Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC VILL ASARPUR JOGIPUR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹16.6 L+₹1.6 L (10.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹28,800
Closing Date
23 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalgarh Jattan
GE Lalgarh Jattan
PROVN OF STN CDRS OFFICE WITH BATHROOM AT LGJ MIL STN
2020_MES_370845_4
8931-19/20-21
Open Tender
Civil Works
Lump-sum
180 days
GE Lalgarh Jattan
Class E Cat (a)(i)(b)(i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹28,800
Yes
19 Mar 2021
27 Jan 2021
26 Feb 2021
27 Jan 2021
23 Feb 2021
10 Feb 2021
60 days
Amount
Lump sum price worked out by the contractor for "BUILDING AND STRUCTURES" as listed in Schedule `A' Part-I*Above/below the lump sum price inserted by the MES in Schedule `A' Part-I
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-II*Above/below the lump sum price inserted by the MES in Schedule `A' Part-II
Lump sum price worked out by the Contractor for "INTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-III **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-III
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule `A' Part-IV*Above/below the lump sum price inserted by the MES in Schedule `A' Part-IV
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule `A' Part-V*Above/below the lump sum price inserted by the MES in Schedule `A' Part-V
Lump sum price worked out by the Contractor for "ROAD/PATH/CULVERT" as listed in Schedule ‘A’ Part-VI **Above / below the lump sum price inserted by the MES in Schedule ‘A’ Part-VI
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule `A' Part-VII *Above/below the lump sum price inserted by the MES in Schedule `A' Part-VII
Lump sum price worked out by the contractor for "EXCAVATION/EARTH WORK/SITE CLEARANCE" as listed in Schedule `A' Part-VIII *Above/below the lump sum price inserted by the MES in Schedule `A' Part-VIII.
Lump sum price worked out by the contractor for "HOT WATER APPARATUS" as listed in Schedule `A' Part-IX *Above/below the lump sum price inserted by the MES in Schedule `A' Part-IX
Lump sum price worked out by the Contractor for Schedule `A' Part-X (rate against Srl No.10.01 to 10.10 shall be quoted by the Contractor)
Internal Electrification Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6.3 mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5m below ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of MES schedule Part-I and testing on completion, including necessary excavation and earth work medium grade 20mm /15mm dia respectively. GI pipe for watering and protection etc but without PCC earth pit/cover etc and all as specified and directed by Engr-in Charge.
Supply and fix distribution box 3 phase TPN 8 ways made of aluminium alloy (LM6) for MCCB in commer with bus bar rating 200 Amps vertical type dust and vermin proof comprising of the following :- (a) MCCB, 125 Amps 415 volts thermal magnetic release Incoming 25 KA - 1 No, (b) MCB, SP&N / DP 40 Amps outgoing - 10 Nos, (c) MCB SP outgoing 10 Amp - 06 Nos
S&F in DBs (catered above) old MCBs 9 KA confirm to IS-8828 : 1996, IEC- 898 : 1995 rupturing capacity and rating for TP & N 63 Amp complete all as specified and directed by Engr-in-charge. Make :- Legrand/ ABB/ Seimens
S&F in DBs (catered above) old MCBs 9 KA confirm to IS-8828 : 1996, IEC- 898 : 1995 rupturing capacity and rating for SP 6-32 Amp complete all as specified and directed by Engr-in-charge. Make :- Legrand/ ABB/ Seimens
S&F recessed mounted square LED down lighter 36 watt with aluminium frame LED panel high quality diffuser fo uniform light and high efficiency of size 2x2 luminaire with driver complete all as specified and as directed. Make Bajaj Cat Pt No BZRSQL 36 W GZi WH or equivallent in Crompton/ Havells.
S & F LED light fitting 1 x 18 W, 230 V integral sleek polycarbonate LED Channel with white acrylic cover incl making connection complete of Make: Bajaj cat Pt No BCLSB18 or equivalent model of Crompton Greaves.
Supply and fix lamp holder insulated body with back plate for angle/batten fitting with LED of 09 watt complete all as specified and as directed.
S & F LED building security light fitting 25 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI medium grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one complete all as specified and directed by Engr-in-charge. Make of fitting Bajaj Cat Pt No BRLEP 25 W LED or equivallent in Crompton/Havells.
M&L for fixing ceiling fan 1200 mm sweep single phase 50 Hz with down road complete with canopy fan blades etc. incl making connection with three core PVC copper wire complete all as specified and directed by Engr-in-charge. Make : Bajaj Model -Ultima 1200mm white CF or equivalent model of Khaitan /Usha/Orient. .
M&L for fixing fresh air fan 225 mm sweep single phase 50 Hz complete with louver etc. incl cutting hole in wall and making connection with three core PVC copper wire complete all as specified and directed by Engr-in-charge. Make : Bajaj Model-Bajaj freshee 225mm or equivalent model of Khaitan/Usha/Orient.
External Water Supply M&L for cutting existing DI/GI pipe and fixing ferrule for providing water connection complete all as specified and as directed.
Sewage Disposal Supply and laying DWCPE (SN8) 180 (OD)/163 (ID) mm diameter drain pipes as per IS-16098 (Part-II), laid in trenches on moorum bed to required slope, including all accessories/fittings, jointing and tested complete all as specified and as directed by Engineer-in-Charge
Hot Water apparatus Supply & fixing Water heater (Geyser) vertical type, BEE star rating five(5) steel ineer tank glass line coating, ABS thermoplastic outer body and with temperature dial, safety pressure valve rating, AC 230 volts of capacity 25 Ltrs, ISI marked fixing with 12 mm dia 15cm long bolt & nuts etc and grouted in CM (1:3) including cutting/drilling holes in the wall and making good the disturbed surface as per existing treatment complete all as specified & directed by Engr-in-charge. Make: Bajaj Shakti 25L GPV (Code No 150747) or similar specification in CG/Havells/Usha/Recold
S&F cast copper alloy chromium plated connection for hot water 15mm size of length 450mm with nuts all as specified and directed by Engineer-in -Charge
Aggarwal brothers and company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .