Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 LAccepted-AOC | L1 | Accepted-AOC Being first lowest | |
| 2 | L2₹13.8 L+₹2.5 L (21.6%)Rejected-Finance C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Other than first lowest | |
| 3 | L3₹14.7 L+₹3.4 L (29.6%)Rejected-Finance | L3 | Rejected-Finance Other than first lowest |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
28 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Lalagarh Jattan
GE Lalagarh Jattan
PROVN OF CERTAIN RW WORKS AT LGJ MIL STN
2024_MES_644624_1
8934-69/GE/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Lalagarh Jattan
As per tender document
8 documents required · 8 mandatory
₹500
GE Lalagarh Jattan
₹35,000
Yes
16 May 2024
29 Feb 2024
30 Mar 2024
29 Feb 2024
28 Mar 2024
14 Mar 2024
Amount
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Material and labour for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation filling & mass concrete complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work or stone /boulders masonry built in cement morter including all quoins, pillars,arches etc but excluding ashlar facing,dressed stone work and precast concrete article including cleaning and stacking servicable brick for re-use and blance removing rubbish from the site complete all as specified & directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6 metre mean radius built in cement mortar (1:6) all as specified & directed.
Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated material (surplus soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed by Engineer-in-charge.
M&L for broken stone hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick,watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M&L for 75 mm thick PCC type C-1,1:3:6 using 20 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:4) on any face of walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge. Note: WPC where ever added shall be measured and paid seperately.
Material and labour for rendering/plastering 15mm thick in cement mortar (1:6) on any face of walls or concrete surfaces, finished even and smooth without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
Material and labour for Non Skid ceramic coloured tiles (jointless) 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, laid in floor. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 15mm thick rendering in cement mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Material and labour for Non Skid ceramic coloured tiles (jointless) 7 to 8 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, on vertical surfaces such as in skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over and including 10mm thick rendering in cement mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
M&L for in repair 4.5mm thick Linoleum, plain coloured, laid in floors including stretching, cutting and fitting sealed down with an approved adhesive including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75mm thick PCC (1:4:8), type D-2 using 40 mm graded stone aggregate as in sub base and incl necessary formwork complete all as specified and as directed by Engineer-in-charge.
M&L for two coats of acrylic distemper on newly plastered surfaces of walls paint over 3mm thick wall care putty including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of new plastered or pointed surface of walls/pillars /cornices by sand papering or by any other mean and after preparing the surfaces applying two coats of cement base paint as approved tint/colour over a one coat of priming paint complete all as specified and as directed by Engineer-in-Charge.
Material and labour for preparation of old plastered or pointed surface of walls/pillars /cornices by sand papering or by any other mean and after preparing the surfaces applying one coats of cement base paint as approved tint/colour etc complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment and applying two coats of oil bound distemper over and including 3mm thick wall care putty after preparation of plastered or pointed surface of walls/pillars/cornices by sand papering or by any other means as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
Material and labour for complete removal of existing treatment and applying two coats of cement base paint over and including 3mm thick wall care putty after preparation of plastered surface of walls/pillars/cornices by sand papering or by any other means as approved tint/colour complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of new steel surface of any description over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
M&L precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate and set cement mortar 1:4 as in cover slabs (for manholes etc,) chajjas, shelves and similar articles with plain faces complete all as specified and directed by Engr-in-charge.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each and removing from site complete all as specified and as directed by Engineer-in- charge.
S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of poweder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge. Make of Al Section : Jindal / Hindalco / NALCO
S&F for powder coated anodised aluminium door shutters,, aluminium sections weighing exc 0.55 Kg/m including necessary necessary joining cleats, glazing clips, rubber neoprene packing, handles 1 Nos in each door, hinges (02 Nos), anodised aluminium snap beading, screws, complete all as specified Make of Al Section : Jindal / Hindalco / NALCO
S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick(iii) 'H' section 41 x 20 x 1.10 mm thick Make: Jindal or equivalent sections of Hindalco.
S&F for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes, framed guard bars; barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290-0 or grade E- 165 complete all as specified and as directed
M&L Machined pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with over sand cushion all as specified and directed. Note: sand filling shall be paid seperately.
M&L for sand filling under interlocking tiles or in foundation including watering and consolidation all specified and directed
M & L cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in benching /haunching manhole including forming channels Complete all as specified.
Supply only liquid water proofing compound complete all as directed by Engr-in-charge.
S&F in repairs drapery curtain rod 25mm dia fancy type, pretreated plastic coated natural colour ,fabricated out of mild steel sheet not less than 20 guage, with decorative end knobs complete with brackets and fixed on wall including taking down old existing curtain rods any description with accessories complete all as specified and directed by EIC.
M&L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m complete all as specified and as directed by Engineer-in-charge.
M&L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, with cement mortar 1 :4 complete
Supply and fixing for Mortice lock, vertical type, size 100 mm, 4 lever of brass body complete all as specified & directed by Engineer-in-charge.
M&L double action floor door spring hydraulically regulated,made up of minimum 1.25mm thick aluminium sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other patrs made of mild steel heavy duty complete all as specified.
Supply & fixing aluminium anodised barrel tower bolt of extruded section 200mm long complete all as specified & directed by Engineer-in-charge.
S&F 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls including taking down existing pipe complete all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete type B1 1:2:4 using 20mm graded stone aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, copings, bed plates,and the like including weathering, slightly rounded or chamfered angles and throating,incl formwork all as specified & directed.
Material and labour for providing precast cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in kerb stones size 300 mm x 300 mm x 100 mm with plain fair faces including chamfers, weathering, throating and form work etc. and setting in CM 1:4 complete all as specified and as directed by Engineer-in-Charge.
Material and labour for 450mm bore (internal dia) RCC pipe class NP2 laid on PCC bed to required slope, jointed and tested complete all as specified and directed by Engineer-in-Charge. (Note : Concrete bed shall be measured and paid for separately)
Material and labour for 350mm bore (internal dia) RCC pipe class NP2 laid on PCC bed to required slope, jointed and tested complete all as specified and directed by Engineer-in-Charge. (Note : Concrete bed shall be measured and paid for separately)
S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as per specification and directed
Dismantling asbestos cement ( corrugated, semi-corrugated, plain etc.) sheets in roof covering complete all as specified and directed by Engineer-in-Charge.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.(design as approved by Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-charge.
M&L for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates and conforming to Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed
Dismantling wall and Ceiling boards (Fibre, pulp,insulation etc) or insulation boards/slabs/ blankets of any thickness including cover fillets complete all as specified and directed.
Providing & fixing false ceiling at all heights with GRG (Glass Reinforced Gypsum) With Semi perforated 12mm thick micro tegular edged GRG false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% , humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and Lshape level adjuster of size 85x25x2mm.Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mmto be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawingand as per directions of the Engineer-in-Charge.
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sockets, regulator, rusted conduit etc and making good disturbed surfaces of walls and floors etc to match with the existing all as specified and directed by Engineer-in-Charge.
M&L for concealed Point wiring for One light/fan/Ext fan point controlled by one, one way switch controlled by one, oneway switch with single core PVC insulate, unsheathed multistranded copper conductor cable of size 1.5 sq.mm (FRLS) drawn in and including electrical grade PVC conduit 20 mm dia concealed on wall/ceiling/floor including PVC insulated unsheathed earth wire with multi stranded copper conductor of size 1.5 sq.mm(FRLS) including MS shunk sheet metal box with 3 mm thick bakelite plastic laminated sheet top cover with brass counter shunk screws with washer complete all as specified. Note - quoted rate shall include making good to the disturbed surfaces including plastering and painting to match with the existing colour.
All as per item No. 54 Above, but for 3 pin 5 Amp socket outlet on the same board with other switch, socket complete all as specified & directed by Engineer-in-Charge.
All as per item No. 54 Above, but for 3 pin 5 Amp socket outlet independent complete all as specified & directed by Engineer-in-Charge.
All as per item No. 54 Above, but point wiring with 4 sqmm multistranded conductor cable and 2.5 sqmm unsheathed copper conductor earth wire for two in one 6 pin 15 Amps socket outlet on independent board complete all as specified & directed by Engineer-in-Charge.
S & F swith piano type flush button single pole one way 5/6 Amps, 230 volts complete all as specified & directed by Engineer-in-Charge.
Supply and fix piano socket 2 in 1, 2/3 pin 5 amp flush type 240 volts AC complet all as specified and as directed
Supply and fix socket 2 in 1, 3 pin 5 amp and 15 amp flush type 240 volts AC complet all as specified and as directed
Supply and fix piano swith flush button single pole one way 15 Amps 240 volts AC complete all as specified and directed
Supply and fix 2 x 2 Ultra modern designed LED luminaire LED light fitting 1x 36 W, 230 V LED channel with white acrylic cover incl making connection complete all as directed.
Supply & fix batton integrated LED light fitting 1 x20 integral sleek polycarbonate LED channel with white acrylic cover to roof/ceiling/wall with necessary wooden/PVCblocks etc and connecting with 2 core flexible PVC insulated multistranded copper conductor from ceiling rose to fitting complete all as specified and directed including taking down old one. Note : (i) with lumen efficiency in excess of 100 Lumans per watt and driver effeciency >85% (withpf>0.95) (ii) CRI >80 (iii) The warranty of LED fittings is 02 years after completion of the liability period
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
PAREEK AND COMPANY
GOYAL ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .