Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.2 LQualified Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps SEC 03 SOUTH WEST DELHI DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps | L1 | Qualified | |
| 2 | L2₹5.4 L+₹19,260 (3.72%)Qualified Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps 10 NO STOP BHOPAL MADHYA PRADESH 462016 | BHOPAL | MADHYA PRADESH | 462016 | Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps | L2 | Qualified | |
| 3 | L3₹5.5 L+₹36,750 (7.10%)Qualified Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps SHOP NO 782 19 GOBINDPURA MANIMAJRA MANIMAJRA CHANDIGARH 160101 | CHANDIGARH | CHANDIGARH | 160101 | Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps | L3 | Qualified | |
| 4 | L4₹5.5 L+₹36,810 (7.11%)Qualified Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps WARD NO 67 MUTHI MUTHI NEAR MATADOOR STAND MUTHI JAMMU JAMMU KASHMIR 181205 | JAMMU | JAMMU AND KASHMIR | 181205 | Make: PREMIER
Model: Premier | FCBC 24v-48v-25 amps | L4 | Qualified | |
| 5 | Disqualified Make: S V Tel
Model: S v TEL Btry Charger OPP CHAWLA MARBLES GOLDEN TRUST COLONY TIRLOK LEELA SAILI ROAD 978 GURDASPUR PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | Make: S V Tel
Model: S v TEL Btry Charger | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Aug 2018, 9:00 amClosed
battery chargers Battery Chargers ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based
SMPS Based Compatibility with battery type (User Selectable) Tubular Tubular
Lead acid
VRLA-SMF
Tubular & VRLA-SMF
Lead acid & VRLA- SMF
Tubular & Lead acid
Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1
3
5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged yes - 1/4 battery through pulse charging. Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status
Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - 2/4 Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. fcbc24v48v25amps - Test report date 24-04-2018 - Name of Lab Premier Sales Corp. - Address of Lab Janak Puri
New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sudipto Roy 194101
14 CORPS ENGINEERING SIGNAL REGIMENT
NEAR LEHO OFFICE
SKARA
YOKMA
LEH - LADHAK - 194101 30 45
409994
GEM/2018/B/58013
battery chargers
45 days
Ladakh; Leh Ladakh
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| battery chargers Battery Chargers ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values Ungrouped GENERIC Charger technology Transformer Based Transformer Based | - | - | - |
| SMPS Based Compatibility with battery type (User Selectable) Tubular Tubular | - | - | - |
| Lead acid | - | - | - |
| VRLA-SMF | - | - | - |
| Tubular & VRLA-SMF | - | - | - |
| Lead acid & VRLA- SMF | - | - | - |
| Tubular & Lead acid | - | - | - |
| Lead acid & Tubular &VRLA-SMF Number of Independent charging stations (in numbers) 1 1 | - | - | - |
| 3 | - | - | - |
| 5 CONSTRUCTIONAL Input Voltage Range (VAC) 160 volt 270 volt (ISI MARKED POWER CORD TO BE PROVIDED) - AC surge protection AC surge protection at Input side with MOV (Metal Oxide Varistor) - Soft start and Soft stop feature without inrush current Yes - Facility for charging deep discharged yes - 1/4 battery through pulse charging. Not to charge battery in case one or more cells are internally short/Battery voltage less than 10.5V Yes - Digital display of output voltage and current Yes - LED Indication for Charging Status | - | - | - |
| Charged condition status and reverse polarity Yes - Cabinet Material CRCA Sheet - Cabinet Thickness (mm) minimum 1.2 mm - Length of Charging Cable for each station. (metre) Minimum 1.5 mtrs. Length (ISI MARKED Cable) - Size of Charging Cable for each station. (sq. mm) min. 6 sq.mm as per IS:694 ISI MARKED FLEXIBLE Cu cable per station - FUNCTIONAL Battery/battery bank Voltage (Volts) 12 Volts per station - Capacity of the battery to be charged(User Selectable) (AH) 7 aH TO 120 aH - Maximum Charger output current (Amp) 12 Ampere per station - Charging Cut-off Voltage per 12V battery (Volts) 14.5 volt +/-0.2 volt - Efficiency (%) >/= 75% - Ripple (Peak to Peak at Full Load) (millivolts) <100 - Reverse Polarity Protection Yes - Short Circuit Protection Yes - Over Current Protection Yes - Over voltage cutoff protection Over voltage protection at 280 volt at input and automatic recovery at 270 volt when the voltage is reduced from 280 volt - 2/4 Cut-in voltage for charging a discharged battery (Volts) Cut-in voltage shall be 10.5 Volt - Cut-off voltage for charging a discharged battery (Volts) Cut-off voltage shall be 14.5 V +/- 0.2 Volt - Minimum operating temperature (Degree Celsius) -10 - Maximum operating temperature (Degree Celsius) +55 - CERTIFICATIONS Availability of Type Test Report from Central Government NABL/ILAC Accredited lab To prove conformity to the specification Yes - Type Test report No. fcbc24v48v25amps - Test report date 24-04-2018 - Name of Lab Premier Sales Corp. - Address of Lab Janak Puri | - | - | - |
| New Delhi - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sudipto Roy 194101 | - | - | - |
| 14 CORPS ENGINEERING SIGNAL REGIMENT | - | - | - |
| NEAR LEHO OFFICE | - | - | - |
| SKARA | - | - | - |
| YOKMA | - | - | - |
| LEH - LADHAK - 194101 30 45 | - | - | - |
Exempted
4 Aug 2018
31 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_409994.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .