Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC HOUSE NO 87 SHAH FAISAL ABAD DHOBI MOHALLA BATAMALOO SRINAGAR 190009 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190009 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.9 L+₹1.4 L (15.0%)Rejected-Finance | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹11.0 L+₹1.5 L (16.2%)Rejected-Finance | L3 | Rejected-Finance BEING OTHER THAN LOWEST |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
25 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs c/o 56 APO PIN-914134
REPAIR / MAIINT OF 11 KV HT ELECT INSTALLATIONS INCL CONNECTED ITEMS SUCH AS TRANSFORMERS, HT SERVO VOLTAGE STABILIZER, VCBS, CT/PT, GOD, DO FUSES, CONTROL CABLES ETC AT SONAMARG UNDER GE 970 EWS
2021_MES_497894_1
134 WE-57(T)/2021-22
Open Tender
Civil Works
Item Rate
180 days
Srinagar
Please see tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹20,000
Yes
27 Feb 2022
28 Dec 2021
27 Jan 2022
28 Dec 2021
25 Jan 2022
12 Jan 2022
60 days
Amount
Dismantling of existing old unserviceable ACSR conductor of any size and any description and S&F new ACSR conductor all as specified and directed incl stringing through existing RCC/ steel poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes, complete all as specified and directed.
S&F in repairs mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of synthetic enamel paint over one coat of red oxide zinc chrome primer after prepration the surface, complete all as specified and directed.
M&L for replacement stay assembly complete with 20mm dia stay rod with accessories shown in electric plate No 01 incl stay clamps and galvanised stay wire of size 7/4 mm, complete all as specified and directed. Note : Loop insulator, stay wire, excavation and concrete work shall be measured and paid seperately under respective items of BOQ.
S&F in replacement disc type insulator, porcelain vitreous, brown or white, suitable for 11 KV HT working pressure of size 145mm height x 255mm dia including one galvanised mild steel spindle, two galvanised iron washer and one GI nut, complete all as specified and directed.
S&F in replacement pin type porcelain vitreous, brown of white insulator, suitable for 11 KV HT of working pressure of size 150mm height x150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut, complete all as specified and directed.
M&L for painting of HT/LT panel of any description and size with one coat of synthetic enamel paint of standard colour code by using spray gun over the existing painted surfaces after preparing the old painted surfaces, complete all as specified and directed.
Restringing only existing HT 11/33 KV or LT OH line/ Jumpers including dismantling of existing old binding wire for tightening, complete all as specified and directed. Note :- (a) Restringing of each wire/span shall be measured as in RM. (b) Binding wire shall be measured and paid separately under respective item of BOQ.
S&F in replacement incl testing and commissioning of (GOD) gang operated type air break isolating switch horizontal / vertical type mounting complete, double break and operation rod of suitable length 400 Amps capacity and suitable for 11 KV HT supply, complete all as specified and directed.
S&F in replacement lightning arrestor, metal oxide type complete with all fittings, transmission class, discharge capacity of 65 Kilo Amps, suitable for 11 KV, complete all as specified and directed.
Removing of vegitation, grass, scrubs and bushes growing in sub station yard along with fencing by manually/mechanically and keep the sub station yard neat and clean, complete all as specified and directed. Note :- (a) Unit rates quoted deemed to be included to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. (b) Neccesary tools shall be arrange by the contractor without any extra cost to Govt.
M&L for cutting and trimming of tree branches of girth 25mm to 75mm to 3mtr all around of any size, which is obstructing illumination of street light and touching LT/ HT over head line, by using required tools and plants including removing trimmed tree branches, complete all as specified and directed by Engineer-in-Charge. Note :- Each cleaning will be measured and paid.
S&F in replacement of synthetic insulating rubber mat, ISI Marked of size 1mtr x 2mtr x 2.5mm thick, suitable for 11 KV at 11 KV MRS Sonamarg.
Taking down carefully existing 11KV / 433KV Volts distribution transformer of capacity 25 KVA to 250 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations (as directed by Engineer-in-Charge) using suitable capacity of crane or by any other mechanical method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer, transportation to site and unloading including placing at given/existing position and re-commissioning the same, complete all as specified and directed. Note :- All required T&P for disonnection, connection, loading and loading including necessary petty items such as bolts, nuts etc. will be arranged by the contractor and rates for the same shall be deemed included in the quoted rates.
M&L for repair toTransformer step down 11KV / 0.433 KV of any type, of capacity 25 KVA to 250 KVA, after dismantling the transformer body carefully, opening the top cover of transformer for inspection/repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of unsv rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, painting of complete transformer body from outside and inside by weather proof type using spray gun, marking of MES/SM Number etc, replacement of conservator tank glass, reinstalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc., meggering the LT and HT side of the transformer and testing, complete all as specified and directed. Note :- Winding wire for making of coils and LT/HT bushes will be measured & paid seperately under respective item of BOQ.
Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/ losses due to dehydration in distribution transformer 25 to 250 KVA or for replacement complete including draining of old unservicable transformer oil, complete all as specified and directed. Make :- Power Oil/ Castrol/ Pure Lubes
M&L for conducting oil filtration by stream line / vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer including routine testing after filtration for any capacity of transformers/AVR/CT/PT units, complete all as specified and directed. Note :- The contractor shall be change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engineer-in-Charge.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings, suitable for HT side of the transformer of any make and capacity from 25KVA to 250 KVA, complete all as specified and directed.
All as per Ser item No 17.00 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 25 KVA to 250 KVA transformer, complete all as specified and directed.
M&L for painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc, paint free after painting including writing the MES/SM Number with white enamelled paint, complete all as directed for capacity of transformer 25 KVA to 250 KVA (Indoor/outdoor type), complete all as specified and directed.
M&L for earthing complete with GI earth plate of size 60cmx60cmx6mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to GI strip of size 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc. and connected to earthing test point, complete all as specified, directed and testing after completion.
M&L for earthing complete with copper earth plate of size 60cmx60cmx3.15mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to copper strip of size 20x3mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc. and connected to earthing test point, complete all as specified, directed and testing after completion.
S&F in replacement off load tap changer for distribution transformer of any make and capacity from 25-250 KVA, complete all as specified and directed.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the transformer of any capacity/ any make, complete all as specified and directed.
S&F in replacement of brass terminal rod with nuts, bolts washers & bushings suitable for 11KV side of the transformer of any make and capacity, complete all as specified and directed.
S&F in replacement of temperature gauge, suitable size for transformer of any capacity, complete all as specified and directed. Make :- AE or technocommercially equivalent as approved by GE.
Supply, laying, testing and commissioning XLPE cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), of size 3 core 95 sqmm, laid in trenches/ floor/ duct/ fixed on poles through GI tubing, complete all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc. and getting out in hard / dense soil, complete all as specified and directed.
Excavating in trenches not exceeding 1.5 meter wide and exceeding 1.5 meter but not exceeding 3.0 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil, complete all as specified and directed.
Returning, filling in excavated earth work including spreading, levelling, watering and well ramming in layers not exc 25cm thick in any strata, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr, depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
Supplying and laying reinforced precast concrete cable cover, class HV, type-1, flat, size 300mm x 180mm x 40mm, Complete all as specified and directed
M&L for PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) as in foundation, mass concrete, cutting of road etc including necessary form work, complete all as specified and directed.
M/S ZAHOOR ENTERPRISES
CHINAR CONSTRUCTION TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .