Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Admitted | |
| 2 | L2₹17.4 L+₹1.1 L (6.92%)Rejected-AOC | L2 | Rejected-AOC Admitted | |
| 3 | L3₹18.1 L+₹1.8 L (10.8%)Rejected-AOC | L3 | Rejected-AOC Admitted | |
| 4 | Rejected-Technical | - | Rejected-Technical Not in Category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not in Category |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
19 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) Campbell Bay
Garrison Engineer (I), Military Engineer Services, Army Land, Great Nicobar Islands, Campbell Bay, Pin 744 302
MANNING AND OPERATION AND COMPREHENSIVE MAINTENANCE OF ELECTRIC SUPPLY INSTALLATION AND ALLIED WORKS AT INS BAAZ 3U DET AND COTS RADAR CAMPBELL BAY UNDER GE(I) CAMPBELL BAY
2020_MES_380250_4
8712/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (I) Campbell Bay
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (I) Campbell Bay
₹36,000
Yes
29 Dec 2020
3 Dec 2020
21 Dec 2020
4 Dec 2020
19 Dec 2020
4 Dec 2020
60 days
Amount
Providing Services for Manning, Running & daily operation of Main Receiving station (HT/LT) located at INS Baaz Sub Station by deploying One Electrician Skilled in each shift round the clock in three shift per day (8 Hours per shift), including Sundays & holidays, Maintaining the Log sheet/ Register for Incoming & out Going feeders as directed & shown by Engr-In-charge and also attending break downs/ repairs on break down complaint calls of HT & LT lines in the area and rectifying the problems by replacing DO fuses and HT jumpers etc and restore the electric supply in area with necessary arrangements, if required for change over of HT ring main supply etc consisting of following and all as specified and directed . (a) SHIFT DUTIES (TIMINGS) (i) I Shift : 0600 Hours to 1400 Hours (ii) II Shift : 1400 Hours to 2200 Hours (iii) III Shift : 2200 Hours to 0600 Hours (Note :– 01 Operator per shift total three shifts – 03 Operators (Electrician) Details of Plant :- (a) Main supply at 11 KV - 01 Nos Receiving Points from AED (b) Step Down Transformer 11/0.433 KV-01 Nos : 01 No 200 KVA Near P-59 Bld 01 No 63 KVA Near DSC Line (c) Incomer through Two Pole Structure 11 KV 200 Amps - 02 No (d) Incomer through Four Pole Structure 11 KV 200 Amps - 01 No (e) Out going feeders - 02 Nos (f) DG Set - 03 Nos : 01 No at Sub - Station - 125 KVA
Providing Services for Manning, Running & daily operation of Main Receiving station (HT/LT) located at 3U DETACHMENT Sub Station by deploying One Electrician Skilled in each shift round the clock in three shift per day (8 Hours per shift), including Sundays & holidays, Maintaining the Log sheet/ Register for Incoming & out Going feeders as directed & shown by Engr-In-charge and also attending break downs/ repairs on break down complaint calls of HT & LT lines in the area and rectifying the problems by replacing DO fuses and HT jumpers etc and restore the electric supply in area with necessary arrangements, if required for change over of HT ring main supply etc consisting of following and all as specified and directed . (a) SHIFT DUTIES (TIMINGS) (i) I Shift : 0600 Hours to 1400 Hours (ii) II Shift : 1400 Hours to 2200 Hours (iii) III Shift : 2200 Hours to 0600 Hours (Note :– 01 Operator per shift total three shifts – 03 Operators (Electrician) Details of Plant :- (a) Main supply at 11 KV - 02 Nos Receiving Points from AED (b) Step Down Transformer 11/0.433 KV -02 Nos : 01 315 KVA Near Sub Stn 01 160 KVA Near ORR (c) Incomer through Two Pole Structure 11 KV 200 amps - 02 No (d) Out going feeders -02 Nos (e) DG Set - 03 Nos : 01 No at Sub-station - 320 KVA 01 No Near Admin Bldg - 50 KVA 01 No at Cots Radar - 15 KVA
Taking out Transformer from its Position for repair /servicing/ rewinding of capacity upto 320 KVA , 11/0.433 Volts installed on Two Pole structure / RCC Plinth structure, by disconnecting /opening HV, LV Electrical connections, earthing connections along with following other works and all as specified and directed .
M&L for rewinding HT coil of 33/ 11 KV , 11/ 0433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Re-insulation of HT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and HT insulation material suitable for HT 11 KV transformer complete all as specified and directed. Note :- Item shall be measured only where re-insulation of copper wire is required
M&L for rewinding LT coil of 33/ 11 KV , 11/ 0433 KV Transformer any capacity using proper size DPC copper wire and insulation material , heating coils in heat chamber after rewinding including taking out carefully burnt unserviceable copper winding of coils complete all as specified and directed.
Re-insulation of LT coil of transformer of any capacity using proper size paper insulation material to form DPC Copper wire and insulation material suitable for HT 11 KV transformer complete all as specified and directed. Note :- Item shall be measured only where re-insulation of copper wire is required
Repair /servicing to transformer at site of capacity 100 KVA to 320 KVA installed on Plinth / Pole mounted structure by opening top cover & replacing unserviceable spares / components of transformer ,without lifting core assembly reassembling after repair & testing complete all as specified and directed by Engr-in-Charge. Note :- (a) Dehyderation and filteration of transformer oil, and replacement of unserviceable spares shall be measured and paid seperately under appropriate Item of schedule however cost of renewal of Nut, bolts & washers shall deemed to be included in unit rate quoted
Supply only Ceramic Bush insulators on LT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only brass spindle on LT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only Ceramic Bush insulators on HT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only brass spindle on HT side as per existing size, shape and specification for capacity upto 320 KVA, 11/0.433 Volts transformers
Supply only breather assembly as per existing size, shape and specification complete for capacity upto 320 KVA, 11/0.433 Volts transformers
Dehydration and filtration of existing transformer oil of transformers capacity ranging from upto 200 KVA (11 KV System step down to 11/0.433 KV) on site at different locations without disturbing the power supply system with filtration machine and heating system in order to achieve Di-electric strength of oil 40 KV minimum at 2.5 mm gap complete all as specified and as directed.
Supply only Temperature Guage as per existing size, shape and specification complete for capacity 200 to 300 KVA, 11/0.433 Volts transformers
Supply & filling up of transformer oil conforming to IS -335 of 1993 as in topping up / replacement up to desired level of transformer oil capacity complete all as specified and as directed. [Note: Dielectric strength of oil should not be less than 42 KV/cm complete all as specified and directed.] (Make : GULF/POWER OIL or equivalent as approved by GE)
M/S Sudhir Kumar Gupta
M/S G S GREWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .