Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹30 L
EMD Value
₹30,000
Closing Date
26 Oct 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Block Development Officer, Mudukulathur Block
Block Development Office, Mudukulathur Block
Construction of Health Sub center at Pooseri Village in Pooseri Panchayat
2022_RDTN_257039_1
A2/2840/2022 Pooseri HSC 2call
Open Tender
Civil Works - Buildings
Item Rate
Mudhukulathur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹30,000
26 Oct 2022
17 Oct 2022
26 Oct 2022
17 Oct 2022
26 Oct 2022
17 Oct 2022
Amount
CONSTRUCTION OF HEALTH SUB CENTRE AT POOSERI VILLAGE IN POOSERI PANCHAYAT
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Refilling the basement with excavated earth other than sand complying the standard specification
Cement Concrete 1:4:8 (One Cement, Four sand and Eight hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification
Brick work in Cement Mortar 1:5 using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
Upto Basement
Above Basement to G.F
Brick partition walls in Cement Mortar 1:3 using best quality of country bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.20 m height for plane surface in all floors with all cross bracing using mild steel of size 0.95 cm x 60 cm and 10 guage stilfaned welded with mild steel angles of size 25 mm x 25 mm x 3 mm for boarding laid over silver oak (c-word) joint of size 10 cm x 6.50 cm dia spaced about cnter to center and supported by casuarinas propels of 10 cm to 13 cm dia spaced at 75 cm center to center etc., complete complying with standard specification and as directed for the following items
Below Basement
ground level to basement
Reinforced Cement Concrete 1:11/2:3(One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) etc., complete complying with standard specification and as directed by the departmental officers
Below Basement
basement To ground floor
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification. (Contractor has to make his own arrangements for the supply of steel and binding wire)
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the departmental officers.
Finishing with one course of pressed tiles of size 23x23x2cm with cm 1:3 pointed with same mortar
Flooring with Vitrified tiles size 600x600x8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.
Providing, fabricating and fixing M.S. grills Windows, and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer.
Paving the flooring with special type of flooring tiles (Cement based Hydraulically pressed Anti skid tiles (20mm thick) in CM 1:3, 20mm thick
Dadooing walls with best approved quality, colour glazed tiles of 150mm x 150mm x 6mm size set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers.
Manufacturing,supplying and fixing of stainless steel hand rails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete.
Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of Paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel
Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50mm x 30mm.The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
UPVC Window supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSM and 100% corrosion free, the profiles are multi chambered section with wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plain glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss.
UPVC VENTILATOR: Supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSM and 100% corrosion free , the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black color) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all around the frame. The ventilator should be got approved from the Executive Engineer before use on work.
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
K.MUNIYASAMY
stage.html
html • 0.02 MB
finance_303994.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .