Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | ₹37.3 L Quoted ₹39.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹42.2 L+₹3.1 L (7.93%)Rejected-Finance 110 245 NEHRU NAGAR KANPUR UTTAR PRADESH 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹42.2 L+₹3.1 L (7.93%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | L3₹42.3 L+₹3.2 L (8.29%)Rejected-Finance JAJJAR KOTLI JAMMU J K 151222 | JAMMU | JAMMU | J K | 151222 | ₹42.3 L+₹3.2 L (8.29%) | L3 | Rejected-Finance OTHER THAN L1 |
| 4 | L4₹44.6 L+₹5.5 L (14.2%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | ₹44.6 L+₹5.5 L (14.2%) | L4 | Rejected-Finance OTHER THAN L1 |
| Sl No | Description | Qty | Unit | DEV RAJ MAGOTRA L4 | M/S N.K. POWER SYSTEMS AND PROJECTS L1 | SHARMA SALES CORPORATION L2 | BARU ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 50 to 60 HP complete all as specified and directed by Engineer-in-charge.
Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates.
(ii) S&F of parts shall be measured and paid separately under respective item of sch A. | 5 | Each Job | 4,000 ₹20,000 | 2,900 ₹14,500 Lowest | 4,700 ₹23,500 | 4,000 ₹20,000 |
| 2.00 | Description all as per ser item No 1.00 here-in-before, but capacity 30 to 40 HP. | 3 | Each Job | 3,500 ₹10,500 | 2,900 ₹8,700 Lowest | 2,900 ₹8,700 Lowest | 3,500 ₹10,500 |
| 3.00 | Description all as per ser item No 1.00 here-in-before, but capacity 15 to 20 HP. | 5 | Each Job | 3,500 ₹17,500 | 2,900 ₹14,500 | 1,550 ₹7,750 Lowest | 3,500 ₹17,500 |
| 4.00 | Description all as per ser item No 1.00 here-in-before, but capacity 7.5 to 10 HP | 5 | Each Job | 3,000 ₹15,000 | 2,900 ₹14,500 | 1,233 ₹6,165 Lowest | 3,000 ₹15,000 |
| 5.00S&F New parts for single/multistage pumps of capacity 50 to 60 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engineer-in-charge. | |||||||
| 5.01 | Impeller, MOC: CI. | 5 | Each | 6,000 ₹30,000 | 6,900 ₹34,500 | 4,007 ₹20,035 Lowest | 6,000 ₹30,000 |
| 5.02 | Pump shaft stainless steel shaft complete with check nut and keys | 1 | Each | 3,900 ₹3,900 | 1,999 ₹1,999 | 1,550 ₹1,550 Lowest | 3,900 ₹3,900 |
| 5.03 | Tyre coupling/star coupling | 8 | Each | 1,300 ₹10,400 | 1,999 ₹15,992 | 1,190 ₹9,520 Lowest | 1,300 ₹10,400 |
| 5.04 | Star /Tyre coupler made of steel | 1 | Each | 300 ₹300 Lowest | 1,999 ₹1,999 | 1,550 ₹1,550 | 300 ₹300 Lowest |
| 5.05 | Gland cup | 5 | Each | 1,000 ₹5,000 | 1,999 ₹9,995 | 560 ₹2,800 Lowest | 1,000 ₹5,000 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
14 May 2026, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur PO-Garhi pin-182121
Repair/Replacement pipeline control valve pumping system and switchgear installed at Command HQ area, PB enclave, Alpha Mess, PH, MT PH and Sappers Enclave under GE Utilities Udhampur
2026_MES_761757_1
GE/U-25/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹96,000
27 Jun 2026
23 Apr 2026
16 May 2026
23 Apr 2026
14 May 2026
7 May 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE Utilities Udhampur
Name of Work: Repair /Replacement pipe line control valve pumping system and switchgear installed at Command HQ Area, PB Enclave Alpha Mess PH, MT PH and Sappers Enclave under AOR of GE (Utilities) Udhampur
Contract No: GE/U-25/2026-27
Ser. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity 50 to 60 HP complete all as specified and directed by Engineer-in-charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A. BI01010001010000000000000515BI0100001147 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 1.00 here-in-before, but capacity 30 to 40 HP. BI01010001010000000000000515BI0100001148 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 1.00 here-in-before, but capacity 15 to 20 HP. BI01010001010000000000000515BI0100001149 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 1.00 here-in-before, but capacity 7.5 to 10 HP BI01010001010000000000000515BI0100001150 Each Job 0.0000 Excess(+) Full Conversion INR
S&F New parts for single/multistage pumps of capacity 50 to 60 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engineer-in-charge. BI01010001010000000000000515BI0100001151
Impeller, MOC: CI. BI01010001010000000000000515BI0100001152 Each 0.0000 Excess(+) Full Conversion INR
Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001153 Each 0.0000 Excess(+) Full Conversion INR
Tyre coupling/star coupling BI01010001010000000000000515BI0100001154 Each 0.0000 Excess(+) Full Conversion INR
Star /Tyre coupler made of steel BI01010001010000000000000515BI0100001155 Each 0.0000 Excess(+) Full Conversion INR
Gland cup BI01010001010000000000000515BI0100001156 Each 0.0000 Excess(+) Full Conversion INR
Shaft sleeves BI01010001010000000000000515BI0100001157 Each 0.0000 Excess(+) Full Conversion INR
Bearing housing BI01010001010000000000000515BI0100001158 Each 0.0000 Excess(+) Full Conversion INR
Casing housing BI01010001010000000000000515BI0100001159 Each 0.0000 Excess(+) Full Conversion INR
S&F New parts for single/multistage pump of capacity 30 to 40 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engineer-in-charge. BI01010001010000000000000515BI0100001160
Impeller, MOC: CI. BI01010001010000000000000515BI0100001161 Each 0.0000 Excess(+) Full Conversion INR
Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001162 Each 0.0000 Excess(+) Full Conversion INR
Tyre coupling/star coupling BI01010001010000000000000515BI0100001163 Each 0.0000 Excess(+) Full Conversion INR
Star coupler made of steel BI01010001010000000000000515BI0100001164 Each 0.0000 Excess(+) Full Conversion INR
Gland cup BI01010001010000000000000515BI0100001165 Each 0.0000 Excess(+) Full Conversion INR
Shaft sleeves BI01010001010000000000000515BI0100001166 Each 0.0000 Excess(+) Full Conversion INR
Bearing housing BI01010001010000000000000515BI0100001167 Each 0.0000 Excess(+) Full Conversion INR
Casing housing BI01010001010000000000000515BI0100001168 Each 0.0000 Excess(+) Full Conversion INR
S&F New parts for single/multistage pump of capacity 15 to 20 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engineer-in-charge. BI01010001010000000000000515BI0100001169
Impeller, MOC: CI. BI01010001010000000000000515BI0100001170 Each 0.0000 Excess(+) Full Conversion INR
Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001171 Each 0.0000 Excess(+) Full Conversion INR
Tyre coupling/star coupling BI01010001010000000000000515BI0100001172 Each 0.0000 Excess(+) Full Conversion INR
Star /Tyre coupler made of steel BI01010001010000000000000515BI0100001173 Each 0.0000 Excess(+) Full Conversion INR
Gland cup BI01010001010000000000000515BI0100001174 Each 0.0000 Excess(+) Full Conversion INR
Shaft sleeves BI01010001010000000000000515BI0100001175 Each 0.0000 Excess(+) Full Conversion INR
Bearing housing BI01010001010000000000000515BI0100001176 Each 0.0000 Excess(+) Full Conversion INR
Casing housing BI01010001010000000000000515BI0100001177 Each 0.0000 Excess(+) Full Conversion INR
S&F New parts for single/multistage pump of capacity 7.5 to 10 HP as per manufacturer's composition of existing make of pump as below complete all as specified and directed by Engineer-in-charge. BI01010001010000000000000515BI0100001178
Impeller, MOC: CI. BI01010001010000000000000515BI0100001179 Each 0.0000 Excess(+) Full Conversion INR
Pump shaft stainless steel shaft complete with check nut and keys BI01010001010000000000000515BI0100001180 Each 0.0000 Excess(+) Full Conversion INR
Tyre coupling/star coupling BI01010001010000000000000515BI0100001181 Each 0.0000 Excess(+) Full Conversion INR
Star /Tyre coupler made of steel BI01010001010000000000000515BI0100001182 Each 0.0000 Excess(+) Full Conversion INR
Gland cup BI01010001010000000000000515BI0100001183 Each 0.0000 Excess(+) Full Conversion INR
Shaft sleeves BI01010001010000000000000515BI0100001184 Each 0.0000 Excess(+) Full Conversion INR
Bearing housing BI01010001010000000000000515BI0100001185 Each 0.0000 Excess(+) Full Conversion INR
Casing housing BI01010001010000000000000515BI0100001186 Each 0.0000 Excess(+) Full Conversion INR
Pump seal BI01010001010000000000000515BI0100001187 Each 0.0000 Excess(+) Full Conversion INR
Lathe/Machining works of any type at workshop required for balancing of impller/for fixing of new parts to existing shfts required for proper setting and smooth functioning to achieve desired discharge of the pump for 50 to 60 HP pump complete all as specified and directed by Engineer-in-charge. BI01010001010000000000000515BI0100001188 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 9.00 here-in-before, but capacity of 30 to 40 HP motor BI01010001010000000000000515BI0100001189 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 9.00 here-in-before, but capacity of 15 to 20 HP motor BI01010001010000000000000515BI0100001190 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 9.00 here-in-before, but capacity of 7.5 to 10 HP motor BI01010001010000000000000515BI0100001191 Each Job 0.0000 Excess(+) Full Conversion INR
Disconnecting electric connection of 50 to 60 HP motor, removing the UNSV motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same complete all as specified and directed by Engineer-in-Charge. Note: (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001192 Each job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No13.00 here-in-before, but capacity 30 to 40 HP motor BI01010001010000000000000515BI0100001193 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No13.00 here-in-before, but capacity of 15 to 20 HP motor BI01010001010000000000000515BI0100001194 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No13.00 here-in-before, but capacity of of 7.5 to 10 HP motor BI01010001010000000000000515BI0100001195 Each Job 0.0000 Excess(+) Full Conversion INR
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 60/50/40/30/20/15/12/10/7.5 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time, complete all as specified and directed by Engineer-in-Charge. Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent make. BI01010001010000000000000515BI0100001196 Kgs 0.0000 Excess(+) Full Conversion INR
Supply and fixing in repair/replacement of 2 to 3 HP pumpset (including motor) by taking out from foundation, dismounting from base channels, strip opening all parts, derusting, cleaning, overhualing, etc for complete repair/ replacement of spare parts such as impeller, shaft, winding, bearings, coupling, body, etc and after repair/ replacement, reassembling of pumpset mounting and fixing on base channel, recoupling of suction & discharge line, realignment, commissioning and testing complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001197 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and fixing in repair/replacement of 0.5 to 1 HP pumpset (including motor) by taking out from foundation, dismounting from base channels, strip opening all parts, derusting, cleaning, overhualing, etc for complete repair/ replacement of spare parts such as impeller, shaft, winding, bearings, coupling, body, etc and after repair/ replacement, reassembling of pumpset mounting and fixing on base channel, recoupling of suction & discharge line, realignment, commissioning and testing complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001198 Each Job 0.0000 Excess(+) Full Conversion INR
M&L for repair of booster pressure pumpset of cap 0.25 HP to 1 HP by taking out from foundation, dismounting from base channels, strip opening all parts, derusting, cleaning, overhualing, etc for complete repair, reassembling of pumpset mounting and fixing on base channel, recoupling of suction & discharge line, realignment, commissioning and testing complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001199 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and fixing of relay switch for booster pressure pump of capacity 0.25 HP to 1 HP pumpset complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001200 Each 0.0000 Excess(+) Full Conversion INR
M&L for dismantling following spare parts of submersible pump and motor of cap 1 to 5 HP and separating the unserviceable parts cleaning the serviceable parts, re-metalling machinery polishing and re-assembling including replacement of old parts and necessary painting complete all as specified and directed by Engineer-in-Charge. Note:- Old unserviceable parts replaced will be measured and paid separately. BI01010001010000000000000515BI0100001201 Each Job 0.0000 Excess(+) Full Conversion INR
M&L for Impeller for submersible pump set and motor, complete all as specified and directed by Engineer-In-Charge. BI01010001010000000000000515BI0100001202 Each 0.0000 Excess(+) Full Conversion INR
M&L for Bush for impeller for submersible pump set and motor, complete all as specified and directed by Engineer-In-Charge. BI01010001010000000000000515BI0100001203 Each 0.0000 Excess(+) Full Conversion INR
S&F of Pump bearing No. 6307 C3, complete all as specified and directed by Engineer-in-Charge. Make:-SKF/NBC/NRB or equivalent make BI01010001010000000000000515BI0100001204 Each 0.0000 Excess(+) Full Conversion INR
S&F of Pump bearing No. 6308 2RS1/C3, complete all as specified and directed by Engineer-in-Charge. Make:-SKF/NBC/NRB or equivalent make BI01010001010000000000000515BI0100001205 Each 0.0000 Excess(+) Full Conversion INR
S&F of Pump bearing No. 7308 2RS1/C3, complete all as specified and directed by Engineer-in-Charge. Make:-SKF/NBC/NRB or equivalent make BI01010001010000000000000515BI0100001206 Each 0.0000 Excess(+) Full Conversion INR
S&F of Motor bearing No. 6311, complete all as specified and directed by Engineer-in-Charge. Make:-SKF/NBC/NRB or equivalent make BI01010001010000000000000515BI0100001207 Each 0.0000 Excess(+) Full Conversion INR
S&F of Pump bearing No. 7311/ NU 411M, complete all as specified and directed by Engineer-in-Charge. Make:-SKF/NBC/NRB or equivalent make BI01010001010000000000000515BI0100001208 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of ON load change over switch 320 Amps, 415 volts 4 pole with stainless steel enclosure inculding taking down the old existing change over switch complete all as specified and directed by Engineer-in-Charge. Make : Havells/ L&T/ ABB BI01010001010000000000000515BI0100001209 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 28.00 here-in-before, but of size 200 Amps. BI01010001010000000000000515BI0100001210 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 28.00 here-in-before, but of size 100 Amps. BI01010001010000000000000515BI0100001211 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of OFF load change over switch 320 Amps, 415 volts 4 pole with stainless steel enclosure inculding taking down the old existing change over switch complete all as specified and directed by Engineer-in-Charge BI01010001010000000000000515BI0100001212 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 31.00 here-in-before, but of size 200 Amps. BI01010001010000000000000515BI0100001213 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 31.00 here-in-before, but of size 100 Amps. BI01010001010000000000000515BI0100001214 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 31.00 here-in-before, but of size 63 Amps. BI01010001010000000000000515BI0100001215 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of load line MCCB 320/350 Amps 4 pole 415 volts with adjustable thermal and fixed magnetic setting of breaking capacity 35/36 KA,Ics=100% Icu conforming to IEC - 60947-2 including taking down the old existing MCCB complete all as specified and directed by Engineer-in-Charge. Make : L&T/Legrand/ABB/Siemens BI01010001010000000000000515BI0100001216 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 35.00 here-in-before, but of size 200 Amps. BI01010001010000000000000515BI0100001217 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 35.00 here-in-before, but of size 160 Amps. BI01010001010000000000000515BI0100001218 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 35.00 here-in-before, but of size 125 Amps. BI01010001010000000000000515BI0100001219 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 35.00 here-in-before, but of size 100 Amps. BI01010001010000000000000515BI0100001220 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 35.00 here-in-before, but of size 63 Amps. BI01010001010000000000000515BI0100001221 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of power contactor 3 pole with AC coil AC-3 duty rating at 415 Volts 50 Hz, frame size1 suitable for 60 HP centrifugal pump set as per Havells cat part No. IHPHA100400* BI01010001010000000000000515BI0100001222 Each 0.0000 Excess(+) Full Conversion INR
M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 50 sqmm inculding taking down existing old unserviceable cable of complete all as specified and directed by Engineer -in-charge. BI01010001010000000000000515BI0100001223 RM 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 42.00 here-in-before, but of size 25 sqmm BI01010001010000000000000515BI0100001224 RM 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 42.00 here-in-before, but of size 16 sqmm BI01010001010000000000000515BI0100001225 RM 0.0000 Excess(+) Full Conversion INR
M&L for copper thimble suitable for 50 Sqmm single core copper cable including taking down the existing unserviceable one complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001226 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 45.00 here-in-before, but of size 25 sqmm BI01010001010000000000000515BI0100001227 Each 0.0000 Excess(+) Full Conversion INR
Description all as per ser item No 45.00 here-in-before, but of size 16 sqmm BI01010001010000000000000515BI0100001228 Each 0.0000 Excess(+) Full Conversion INR
M&L for aluminium thimble of 150 sqmm size for cables complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001229 Each 0.0000 Excess(+) Full Conversion INR
M&L for aluminium thimble of 95 sqmm size for cables complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001230 Each 0.0000 Excess(+) Full Conversion INR
S&F capacitor upto 40 mfd for motor complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001231 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of booster pressure pump of capacity 1 HP pumpset complete all as specified and deposited Old booster pressure pump to MES store yard, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001232 Each 0.0000 Excess(+) Full Conversion INR
M&L for replacement of monoblock pumpset, 1.5 HP, Single phase, 220 volts, Size 50 mm x 40 mm, Material: Cast iron, Head range: 12.8-17.6 mtr, Discharge: 4.15 lps, Class A, 2 Pole, S1 Duty Type, Speed 2900 RPM, Suface finish paint coated and deposited Old Monoblock pump to MES store yard, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001233 Each Job 0.0000 Excess(+) Full Conversion INR
Supply and laying DWC (Double wall corruguated) pipe 40/32 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001234 RM 0.0000 Excess(+) Full Conversion INR
Supply and laying DWC (Double wall corruguated) pipe 50/41 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001235 RM 0.0000 Excess(+) Full Conversion INR
Supply and laying DWC (Double wall corruguated) pipe 75/63 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001236 RM 0.0000 Excess(+) Full Conversion INR
Supply and fixing in replacement of terminal boxes suitable for 60/50 HP motor as per existing specification including taking down the old existing terminal box, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001237 Each 0.0000 Excess(+) Full Conversion INR
Supply and fixing in replacement of terminal boxes suitable for 40/30/20 HP motor as per existing specification including taking down the old existing terminal box, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001238 Each 0.0000 Excess(+) Full Conversion INR
M & L for painting of Header/ pump and motor, frame, pipe line including surface preparation by scrapping with emery paper and painting two coats of synthetic enamel paint over one coat of red oxide primer of existing colour of approved make to the satisfaction of Engineer in Charge BI01010001010000000000000515BI0100001239 Sqm 0.0000 Excess(+) Full Conversion INR
M&L for writing with brush about the machinery installed in different instalations such as Cap, discharge,MES No,Year of installation and head of the machinery on the wall in front of the pump motor with black paint including removing the existing paint with help of grinde, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001240 Each Job 0.0000 Excess(+) Full Conversion INR
S&F in replacement of gland packing type 3 of size 8 mm made of asbestos grip with silicon complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001241 Kgs 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 60.00 here-in- before, but of size 10 mm BI01010001010000000000000515BI0100001242 Kgs 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 60.00 here-in- before, but of size 12 mm BI01010001010000000000000515BI0100001243 Kgs 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 60.00 here-in- before, but of size 14 mm BI01010001010000000000000515BI0100001244 Kgs 0.0000 Excess(+) Full Conversion INR
Supply and laying in replacement of synthetic rubber insulated mats 10 mm thick for insulation purpose suitable for electrical shock safety of sizes 2 m x 1.2 m, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001245 Each 0.0000 Excess(+) Full Conversion INR
S&F in replacement of MS stud bolts of existing size suitable for pumps and motors of various capacity installed at installations, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001246 Kgs 0.0000 Excess(+) Full Conversion INR
S&F in replacement of grouting nuts and bolts of existing size suitable for pumps and motors foundation of various capacity installed at installations, complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001247 Kgs 0.0000 Excess(+) Full Conversion INR
M&L for cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in sub base filling and mass concrete complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001248 Cum 0.0000 Excess(+) Full Conversion INR
M&L for cement concrete in foundations, type E-2, 1:5:10 (40mm graded aggregate) as in filling and mass concrete complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001249 Cum 0.0000 Excess(+) Full Conversion INR
Supply and fixing in repacement of Cast iron Foot valve Flanged with strainer of 150 mm dia including all types of fittings conforming to IS specification ccomplete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001250 Each 0.0000 Excess(+) Full Conversion INR
Supply and fixing in repacement of Cast iron Foot valve Flanged with strainer of 100 mm dia including all types of fittings conforming to IS specification complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001251 Each 0.0000 Excess(+) Full Conversion INR
Supply and fixing in repacement of Cast iron Foot valve Flanged with strainer of 80 mm dia including all types of fittings conforming to IS specification complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001252 Each 0.0000 Excess(+) Full Conversion INR
Supply only lithium base grease AP3 in 20 Kg pack suitable for application to ball bearing with operating temperature 30 to 120 degree celsius drop point 174 degree celsius, colour light fawn complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001253 Each 0.0000 Excess(+) Full Conversion INR
Supply only cotton waste coloured Grade "A' for cleaning rags in 25 Kgs bag complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001254 Each 0.0000 Excess(+) Full Conversion INR
S&F 3D signage board made of high quality plastic material with raised 3D letters supported with iron frame of size 4 mtr x 0.5 mtrs in Acrylic sheet moulded letters ALPHA MESS PUMP HOUSE Garrison Engineer (Utility) & B-Reserviour PUMP HOUSE Garrison Engineer (Utility) including MES logo printed on both side of name on the blue background with white colour of size 1x1 feet white in colour with good quality LED Strip including constant current electronic driver and making connection with suitable size copper conductor multistranded FRLSH wire including fixing on wall with clamps, complete all as specified and directed by Engr-in-Charge. Note:- (a) Before for fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed by Engr-in-charge. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed by Engr-in-Charge. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete all as specified & directed by Engineer-in-Charge. Make of LED strip :-Philips,Wipro,Havells or equivalent BI01010001010000000000000515BI0100001255 Each Job 0.0000 Excess(+) Full Conversion INR
M&L for flex banner of size 1.5 mtr x 1 mtr supported with iron frame, about the Flow chart of distribution Network 1xALPHA MESS PH, 1xNCSR PH, 1xMT PH & 1xTHOMAS BRIDGE PH on the blue background with white colour including fixing on wall with clamps. Note:- (a) Before for fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed by Engr-in-charge. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed by Engr-in-Charge. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001256 Each 0.0000 Excess(+) Full Conversion INR
M&L for flex banner of size 1.0 mtr x 0.6 mtr supported with iron frame, about the machinery installed in different instalations such as Cap, discharge, MES No, Year of installation and head of the machinery on the blue background with white colour including fixing on wall with clamps. Note:- (a) Before for fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed by Engineer-in-charge. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed by Engr-in-Charge. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001257 Each 0.0000 Excess(+) Full Conversion INR
M&L for flex banner supported with iron frame of size 1.5 mtr x 0.3 mtr, about the Name of Pump house ALPHA MESS PH,NCSR PH, MT PH, Thomas Bridge PH, Bikram Encalve PH & NSOI Swimming Pool PH including MES logo printed on both side of name, on the blue background with white colour including fixing on wall with clamps and fixing of 30w Flood Light over the banner. the quoted rate included all the items required the fixing banners on Each Installations. Note:- (a) Before for fabrication of the display board, the contractor has to produce a paper printout detailing all documents and matter to be displayed so as to get it inspected and passed by Engr-in-charge. (b) Matter to be displayed, colour of the ACP sheet and colour of Retro Reflective sheet will be as specified and directed by Engr-in-Charge. (c) The quoted rate is deemed to be inclusive of cost of labour and materials required for fixing of the display board at the location including providing electrical connections complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001258 Each 0.0000 Excess(+) Full Conversion INR
Supply only Electrical Insulation Tape roll Thickness: 0.18 mm, Width: 19 mm, Length: 20 mtr complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001259 Each 0.0000 Excess(+) Full Conversion INR
Supply only Nylon Trimmer Line Wire for Bruss Cutter Trimmer Thickness: 3 mm, Length: 200 mtr complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001260 Each 0.0000 Excess(+) Full Conversion INR
Supply and laying, jointing and testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 95 sqmm 3.5 core laid in trenches,ducts, pipes complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001261 RM 0.0000 Excess(+) Full Conversion INR
M&L for brick/ stone masonary valve pit chamber of size 1.0 mtr x 1.0 mtr x 0.6 mtr internal dimension) with 3.15 mm thick MS cover including 50 x 50 x 6 mm angle iron frame with 100mm hinges embedded in coping with locking arrangement and painting the MS surfaces with two coat of redoxide primer & syntheatic enamel paint. The chamber shall be of PCC 1:4:8 type D2 40mm graded aggregate for foundation, brick work in cement mortar, 75mm PCC coping with PCC 1:3:6 type C1, 15 mm thick plastering in cement mortar 1:4 including necessary excavation, earth work and colour washing internally and externally surfaces complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001262 Each Job 0.0000 Excess(+) Full Conversion INR
Earthing of machinery/equipment Installed at power house/substation with galvanised steel earth plate electrode 600 mm × 600 mm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 32× 6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion. BI01010001010000000000000515BI0100001263 Each 0.0000 Excess(+) Full Conversion INR
Opening, maintenance and general servicing of Servo voltage stablizers of 100 KVA including removal of sludge from disserstate coils, buck boost transformers, tightening of all nut bolts, cleaning of stablizers coils, checking and servicing of servo mechanism, gear synchronising system, automatic voltage regulator circuits and other allied electrical components complete all as specified & directed by Engineer-in-Charge. Note : Rate quoted by contractor is inclusive of following items:- (a) Servo motor with RC network having torque upto 3 kg/cm - 01 Nos (b) Servo motor with RC network having torque upto 10 kg/cm - 01 Nos (c) Electronic cntrol card for automatic voltage regulation - 01 Nos (d)Transformer oil -35 ltrs (e) Voltmeter 0-500 volt capacity - 01 Nos (f) Ammeter CT Operated - 01 Nos (g) Circuit plate 100 KVA - 01 Nos (h) Pulse transformer of cap 100 KVA - 01 Nos (i) Rewinding for copper coil -25 Kg (j) Shifting of stablizer from AOR of AGE Water supply to workshop (Tro/ Fro) (f) Items like carbon bush, push buttons auto/manual/micro press switch, indicator lamps, etc BI01010001010000000000000515BI0100001264 Each Job 0.0000 Excess(+) Full Conversion INR
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth,foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. and taking out/laying of pipe lines of soft/loose soil. complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001265 Cum 0.0000 Excess(+) Full Conversion INR
Returning, filling in, including spreading, leveling, watering and well ramming in layers, each layer not exceeding 25cm thick after pipes have been laid and tested complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001266 Cum 0.0000 Excess(+) Full Conversion INR
Removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete, all as specified and directed by Engineer-in-Charge BI01010001010000000000000515BI0100001267 Cum 0.0000 Excess(+) Full Conversion INR
Taking up or down old unseviceable GI pipe of size 150 mm dia including all fittings complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001268 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 100 mm dia BI01010001010000000000000515BI0100001269 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 80 mm dia BI01010001010000000000000515BI0100001270 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 50 mm dia BI01010001010000000000000515BI0100001271 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 40 mm dia BI01010001010000000000000515BI0100001272 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 25 mm dia BI01010001010000000000000515BI0100001273 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 20 mm dia BI01010001010000000000000515BI0100001274 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 87.00 here-in-before, but of size 15 mm dia BI01010001010000000000000515BI0100001275 Rm 0.0000 Excess(+) Full Conversion INR
Supply & fixing GI pipes of size 150 mm dia, medium grade, galvanized with all fitting such as bends, tees, nipples, union and sockets, clamps etc laid in trenches, under floor/walls etc complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001276 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 100 mm dia BI01010001010000000000000515BI0100001277 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 80 mm dia BI01010001010000000000000515BI0100001278 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 50 mm dia BI01010001010000000000000515BI0100001279 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 40 mm dia BI01010001010000000000000515BI0100001280 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 25 mm dia BI01010001010000000000000515BI0100001281 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 20 mm dia BI01010001010000000000000515BI0100001282 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 95.00 here-in-before, but of size 15 mm dia BI01010001010000000000000515BI0100001283 RM 0.0000 Excess(+) Full Conversion INR
Refixing GI/CI pipe obtained from Item No. 81 above and connections in new or old position (walls, trenches, ceiling and floors etc) of size 150 mm dia complete including main branch connections complete all as specified & directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001284 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before, but of size 100 mm dia. BI01010001010000000000000515BI0100001285 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 80 mm dia. BI01010001010000000000000515BI0100001286 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 50 mm dia. BI01010001010000000000000515BI0100001287 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 40 mm dia . BI01010001010000000000000515BI0100001288 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 25 mm dia. BI01010001010000000000000515BI0100001289 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 20 mm dia. BI01010001010000000000000515BI0100001290 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 103.00 here-in-before,but of size 15 mm dia. BI01010001010000000000000515BI0100001291 RM 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement cast iron sluice valve suitable of size 300 mm (PN 1.6) ISI Marked with iron wheel head both end flanged, non rising type and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing,complete all as specified and directed by Engineer-in-Charge. . BI01010001010000000000000515BI0100001292 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 111.00 here-in-before, but of size 200 mm dia BI01010001010000000000000515BI0100001293 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 111.00 here-in-before, but of size 150 mm dia BI01010001010000000000000515BI0100001294 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 111.00 here-in-before, but of size 100 mm dia BI01010001010000000000000515BI0100001295 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 111.00 here-in-before, but of size 80 mm dia BI01010001010000000000000515BI0100001296 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement of cast iron non return valve suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with the rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers including taking down the old existing, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001297 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 116.00 here-in-before, but of size 100 mm dia. BI01010001010000000000000515BI0100001298 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 116.00 here-in-before, but of size 80 mm dia. BI01010001010000000000000515BI0100001299 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix Foot Valve of size 80 mm dia, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001300 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix Foot Valve of size 50 mm dia, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001301 Each 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement of cast iron air release valve with two air outlets of size 100 mm dia as per IS 14845 including all jointing materials like high pressure rubber gasket nuts, bolts, washers with arrangement for fixing, including taking down complete, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001302 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 121.00 here-in-before, but of size 80 mm dia. BI01010001010000000000000515BI0100001303 Each 0.0000 Excess(+) Full Conversion INR
Repair to old sluice valve of size 300 mm dia for check nut, spindle, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001304 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 123.00 here-in-before, but of size 200 mm dia BI01010001010000000000000515BI0100001305 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 123.00 here-in-before, but of size 150 mm dia BI01010001010000000000000515BI0100001306 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 123.00 here-in-before, but of size 100 mm dia BI01010001010000000000000515BI0100001307 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 123.00 here-in-before, but of size 80 mm dia BI01010001010000000000000515BI0100001308 Each 0.0000 Excess(+) Full Conversion INR
Supply and fixing MS ERW pipe of bore 250 mm having wall thickness 6 mm with permissible tolerance + 10% conforming to IS-3589, ISI marked, in 6 meter long with welded flanges, MS flanges not less than 24 mm thick on both ends closed with end plates including provision of 03 nos inlets (3x 150 mm ) from pump side and 05 outlets from distribution side ( 02 x 150mm,03 x100 mm, dia MS pipe , 6 mm wall thickness with not less than 22 mm thick MS welded flanged ends including paint with two coat of synthetic enamelled paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001309 Each Job 0.0000 Excess(+) Full Conversion INR
Mounting of header at a height of 1.2 metre above the ground level on PCC pillar of dimension 0.5x0.5x1.8 meter (0.6 meter depth & 1.2 meter height above ground) are as under the followings. BI01010001010000000000000515BI0100001310
Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of GI/CI pipes and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001311 Cum 0.0000 Excess(+) Full Conversion INR
Returning filling in and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm. complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001312 Cum 0.0000 Excess(+) Full Conversion INR
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting piont complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001313 Cum 0.0000 Excess(+) Full Conversion INR
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pillar complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001314 Cum 0.0000 Excess(+) Full Conversion INR
M&L for RCC foundation, M-25 type (using 20 mm graded aggregates) including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001315 Cum 0.0000 Excess(+) Full Conversion INR
M&L for RCC Column, M-25 type (using 20 mm graded aggregates) complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001316 Cum 0.0000 Excess(+) Full Conversion INR
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001317 Kg 0.0000 Excess(+) Full Conversion INR
Grouting of nut bolts in the PCC pillar to support the header on both side with clamps complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001318 Kg 0.0000 Excess(+) Full Conversion INR
M&L for repair to leaking GI pipe line of size 50 mm to 80 mm bore by providing necessary fitting such as socket, Tee, Elbow,etc including necessary excavation, returning filling in trenches in any type of soil,bailing out water, and any depth complete all as specified and directed by Engineer-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra pipe will be measured and paid separately. BI01010001010000000000000515BI0100001319 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 130.00 here-in-before, but of size 20 mm to 40 mm bore pipe. BI01010001010000000000000515BI0100001320 Each Job 0.0000 Excess(+) Full Conversion INR
Material and labour for repair to leaking flanged/circular welding joints of 100 to 200 mm bore MS/GI pipe line by providing rubber or fiber board gasket, new flanges if required at site, nut bolts, washers and welding works where required etc, including necessary excavation, returning filling in trenches in any type of soil, bailing out water, and any depth complete all as specified and directed by Engineer-in-Charge. Note:- (i) Contractor fully responsible for necessory excavation for jointing work required T&P equipment, mechanical excavation work and man power at site requirement with making good disturbed surfaces of road/wall/floor etc and matching with existing surface included quoted rate. (ii) Required extra pipe will be measured and paid separately.. BI01010001010000000000000515BI0100001321 Each Job 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 132.00 here-in-before, but of dia 250 to 300 mm bore pipe BI01010001010000000000000515BI0100001322 Each Job 0.0000 Excess(+) Full Conversion INR
M&L for cutting of existing road for crossing of MS/DI/CI/GI pipes for laying of any size pipes including necessary exacavation and earth work including repairing the same as per existing complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001323 Cum 0.0000 Excess(+) Full Conversion INR
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) cement concrete in as in foundation filling of pole & stay complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001324 Cum 0.0000 Excess(+) Full Conversion INR
M&L for Premix ready mix road repair patching compound for instant road repair manufactured with a blend of bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg, complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001325 Each 0.0000 Excess(+) Full Conversion INR
Supply and laying or fixing or passing through pipe, PVC insulated heavy duty industrial cables 2 core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 2.5 sqmm (in replacement) & taking out old cable complete all as specified and directed by Engineer-in-Charge. Note :Excavation, earthwork, Pipe for cable protection, etc to be measured and paid for separately. BI01010001010000000000000515BI0100001326 RM 0.0000 Excess(+) Full Conversion INR
Supply and fixing the nipple brass nozzle as per sample including removal of existing unsv one complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001327 Each 0.0000 Excess(+) Full Conversion INR
Supply & Laying multicore PVC insulated and FR-LHS PVC round sheatehed, copper conductor(flexible) industrial cable 1100 volt grade confirming to Is 694 , 1.5 sqmm 1 core including suitable size PVC conduit laid complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001328 RM 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 139.00 here-in-before, but of size 2.5 sqmm 1 core. BI01010001010000000000000515BI0100001329 RM 0.0000 Excess(+) Full Conversion INR
Supply & laying of flexible pipe of 15/20 mm dia used for wiring purpose complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001330 RM 0.0000 Excess(+) Full Conversion INR
Supply and fix in replacement of PVC Foot valve of of size 110 mm dia PN 16 complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001331 Each 0.0000 Excess(+) Full Conversion INR
Providing & fixing 100mm dia bourden type, stainless steel dial type pressure Gauge (0 - 14 Kg) range, 4" BSP bottom entry on pump delivery line complete with ball valve (Glycerin based) complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001332 Each 0.0000 Excess(+) Full Conversion INR
S&F cast iron fittings for spigot and socket ends for pressure pipe for water mains such as bends, tapers, tee pieces single branch, cross collar, caps and plugs suitable for upto 150 mm bore, all specifications as per IS-1538 (Pt-1 to 23)-1976 and complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001333 Kgs 0.0000 Excess(+) Full Conversion INR
Supply fabrication and fixing MS joints like Flanged, bends, Tee, Tapers, collars, elbow, tail piece (any type) caps, plugs for 80 mm to 300 mm bore pipe complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001334 Kgs 0.0000 Excess(+) Full Conversion INR
S&F of Gun metal, globe or gate valves, 80mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001335 Each 0.0000 Excess(+) Full Conversion INR
S&F of Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001336 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 147.00 here-in-before, but size upto 40 mm bore. BI01010001010000000000000515BI0100001337 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 147.00 here-in-before, but size upto 25 mm bore. BI01010001010000000000000515BI0100001338 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 147.00 here-in-before, but size upto 20 mm bore. BI01010001010000000000000515BI0100001339 Each 0.0000 Excess(+) Full Conversion INR
Description all as per Ser item No 147.00 here-in-before, but size upto 15 mm bore. BI01010001010000000000000515BI0100001340 Each 0.0000 Excess(+) Full Conversion INR
Supply and fixing GI fittings medium grade ISI marked including complete all as required at site complete all as specified and directed by Engineer-in-Charge. BI01010001010000000000000515BI0100001341
Elbow 15mm BI01010001010000000000000515BI0100001342 Each 0.0000 Excess(+) Full Conversion INR
Elbow 20mm BI01010001010000000000000515BI0100001343 Each 0.0000 Excess(+) Full Conversion INR
Elbow 25mm BI01010001010000000000000515BI0100001344 Each 0.0000 Excess(+) Full Conversion INR
Elbow 40mm BI01010001010000000000000515BI0100001345 Each 0.0000 Excess(+) Full Conversion INR
Elbow 50mm BI01010001010000000000000515BI0100001346 Each 0.0000 Excess(+) Full Conversion INR
Elbow 80mm BI01010001010000000000000515BI0100001347 Each 0.0000 Excess(+) Full Conversion INR
Socket 15mm BI01010001010000000000000515BI0100001348 Each 0.0000 Excess(+) Full Conversion INR
Socket 20mm BI01010001010000000000000515BI0100001349 Each 0.0000 Excess(+) Full Conversion INR
Socket 25mm BI01010001010000000000000515BI0100001350 Each 0.0000 Excess(+) Full Conversion INR
Socket 40mm BI01010001010000000000000515BI0100001351 Each 0.0000 Excess(+) Full Conversion INR
Socket 50mm BI01010001010000000000000515BI0100001352 Each 0.0000 Excess(+) Full Conversion INR
Socket 80mm BI01010001010000000000000515BI0100001353 Each 0.0000 Excess(+) Full Conversion INR
Union 15mm BI01010001010000000000000515BI0100001354 Each 0.0000 Excess(+) Full Conversion INR
Union 20mm BI01010001010000000000000515BI0100001355 Each 0.0000 Excess(+) Full Conversion INR
Union 25mm BI01010001010000000000000515BI0100001356 Each 0.0000 Excess(+) Full Conversion INR
Union 40mm BI01010001010000000000000515BI0100001357 Each 0.0000 Excess(+) Full Conversion INR
Union 50mm BI01010001010000000000000515BI0100001358 Each 0.0000 Excess(+) Full Conversion INR
Union 80mm BI01010001010000000000000515BI0100001359 Each 0.0000 Excess(+) Full Conversion INR
Elbow reducer 20 x 15mm BI01010001010000000000000515BI0100001360 Each 0.0000 Excess(+) Full Conversion INR
Elbow reducer 25 x 20mm BI01010001010000000000000515BI0100001361 Each 0.0000 Excess(+) Full Conversion INR
Elbow reducer 40 x 25mm BI01010001010000000000000515BI0100001362 Each 0.0000 Excess(+) Full Conversion INR
Socket reducer 25x20mm BI01010001010000000000000515BI0100001363 Each 0.0000 Excess(+) Full Conversion INR
Socket reducer 40x25mm BI01010001010000000000000515BI0100001364 Each 0.0000 Excess(+) Full Conversion INR
Socket reducer 40x20mm BI01010001010000000000000515BI0100001365 Each 0.0000 Excess(+) Full Conversion INR
Socket reducer 50x25mm BI01010001010000000000000515BI0100001366 Each 0.0000 Excess(+) Full Conversion INR
Nipple 15 x50mm BI01010001010000000000000515BI0100001367 Each 0.0000 Excess(+) Full Conversion INR
Nipple 15 x100mm BI01010001010000000000000515BI0100001368 Each 0.0000 Excess(+) Full Conversion INR
Nipple 20 x50mm BI01010001010000000000000515BI0100001369 Each 0.0000 Excess(+) Full Conversion INR
Nipple 20 x100mm BI01010001010000000000000515BI0100001370 Each 0.0000 Excess(+) Full Conversion INR
Nipple 25 x 50mm BI01010001010000000000000515BI0100001371 Each 0.0000 Excess(+) Full Conversion INR
Nipple 25 x 100mm BI01010001010000000000000515BI0100001372 Each 0.0000 Excess(+) Full Conversion INR
Nipple 40 x 50mm BI01010001010000000000000515BI0100001373 Each 0.0000 Excess(+) Full Conversion INR
Nipple 40 x 100mm BI01010001010000000000000515BI0100001374 Each 0.0000 Excess(+) Full Conversion INR
Nipple 50 x 50mm BI01010001010000000000000515BI0100001375 Each 0.0000 Excess(+) Full Conversion INR
Nipple 50 x 100mm BI01010001010000000000000515BI0100001376 Each 0.0000 Excess(+) Full Conversion INR
Tee 15mm BI01010001010000000000000515BI0100001377 Each 0.0000 Excess(+) Full Conversion INR
Tee 20mm BI01010001010000000000000515BI0100001378 Each 0.0000 Excess(+) Full Conversion INR
Tee 25mm BI01010001010000000000000515BI0100001379 Each 0.0000 Excess(+) Full Conversion INR
Tee 20x15mm BI01010001010000000000000515BI0100001380 Each 0.0000 Excess(+) Full Conversion INR
Tee 25x20mm BI01010001010000000000000515BI0100001381 Each 0.0000 Excess(+) Full Conversion INR
Tee 40x15mm BI01010001010000000000000515BI0100001382 Each 0.0000 Excess(+) Full Conversion INR
Tee 40x20mm BI01010001010000000000000515BI0100001383 Each 0.0000 Excess(+) Full Conversion INR
Tee 40x25mm BI01010001010000000000000515BI0100001384 Each 0.0000 Excess(+) Full Conversion INR
Tee 50x25mm BI01010001010000000000000515BI0100001385 Each 0.0000 Excess(+) Full Conversion INR
Dead plug 15mm BI01010001010000000000000515BI0100001386 Each 0.0000 Excess(+) Full Conversion INR
Dead plug 20mm BI01010001010000000000000515BI0100001387 Each 0.0000 Excess(+) Full Conversion INR
Dead plug 25mm BI01010001010000000000000515BI0100001388 Each 0.0000 Excess(+) Full Conversion INR
Dead plug 40mm BI01010001010000000000000515BI0100001389 Each 0.0000 Excess(+) Full Conversion INR
Dead plug 50mm BI01010001010000000000000515BI0100001390 Each 0.0000 Excess(+) Full Conversion INR
lead BI01010001010000000000000515BI0100001391 Kgs 0.0000 Excess(+) Full Conversion INR
lead wool BI01010001010000000000000515BI0100001392 kgs 0.0000 Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_853280.xls
BOQ • 6.43 MB
TENDER25.pdf
Tender Documents • 1.30 MB
Amendmenttodate.pdf
PDF • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .