Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.7 LAccepted-AOC 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.9 L+₹15,597.50 (2.72%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹6.5 L+₹73,297.25 (12.8%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹6.5 L+₹74,291.75 (12.9%)Rejected-Finance LUCKNOW | LUCKNOW | UTTAR PRADESH | 226001 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹6.9 L+₹1.1 L (19.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹9.7 L
EMD Value
₹19,400
Closing Date
2 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Memaura
AGE (I) AF Memaura
PROVISION OF CERTAIN BR AND EM WORKS AT IACCS OPS ROOM BLDG NO 229 AT AF STN MEMAURA
2023_MES_621125_1
8320/E8
Open Tender
Civil Works
Works
183 days
AGE (I) AF Memaura
As per NIT
8 documents required · 8 mandatory
₹500
AGE (I) AF Memaura
₹19,400
29 Nov 2023
29 Sept 2023
4 Nov 2023
30 Sept 2023
2 Nov 2023
19 Oct 2023
Amount
Providing & fixing semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles at all heights of 595 x 595 mm of approved texture, design and battens having moisture content less than 2%, humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (Part 4)-1970 and light reflectance of 85% (minium) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanishing @ 80 grams per sqm) i.e 50mm long, 8mm outer dia M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2 mm, Galvanished iron perimeter wall angle of size 24 x 24 x 0.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40mm long dry wall wood screws. (Make : PR Ceiling Products Ltd/Visaka Industries Ltd/Diamond International Index Pvt Ltd (Brand : Diamond Ceilings). Note The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing
M&L for solid PVC wall lining consisting of 5mm thick in approved colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises complete all as specified and directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed
M & L for hardcore of broken bricks of gauge n exc 63 mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 40mm thick cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) finishing surfaces of concrete in sub floors, sub bases, etc, even and rough to receive topping layer/screed bed/cement plaster complete all as specified and directed
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and mirror polishing over including 20mm screed bed in CM 1:6 complete all as specified and directed.
M&L for 20mm thick Granite (of any type) tiles machine cut, in skirting/dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and mirror polishing complete over and including 10mm plaster in cement mortar 1:4 complete all as specified and directed.
M&L for preparation of old painted surfaces and applying two coats of plastic emulsion paint over a coat of priming paints over a coat of putty complete all as specified and directed.
S & F powder coated aluminium (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators, partitions with one or more rebates including joining cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing 5.5mm thick sheet glass ordinary quality, tinted with invisible film, exceeding 0.50 Sq m in each pane fixed to aluminium frame work with necessary glazing clips/rubber, packing/gasket, screws, T-brush etc complete all as specified and as directed by Engineer-in-Charge.
M&L for 12mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to aluminium frame work etc complete all as specified and directed.
S & F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and above.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm etc complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) foundation fillings and mass concrete and making good finish complete all as specified and directed.
S&F steel works in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
S&F mild steel work as in bands, straps, hold fast, wall ties, hooks for hanging fans, angle cleats & similar small articles conforming to Fe 410 or Fe 310 complete all as specified and directed
M&L for preparation of new or previously un-treated steel and iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
S&F Pre-painted Trapezoidal profile galvalume aluminium zinc coating GI based corrugaed steel sheet 0.50mm thick (base metal thickness) of any colour having tensile strength of 550 Mpa minimum yield strength conforming to IS - 513 (1994) coated with hot dip alloy of 55% aluminium + 43.50%Zinc +1.50% silicon and finished with resin coat ( of thickness not less than 35 micron) on both surface @150gm/sqm of coating (total both surfaces) of approved colour as in roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap where ever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided where ever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by Engr-in-Charge. (ii) Sheeting shall be fixed of at any height.
S&F Pre-painted Trapezoidal profile galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick (base metal thickness) of any colour having tensile strength of 550 Mpa minimum yield strength conforming to IS - 513 (1994) coated with hot dip alloy of 55% aluminium + 43.50%Zinc +1.50% silicon and finished with resin coat ( of thickness not less than 35 micron) on both surface @150gm/sqm of coating (total both surfaces) of approved colour as in ridge/roof covering/cladding, fixed with self tapping screws (make hilty/fissers), neoprene and epdm washers class 3 of AS-3566(5.5-14X5 for crest and 5.5-14X25 for valley fixed) with 150mm end lap and one corrogation side lap where ever required penetrations and lap in sheet shall be sealed by using proper sealant profile/HDPE fillers shall be provided where ever required to close voids between sheets and fastners etc. as in roof covering/ cladding in straight or curved surface in any height complete all as specified and directed. Note : (i) The colour of sheet for bldg shall be approved by Engr-in-Charge. (ii) Sheeting shall be fixed of at any height.
Surface excavation n exc. 30cm deep and averaging 15cm deep and getting soft soil complete all as specified and directed.
M&L for 75mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) finishing surfaces of concrete in sub-floors, sub-bases etc even and rough to receive the topping layer/screed bed/plaster etc complete all as specified and directed
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed
M&L for chequered cement concrete tiles 20cm x 20cm x 25mm thick with grey pigment cement and pigments, set, jointed and pointed in neat cement slurry in floors over 20mm thick screed bed in CM 1:4 etc complete all as specified and directed.
Removing excavated soil exc. 250m but n exc 500m and depositing including spreading and levelling in layers n exc. 25cm thick etc complete all as specified and directed.
Material and labour for rendering 15 mm thick on fair faces of bhrick work in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including medium grade PVC conduit (suitable size) concealed in wall with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following:-
One light point/fan point/ex fan point controlled by one 5 Amps switch one way
One 3 pin 5 Amp switch socket outlet on independent board with accessories
All as per item No 1 here in before but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor.
S&F Modular switch 1 way 6 Amp, 1 module, 240 volts, complete all as specified and as directed.
S&F Modular socket out let 3 Pin 6 Amp, 2 module, 240 volts, complete all as specified and as directed.
S&F Modular socket combination 2 in 1 , 3 pin 6 & 16 Amp, 3 module, controlled by one switch, 240 volt, complete all as specified and as directed.
S & F Modular white cover plate with frame 3 module
S & F Modular white cover plate with frame 8 module
S & F modular metal flush box 3 module
S & F modular metal flush box 8 module
Supply and fix ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fix wall mounted fan 400 mm sweep,High speed, AC single Phase, 230V. Complete all as specified and as directed.
Supply and fixing SPN MCB DB 12 way double door type single phase with common earth and neutral 200 amps rated bus bars, 240 volts complete all as specified and as directed.
Supply and fixing SPN MCB 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single pole and current carrying capacity 6 to 32 amp in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
Supply and fixing concealed type GI sheet enclosure for Modular switches/sockets etc. complete with a 20 amps modular type motor starter (2 module) with one single pole modular type 'C' curve MCB of capacity 20 Amps (1 module) & a 20 Amps 3 pin Module socket (2 module) including 20 A plug top and electrical connections all as specified and directed. (For Air conditioners)
Pumping down the AC, taking carefully the indoor and outdoor units along with voltage stablizer of split type air conditioner of capacity upto 2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and reinstalling the same indoor and outdoor units alongwith stablizer at same location after completion of B/R work and connecting all the electrical, suction and discharge lines and testing on completion for proper function ing complete all as specified and directed.
m/s pal associates
M/S PRATAP ENTERPRISES
NAVSURAJ CONSTRUCTION AND INFRADEVELOPERS
M/s R D Enterprises
M/S SURYA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .