| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.8 LAccepted-AOC 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.7 L+₹2.3 L (5.58%)Rejected-Finance NEAR MES FILTER PLANT SANGOOR UDHAMPUR J K 182101 | UDHAMPUR | UDHAMPUR | J K | 182101 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹42.7 L+₹2.3 L (5.61%)Rejected-Finance B1 DAYA NAGAR SHAMSHABAD ROAD RAJPUR CHUNGI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹43.0 L+₹2.5 L (6.26%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹43.4 L+₹2.9 L (7.25%)Rejected-Finance 6 RAILWAY STATION ROAD ONKAR INDUSTRIES GULAMALI PURA BAHRAICH UTTAR PRADESH 271801 | BAHRAICH | UTTAR PRADESH | 271801 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
4 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITIES
GE UTILITIES UDHAMPUR PO GARHI PIN 182121
Repair/Maintenance of external Electric Supply and connected work at MPH area and Repair, Maint/Replacement to Electric Network system for CPH area under GE Utilities Udhampur
2021_MES_408633_1
GE/U-76/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utilities Udhampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE UTILITIES UDHAMPUR
₹98,000
Yes
19 Mar 2021
1 Jan 2021
6 Feb 2021
1 Jan 2021
4 Feb 2021
21 Jan 2021
75 days
Amount
Takingdown the old U/S change over switches of following capacity in the panel. S&F on load change over switch 4 pole, confirming to IEC 947-3 all as specified & directed. Make:- Havells / L&T/ Schneider
800 Amps, 4 pole
630 Amps, 4 pole
400 Amps, 4 pole
250 Amps, 4 pole
Taking down the U/S ACBs from existing LT panel boards, S&F LT ACB, 4 pole, 415 V, 1000 Amps, 4 pole,50 Hz with magnetic release, manual draw out type, Ico-50 KA with all as specified & directed. Make:- Schneider/ Legrand/ L&T/Havells
Taking down the U/S panel mounted in ACB of 800 amp capacity, S&F LT ACB with sheet metal enclosed pedestal type to house ACB 800 Amps 4pole, manual draw out magnetic release breaker of capacity 50 KA all as specified & directed. Make of ACB:- Schneider/ Legrand/ L&T/Havells
Taking down th U/S change over switches 400Ampere , S&F LT change over switch Onload type 400 Amps, 4 pole, 50 HZ, conforming to IEC 947-3 all as specified & directed. Make:- Legrand/ L&T/Havells
Taking down Unserviceable Gang Operated Air Break switches from existing 2pole/4 pole structure , S&FGang Operated Air Break Switches 3pole, mechanically operated(horizantal/ vertical operation) , mounted on insulator and steel frame with operating mechanisum MS/ GI handle worked from ground level for current ratio of 400 Amps with drop out fuse elements of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles and necessary electrical connections complete all as specified and directed.
S&F lightning arrester expulsion type complete with all fittings transmission class 11 KV, discharge capacity 65KAmps including taking down the U/S lightning arresters complete all as specified and directed.
Painting to poles 11mtrs by scrapping the system with emery paper and applying one coat of red oxide over it. After settling apply 2 coats of synthetic enamel paint ( Silver ) colour over it. Writing the letters over the lower portion of pole the sysetem configuration up to 10 letters as directed by engineer-in-charge. Painting with white wash to the foundation / coping of pole all as specified & directed.
Taking down the unserviceable battery charger from the system supply and fix DC battery charger capacity 100ah , 110V/30 Amp FCBD with DCDB all as specified and directed by engineer in charge . Make:- Amarraja/ Exide/AMCO
Taking down the unserviceable batteries 12volts/180Ah from the system of UPS/ Genset . Supply and fix Batteries 12 volts/ 180ah in UPS/ Genset all as specified & directed . Make:- AMARRAJA/ EXIDE /AMCO
Supply and fixing 120 Watt LED Flood light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 110 lumen/Watt (Minimum lumen output of luminarie should be 13200 Lumens) color rendering (CRI) of > 70 and co-related color temperatue (CCT) of 5700K (+500K), The luminarie should have 5 KV surge protection, PF >0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. Make of LED shall be CREE/NICHIA/OSRAM. The potted driver used must be a constant current constant voltage driver with efficiency of > 85%. The manufactes LOGO must be embossed/Engraved in the housing of the luminarie. Make ; CG Cat No LFLN-120-CDL/60-M or equivalent in Philips/Wipro.
Supply, Installation, testing & Commissioning of LT Panel outdoor,weather proof, cubicle panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory fabricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel. Copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 400 amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos
Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job
Incoming :- MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 250 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 No
Outgoing :- MCCB 4 pole ,Ics=100%Icu- 16 KA, 415 Volts, 125 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -03 Nos. Note :- (i) Rates quoted by the contractor shall be deemed to include for connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (ii) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge.
Supply and fixing 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/watt (Minimum- lumen output of luminarie should be 6000 Lumens) color rendering (CRI) of >75 and co-related color temperature (CCT) of 5700K (+500K). The luminariea should have 5 KV surge protection, PF >0.95, and total harmonic distortion of THD< 10% voltage range of 140-280V should be provided. Make of LED shall be CREE/NICHIA/OSRAM. The potted driver used must be a constant current constant voltage driver with efficiency of > 85%. The manufactures LOGO must be embossed/engraved in the housing of the luminarie. Make:- CG Cat No LSTP-60-CDL-M or equivalent in Philips/Wipro.
Taking down the unserviceable garden lights from the existing system, supply and fix LED bollard lights of 10 watt capacity, IP-65 rated inverted peyramid tripod type with soft 360 degree light distribution complete all as specified and directed by engineer-in-charge Note : Necessary fixing arrangements like grouting, finishing any requirement for pipe for holding the bollard is deemed to be included in quoted rate by the contractor. Make:- CG Cat No LBLSN-10-CDL/ Philips/Wipro
Taking down the unserviceable cross arms / supports Supply and fix Cross arms, bracings, supports clamps and back plate fabricated from structural steel sections including nuts, bolts washers, welding , bending cold/ hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat all as specified and directed.
Taking down the unserviceable aluminium conductor from overhead lines , Supply and fix alumiunium conductor (Otter) configuration for interconnecxtions of jumpers with GODs all as specified and directed by engineer-in-charge
Taking down the unserviceable rubber mats from the substations supply and fix Synthetic Insulating rubber mats of size 2m x 1m x 19mm all as specified and directed Make:- Electromat/Jyothi/Oblum
Dismantling of unserviceable steel tubular swaged pole/ PCC pole complete with accessories all as directed by Engieer-in-Charge.
Dismantling of unserviceable ACSR Conductor of any size from existing over head lines completed all as specified and directed.
Supply and Fixing Steel tubular swaged pole erected to truly vertical or planted as strut complete with 6 mm thick MS Base plate,welded to pole,finial taper cap, bolts, nuts, screws,11 Mtr long, type 410 SP - 55,including drilling of holes of required size for fixing of cross arms,painting the exposed surfaces of pole with two coats of aluminium paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the portion embedded in concrete, and marking pole no. with black paint at suitable height all as specified and directed by Engineer-in-Charge.Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’
M&L for ACSR conductor of required size for over haed lines on poles including streching,tighting of poles insulator with binding wire of sutable size with insulator/streching of ACSR conductor all as specified and diected by Engr in charge.
Material and labour in replacement of PVC insulated multi stranded aluminum conductor PVC cable sheathed 6 Sqmm twin core and making connections of street light fittings with overhead lines/UG Cable complete all as specified and directed.
M & L for providing earthing with GI earth plate electrode 600 X 600 X 6mm buried directly in ground (earth pit not less than 2.25M deep below ground level ) with top edge of the earth plate not less than 1.5M below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts,bolt,washers etc connected to earth test point complete all as specified in electrical plate NO 3 of SSR1996 part 1 ,including necessary excavation and earth work in any strata of soil,comman salt, charcoal dust, 40 mm dia light grade GI pipe for protection to earth lead, GI water pipe 20mm dia with funnel &wire mesh , PCC pit with CI cover and frame etc all as specified and directed by Engineer-in-charge. Note:- (i) All the joints shall be made with welding to get proper conductivity. (ii) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge
Supply and fix in replacement MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 315 Amps , with adjustable thermal and fixed magnetic setting with extended terminals complete all as directed.
Supply, laying, commissioning and testing in replacement of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 150 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying, commissioning and testing in replacement of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy Duty) with aluminium conductor 11000 volts grade cross sectional area 95 sq mm, 3 core including taking down of U/S Cable complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exceeding 1.50 m wide and not exceeding 1.50 mtr in depth and getting out for pipe, cable pole, stay etc, all as specified and directed by engineer-in-Charge.
All as per Srl item No. 26 here in before but depth exc.1.5m but not exc. 3m complete all as specified & directed by Engineer-in-charge.
Returning filling in ( soil ) including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick, all as specified.
Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified.
M&L for Dry sand cushioning to underground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable complete all as specified. Note : Punned thickness shall be measured.
Supply and laying un reinforced pre cast concrete cable cover class HV type 2 Flat size 300X180X40mm all as specified and directed.
M&L for providing new sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete, all as specified and directed.
M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete, all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 150 sqmm complete, all as specified and directed by Engineer-in-Charge.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete, all as specified and directed by Engineer-in-Charge.
S&F tubing of 50 mm bore 'light grade' galvanised iron with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
S&F tubing 'light grade' galvanised iron of 100 mm bore with all fittings and fixed to poles, walls etc. with flat iron clamps/bolts/nuts/washers or laid in floors/under roads complete all as specified and directed.
Disconnection/taking out existing UNSV/damaged LT under ground cable/service cable from trenches/ducts or from to poles/walls or under roads/paths/drains/culverts and depositing the same in the storeyard or disposed off complete all as specified and directed of following sizes :-
10 Sqmm 2 core
16 Sqmm 2 Core
16 Sqmm 4 Core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
70 Sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
Supply and Laying and fixing in replacement of along the poles or passing through pipes or laid under floor of through walls etc jointing and testing LT Cross Linked Polythene Insulated(XLPE insulated) galvanized steel strip armoured electric cable 1100 volt grade heavy duty ISI marked with aluminium conductor and overall served with an outer sheath of PVC, of cross sectional area as under:- (Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately)
10 Sqmm 2 core
16 Sqmm 2 Core
16 Sqmm 4 Core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
70 Sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
Dismantling re-errecting,restringing tensioning and repair to overhead line ACSR conductor any size as required on poles LT / HT including fixing insulators and jointing with ACSR conductor complete all as specified and directed.
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the HT/LT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the HT/LT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge.
Taking out the existing unserviceable rusted LT panel board alongwith busbar, MCCBs etc of any size/capacity including disconnection, breaking PCC foundation etc.and disposed off as specified and directed by Engr-in-Charge.
Supply, Installation, testing & Commissioning in replacement of LT Panel outdoor,weather proof, cubicle panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory fabricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 500 amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos
Painting to poles 11mtrs by scrapping the system with emery paper and applying one coat of red oxide over it. After settling apply 2 coats of synthetic enamel paint ( Silver ) colour over it. Writing the letters over the lower portion of pole the sysetem.
Incoming :- MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 300 /320 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos
Outgoing :- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 100 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos Note :- (i) Rates quoted by the contractor shall be deemed to include for connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (ii) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge.
Supply, Installation, testing & Commissioning in replacement of LT Panel outdoor,weather proof, cubicle panel board made out of 3.15 mm thick MS/CRCA steel sheet mounted on 60 cm long legs made out of 40 x 40 x 6 mm equal angle,embedded in PCC 1:2:4 type B-1 bocks of size 15x15x20 cm , front and back openable,double door openable up to minimum 150 deg. & removable type having magnetic catche system, lockable / openable by keys from both sides having chromium plated locks, louvers and air vent gaskets for natural air flow suitable for 3 phase 4 wire 415 volts 50 Hz ,factory fabricated with suitable foamed-in PU gasket to make it dust/vermin proof , IP 54 protection, Powder coated and prewired as per standard engineering practice, the panel manufacturer should have got any one of the panel tested at CPRI earliest for short circuit current of 50 KA for one second and similar design and technology shall be adopted for fabrication of panel copy of CPRI test report shall be produce to GE along with a certificate from manufacturer of the panel that the similar design and standard have followed in these panels.complete ,suitable cable glands for cable entry. The panel shall be suitable to accomodate the following equiptments :-
Aluminium bus bar of capacity duly covered with colour coded shrinkable sleeves not less than 800 amps for phases and neutral - 01 set
Panel indicating lamp neon/LED type (Red ,Yellow & Blue) with lamp holders - 03 Nos
Panel instrumental wiring with FRLS suitable size but not less than 2.5 sqmm copper wire single core - 01 Job
Incoming :- MCCB 4 pole , Ics=100%Icu- 35/36 KA, 415 Volts, 400 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -01 Nos
Outgoing :- (a) MCCB 4 pole ,Ics=100%Icu- 25/26 KA, 415 Volts, 200 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos. (b) MCCB 4 pole , Ics=100%Icu-25/26 KA, 415 Volts, 160 Amps , with thermal adjustable and fixed magnetic setting with extended terminals -02 Nos Note :-(i) Rates quoted by the contractor shall be deemed to include for connection of incoming & outgoing cables using suitable size of aluminum lugs, nuts and bolts. (ii) Necessary PCC and earth work required as per the existing panel for the grouting of panel legs all as directed by Engineer-in-Charge.
Dismantling/Taking down of unserviceable/damaged Air break switch of any cap.& removing from site of works all as specified and directed.
Supply, installation and testing in replacement of HT gang operated air break switch 11 KV, 3 pole vertically mounted type, mechanically operated, mounted on steel frame with operating mechanism, worked from ground level for current upto 200 Amps with drop out fuse elements of required capacity, GOD/switch having 100 MVA rating at 11 KV and 12 insulators suitable for 11 KV, 50 C/s including mounting on HT poles and necessary electrical connections complete all as specified and directed.
S&F in replacement of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’.
M&L for road cutting for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified by Engr-in-Charge.
M&L for Surface cleaning by removing the roots completely from the earth, shrubs, vegetation, grass, bushes, weeds by excavation not exceeding 30cm and averaging 15cm deep including sweeping removing the same to distance not exceeding 50m away from the installation and burning the same all as specified and directed by Engr-in-Charge.
Supply and fixing LT Line spacers rigid type 5 wire Make:- Pactil/Atlas/Raychem (RPG)/Jaipuria
M&L for welding of broken feeder piller doors,indoor/out door using butt hinges appropriate size and making proper locking arrangements of doors , complete all as directed and specified.
M& L for preparation of old painted surface of feeder piller boxes indoor /outdoor and applaying two coat of synthetic enamal paint.complete all as directed and specified.
M&L for replacement of old unserviceable cable with PVC insulated 2.5 sqmm, three core multi stranded flexible, copper conductor cable complete all as specified and directed by Engr-in-charge.
M&L for replacement of PVC jumper wire cable of size 70 sqmm aluminum conductor single core suitable for HT cable 11000 volts complete all as specified and directed by Engr-in-charge.
M&L for replacement of PVC jumper wire cable of size 50 sqmm aluminum conductor single core suitable for HT cable 11000 volts complete all as specified and directed by Engr-in-charge.
FANGALIA TRADERS
MAHAJAN TRADING CO
proach associates
MOHAN LAL AND SONS
pargal builders
VAISHNO TRDAERS
slathia construction works
M/S Builders Indias
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .