| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC R H NO 14 ADITYA PALACE PATOLE MALE B H SUMAN HOSPITAL JAI BHAWANI ROAD NASIK ROAD 422102 | NASIK | NASHIK | MAHARASHTRA | 422102 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹21.8 L+₹2.0 L (10.3%)Rejected-Finance | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹22.4 L+₹2.6 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹22.4 L+₹2.6 L (13.3%)Rejected-Finance | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹22.6 L+₹2.8 L (14.4%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹27.2 L
EMD Value
₹55,000
Closing Date
18 Mar 2022, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per tender documents
2022_MES_509063_1
GE/NRC/8879/E8
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Nasik Road
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer Nasik Road
₹55,000
30 Mar 2022
18 Feb 2022
21 Mar 2022
18 Feb 2022
18 Mar 2022
4 Mar 2022
Amount
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed
S & F pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated of approved profile steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws with washer complete all as specified and directed
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed
S&F rolled mild steel Joist, channel, angle, flat sections, fixed independently, without connecting plates, or M S tubular sections etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) grade Fe 290( E-165) all as directed by Engr-in-charge
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over one coat of red oxide primer on new steel surfaces, girth or width exc 10cm complete all as specified and directed
Dismantling of wall and ceiling boards (fibre, pulp, insulation,etc) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed
S&F interlocking aluminium powder coated snap grid consists of main Tee runners of size 38mm x 25mm x 1.00 mm spaced 1200mm centre to centre and cross Tee of size 25mm x 25mm x1.00mm, 1200 long spaced between the main Tee at 600mm centre to centre to form a grid of 1200mm x 600mm and provide a secondary cross Te 25mm x 25mm x 1.4mm (of length 600mm) to be interlocked of the centre of 1200mm x 600mm panel to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 1.5mm . Aluminium alloy extruded section shall be aluminium anodized ( minimum 15 micron) and shall conform to IS 733, IS 1285 and IS 737, and providing and fixing with Hangers of 4mm dia GI (upto 1200mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long size of grid 600 x 600mm with non asbestos cement pre-painted building board 4mm thick of make E board classic of M/s Everest industries Ltd or equivalent make as approved, “in ceiling fixed with screw as per manufacturer instruction” complete all as specified and directed
Complete removal of existing treatment and applying 3mm thick wall care putty incl primer coat as prepatory to distemper with two coats of oil bound distemper white or tinted on walls
Material & Labour for painting with one coat of synthetic enamel paint over a coat of pink primer on old wooden surfaces exc 10cm width or girth including preparation of old wooden surfaces all as specified and directed by Engr-in-Charge.
S&F Providing precast cement concrete type B1, 1:2:4 (20mm graded stone aggregate) in window or door cills, lintels, bressumers, steps,quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, Kerb stones etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match with CM 1:6 complete all as specified and directed.
E/M PORTION. Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down and hanging during point wiring of ceiling fan/exhaust fan of any size and sweep in proper manner and connecting up including provision of cable from ceiling rose or connector to fan all as per specified and directed by Engr-in-Charge
Dismantling unserviceable main switch/DBs with MCBs and wooden board including making good disturbed surface of wall.
Taking down sub main wiring of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sqmm stranded for earth continuity wire, to be drawn in and including, PVC medium grade surface casing capping not less then 20 mm width with MS sheet metal sunken switch/Terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified. Note : Cutting chases and making good to match with the adjoining surface shall be included in the unit rate.
All as per item No 15.00 but One light point controlled by one, one way switch
All as per item No 15.00 but One ceiling /exhaust fan point controlled by one switch and regulator
All as per item No 15.00 but One 3 pin 5 amp socket out point on the same board with other switches.
All as per item No 15.00 but One3 pin 5 amps socket out let point on independent board
All as per same in item No 15.00 above but for one socket outlet 15 amp on independent board with 2.5 Sq. mm cable and 2.5 Sq.mm. earth wire.
S &F Switch piano flush type single pole one way 5 amps.
S &F Socket outlet 2 in 1, 3 pin, 6A
S &F Switch socket combination 2 in 1, 6A flush type
S &F in repair Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal .
S &F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body
S &F Electronic regulator 100/120 Watt step type
Supply and fixing LED lights fitting 1x 20W, 220V, AC, decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver (Make : Havells/Crompton/Bajaj )
S & F 15 Watt LED streetlight fitting luminaire made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 , including coneecting up with 2/3 core flexible coppper conductor cable , compete all as specified and directed by Engr-in-Charge.
Fabrication,supply & fixing of GI pipe bracket up to 40 mm dia- 0.9m long & 2 set of clamps made out of 30x5mm ms flat & fixed with anchor bolt suitable for 15 w LED security light fitting
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4 Sqmm to be drawn through and including PVC casing capping not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit.
Material and labour for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm, earth continuity conductor of size 6 Sqmm to be drawn through and including PVC CASING CAPPING not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 6 sqmm and one run of PVC casing capping shall be measured as one unit.
S & F 4 way TP&N Vertical Loadline DBs in double door suitable for TP/FP MCCB with Range upto 160 A , breaking capacity : 10 kA / 16 kA / 25 kA , Bus Bars, Neutral Links, Blanking Plates without out MCCB, HSN Code - 8537, complete all as specified and directed by Engr-in-Charge,
S&F Sheet metal enclosure factory made for DBs Triple pole and neutral double door 415 volts 4 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 volts 4 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed.
Supply and fix for MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps
S&F MCB, single pole and neutral, 240 Volts , 40-63 Amps all as specified and as directed.
S&F MCB, single pole and neutral, 240 Volts , 6-40 Amps all as specified and as directed.
S&F MCB singal pole 240 Volts , 32 to 63 Amps all as specified and as directed.
S&F MCB singal pole 240 Volts , 6 to 32 Amps all as specified and as directed.
S & F in repair MCCB, 100 Amps , 415Volts, 16KA ,4 pole.
M&L Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers including earthing pit , charcoal, common salt ,earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long, PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work of any type of soil/strata all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 32358.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
M/S K. K. Construction
Vishal Constructions
UNITED ENTERPRISES
M/S R.K.S. CONSTRUCTION
Vinod Enterprises
Alpha Construction
Rehoboth Buildcon
M/S VISHAKHA CONSTRUCTION
Bidder Name
Vishal Constructions
SVT ENGINEERS AND CONTRACTOR.
M/S K. K. Construction
Alpha Construction
UNITED ENTERPRISES
Vinod Enterprises
M/S R.K.S. CONSTRUCTION
M/S VISHAKHA CONSTRUCTION
Rehoboth Buildcon
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .