Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹43,600
Closing Date
6 Sept 2024, 3:00 pmClosed
Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division UdhampurJPDCL
INSTALLATION OF TRANSFORMER HT LT LINE
2024_PDD_257830_1
ED/Udh/18 of 2024-25 dt. 16-08-2024
Open Tender
Electrical Works
Turn-key
90 days
in district udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹43,600
14 Oct 2024
16 Aug 2024
7 Sept 2024
16 Aug 2024
6 Sept 2024
16 Aug 2024
16 Aug 2024 - 31 Aug 2024
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11 KV line on 9 mtr long ST poles, 30 mm sq. ACSR Weasel Conductor for Shifting of Transformer near h/o Thakar dass towards Shiv Temple alongwith accessories W.No. 1, Pyt Bhugtrian Block Chanunta under PRI Grants
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
120mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP-33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
8 mtr. Long ST Pole (ST-410 SP-15)
GI M Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
LT fabricated switch with aluminium busbar.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 9 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for creation of 25 KVA Sub Station at W.No. 03 Pyt. Birnoo under PRI Grants.
9 mtr. Long ST pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
30mm² ACSR Weasel Conductor
11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of 25 KVA Sub Station at W.No. 03 Pyt. Birnoo under PRI Grants.
11/0.433 KV, 3-phase distribution Transformer 25 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound, & with LV Cable box having detachable Aluminium Gland plate
Gapless surge Arrestor, 9 kv, 10 KA , LA with polymer housing stn. Type
11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical
11 KV Horn gap fuse set 3 phase 200 A
70mm² 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
9 mtr. Long ST pole (ST-410 SP-33)
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
GI Channel /Angle/flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mm for connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover
11 KV Poloymer composite pin insulator, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Danger Plates with Clamps
GI Barbed wire for Anticlimbing
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Painting of ST poles 9 mtr. Long with 2 coat of Al. paint
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for creation of 25 KVA Sub Station at W.No. 03 Pyt. Birnoo under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI M Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Painting of ST poles 9 mtr. Long with 2 coat of Al. paint
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for provision of electric poles in pyt. Barta Block Jaganoo under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles with two coats of Aluminium paint.
Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for installation of electric poles in pyt. Jandrore-B Block Ghordi under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for installation of poles and cables in Pyt. Mani Block Ghordi under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
LT fabricated switch with aluminium busbar.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for installation of electric poles at Moh Upper Incha near Kredu Kankali W.No. 02 Pyt. Incha Block Kulwanta under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
LT fabricated switch with aluminium busbar.
Survey, supply, Transportation, Carriage, Erection, Testing and Commissioning for Erection of 1 Phase 2 Wire LT line on 8 mtr. ST poles, 30 mm sq. ACSR Weasel Conductor for installation of electric poles with accessories Block Ramnagar under PRI Grants.
8 mtr. Long ST Pole (ST-410 SP-15)
GI Mukki Clamps for shackle insulator
30mm² ACSR Weasel Conductor
Shackle insulator
Galvanized Nuts and Bolts.
Jeet Kumar
VEENA CONSTRUCTION CO.
JAI CHANDI MAA ENTERPRISES
M/S D.K TRADERS
SWASTIK ELECTRICAL AND CONSTRUCTION WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .