engr In Charge.
M & L for complete removal of existing roof treatment with mud faska including bedding layer in cement mortar complete all as specified and directed by Engr In Charge.
M&L for Providing, cement concrete type B-0 1:2:4 (12.5 mm graded aggregate) in roof kerbs or mud stops, padding, rounded or chamfered on edges without using extra cement complete all as specified and directed by Engr In Charge.
M&L for 10 mm thick cement mortar 1:4 on fair faces of brick or concrete surfaces with integrlal water proofing compound as per manufacturers instructions complete all as directed and specified. Note : WPC shall be paid and measured seperately under relavent item
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Laying of 3mm thick prefabricated APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 170 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. Note:- This treatement shall be done by the approved authorized applicators and guarantee of treatement shall be minimum 10 years complete all as specified and directed by Engr In Charge.
M&L for cement concrete tiles 20cmX20cmX20mm machine pressed, set jointed and pointed in neat cement slurry in floors, and cut and polished over 15mm screed bed in CM(1:4) complete all as specified and directed
Supply only integral water proofing compound as per manufactures instructions complete all as specified and directed by Engr In Charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
Material and labour for false ceilings using GI snap grid system with roll-formed out of hot dip galvanised steel caping (powder coated) main runner 38 x 24 mm , cross Tee 29 x 24 mm and wall angle 24 x 24 mm members suspended with 4mm dia GI wire, carry maximum load up to 8.10 Kg/Sqm with 4mm thick designer ceiling board , pre painted Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions size 595 x 595mmx 4mm thick any texture (Lake and Hill, oceaniccascade or Electra) as approved by GE.
Dismantling of aluminium door, partition, window & ventilator including all necessary fittings complete all as specified and as directed
S&F aluminium coloured powder coated door shutters, aluminium section weighing min 0.55 Kg/m including necesssary joining cleats, glazing clips, rubber neoprene packing handles 2 Nos in each door, pad lock, hinges, anodised aluminium snap beading screws etc complete all as specified and directed. (Thickness of power coated not less than 50 micron).
S&F aluminium coloured powder coated window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necesssary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc, complete all as specified and directed. (Thickness of power coated not less than 50 micron).
S&F 12mm thick particle board prelaminated on both sides as in panel of door shutters partition wall, work stations including beading etc.omplete all as specified and directed by Engr-in-Charge.
S&F Aluminium(extruded section body) Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as directed and specified.
S&F for double action floor spring hydraulically regulated mode lap of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to shutter complete all as specified and directed by Engr-in-Charge.
S&F brass body Mortice lock, vertical type,size 100 mm 4 lever, incl escutcheon plate and two No keys fixed complete all as specified and directed by Engr-in-Charge.
S&F 5.5 mm thick plain or tinted glass, ordinary quality including rubber gasket for packing and fixed to aluminium doors/window/partition incl necessary cutting / moulding and chamferring of edges for service window/counters complete all as specified and directed.
M &L for PVC profile for wall panelling colour / shade as approved size 250mm wide, 08 mm over all thick with 1 mm wall thickness fixed with screw to mild steel square ( size 20mmx 20mmx 1mm thick) tubler frame work including one coat of red oxide primer, fixed to walls and including dismentling complete all as specified and directed by Engr-in-Charge.
M&L for PVC profile corner beading L/T type for wall panelling, colour/shade matching with wall panelling complete all as specified and directed by Engineer-in-Charge.
S&F vertical roller blinds made out of nylon cloth of any colour as approved including hanging arrangement rollers etc complete as specified and directed by Engineer in charge. Make : VISTA or equivalent.
Dismantling of corrugated steel sheeting any gauge, thickeness including nainital or similar roof coverings complete all as specified and as directed.
S & F moulded pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified.
S & F moulded pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in eaves sheeting /cladding to wall, fixed with self tapping screws as specified.
S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 grade St-240
M & L for preparation of new steel surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer.
Preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L PCC coping (1:2:4) type B-0 using 12.5mm graded stone aggregate as in coping including necessary form work, including weathering, slightly rounded or chamfered angles and throating as directed.
Demolition of cement concrete in ground floor and paving n/exe 15 cm thick below or above GL
M&L for 75 mm thick, PCC 1:3:6 type C-2 as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
M&L 75mm thick Plain cment concrete C2, 1:4:8 (using 40mm graded stone aggregate as sub base of floors or foundations complete all as specified.
M&L for sand filling under floor in foundations inclding watering and consolidation complete.
M&L for coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15656 -2006 of 60 mm thick M-35 with grey cement and pigment all as specified and directed.
Demolition and breaking up drain pipes 100mm dia salt glazed stone ware AC or rein forced concrete pipe set in cement mortar including removal from site complete all as specified and directed by Engr-in-charge
Demolition and breaking up drain pipes 200mm dia salt glazed stone ware AC or rein forced concrete pipe set in cement mortar including removal from site complete all as specified and directed by Engr-in-charge
Excavation in hard /dense soil in trenches not exc 1.5 m wide and not exc 1.5m depth and getting out, complete all as specified and directed by Engr-in-charge.
Excavation in hard/dense soil in trenches not exc 1.5 m wide and exc 1.5m but not exc 3.0m depth and getting out complete all as specified and directed by Engr-in-charge
Demolition of brick masonry built in CM complete all as specified and directed by Engr-in-charge.
M&L for Cement concrete in foundations, filling and mass concrete type C2 1:3:6 (40mm graded aggregate) complete all as specified and directed by Engr-in-charge.
M&L for brick work with sub class 'B' bricks, straight of curved on plan exc 6M mean radius built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement with water proofing compound complete all as directed and specified.
S&F 100 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers/other jointing materials as per manufacturers instructions, laid in trenches or in floors all as specified and directed.
S&F 200 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length including all fittings and jointing with elastomeric rubber rings and couplers/other jointing materials as per manufacturers instructions, laid in trenches or in floors all as specified and directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed . complete all as specified and directed.
Returing, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge.
M&L for PCC Type B-1 (1:2:4) using 20mm graded stone aggregate) as in man hole, surface channel and drain complete including finished surface.
S&F in repair factory made SFRC manhole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick incl MS sheet 2 mm thick all around the cover including demolition of cover, complete spefcified and directed by Engr - in - charge.
M&L for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers and similar articles including dismantling of old CI cover complete all as specified.
M&L for concrete bed PCC 1:4:8 type D2 (using 40 mm graded stone aggregate ) to drain pipes 100 mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed by the Engr-in Charge
M&L for concrete bed PCC 1:4:8 type D2 (using 40 mm graded stone aggregate ) to drain pipes 200 mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified and as directed by the Engr-in Charge
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC concealed conduit, medium grade, ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including Tee, Junction boxes and provision of pressed steel terminal modular box powder coated of suitable size for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified for light/fans/bell controlled by one well push Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item No-112 above but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No-112 above but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 112 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size all as specified and directed by Engineer-in-Charge.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 2 or 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing wall mounted LED batten extruded aluminium heat shrink provided for efficient heat dissipation and integrated electronic driver ,10 watt LED fitting with 100 lumen/watt, 6000K , 230 Volts, diffused optics ,etc complete with all accessories , connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting, and testing complete all as specified and directed by the Engineer- In- Charge.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers
S&F in replacement of wall mounting fan heady duty 450 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
M & L for in replacement submain wiring with two run of 6.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 6.0 Sqmm single core and one run of 6.0 sqmm single core cable.
M & L for in replacement submain wiring with two run of 4.0 sqmm single core PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 4.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductordrawn through and under suitable size of rigid non metallic PVC conduit , medium grade, ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cable complete all as specified - 2 Runs of 4.0 Sqmm single core and one run of 4.0 sqmm single core cable.
Taking down unserviceable submain wiring of alluminium two runs of any size cable including batten/conduit complete etc and making good distrub surfaces complete all as specified and directed.
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 125 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 40/63 Amps =01 No MCCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 4 way 230 volts double door type complete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Taking down old unsv MCB DB of any size.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Supply and fix in replacement of fixed thermal and fixed magnetic settings, 4 pole MCCB 100 Amps, 50 HZ, 415 volts with rupturing capacity 16 KA complete all as specified and directed by Engineer-in-charge.
Taking down unserviceable SP/SPN MCBs of any capacities from the MCCB DBs /MCB DBs after disconnecting the electric supply,complete all as specified.
S&F MCB SP 5 to 32 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
S&F MCB SPN 40 Amps 10 KA, 240 volt 50 HZ 'C' Series all as specified and directed by engineer-in-charge.
Hindustan Co.Co
GIR RAJ BUILDERS
shakti construction
Ashish Sehgal and Co.
M/S MG GROUP
SURESH KUMAR SHARMA & CO
deepankar trading co.
Laxmi traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .