Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2,264Accepted-AOC | L1 | Accepted-AOC AOC GOES TO SHREE ENTERPRISES BULDANA AWARDED VALUE FOR SINGLE LED STREET LIGHT 30 WATT IS RS 2264.000 AWARDED VALUE AND BILL VALUE MAY BE CHANGE DUE TO PURCHASING OF ITEMS QUANTITY | |
| 2 | L2₹2,265.52+₹1.52 (0.07%)Rejected-AOC | L2 | Rejected-AOC AOC GOES TO SHREE ENTERPRISES BULDANA AWARDED VALUE FOR SINGLE LED STREET LIGHT 30 WATT IS RS 2264.000 AWARDED VALUE AND BILL VALUE MAY BE CHANGE DUE TO PURCHASING OF ITEMS QUANTITY | |
| 3 | L3₹2,273.60+₹9.60 (0.42%)Rejected-AOC | L3 | Rejected-AOC AOC GOES TO SHREE ENTERPRISES BULDANA AWARDED VALUE FOR SINGLE LED STREET LIGHT 30 WATT IS RS 2264.000 AWARDED VALUE AND BILL VALUE MAY BE CHANGE DUE TO PURCHASING OF ITEMS QUANTITY | |
| 4 | L4₹2,315.76+₹51.76 (2.29%)Rejected-AOC | L4 | Rejected-AOC AOC GOES TO SHREE ENTERPRISES BULDANA AWARDED VALUE FOR SINGLE LED STREET LIGHT 30 WATT IS RS 2264.000 AWARDED VALUE AND BILL VALUE MAY BE CHANGE DUE TO PURCHASING OF ITEMS QUANTITY |
Tender Value
Refer Docs
EMD Value
₹7,500
Closing Date
27 Aug 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SARPANCH/SACHIV
GRAMPANCHAYAT YEWTA TQ CHIKHALI DIST BULDANA
REGARDING SUPPLY OFLED STREET LIGHT 30 WATT WITH TWO YEAR ONSITE REPLACEMENT WITHIN 4 DAY WARRANTY AT GRAMPANCHAYAT YEWTA TQ CHIKHALI DIST BULDANA
2020_BULDH_604754_1
E-TENDER NOTICE 01/led/2020-21
Open Tender
Electrical Goods
Item Rate
365 days
GRAMPANCHAYAT YEWTA TQ CHIKHALI DIST BULDANA
AS PER NIT
2 documents required · 2 mandatory
₹1,500
Yes
Online Payment
₹7,500
Yes
28 Aug 2020
21 Aug 2020
28 Aug 2020
21 Aug 2020
27 Aug 2020
21 Aug 2020
370 days
LED STREET LIGHT ISI MARK WITH TWO YEAR ON SITE WITHIN 4 DAYS REPLACEMENT WARRANTY AS FOLLOWING SPECIFICATION
ELECTRICAL EFFICIENCY Input operating Voltage range and frequency 90 to 300 Volts AC at 50 Hz+/-2 Automatic Higher Cut off voltage above 300 volt Yes Rated voltage 230 V AC 50 Hz AC Power Factor at full load ≥ 0.95 Driver Efficiency (in %age) Upto 100W: ≥85%, Above 100W: >/=90% Yes Total Harmonics Distortion ≤ 10 "The total circuit power shall not be more than 110 percent of the value declared by the manufacturer (as per Cl. 8 of IS:16104:2012 lates)" Yes OPTICAL LED chip Efficacy ≥130 Lm/Watt Colour temperature 6000+/-500K Working life for LED (Minimum 50,000 burning hours as per LM-80 and LM 21 reports) Yes Colour Rendering Index(CRI) ≥70 LED Beam Angle ≥120 Optic lense materal (UV stabilised) Poly carbonate lense THERMAL MANAGEMENT Heat sink should be die-cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes Junctiojn / Soldering point temperature shall not exceed 85 deg.c as per LM 80 report Yes Capacitor shall be rated for a temperature of 105 deg. celsius or better Yes Operating temperature range -10 deg C to +50 deg C Operating Humidity Range 10 % to 95% RH PROTECTION Short circuit Protection Yes Over load protecton Yes Over Voltage protection Yes Reverse polarity Yes High voltage test (1.5 KV for one minute between supply terminals and body of the unit) Yes Insulation resistance between earth and current carrying part >100 M Ohm The luminaire shall be protected against surges and transients ( Internal) >/=5KV The luminaire shall be protected against surges and transients of >/=10KV (External) Yes CONSTRUCTIONAL The Luminaires casing/housing (single piece housing) shall be pressure die casted aluminium alloy with higher thermal conductivity Yes The luminaire body must be corrosion resistant powder coated Yes All fastners must be of stainless steel Yes Protection of the entire housing (both LED section and driver section) as per IS:10322 (Part 1):1982 latest IP66 Extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the UV Glass cover and the metal housing to exclude the entry of the dust, water, insects etc., Yes Luminaries light transparency should be of Toughened glass Yes Toughned transparent glass cover thickness >/=4 mm Toughned Glass shall not get discoloured shall not suffer degration due to heat and ageing within warranty period Yes Number of electronic control gear (power supplies) 1 No. Light Source SMD LED Chip as per LM 80/IS16106 Driver components shall be industrial grade or above Yes PCB shall be FR4 grade minimum 0.8 to 1.0 mm thick or more Yes The Luminaires works on single phase three wires system (Phase, Neutral and Earth) Yes
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .